Planning & Development Services; Building & Code Regulation Division
2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
Date: 04 `CQ Permit #• _ L7, 02 CD
Contractor: bL Q 1 d - es a-2 ,b
Job Address: 050d% CvDl�LQs i�JB D12 BMW r ,� CcE . -
Construction: ( New Construction —Complete ( ) Existing —After Addition
House Infiltra * Te3•t suits SLC Climate Zone 2
CFM (50) = I LZZ
Volume = O ag
ACH (50) = CFM (50) x 60 / Volume =
Passing results must be & ACH (50) or less
Test Date: a'f �� 4 / 20( X
M;eMech ical Ventilation required less than 3 ACH
( Pass ( )Fail
RECEIVED
APR .10 1018
Permitting Departmenr
St. Lucie County
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding Z air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(0, (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company ' �57�
Company Name: U�Address: � 1
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
require s m ccordance with Section R402.4.1.2 Climate Zone 2.
Printed Name:
License/Certification #: _P�t
File Copy
PARTIAL APPROVAL
t
RECEIVED
Planning & Development Services
Building & Code Regulation Division APR 10 2018
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982 Permitting Departmen,
S f T72462-2165 Fax.772.462-6443 St. Lucie County
_ " ` "�• FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method ` qg-c>
Date: 9� O c(• ($ Permit, 17 `y O 22C`� `( Lott o s .t
Contractor. Address: 9504 CroshL�n- r'E �t �cCC r�
Construction: ost Construction Test o Rough -in Test
Test Conditions: `$2g
Date: y (t Floor Area (ft2):
rime: 4 Cis •M Primary Location of Supply Ductwork
Indoor Temperature (F): Primary Location of Return Ductwork'LL
Outdoor Temperature (F): O�
Total Leakage Test f0utsidel
Duct Leakage: Dgfault e•Prop. Leak Free o Proposed On =
Test Pressure: L5 (Pa)
Baseline Duct Pressure (optional) (Pa)
Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Urfass o Fail
Install Pa 23.E
Total Leakage (cfm):
•
Total Leakage per 100 sgft
CFM25 x.100 divided by the CFA = Duct Leakage CFW100 sgfL
Testing Company Ot c c (� F—L
Company Name: � �T£G Address: `7� "�N J i �� I � IF #�
1 hereby certi t the above Duct mg Leakage results demonstrate compliance with 5h Edition FBC Energy Conservation requirements in accordance with
Section 03..2.
Signature:
Printed Name: QAXAAS3 4S6) &- `a License/Certificate # /v
ne COPY
w-riAL APPPO\JAV-