HomeMy WebLinkAboutEnergy Conservation Code ChecklistFORM R405-2014 L6 �, 11NI RESIDENTIAL. ENERGY CONSERVATION CODE l3DCUMEN;TATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with -the 2014, Florida Building: Coale, Energy Conservation via1he residential, Simulated Performance method, shall include ❑ `This checklist CI A Form R405 report that documents that the Proposed. Design complies with Section R4053 of the Florida Energy Code. This form shall include a summary page indicating home'address, a -ratio and the pass or fail status along with summary areas'and types of components, whether the home was simulated as a worst -case orientation; name and version of the compliance software tool, name of individual completing the compliance report (1 page) and an input summary checklist that can be used: for field yerii►cation {usually 4 pages/may be greater). 13 Energy:Performance Level. (EPL) Display Cam (one page) Mandatory Reodirements(threepages) RequiOd"prior 16,00 for the Perfonnance Method: Air-Banler and, Insulation Inspection' Component Criteria checklist (Table R402.4:1.1- one. page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405,ductleakage type indicates, anything other than "default leakage" -then a completed, Form R405 Duct Leakage Test; Report (usually one page) 81141201712:28:1 i PM Ene Gau e® - USRUS v5.1 K9Y 9 - Page 1 of 1 FORM'R4054014f FLORIDA- EFFICIENCY BUILDING CONSTRUCTION Florida DeDartmenf.d Business and Profession6l kegulation,n-ftesidiantial Pefformance Method Pfoject, Name: 'Ex -1 628bali LUCIE, R( llit LOT 108 Builder -Name: DR,HORTON. ,Street: 8604 COBBLESTONEPRIVE., Pirm4bitic'e': SAINT LUCIE COUNTY cky,-Stat#; zip*: FORT" PIERCE , FL-, 34945 Permit Numb4i: 1746-0229 Owner DR'HORTON .4urisdlqtion:'.SAINT:LUCIE'COUNT-7Y Design,Locatiolm. FL, P-1�,-ILUCIE-CO_INTI. 'ST. LUCIE'�Flo `da;Cilinat�r Zone 2 ty. n County;: I. kew cofistrtict.iori or,e)dsfin9New (FromPlans), -.9. Wall Types (1761.2,sqft.) . insulation. Area 2. Single,. family or multiple . family Singfamlly, a., Concrete Block - Int insul, E)derl or bFramer ri rne-�Wl : R=4.1' 1422-10 1 ' t' id i29.12 3. Mmber of units, if multiple,family 1 c. NZA R=1 R= 82 4. -,Num6er of Bedrooms 4, NIA R-- fiz 6. Is this a worst case? yes 10. Ceiling Types (1828.0 sqft.) Insulation ;Area & Under AttiolVehted). R-38.0 1828.00 ft2 6., CdndIti' edgoo�r'ar'ea'a''b'oveotadi�,(fn 1'829.'01403806 b. WA' ft2 Cohditioned1oofarea below q1r9de((fP) 0 V. R= ft2 11 ducts R, -*2- T Windows(168.1,-,sqft;.,) Description Area a. Sup: Attic. ket:,Attic AH: Whold-House 6 366.60.- a.,, U-Factor. , Dbl,,U=0.34 127:29 ft2 � Dbl. U=0.5740.80.ft2 1.2.,Coolin§ systems, kStulhr bkiency, SHGC: 91-16C6.32 -a. Central'Unk, 36.0 SEERA&M c. . U-Factor NZA ftz 13., Heating systems, kBtu/hr Eftlency d; U-Fictor WX ft2 -a. Electric Heat Pump 34.0 H8017:0.00 SHGC:, Area, Weiglited-Averabe,OVerhang pop 58 ft. th: i.71 ,Area Welgptad Average 'SI4Gd-. 0.312 , 14,Hot water systems 8. Pic 8 or Types �(l 28:0 soft.) Ins6lation' Area 8. Electric Cap.,, 0 .5 gallons a.Slab-On-Grade Edge -Insulation , R4.0 i$28.'001V b„ Consery otign,features EF: 0.950 b. WA 90 ft2 , None.' C. NIA R= 15. Credits Pstat Total Proposed:0Qd1fiedLoads: '58.91 Gla4*17lomAr6a: 0.092 PA510 T I'Baseline" Loads:' 60.16 I hereby certify that the plans and'speciftcaiions: cmered,by Review of the thts,mlWation Eire, pli co lia" 66 the Florida Enei�V =d s0ecifications' by this - Code calculatioh i6dicaties -coinobilce, with the Florida Energy.Code. FREPAREDZY:. Before con6tru6on is,00mpjetqd E. DAT this building will be inspected for :1 hdreby:dertify'ftt h I d, is in coiri Hindie. buildiridi;as'd &omplfaiice�wit6teictlon 553.008 RoM a With the,Florlda1m n ea QWNER/AGIENT BUILDING OFFICIAL: DATE:, DATE: - Cdin0limince,.:requi'r'Os,certifibatidn.by the air handler vnit:rnantA eturer.thifthe air handlerelnclosure, qualifiesas cerdfled"faPOry-sealed, in accordance with R403.1.2.1. . "Co mpliance, InsP ecOon'Checklist in accordance With A402.4.1.,Vancl an envelope` eakage testr6port in accordance with R402.4.1.2. Cdmpllince.with &' proposed ',duct l6kago:i2wrequ re94vDubt.Leakqqe Test.Re0ort confirming ng duct leakage to outdoors, '040 tested n acco,. ncowtth. 