Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code "Onlinesa ' Page l of 2 2017 r, '•� w - : tK.IS Home! ' fi l user RepShratl n - ibt Y ... .. o ... aP16 Suhmlt SuKharye ; Sp Puhtinuon5 ! . . ts. & Fetm_ nry�� FBC�ShR I: Bt75 site MaP I un{s l search l Product Approval _�. USER: Public User P[ffiuct Aeoruvai Men . > Product or AnalkAtIon � > ... . . .. AQnlTmtfoal,lit > Application Demo Fl. # FL17147-RI Application Type Reylslon Code Version 2014 Application Status Approved Comments Archlved L. Product Manufacturer Huber -Engineered Woods LLC Address/Phone/Emall 10925 David Taylor Drive Sulte:300 Charlotte, NC 28262 (704) 548-5442 kurt.koch@huber:com Authorized Signature Kurt Koch kurt.koch@hpber.com . Technical Representative Ken W. Hix Address/Phone/Emall 1446.FIwy 334 Commerce, GA 30530 336-3041 ken.hlx®f huber.bom Quality Assurance Representative Walker Campbell Address/Phone/Emali.' ' 1446 Hwy 334 ..Commerce, GA 30530 (704) 562-1053 ' walker.cam pbellO. huber.com Category Structural Components - Subcategory Products Introduced as a Result:of New Technology Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity ICC Evaluation service,'LLC Quality Assurance Entity" ICC Evaluation Service • Quality Assurance Contract Expiration Date 10/01/20i7. Vallttated By ICC Evaluation Service, LLC. " Certificate of Independence EL17147 R1 COI CertlOr wro of indena o v,; F i n Referenced Standard and Year(of Standard) year ICC-Evaivation Service'AC310 .. 2015 Equlvalence of Product Standards Certified By Approved Evaluation Entity ELI7147 RI Ea uiv AC310 odf - Section§'from: the Code �� Florida Building Code,OnIine P4ge'2 of 2 Product Approval Method " Method 1 Option C Date Submitted OB/31j2o15 Date. Validated 09/16/2015.. Date Pending FBC Approval Date Approved r09j20/2015 'of Products Model, Number or Name DescriptionZIP'System FAPpr (R) Wall Sheathing ZIP System (R) Wall Sheathing Use use in HVHZ:'Noall Installation Instructionsd.for d for use outside HVHZYes esistant: NoCreated M mr i �m�fa Verified By; ICC Evaluation Servlce,:LLC ressure: N/A by Independent Third Party: Other: limited.to structural aspects of panel P P Evaluation Re ports _ FL37147 RSA R-1474 f 1 Iv FL17147 Rl _ALE 9R1474 Ddf . 6atle Next . Contact 11j::3nd1 alafr The State of Florida Is an AA/EEC employer. [eevdehf tom-7n1� etorte Re^d Tbill^h- ^tiny Phen': P50.4a7.fe7i - �t e1 Flees ' ;: Pfl:mcv statement :; Ams�ihfllN eb rrr t :; .. -�la defend 4.temaat under Florida law, emall addresses are public remrds. R.you do niatwant your e-mail address reloaaed'h, response to a public -records u eleMonk mail to this entity. Instead, contact the office by phone or by traAtvonal mall. 1f u have an ref est, do not send - Section 455.275(1); Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must p vlde the peppaarriment with g5emit. address if they have one. The emaits provided may be used for oNidarcommunication with the licensee. However einali addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be maids available to the public - - datermin.. . - -'To f you are a licensee under chapter 455, F.S., please djo ick p, - - Product Approval Acoepts:. ® 'Credit Card . Safe httpS://wwW.#loridabuilding:org/pr/pr app dtl.aspx?param—WGEVXQwtDgvCo3EapiIlBd..:-4/12/2017 �• 1 . JS �. J 4� t- ....s'Y'.�' - �3. JCS. � :ZtPy�System®� 040_ & W��i' � •4 h"9 � . . R� f, ' ` r w _ She`athi , s � ISeles Dl�Ce ,10825s�evtd Taylor{Or'LSulte,'S001 Phone.�80Q-933=g22Q �' _ } '' ;____ ifCh'artottecNG28Z62 ''psyskti6lcoin ombB?iu6s Wooda�isd� r - `s't `•. � r + �FB�(;70.4 5479228' �'�� _�y` � �Fi2iaErSgrmsdW`m`ILrJ��Pbr�.yan"'tq ah and jM.Ne:.I.,G�e�mdaA�dyy�,�lt�ecro+�n�pb��re�gd�tr�dc„�alybf:� i..,,a.rw ` - _�Y Cl � � '�' ll i•. f IO�fE�1?�tleCdi�SV:ir•r9�68f��/'•un ��Id.: rfilaV.ml�_,R1CR 81Q_ I - ... - ' .dUBE� ENGINEEgEp Woans" ZIP:System®Roof & Wall Sheathing INSTALLATION MANUAL /?ysteM ROOF i 11M SMMMINp . Contents FASTER. TIGHTER. ENERGY EFFICIENT. 02 ZIP $ysfern® Sheathing Installation On Roofs 0I3 ZIP System® Roof &Wall Sheathing -: Window 03. :ZIP System" Tape. installation - Installation Flanged Windows Brick Mould Windows. Roof Panel Seams 09 ZIP System® Roof & Wall Sheathing : Window 04 ZIP System" Tape Installation - Installation Brick: Mould Windows (continued) Roof Panel Seams: (continued} 10 ZIP System® Roof & Wali. Sheathing - 05 Roof Covering Installation Instructions Penetration -Openings 06 ZIP System® Roof &Wall Sheathing Installation 11 ZIP System® Roof & Wall Sheat find Installation Details 07 ZIP System" Tape Installation -Panel Seams 12 ZIP System® Roof &Wall Sheathing Installation Details (continued) ATTENTION: This installation guide is intendedto .provide general Information for designer and end user. The following ZIP System Roof &Wall sheathing can be used with a range of exterior guidelines will help you safely and properly install the ZIP System• Roof & Wall claddings and roof coverings. Approved wall coverings include brick, vinyl, wall sheathing. We urge you,.and anyone installing this product, to stone, wood fiber cement, wood and cedar shakes, traditional hard coat stucco and specified dralnable EIFS read. there guidelines in order p minimize any risk of safety hazards and to prevent voiding any applicable applications, however it is not recommended for use with odheslMy attached EiFS. Approved roof warranties. This manual -is a general installation guide and does not cover every installation coverings Include asphalt -fiberglass shingles, metal files and panels, day and .concrete tiles, slate and siate=type shingles condition. Proper installation shall be deemed to mean the most restrictive requirement specified and wood shakes and shingles. Follow all cladding and roof covering manufacturer's installation instructions. by Huber Engineered Woods (NEW), local Building code, engineer or architect of record or other authority having ZIP• System Roof & Wall sheathing can be used jurisdiction. You are fully and solely responsible for all safety requirements and code compliance. For additional on buildings of Type III. (Roof Applications ONLY) and Type V construction and construction information contact Huber fngineered Woods LLc. permitted under the Md. ZIP System* Roof &Wall Sheathing Safety Guidelines Follow ZIP System• Roof & Wall Sheathing Includes; - ZIP System sheathing panels with built-in all OSHA regulations and any other safety guidelines and safety moisture barrier With preprinted fastening and tape guides practices during installation and construction. ZiP System tape - Use approved safety befts and/or harnesses or other fall protection equipment - Install ZIP System panels and tape only in dry conditions and on dry_. surfaces. Storage and Handling Do not install in rain, snow, frost or other slippery conditions. Set panel.stack on three supports (stickers) to keep off the ground. - Wear rubber -soled or other high -traction footwear while firstaping ZIP System ' Outdoors, cover panels loosely with waterproof protective material. sheathing in a roof.application. Do not wear footwear with wom soles or heels. Anchor covers on top of the stack, but keep away from sides and bottom - Ensure the roofing surface is free from oil, chemicals, sawdust, dirt, tools, to assure good air circulation. electric cords, air hoses, clothing and, anything else that might; create a In high niolsture.environments, cut.banding on the panel stack to prevent gipping hazard. edge'damage. - Install temporary toe boards along the ZIP System sheathing roof surface: ZIP System• Ro f & What is ZIP System• Roof & Wall. Sheathingl ZIP:System Roof & Wall sheathing is code -recognized as a wood structural panel, roofing underlayment (ICC-ES ESR-1473), water -resistive barrier and air barrier (ICC-ES ESR-1474). ZIP System Roof & Wall sheathing has a built-in moisture barrier that lets you say goon -bye to building paper or housewrap on the walls and felt paper on the root.* Simply Install the panels, tape the seams, and you have a structural wall sheathing; water - resistive barrier and air barrier or a structural roof sheathing and roofing underlayment all from one product. o WeU-Sheathing Notes and Limitations: Do not use on roofs with'slopes less than 2/12. Do not use abutted against general stone or masonry without providing a minimum of a 1/2' gap. Do not lnstali'ZIP System tape in temperatures less than W F ZIP System products are not recommended for manufactured housing appiications'that are built under a federal building code administered by the U.S.:Department of Housing and Urban Development (HUD). Do.not use panel edge dips (H-Clips) with ZIP System Roof & Wall sheathing Without expressed written approval from Huber Englneered woods." Do not use ZIP System tape to permanently serf around circular roof projections (plumbing vents, pipes, curved walls, etc.) Contents (continued) . Wail Coverings ZIP System Roof & Wall sheathing should be covered with the,fihished roof. covering or exterior cladding within 180 days of Installation. Finished roof. and exterior cladding products. should be' installed per the manufacturer's iristaliation instructions. Per the recommendation of the Western Red.6edac Lumber Association andthe.U.S. Forest Products Laboratory, wood siding shouid.be primed before installation. When original roofing or claddings are removed and replaced