Loading...
HomeMy WebLinkAboutFBC Energy Conservation 4-16-18Planning & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE R402.4.1.2 House Infiltration Test (Blower Door) Certification Date: 04 "09. • ('Z Contractor.: Job Address: 6 0L_� RECEIVED APR .16 7nin Prescriptive and Performance Method Permitting DCou t, , l 17 06 — 6;22-0 1 �!7 St. Lucie ounr.� Permit #: � L ©G 02-zeo Construction: ( `) New Construction — Complete UQ ccp ( ) Existing —After Addition House Infiltrat'on T.es-t suits SLC Climate Zone 2 CFM (50) = ZO Test Date: Volume = (o rg ACH (50) =CFM (50) x 60 /Volume = Mech ical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less ( Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company C �G 6 ��A 1 Company Name: C�� i G Address: -\�7b � �«, aA4_J�Q I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirem s in ccordance with Section R402.4.1.2 Climate Zone 2. Signatu Printed.Name: License/Certification #:l_ (qoLt) #7 W) WAR APPROVFr, Planning & Development Services l Building & Code Regulation Division - RECEIVED 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 4 7,72462-2165 Fax 772462-6443 APR .1 101@ FBC ENERGY CONSERVATION CODE Permitting Department Duct Sealing Certification St. Lucle County Prescriptive and Performance Method l`f 0!o c3220 Date: �� ' �19 C K Permit #: r ` Co o 22 Lot #: 0 S Contractor: Address: 05b4 Cot`,r Ceg6p_ �f �'` Ir 6te7 Construction: ost Construction Test ❑ Rough -in Test Test Conditions: 1 ,D Date: y (� Floor Area (ft2): `03Z8 Time: 4M Primary Location of Supply Ductwork '1L. Indoor Temperature (F): Primary Location of Return Ductwork Outdoor Temperature (F): fl� Total Leakage Test (Outside) � � Duct Leakage: ❑ Default Prop. Leak Free ❑ Proposed On = Test Pressure: 2S (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: Vlfaiss ❑ Fail Install e Pa �7 O 3 t .2 Total Leakage (cfm): LS• Total Leakage per 100 sgft: CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sqft. Testing Company p� A Company Name: iGT�G Address: lX�C1-f �1� f� hereby certi t the above Duct ing Leakage results demonstrate compliance with 5t' Edition FBC Energy Conservation requirements in accordance with Section 03..2. Signature: Printed Name: License/Certificate APPROVED rJeTzaFk�1 - M