HomeMy WebLinkAboutENERGY EFFICIENCY CODE FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HUDSON 4 Builder Name: SYNERGY BUILDERS
Street: 430 SE GASPARILLA AVENUE Permit Office: ST LUCIE COUNTY
City,State,Zip: PORT ST LUCIE,FL,34983 Permit Number:
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL,MELBOURNE_REGIONAL_AP County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. W all Types(1728.0 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1496.00 ft2
b. Frame-Wood,Adjacent R=13.0 232.00 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Types (1922.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1833.00 ft2
6. Conditioned floor area above grade(ft2) 1833 b.Knee Wall(Vented) R=30.0 89.00 ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
7. Windows(124.0 sqft.) Description Area 12. Ducts R ft2
a. U-Factor: Sgl,U=0.30 124.00 ft2 a.Sup:Attic, Ret:Attic,AH:AHU CLST 6 140
SHGC: SHGC=0.26
b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 34.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 4.105 ft.Area Weighted Average SHGC: 0.260 a.Electric Strip Heat 27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15. Hot water systems
SHGC(AVG): N/A a. Electric Cap:40 gallons
9. Floor Types (1833.0 sqft.) Insulation Area EF:0.920
a.Slab-On-Grade Edge Insulation R=0.0 1833.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 16.Credits None
Glass/Floor Area: 0.068
Total Proposed Modified Loads: 51.86 PASS
Total Baseline Loads: 55.25
I hereby certify that the plans and specifications covered by Review of the plans and [FI l 37" ��
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance ` ,,. %'
with the Florida Energy Code. ::.•,1� `"A��e
PREPARED BY: Before construction is completed �*
DATE: 1-6-202 this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes. ;,.r � "
with the Florida Energy Cod .
OWNER/AGENT - BUILDING OFFICIAL:
DATE: I -(A ®t-`'1- DATE: -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
- Proposed On of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405
.2.3
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: HUDSON 4 Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1833 Lot#
Owner Name: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: SYNERGY BUILDERS Rotate Angle: 0 Street: 430 SE GASPARILLA A
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City,State,Zip: PORT ST LUCIE,
Family Type: Detached FL, 34983
New/Existing: New(From Plans)
Comment: GARAGE LEFT
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,MELBOURNE_REGIO FL_MELBOURNE_REGIO 45 90 70 75 369 69 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1833 17168
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 M BATH 84 672 No 0 1 Yes Yes Yes
2 M WIC 126 1008 No 0 1 Yes Yes Yes
3 MASTER BEDROO 210 1680 No 0 1 1 Yes Yes Yes
4 BEDROOM 3 149 1192 No 0 1 1 Yes Yes Yes
5 CLST 3 16 128 No 0 1 No Yes Yes
6 KITCHEN/DINING 376 4512 Yes 0 1 Yes Yes Yes
7 BATH 2 72 576 No 0 1 Yes Yes Yes
8 BEDROOM 2 144 1152 No 0 1 1 Yes Yes Yes
9 HALL 39 312 No 0 1 No Yes Yes
10 CLST 2 16 128 No 0 1 No Yes Yes
11 LAUNDRY 56 448 No 0 1 No Yes Yes
12 AHU CLST 9 72 No 0 1 No Yes Yes
13 GREAT ROOM 250 3000 No 0 1 Yes Yes Yes
14 FOYER 112 896 No 0 1 Yes Yes Yes
15 CLST 4 16 128 No 0 1 Yes Yes Yes
16 BEDROOM 4/DEN 158 1264 No 0 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation M BATH 20 ft 0 84 ft2 ---- 1 0 0
2 Slab-On-Grade Edge Insulation M W IC 9 ft 0 126 ft2 ---- 1 0 0
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
3 Slab-On-Grade Edge Insulation MASTER BEDRO 29 ft 0 210 ft2 ---- 1 0 0
4 Slab-On-Grade Edge Insulation BEDROOM 3 11 ft 0 149 ft2 ---- 1 0 0
5 Slab-On-Grade Edge Insulation CLST 3 1 ft 0 16 ft2 ---- 1 0 0
6 Slab-On-Grade Edge Insulation KITCHEN/DININ 26 ft 0 376 ft2 ---- 1 0 0
7 Slab-On-Grade Edge Insulation BATH 2 6 ft 0 72 ft2 ---- 1 0 0
8 Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 144 ft2 ---- 1 0 0
9 Slab-On-Grade Edge Insulation HALL 1 ft 0 39 ft2 ---- 1 0 0
10SIab-On-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ---- 1 0 0
11SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 56 ft2 ---- 1 0 0
12SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 9 ft2 ---- 1 0 0
13SIab-On-Grade Edge Insulation GREAT ROOM 14 ft 0 250 ft2 ---- 1 0 0
14SIab-On-Grade Edge Insulation FOYER 7 ft 0 112 ft2 ---- 1 0 0
15SIab-On-Grade Edge Insulation CLST 4 2 ft 0 16 ft2 ---- 1 0 0
16SIab-On-Grade Edge Insulation BEDROOM 4/DE 30.9 ft 0 158 ft2 ---- 1 0 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2049 ft2 0 ft2 Medium N 0.2 No 0.9 No 0 26.57
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1833 ft2 N N
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) M BATH 30 Blown 84 ft2 0.1 Wood
2 Under Attic(Vented) M W IC 30 Blown 126 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BEDRO 30 Blown 210 ft2 0.1 Wood
4 Under Attic(Vented) BEDROOM 3 30 Blown 149 ft2 0.1 Wood
5 Under Attic(Vented) CLST 3 30 Blown 16 ft2 0.1 Wood
6 Under Attic(Vented) KITCHEN/DININ 30 Blown 376 ft2 0.1 Wood
7 Under Attic(Vented) BATH 2 30 Blown 72 ft2 0.1 Wood
8 Under Attic(Vented) BEDROOM 2 30 Blown 144 ft2 0.1 Wood
9 Under Attic(Vented) HALL 30 Blown 39 ft2 0.1 Wood
10 Under Attic(Vented) CLST 2 30 Blown 16 ft2 0.1 Wood
11 Under Attic(Vented) LAUNDRY 30 Blown 56 ft2 0.1 Wood
12 Under Attic(Vented) AHU CLST 30 Blown 9 ft2 0.1 Wood
13 Under Attic(Vented) GREAT ROOM 30 Blown 250 ft2 0.1 Wood
14 Under Attic(Vented) FOYER 30 Blown 112 ft2 0.1 Wood
15 Under Attic(Vented) CLST 4 30 Blown 16 ft2 0.1 Wood
16 Under Attic(Vented) BEDROOM 4/DE 30 Blown 158 ft2 0.1 Wood
17 Knee Wall(Vented) BEDROOM 2 30 Blown 18 ft2 0.1 Wood
18 Knee Wall(Vented) CLST 2 30 Blown 3 ft2 0.1 Wood
19 Knee Wall(Vented) LAUNDRY 30 Blown 10 ft2 0.1 Wood
20 Knee Wall(Vented) FOYER 30 Blown 22 ft2 0.1 Wood
21 Knee Wall(Vented) KITCHEN/DININ 30 Blown 15 ft2 0.1 Wood
22 Knee Wall(Vented) MASTER BEDRO 30 Blown 21 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belowo
1 SE Exterior Concrete Block-Int Insul M BATH 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0
2 NE Exterior Concrete Block-Int Insul M BATH 4.1 14 0 8 0 112.0 ft2 0 0 0.2 0
3 SE Exterior Concrete Block-Int Insul M W IC 4.1 9 0 8 0 72.0 ft2 0 0 0.2 0
4 SE Exterior Concrete Block-Int InsuMASTER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.2 0
5 SW Exterior Concrete Block-Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.2 0
6 NE Exterior Concrete Block-Int InsuBEDROOM 3 4.1 11 0 8 0 88.0 ft2 0 0 0.2 0
7 SE Exterior Concrete Block-Int InsuKITCHEN/DI 4.1 11 0 12 0 132.0 ft2 0 0 0.2 0
8 SW Exterior Concrete Block-Int InsuKITCHEN/DI 4.1 15 0 12 0 180.0 ft2 0 0 0.2 0
9 NE Exterior Concrete Block-Int Insul BATH 2 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0
10 NE Exterior Concrete Block-Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.2 0
11 NW Garage Frame-Wood BEDROOM 2 13 12 0 8 0 96.0 ft2 0 0.1 0.2 0
12 NW Garage Frame-Wood CLST 2 13 2 0 8 0 16.0 ft2 0 0.1 0.2 0
13 NW Garage Frame-Wood LAUNDRY 13 7 0 8 0 56.0 ft2 0 0.1 0.2 0
14 SW Exterior Concrete Block-Int InsuGREAT ROO 4.1 14 0 12 0 168.0 ft2 0 0 0.2 0
15 NW Exterior Concrete Block-Int Insul FOYER 4.1 7 0 8 0 56.0 ft2 0 0 0.2 0
16 NE Garage Frame-Wood FOYER 13 8 0 8 0 64.0 ft2 0 0.1 0.2 0
17 SW Exterior Concrete Block-Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.2 0
18 NE Exterior Concrete Block-Int InsLiBEDROOM 4/ 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
o
19 NW Exterior Concrete Block-Int InsuiBEDROOM 4/ 4.1 13 0 8 0 104.0 ft2 0 0 0.2 0
20 SW Exterior Concrete Block-Int InsLIBEDROOM 4/ 4.1 12 0 8 0 96.0 ft2 0 0 0.2 0
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 SE 4 Metal Low-E Single Yes 0.3 0.26 N 9.0 ft2 1 ft 0 in 1 ft 4 in None None
2 SW 5 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 8 ft 0 in 1 ft 4 in None None
3 NE 6 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None
4 SE 7 Metal Low-E Single Yes 0.3 0.26 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None
5 SW 8 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None
6 NE 10 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None