6.dfio'n.'803 of RES�NET StandirdS s not 906ati r tham(l. an for whole house. 811412017,12:28,15M EnergyGadgeO-USA .- F1aRes2014 Section R405.4.1: Compliant Software page 1 of 4 CADRA DAni;_,3niA PROJECT Title: Building Type: Owner: # of Units: Builder Name: PerMft.Office-.' Jurisdiction:" Family Toe": NewI&SVIN; Comment: Express 1,828,C41i LUCIA f 80drooffiv. 4 User' Conditioned Area. 1828:. DR "ORTON TotatStorles I Worst COW, Yes 'DWHORTqN' Rotate Angle: .225 SAINT LUCIE, COUNTY 6M6 Ventilation: - SAINTLUCIE.COUNTY Whole- HoLis e'Fan:' Siqg"Imily NeW:(Fr0m Plans) AddressType: Street Address 'Lot # BIodWSJubDiv.1sion.. PiatBook: Street. '65" COBBLESTONE County. ST.'LUCIE, Cfty,.Statb,,ZIp: FORT PIERCE, FL. 34945' CLIMATE, Design Location. 0EC-C Design -Temp 7MY Site, Zone 91.5 1/4 2.6'% Int Design Temp Heating Deilgn Daily Temp Winter 'Summer Degree Days Moisture Range F�L. ST:�UCIE�'_COJNTIL 'FL, 'CH-MPNI 2, 39 90 70 46 299 58 Medium BLOCKS Number" '­'Narne,- Area Volume, I Blockl 1828.014 16086.5 Number �N ark I ie Area, Volume Kitchen Occupants Bedrooms, Infil ID Finished Cooled Heated I Whole -douse 1828!0 14, '16086.5 Yes 5 4 1 Yes Yes Yes FLOORS 14 Floortyl;W' _Spade""' Perimeter R&Vislue 'Area Tile Wood Carpet, - 1,,SlabrOn4rad6-Edo Insul"6 - Whble House lgoft 0 1.*828 ft! 0.7 01 0.'3 ROOF V/# Roof' -Gable Roof Type Materials; Area Area Color Solar Absor.' SA. Emiki Emitt Deck Pitch Tested, Tested Insul. (deg) I 1p qqmpos1,Q9n;shinqlqs,-. 2044,112, 0 fe, 'Dark Hip No 0.9 No -0 26.6 "ATTIC Type Ventilation Vent Ratio (T I ri) Area. RBS IRCC I Full attic , Vented 300 1828 W N N. Cal [[no Type .1 A* Fm , mifig'Frac Truss Type, $04de R-Vab 1 6 Ins Tyjse I Uridef.Attic (Vented) Whole'House 3B Blown ' 1828 fe 011 Wood' 8/1412017-Al2,28PM Eher§yG;kUgeO.:.USA.-'FI,OR662014-See.fi6n:R40S.4.'l,C(im lantWtWare Page'2 of 4 CeNDRA OAnG-7MA WALES Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ _ 1 S=>NE Exterior Concrete Block - tnt'InsWhole House 4.1 18 0 &8 0 158.4 ft' 0 0 0.8 0 _ 2 E=>NW' Exterior Concrete Black - Int InsWhole House 4.1, 44 0 8.8 0 387.21? 0 0 0.8 6 _ 3 N=>SW Exterior Concrete Block - Int InslMhole House 4.1 39.8 0 8.8 0 350.2 ft2 0 0 0.8 0 4 W=>SE Exterior Concrete Block - lnt InsWhole House 4.1 59.8 0 6.8 0' 526.2 ft' 0 0 0.8 0 5 S=>NE Garage Frame - Wood Whole House 13 21 A 0 8.8 0 188.3 ft2 0 0.8 0 r 6 E=>NW Garage Frame -Wood: Whiole House 13 16 0 :8.8 0 140.8 0 0 0.23 0.8 0 DOORS Ornt Door Type Space Storms U-Value Width Ft eightin Area Ft In 1 S=>NE Insulated. Whole douse None: .4 3 6.8 20A fP 2 S=>NE Insulated Whole,House None .4 2 8 16 ft2 WINDOWS Orientation shown is the entered.orientation'(=> changed to Worst'Case. J wall Overhang Ornt ID Frame Panes- NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>NE 1 Vinyl Low=E Double Yes 0.34 0.31 2.5 iP 5 ft 0 in 2 ft 0 in None. None 2 S=>NE 1 Vinyl Low-£ Double Yes 0.34 0.31 31.2 W 1 ft 0 in 4 11.0 In None None 3 E=>NW 2 Vinyl Low-E Double Yes. 0.34 0.31 15.6 W 1 it 0 in 2 ft 0 in None None 4 N-SW 3 Vinyl Low-E Double Yes 0.34 0.31 62.4 W 1 ft 0 in 2 ft 0 in None None 5 W=>SE 4 Vinyl Low-E Double Yes 6.34 0.31 16.6 ftz 1. ft 0 in 2 ft 0 in None None 6 N=>SW 3 Vinyl I.owaE Double Yes 0577 0.32 40.8 ft2 8 ft 0 in 2 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 436.66 ft' 436.66 ft2 64 ft 8.8 tt 93 INFILTRATION # Scope Method. StA 'CFM 50 Ella EgLA ACH AGH 50 1 Wholehouse Proposed ACH(50). .00028 1340.6 73.59 138.4 .2097 5 NEATING,SYSTEM # System Type, Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump- Split HSPF:9 34 kBtulhr 1 sys#1 8/14/201712:28 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 COOLING SYSTEM - `System Type. Subtype. Efficiency ..06E��Y Air Flow SHR Block Ducts Cerdral-lUnit "Split SEER: %st 36 Muthr . 