Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HUDSON 4 Builder Name: SYNERGY BUILDERS Street: 430 SE GASPARILLA AVENUE Permit Office: ST LUCIE COUNTY City,State,Zip: PORT ST LUCIE,FL,34983 Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL,MELBOURNE_REGIONAL_AP County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. W all Types(1728.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1496.00 ft2 b. Frame-Wood,Adjacent R=13.0 232.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (1922.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1833.00 ft2 6. Conditioned floor area above grade(ft2) 1833 b.Knee Wall(Vented) R=30.0 89.00 ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows(124.0 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl,U=0.30 124.00 ft2 a.Sup:Attic, Ret:Attic,AH:AHU CLST 6 140 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 34.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.105 ft.Area Weighted Average SHGC: 0.260 a.Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1833.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 1833.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits None Glass/Floor Area: 0.068 Total Proposed Modified Loads: 51.86 PASS Total Baseline Loads: 55.25 I hereby certify that the plans and specifications covered by Review of the plans and [FI l 37" �� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ` ,,. %' with the Florida Energy Code. ::.•,1� `"A��e PREPARED BY: Before construction is completed �* DATE: 1-6-202 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ;,.r � " with the Florida Energy Cod . OWNER/AGENT - BUILDING OFFICIAL: DATE: I -(A ®t-`'1- DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). - Proposed On of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HUDSON 4 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1833 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: SYNERGY BUILDERS Rotate Angle: 0 Street: 430 SE GASPARILLA A Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: PORT ST LUCIE, Family Type: Detached FL, 34983 New/Existing: New(From Plans) Comment: GARAGE LEFT CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MELBOURNE_REGIO FL_MELBOURNE_REGIO 45 90 70 75 369 69 Medium BLOCKS Number Name Area Volume 1 Entire House 1833 17168 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 84 672 No 0 1 Yes Yes Yes 2 M WIC 126 1008 No 0 1 Yes Yes Yes 3 MASTER BEDROO 210 1680 No 0 1 1 Yes Yes Yes 4 BEDROOM 3 149 1192 No 0 1 1 Yes Yes Yes 5 CLST 3 16 128 No 0 1 No Yes Yes 6 KITCHEN/DINING 376 4512 Yes 0 1 Yes Yes Yes 7 BATH 2 72 576 No 0 1 Yes Yes Yes 8 BEDROOM 2 144 1152 No 0 1 1 Yes Yes Yes 9 HALL 39 312 No 0 1 No Yes Yes 10 CLST 2 16 128 No 0 1 No Yes Yes 11 LAUNDRY 56 448 No 0 1 No Yes Yes 12 AHU CLST 9 72 No 0 1 No Yes Yes 13 GREAT ROOM 250 3000 No 0 1 Yes Yes Yes 14 FOYER 112 896 No 0 1 Yes Yes Yes 15 CLST 4 16 128 No 0 1 Yes Yes Yes 16 BEDROOM 4/DEN 158 1264 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation M BATH 20 ft 0 84 ft2 ---- 1 0 0 2 Slab-On-Grade Edge Insulation M W IC 9 ft 0 126 ft2 ---- 1 0 0 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulation MASTER BEDRO 29 ft 0 210 ft2 ---- 1 0 0 4 Slab-On-Grade Edge Insulation BEDROOM 3 11 ft 0 149 ft2 ---- 1 0 0 5 Slab-On-Grade Edge Insulation CLST 3 1 ft 0 16 ft2 ---- 1 0 0 6 Slab-On-Grade Edge Insulation KITCHEN/DININ 26 ft 0 376 ft2 ---- 1 0 0 7 Slab-On-Grade Edge Insulation BATH 2 6 ft 0 72 ft2 ---- 1 0 0 8 Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 144 ft2 ---- 1 0 0 9 Slab-On-Grade Edge Insulation HALL 1 ft 0 39 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 56 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 9 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation GREAT ROOM 14 ft 0 250 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation FOYER 7 ft 0 112 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation CLST 4 2 ft 0 16 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 4/DE 30.9 ft 0 158 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2049 ft2 0 ft2 Medium N 0.2 No 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1833 ft2 N N 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) M BATH 30 Blown 84 ft2 0.1 Wood 2 Under Attic(Vented) M W IC 30 Blown 126 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BEDRO 30 Blown 210 ft2 0.1 Wood 4 Under Attic(Vented) BEDROOM 3 30 Blown 149 ft2 0.1 Wood 5 Under Attic(Vented) CLST 3 30 Blown 16 ft2 0.1 Wood 6 Under Attic(Vented) KITCHEN/DININ 30 Blown 376 ft2 0.1 Wood 7 Under Attic(Vented) BATH 2 30 Blown 72 ft2 0.1 Wood 8 Under Attic(Vented) BEDROOM 2 30 Blown 144 ft2 0.1 Wood 9 Under Attic(Vented) HALL 30 Blown 39 ft2 0.1 Wood 10 Under Attic(Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 11 Under Attic(Vented) LAUNDRY 30 Blown 56 ft2 0.1 Wood 12 Under Attic(Vented) AHU CLST 30 Blown 9 ft2 0.1 Wood 13 Under Attic(Vented) GREAT ROOM 30 Blown 250 ft2 0.1 Wood 14 Under Attic(Vented) FOYER 30 Blown 112 