7 NW 19 Metal Low-E Single Yes 0.3 0.26 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 441 ft2 441 ft2 21 ft 8 ft 13
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000297 1430.7 78.49 147.36 .1044 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Single SEER: 14 34 kBtu/hr 1020 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 40 gal 60.9 gal 120 deg None
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 140 ftz Attic 14 ftz Proposed Qn AHU CLST ---cfm 146.6 cfm 0.08 0.50 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
CoolingJan Feb ]Mar Apr May rl
Jun Jul X Aug Se Oct Nov Dec
Heatin �Xj Jan �Xj Feb lX]Mar f Apr f May Jun �xl
Jul f Aug 4 Sep Oct Nov X Dec
Venting [[ ]]Jan [[ ]]Feb [X]Mar [X]Apr [ May Jun Jul [ Aug [ Sep [ Oct [X Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 BATH 1
Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 1
Default(8 Ibs/sq.ft. ftz ft 0.3 DINING
Default(8 Ibs/sq.ft. ftz ft 0.3 KITCHEN
Default(8 Ibs/sq.ft. ftz ft 0.3 UTILITY RM
Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2
Default(8 Ibs/sq.ft. ftz ft 0.3 AHU CLST
Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2
Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3
Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3
Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2
Default(8 Ibs/sq.ft. ftz ft 0.3 HALL
Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER/GREAT RM
Default(8 Ibs/s .ft. ftz ft 0.3 BEDROOM 1
1/5/2022 5:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HUDSON 4 Builder Name: SYNERGY BUILDERS
Street: 430 SE GASPARILLA AVENUE Permit Office: ST LUCIE COUNTY
City,State,Zip: PORT ST LUCIE,FL,34983 Permit Number: Y
U
Owner: Jurisdiction: ST LUCIE COUNTY =
Design Location: FL,MELBOURNE_REGIONAL_AP U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit
Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a
Knee walls shall be sealed. material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to
(including maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation shall
and cantilevered floors) be permitted to be in contact with the top side of
sheathing,or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation
Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building
be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be
on exterior wall tubs shall separate them from the showers and tubs. insulated.
Electrical/phone box on The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub-floor,wall covering or ceiling
Concealed When required to be sealed,concealed fire sprinklers shall only be sealed
sprinklers in a manner that is recommended by the manufacturer.Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilincis.
a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
1/5/2022 5:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
430 SE GASPARILLA AVENUE, PORT ST LUCIE, FL, 34983
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1496.00 ft2
b.Frame-Wood,Adjacent R=13.0 232.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area
a.Under Attic(Vented) R=30.0 1833.00 ft2
6. Conditioned floor area(W) 1833 b.Knee Wall(Vented) R=30.0 89.00 ft2
7. Windows- Description Area c. N/A R= ft2
a. U-Factor: Sgl,U=0.30 124.00 ft2 12.Ducts,location&insulation level R ft2
SHGC: SHGC=0.26 a.Sup:Attic, Ret:Attic,AH:AHU CLST 6 140
b. U-Factor: N/A ft2
SHGC: 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 27.0 COP:1.00
Area Weighted Average Overhang Depth: 4.105 ft.
Area Weighted Average SHGC: 0.260
8. Skylights Description Area 15.Hot water systems
a. U-Factor(AVG): N/A ft2 a. Electric Cap:40 gallons
EF:0.92
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 1833.00 ft2 Credits(Performance method) None
b.N/A R= ft2
c.N/A R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Buildingrt srfi
Construction through the above energy saving features which will be installed (or exceeded) � _ 0
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ' Date: I -C-0 2 7 0 �
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/5/2022 5:14 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1