1080, crm 0.73 1 Sol HOTMATE,R-SYSTE.M, # Type 'SubTypo Location EF cap: use WPM Conservation ElectricI No_ne Garage- O.g5 50 gal 70 gal 120:deg None SOLAR 'HOT WATIERSYSTEM FSEC Collector Storage 6brt Corripdny Name Collector Mbddf# Area Volume FEF '','Ndne None fe DUCTS Return Ar 'CFM 25 CFM25 HVAC 0 'L--7,supp dcatlon R­VaW& Area Location Area Leeicage Type Handler TOT OUT ON RLF 'Heat Cool, 'Attic 6" 365.60.Attic 91.400 Proposed Qn Whole'Hou —0m., 73.1,cfM :0.04 0.50 .1 1 TEMPERATURES Programable rmostat:'Y Cdiliw ans:- Cobling Jan Heat -Jan WMar Mar a Apr, I Jul, m f May� Jun, Jun Jul- Aug R4 SOP I Wl Oct,, Oct, Nov W;N 6,t Dec Vent Jan ,H,Feb mar 'W,�Pr Apr MayJun Jul May Aug.Se ugSe. Oct Nov T4enpqstat',3chedyleHERS 2006,ftiference' Hours .Schedule Type 1 2 3 4 5 6 7 a 9 10 11 12 Cooling.(WD) AM PM 78 80' 78 "80 78 78. 78 78 78 78. 78 78.� 78 78 80 78 80 .78 80, 78, .80 78 Cooling..,(WEH) AM Pm' 78 78 78 18 78 78 78 7& 78 78 78 78 76 78 78 _78 78 78 78 '78 78: 78 .78 78 Heating -(WO). AM, PM 66, es 66, 66 68 68 66- .66 68 68, 68 68 68' 68 68 68 68 68 68 as' 68 66' as 66 Heating (WEH) AM, PM, 66r 68 66 66 68 M 66 66 V 68 68: 68 68. 68' 68 68 '68 68 _68 66 .68 66 .68 :66 8114MI71228 PM EnifgyGiiu§eO USA - FlaRes'2014 S.ecUon,R405.4.'l.,ComOtiaht:Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 98 The lower the EnergyPerformance Index; the:more:efficient the home. 8504 GOBBLESTONE DRIVE, FORT PIERCE, FL, 34945 1. New construction or existing New (From Plans) S., Wall Types Insulation Area a. Concrete Block - int Insul, Exterior 14=4A 1422.10ft2 2. Single family, or multiple family Single-family b. Frame - Wood, •Adjacent R=13.0 329.12 ft2 3. Number of units, if multiple, family 1 c. NIA R= fe 4. Number of Bedrooms 4 d. NIA 10. Ceiling,Types R= Insulation ft Area 5..Is this a worst case? Yes a: under Attic (Vented) R=38.0 1828.00 fe 6. Conditioned floorarea1e) 1828 b. N/A R= ft?, c NIA R= ftz 7. Windows'" Description Area, 11. Ducts R ft2 a. U=Factor: Dbl, U=0:34 127.29 ft2 a. Sup: Attic, Ret: Attio, AH: Whole House. 6 366.60 SHGC: °SHGC=0..31 b. U=Factor. ON, U=0.57 40.80 f12 SHGC: SHGC=0:32 12. Cooling systems kBtu/hr Efficiency a U-Factor. N/A ft2 a. Central Unit 36.0 SEER:15.50 SHGC: d. U-Factor. N/A ft2 13. Heating.systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.0 HSPF:9.00 Area Weighted Average Overhang.Depth: 2.758 ft. Area weighted Average, SHGC: 0.312 8. Floor Types Insulation Area 14. Hot, water systems Cap: 50 gallons a. Slab -On -Grade Edge insulation R=0.0 1628.00 ft2 a. Electric EF: 0.95 b• NIA R- 43 b. Conservation features c. N/A R= fe None 15. Credits Pstat I certify that this home has complied with the: Florida Energy Efficiency Code for Building Construction through the above energy saving featureswhich will be installed (or exceeded) in .this home before final inspection. Otherwise, a new ;EPL Display Card will be completed based on installed Code compliarit.features: Builder Signature: Date: Address of New Home: .--M(F KV 10b(gA /City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your'home• may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the. EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. for information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. `*Label required by Section R303.1.3 of'the Florida Building Code, Energy' Conservation, if, not DEFAULT. 8/14/201712:28 PM Ener9yGauge(D USA - FlaRes2014 -Section R4005.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of. Business and Professional Regulations ADDRESS: .8504 COBBLESTONE DRIVE Permit Nurriber.1706,0220 FORTTPIERCE , FL. 34.945 MANDATORY: REQUIREMENTS See :individ6all code sections for full details. ❑ 401.3 Energy Performance Level (EPL).display card (Mandatory). The building official shall require that an energy -performance level (EPL) display card be completed and cdrtifled by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 563.9085, Florida Statues] requires the EPL display card to be included as'an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains infoimation indicating the energy performance level and . efficiencies of components installed in a dwelling unit. The building official shall verify that;the EPL display card completed and signed by the builder accurately reflects the plans and. specifications submitted to demonstrate, compliance, for the building. A copy of the EPL display card can be.found in Appendix C. ❑ R402.4 Air leakage (Mandatory). .The building thermal envelope shall be constructed to limit air leakage in accordance with .the requirements of Sections•R402:1 through R402A.4. 