ft2 0.1 Wood 15 Under Attic(Vented) CLST 4 30 Blown 16 ft2 0.1 Wood 16 Under Attic(Vented) BEDROOM 4/DE 30 Blown 158 ft2 0.1 Wood 17 Knee Wall(Vented) BEDROOM 2 30 Blown 18 ft2 0.1 Wood 18 Knee Wall(Vented) CLST 2 30 Blown 3 ft2 0.1 Wood 19 Knee Wall(Vented) LAUNDRY 30 Blown 10 ft2 0.1 Wood 20 Knee Wall(Vented) FOYER 30 Blown 22 ft2 0.1 Wood 21 Knee Wall(Vented) KITCHEN/DININ 30 Blown 15 ft2 0.1 Wood 22 Knee Wall(Vented) MASTER BEDRO 30 Blown 21 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo 1 SE Exterior Concrete Block-Int Insul M BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0 2 NE Exterior Concrete Block-Int Insul M BATH 4.1 14 0 8 0 112.0 ft2 0 0 0.2 0 3 SE Exterior Concrete Block-Int Insul M W IC 4.1 9 0 8 0 72.0 ft2 0 0 0.2 0 4 SE Exterior Concrete Block-Int InsuMASTER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.2 0 5 SW Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.2 0 6 NE Exterior Concrete Block-Int InsuBEDROOM 3 4.1 11 0 8 0 88.0 ft2 0 0 0.2 0 7 SE Exterior Concrete Block-Int InsuKITCHEN/DI 4.1 11 0 12 0 132.0 ft2 0 0 0.2 0 8 SW Exterior Concrete Block-Int InsuKITCHEN/DI 4.1 15 0 12 0 180.0 ft2 0 0 0.2 0 9 NE Exterior Concrete Block-Int Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0 10 NE Exterior Concrete Block-Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.2 0 11 NW Garage Frame-Wood BEDROOM 2 13 12 0 8 0 96.0 ft2 0 0.1 0.2 0 12 NW Garage Frame-Wood CLST 2 13 2 0 8 0 16.0 ft2 0 0.1 0.2 0 13 NW Garage Frame-Wood LAUNDRY 13 7 0 8 0 56.0 ft2 0 0.1 0.2 0 14 SW Exterior Concrete Block-Int InsuGREAT ROO 4.1 14 0 12 0 168.0 ft2 0 0 0.2 0 15 NW Exterior Concrete Block-Int Insul FOYER 4.1 7 0 8 0 56.0 ft2 0 0 0.2 0 16 NE Garage Frame-Wood FOYER 13 8 0 8 0 64.0 ft2 0 0.1 0.2 0 17 SW Exterior Concrete Block-Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.2 0 18 NE Exterior Concrete Block-Int InsLiBEDROOM 4/ 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 19 NW Exterior Concrete Block-Int InsuiBEDROOM 4/ 4.1 13 0 8 0 104.0 ft2 0 0 0.2 0 20 SW Exterior Concrete Block-Int InsLIBEDROOM 4/ 4.1 12 0 8 0 96.0 ft2 0 0 0.2 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 4 Metal Low-E Single Yes 0.3 0.26 N 9.0 ft2 1 ft 0 in 1 ft 4 in None None 2 SW 5 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 8 ft 0 in 1 ft 4 in None None 3 NE 6 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 4 SE 7 Metal Low-E Single Yes 0.3 0.26 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None 5 SW 8 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 NE 10 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 7 NW 19 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 21 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000297 1430.7 78.49 147.36 .1044 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 14 34 kBtu/hr 1020 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 60.9 gal 120 deg None 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 140 ftz Attic 14 ftz Proposed Qn AHU CLST ---cfm 146.6 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb ]Mar Apr May rl Jun Jul X Aug Se Oct Nov Dec Heatin �Xj Jan �Xj Feb lX]Mar f Apr f May Jun �xl Jul f Aug 4 Sep Oct Nov X Dec Venting [[ ]]Jan [[ ]]Feb [X]Mar [X]Apr [ May Jun Jul [ Aug [ Sep [ Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ftz ft 0.3 DINING Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz ft 0.3 UTILITY RM Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER/GREAT RM Default(8 Ibs/s .ft. ftz ft 0.3 BEDROOM 1 1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HUDSON 4 Builder Name: SYNERGY BUILDERS Street: 430 SE GASPARILLA AVENUE Permit Office: ST LUCIE COUNTY City,State,Zip: PORT ST LUCIE,FL,34983 Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL,MELBOURNE_REGIONAL_AP U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilincis. a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/5/2022 5:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 430 SE GASPARILLA AVENUE, PORT ST LUCIE, FL, 34983 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1496.00 ft2 b.Frame-Wood,Adjacent R=13.0 232.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1833.00 ft2 6. Conditioned floor area(W) 1833 b.Knee Wall(Vented) R=30.0 89.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Sgl,U=0.30 124.00 ft2 12.Ducts,location&insulation level R ft2 SHGC: SHGC=0.26 a.Sup:Attic, Ret:Attic,AH:AHU CLST 6 140 b. U-Factor: N/A ft2 SHGC: 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.105 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap:40 gallons EF:0.92 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1833.00 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Buildingrt srfi Construction through the above energy saving features which will be installed (or exceeded) � _ 0 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ' Date: I -C-0 2 7 0 � Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/5/2022 5:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1