0 R402.4.1$uildirig thermal envelope. The building thermal envelope shall comply with Sections`R402A.1:1 and R402.4.1.2. The sealing methods.between dissimilar'matedals shall allow for differential expansion and contraction. • R402.4.1.1 Installation: The components of the building thermal envelope as listed in Table R402.4.1.1.shall be installed in accordance with the manufacturer's instructions and the criteria listed_inTable402.4.1.1, as applicable to the method of construction. Where required by the code official,. an approved third party shall inspect all components and verily compliance. • R402A.1.2 Testing. The building or dwelling unit shall be, tested and verified as having an ,air leakage rate of not exceeding 5 air changes per hour'in Climate Zones °1' and-2, and 3 air changes per hour in Climate Zones -3 through 8. Testing shall be conducted with a blowerdoor at,a pressure of 0.2,inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an, approved third party. A written.report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any, time after creation of all penetrations of the building thermal envelope. During testing:' 1. Exterior windows and doors, fireplace and stove doors shall be closed; but not sealed, beyond the Intended weatherstripping or other infiltration control measures; 2.:Damp6rs including exhaust, intake; makeup air, backdraft and flue dampers shall be closed,, but not seated beyond'intended infiltration control measures; 3. Interior doors, if -instilled at the time of the test, shall be open; A. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooiiog.systems, if installed, afthe time of the test; shall be turned off; end 6. Supply: and return registersi If installed'at the time of the test, shall be fully open,, O R402.4:2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and. outdoor cornbusiion, air. O R402.4.3. Fenestration air leakage: WindoWs, skylights and sliding glass doors shall have an air infiltratioWrate of no more than 0.3 cfm per square`fooi'(1.5Us/m . andzwinging doors no more than 0.5, cfm .per square foot (2,6 Uslm2), when tested according to NFRC 400 or AAMANVDMAICSA 1�01II.S.2/A440 bycan accredited, Independent laboratory and,listed and labeled by the manufacturer. Exception:: Site -built windows, skylights and doors. O R402.4.4 Recessed lighting: Recessed;luminaires installed in the,building thermal envelope shailbe seated to limit air leakage between conditioned and unconditioned spaces. All recessed lurninaires'shatl be IC -rated and labeled as having an air leakage rate not more khan 2,0 cfm (6.944 Us) vlhen festedin accordance with' ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall,be•seated with a gasket or caulk between the housing and the interior wall or ceiling covering, ❑ R403.1.1 Therm+ostai.provision (Mandatory). At least one thermostat shall be provided for each separate heating. and cooling system. ❑ R403.1.3 Heat.pump supplementary heat (Mandatory). Heat pumps having supplementary eledrio.resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the:heat pump compressor can meet the heating.load. E3 R403.2.2 Sealing.(Mandatory)AII ducts, air handlers, and filter boxes and building cavities that, form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and seated in accordance with Section C403.2.1.2 of.the'Commercial Provisions of -this code and shall be shown to meet duct tightness criteria by post-canstrudion or rough4naesting below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in, accordance with Section 553.99; Florida Statutes, or as authorized by Florida Statutes, to be "substantially leak free" by either of.the following: 1. Post-constniction test: Total.leakage shall be less than.or equal to 4 cf n (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at ipressure differential of 0.1 inches w.g.= (25 Pa) across the entire system, including the manufacturers air handler enclosure. All register boots -shall be taped or otherwise'sested during -the test. 2. Rough -in test; Total leakage shall,be' less than or equal, to 4 efrm (113 Umin) per 100 square feet (9;29, m2) of conditioned -floor area.when tested at a pressure differentia6f a.1 inches w.g. (25Pa),across the system, including the, manufacturer's air. handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handier is not installed at the time of the test, total leakage shall'be less than or equal to 3 cfm (85 Limin) per 100 square.feet (9;29 m2) of conditioned floor area. Exc epptions: 1. The total leakage testis not required for ducts, and air handlers, located entirely within thebuilding envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 8114/201712:2&PM EnergyGauge@ USA FlaRes2014 - Section R405.4.1 Cam Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued). 13 11403.2.3 Buildhig.Cavitles (Mandatory). Building framing cavities shall not be used a5 duds or plenums. O R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 106OF (41°C) or below 55®7 03®C) shallbe insulated to a minimum ofR=3., R403.31 Protection of piping. insulation. 13 R403.4.1 Circulating hot water systems (Mandatory). Circulating hot wrater systems shall be provided with an automatic or readily accessible manual swDtch that can turn off the hot-vaater circulating pump when the system is not in use. 13 R403.4.3 Heat traps (Mandatory). Storage water, heaters not equipped with integral heat traps and; having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heattraps shall consist of elthera commercially available heat trap or a downward and upward bend of at least 3 % inches,(89 mm) in the hot water distribution line and cold water line located as,class as possible to the storage tank. R403.4.4 Water heater efficiencies (Mandatory). 0' R403.4.4.1 Storage wrater heater temperature controls R403.4.4.1.1 Automatic. controls. Service water, heating systems shall be equipped. with automatic temperature controls capable of adjustment from thelowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall befrom 100°F to 140°F (38°C to 80°C). R403.4A.1.2 Shut down. A separate:.switch or a,clearly marked circuit,breaker shall be provided to permitthe power supplied to electric service systems to Ibe turned off. 'A separate valve shall be provided to permit the energy supplied to the main burners) of combustion types of service water heating systems to be turned off. O R403:.*1Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table-C404,2 in Chapter 4 of the Florida Building Code; Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part.of a combination system shall satisfy all stated requirements for the appropriate water heating category:. Solar,water heaters, shall met the criteria Section R403.4.42.1. R403A.4.2.1 Solar water heaiing:systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy.factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar Collectors shall'be tested in accordance with ISO Standard 9806, Test Methods for Solar 'Coltectors, and SRCC StandsrdTM-1, Solar Domestic HotWater System and Component Test Protocol, Collectors in Installed solar water heating systems should meet the following criteria: 1. Be` installed with a lift angle 'between °10 degrees and 40 degrees of the horizontal; and 2. 'Be installed at an orientation within 45 degrees:of true south: (3 , R403.5 Mechanical ventilation (Mandatory). The.buiiding.shall be provided with ventilation that meets the requirements of the Florida Building Code, ResideneW or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation.. Outdoor air intakes and exhausts'shail have automatic or gravity dampers that close when the ventilation.system is not operating. p R403.6'Heating and coolDng'equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipmentsizing. Heating and cooling�equipment shall be sized.in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in•Section R302.1. This oode:does not allow designer safety fac torsi provisions for future expansion or.otherfactors Which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard.kitchen and bathroom exhaust,systems: R403AI14 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6; or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8114/201712:28; PM Energypauge@ USA - FDaRes2014 - Section R405.4.1 Corn Paget of FORM R405-2014 MANDATORY REQUIRIEME NTS - (Continued) 0 R4o3.6.1.1 'Cobil6g•equipmtnt"capacity. (continued) ;The published value for AHRi total capacity is a nominal, rating4est value and shall not. be used for equipment sizing. Manufacture's"expanded performance data shall be used to select cooling=ohiy equipment. This selection shall 6e used to select cooling -only equipment. This selection shall be base&dn.the outdoor design"dry. bulb temperature for the load calculation (or entering water temperature water -source equipment); the blower"cfm provided by the expanded performance data, ,the design value for'entanng wet bulb temperature and the,design value for"enterfng dry bulb temperature: Design values for entering wet•bulb' and dry bulb temperature shall' be forthe indoor dry bulb, and relative humidity, used for the load calculation and shallbe adjusted for return side•gains if the.retum'duct(s) isinstalledin an unconditioned space. Exceptions, 1. Attached single- and mufti -family residential equipment sizing may be selected so that its cooling capacity is less than the. calculated total sensible load but not less than 80 percent of that load., 2. When signed and sealed by a Florida-registe"red engineer, in attached single- and multi -family units; `the capacity of equipment" maybe sized in accordance with good design practice; 0 R443.6.1:2 Heating equipment capacity • R403.6,1.2.1 beat pumps. Heat"pumps sizing shall be, based on the'cooling requirements as calculated according to Section k403.6.1.1 and the heat pump to6( ooling capacity shall not be mote than 1.15 times;greater than the design cooling load. R403.6.1.2.2 Electric resistance. furnaces. Electric resistance. furnaces shall be sized within 4 kW of the,design requirements calculated according to the procedure selected in"Section 1140,16.1. R463.6.1.2.3 Fossil fuel heating.equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not beless"than the'desigri load,caiculated in accordance with Section;R4036.1. 0 R403.6.1.3 Extra capacity required for.special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major- entertainment events, shall have: equipment sized or controlled to prevent continuous space cooling or heating within that spade by one or more of the,following options: I. A separatecooling or heating system is.utilized to provide cooling or heatingto the major entertainment areas. 2. A variable capacfty.,system sized for optimum performance during base load periods is utilized. 0 R403.7 Systerrns'senring multiple dwelling units (Mandatory). Systems serving multiple dwelling'units shall comply .with Sections C403 and C404 of the Commercial Provisions in lieu"of'Section R403. p R403.8 Snow, melt. system.controis (Mandatory). Snow and ice -melting systems, supplied through energy serviceto the building,.shall Include automatic controls; capable of shutting. off the system when the pavement temperature is above.55°F, and'no precipitation is falling and "an automatic or manual`controi that.wiill,allow shutoff when the outdoor temperature is above 40°F. 1D R403.9 Swimming pools, fnground spas and portable,spas (Mandatory). The energy requirements for residential pools and ingroand spas shall be as speed in Sections R403.9.1 through;R403.9.3 and in accordance with ANSI/APSIDA 6. The energy requirements'forportable spas shall be in accordance with ANSIIAPSP-14. 0-R403.9.1 Pool and spa heaters. ,All pool"heaters shall be equipped with a readily accessible: on -off switch that is mounted outside the heater to allow shut ing off the heater -Without adjusting the thermostat "setting. R403.9.1.1 Gas and oil -fired poof and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum thermal efficiency of 82:perc entfor haatem manufactured omorafterApdf 16, 2013 +whentested in.accordance with ANSI Z"21.56. Pool heaters by natural gas or LP''gas"shall not have continuously burning pilot lights: RA03.91.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum GOP of 4:O,vrhen tested; in accordance with A14Ri 1160, Table 2; Standard -Rating Conditions -Low Air Temperature; A:te`st report from an independent"laboratory is required to verNy procedure complianc6. Geothermal swimming pool heat pumps are not required to meet this standard: O R463.9.2.Time switches. Time switches or other control method that can automatically turn off and on heaters�and pumps according to a preset schedule shall be installed on ail heaters and pumps. Heaters, pumps and'motors'thai have; built in timers shallbe deemed in compliancewith this equipment. Exceptions: + 1. Where public health standards'require,24-hour pump operations. 2. Where pumps are required,to operaWsolar and waste -,heat -recovery pool heating systems. 3. Where pumps, are powered exclusively -from on -site reneuvable„generation. 0 R463.9.37Covers. Heated swimming pools and inground permanently installed spas.shall:be equipped with,a vapor -retardant cover on -or at the water surface.or a liquid. cover or other means proven to reduce heat loss.. Exception: Outdoor pools deriving over 70.0erc ent of the energy for.heating from sfte-recovered energy,, such as a heat pump or solar energy source computed over -an "operating season. 0 RR404.1 Lighting equipment (Mandatory). A minimum of 75, percent of the lamps in permanently installed lighting;fixtures shall be high -efficacy lamps.or a minimum. of 76,percent of permanently Installed lighting fixtures shall contain only high efficacylamps. Exception: LoW-voltage lighting shall not be: required to utilize high -efficacy lamps. O 11404.1.4 Lighting equipment, (Mandatory). Fuel gas. lighting systems shall not have continuously burning pilot lights. C3 R405 2 Performance ONLY. Allductsnot entiriefy°inside the build! rig thermal envelope shall be"fnsulated to a minimum "of R-6: 0 R405.21 Performance' ONLY. Ceilings shall have minimum insulation of R-19.. Where single assemby of.the exposed deck and beam type or concrete deck -roofs do not have sufficent space, R-104s allowed. 81141201712:28 PM EnergyGauge® USA - FlaRes20114 - Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION "COMPONENT CRITERIA Project Name:' Express 1828. Cali LUCIE Right LOT 108 Builder Name: DR NORTON Street: 8504 COBBLESTONE DRIVE Permit Office: SAINT LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34945 Permit Number:1706-0220 Owner. DR HORTON Jurisdiction: SAINT LUCIE COUNTY Design Location: FL; ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and, thermal barrier A continuous air barrier shall be, installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable. insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any, dropped ceiling/soffit'shali be aligned with the insulation and any gaps in the air bamer shall be sealed. Access.apenings, drop down stairs or knee -wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the: junction of the foundation Walls and sill ,plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. `Windows, skylights and doors The.spacebetween Window/door jambs and framing and skylights and framing shall be sealed. Rimioists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantlevered floors) of subfioordeckiing. The air barrier shall be installed at any;exposed edge: of insulation. ,Crawl -space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth -in unvented crawl spaces shall be covered with a Class I vapor;retarde.r with:overlapping joints taped. Shafts, penetrations Duct shafts,.utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall -be cut to fit, or.narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided.between the garage and conditioned spaces. Recessed lighting Recessed light fixtures' installed in the building thermal envelope shall be air fight, IC rated, and sealed to the drywall:. Plumbing.and wiring Batt insulation shall. be cut neatly to fit -around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available .space shall extend behind piping and wiring. Showerltub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electricaltphone.box on The air barrier shall be installed behind electrical or communication. boxes or air sealed boxes shall be installed: HVAC register boots HVAC register -boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall -be installed on fireplace walls. Fireplaces. shall have gasketed. doors 81141201712:28 PM: Energy Gauge@) USA - FlaRes2014 Section R405.4.1 Compliant Software Rage i of i FLORIDkENERGY EFFICIENCY CODE, FOR .911ut L`01N ' G,,- C-ONSTRUCPON EnVellope,Leakage Test,,'Report Prescriptive and" " P6rformar . ice'. Method ProjectI Name. Express 1826Cali :LUCIERight LOT " 108 Builder Name.. DR HORTON Permit Offic6; SAINT LUCIECO COUNTY Street DRIVE U Co" State, Zip: FORT,PIERCE,'FL, 34945Permit Numbe!: 1706-0m, Design Location: .'FL & LUC' j N'TL Jurisdi6ti6rc SAINT LUCIE COUNTY Cond-Vaurnw.' 16081,'cu ft. Floor*qp:::1820'� sq.fi. 'EnvelpPe Le6Kq9p,Test.Resu lts, Regression. Data; C: ,n: Singlo,or, ultf06intT-est]D6ta HOUSE PRESSURE FLOW: Leakage Characteristics CFM(6Q):- ELAt EqLk ACH; ACK(6P): SLA: R402.4.1.2,Tintli4, The buildihg,or dWelling unit shall be tested, end veffied. a$ having an air Itakeop,rate .bf not exceeding' 5 alr..,changes per hour in fillin ate Zones I:and Z 3 air changes Oer.hourin Climate Zonis 3 through . S., Testing shall . beconducted :with a'6tbvv6rdoor .ataipibssuredfO.2, inches W400 Pas66lS)."whdr& peq6ired 6y4he code offidiI,AeitIng,ihail,b6 conducted OV ah,Approved third party, written report oftheresults, ofthe test shall be'signed, by the pai I party conducting the test i�d'piroivld' I ad tolhe-code ,official. Testing shall be,perfqrmed at,any,timeaft6r.6rbition.bf'alI penetrations of the . WidingAterryidl onvelope. During.te"nig; J.zExterior Windows ;and doorsi fireplace,6nd stove doors1hall be closed,. but nat sealed, beyond the. Intended weathetstrlippirig,orother, irifiltiatidWcontrol measures; ba&draft and.flue dampers shall be closed, but,not'seated beyond intended Infiltration � %'nnPtme!ISincluding exhta�e, m6keup,.Iir,. I Interior doo* if installed at the'tiftle of,thet6st shall be,open; 4.'Exterior .d6of&fbr 6nfinuous,ventilation systems a,ndfie.at recovery ventilators shalt be cloi; ad and sealed; S., Heatiriq,pno cooRlg,,sy.,sfemsi,O'In&t.Wled, at4fie, time of the test, shall be fumed off:,:and,,, ,6:'Aupply-and:rPtum raqlstirs,' if installed it the tiffmtest; t,,shall befully Open. I hereby certify , that_.,theabov6 envelope -leakage perfdrrranceresults demonstrate compliance _'d With Florida Energy o erequirbrri6ntsin accordance ,m(jihl;'i�4*n"k46i."'4'..'l,.2'.' SIGNATURE.. P PJNT9D ; NAMPE5 DATE: Where required bythe code official, 'testing shall `be ,conducted -bylian, approved ,,thlrd party,: A'wdften ,report of:th6l:re.sOlts,6f'th6�teit.sh6il' be signed - by, . th&'thirdpar't pcifidud,ting the test'and provided4o the co&'dfidai. BUILDING,OFFICIAL: DATE: 8/1412017 12:28 PIVI EnergyGauge&USA­:FlaRes2014 Section R405A.1,Cotnt)rtdnt.Software: 'PageA of I FORM R40 I 5,;-2014:Du0'jLqa'k04q Test Report —Performance Method FLO_ IMAENER,GYEFFI_CIENC, C ODE FOR BUILD!0N,STRj,CTION Form . R405- Duct Leakage Test Report Performance Method ProjecO 7M'me: Express 182t,CaIfLU619 Ridfi! LOT icis Builder Nibble:' VkHORTON Street Name: 'Express ­'. 1 1 , 11. 1. — street :8504 COBBLESTONE DRIVE Permit Office: "'SAINT LUCIE:COUNTY city, State,-, Zip: FORT PIERCE i.FL, 34945' Permit Number: 1'�M0220 fr beslin'Loicition: FIL,ST_,LUCIE_CPjNTL JUrisdicf1on,:, SAINT LUGIE COUNTY Duct Test.Time:': Post Construction Duct. Leakaae, Test Results ,tF'M'25'buCt-Leakagq TestVAlues Lim *Ptern, .Outside Dudt Leakage 1 System 1, dirri25(Out), 'Syst6hi'2 CfM25(4ut) 3 Systqnn,3 f'in*Out) �rn a 4, System 4 cfrh25(QuQ 5 Total House Duct, SystemLeakage Sum lines 1-4 Divideby (Totil Condiflon.ecifloor, Area) 1,certify tfie,tested; duct ,lbakagiL-,to.outsI de, On, ' is not greqeF., than the .proposed :duct .leakage Qn ,sp do 05=2014.­' SIGNATURE: MINTED NAME.' DATE: Duct tightnessshall be"vedfiOd by Aesfing,tpSection .803of the RESNET, S%njards-by,an energy rater certified in abcordance with. Section 56199" Florida�Statutes. BUILDING OFFICIAL: DATE: 8114/2017,112:28 PIVI EnergyGaugeD USA -,MaRes=4° 7- Section R405.4,4,0'ompliant S Page, !:of 1