on existing ZIP System sheathing; the roof or wall should be covered wfth an additional: roofing.undedayment or water resistive barter priorto installationof the new finished roofing or cladding. Note: in cladding systems requiring muitipia layers of water -resistive barriers, like traditional hard -coat stucco, ZIP System sheQthing is intended only to replace the firstlayer. Wet Blown Cellulose Irisula can In addition to following manufacturer installation Instructions, we recommend a maximum moisture content of the cellulose of less than 25% measured at the inside suiface of the ZIP System panel before closing the will cavity. Sacondery.Coatings Do not apply secondary coatings or treatments to ZIP System Roof & Wail sheathing.parieis with the exceptionof-the following: NEW approved fire resistant coatings. Fire resistant coatings must be tested and approved by HEW for use with ZIP System panels. Field applied water soluble borate insecticide or fungicide: treatments applied -to the non overlay side .of the panel. See technical tip, °Termite Treatments an Z1P System Roof & Wall Sheathing,". on. zipsystem:cori for more information. Permeable laminated radiant barrier foil or paint For a radiant barter toil or coating to be considered permeable, it must have an applied perrriearice of five perms or greater as tested by the: ASTM E 96 wet cup standard. For radiant foil, the perneance evaluation would include any adhesive and/or backer used to laminate a:foik For a radiant pairiUcoati69, the perneance evaluation should be coridtided at the applied thickness of the painf/ceating. ZIP System Roof and yGall sheaftif replaces only the first layer, in mold uMedayment systems. " Edge support is not required by code with 12 (32/16 span rated) and N8 (40120 span rated) periarmance'category. sfisaftg 1 the tram ng does not exceed 24` d.c. and the Mo load does not exaeed 93 pal lot M and 156 psl for 5r8 performance categories. This is based on U180 deflection rlitada m total load. ZIP.System' Roof & Wall Sheathing installation Manual 02 ZIP Systeme Sheathing n'stallation on Roofs Overview: ZIP System Roof &Wall sheathing' :IS composed of ZIP System, panels and ZIP System sears sealing tape. ZIP System° Roof & Wall Sheathing panels should be' fully installed before the seam sealing tape is applied. In general; the ZIP System roof sheathing panels should be installed . fro m the lowest point: on the roof to the highest It is at the discretion of the installer whether to apply tape from the top down or from the bottom up.; However, working from the:higFiest' sections of. the roof and warldng down will minimize foot, traffic "on the tape., The folio sections steps are.presented as guidelines and.a general oiitllne of the installation process. These are manufacturer installation recommendations -please visit zipsystem.com fora library of flashing and.installation details. You are fully and solely responsible for all safety requirements Good construction and:eafnty nr—fi— �ti....ra s •._nL:.._� Step 1: Ensure that the panel surface is dry and dean of any nailsr sawdust, or. . other debris.or protrusions prior to installing or walking on the panels. • After erisurfrig 'compliance with all 'OSHA and local code safety guidelines, install ZIP System •sheathing panels with " the moisture 'barrier surface facing "outSide.:The long edge (8') should be oriented perpendicular to the framing members, and panels should'be installed 4' with the edge: seams staggered a minimum of 24•. 1.0 spacing between square edges of al] ad)adeht panels is recommended, In accordance with industrystandards for wood sheathing: (Tongue & Groove panels are designed-to.seif-space and,do not require manual spacing on the B. edges.) Step:2 .' = • Ensure that ZIP System panels span at least three framing members and a framing member supports the entire 4' edge: of the panels. Fasten the 21P System Roof & Wall sheathing panel to the framing members with code approved" fasteners spaced at the appropriate edge and intermediate spacing..IPis the responsibility of ihe.general contractor to verify proper fastener type and spacing prior to installation. Apply the fasteners 3/8' from the panel ends and comers. • An ideal installation would be where fastener heads are flush with the " panel surface. However, due ;o variations in materials and limitations on equipment, this may be difficult to achieve in some situations. It Is not "required to tape over overdriven fasteners. unless the fastener head creates_a holo through the entire panel. thickness. Please see the.technic l UPi °Overdriven. Fasteners in ZIP System Roof and" Wall Sheathing; for more information. Step 3. Instal( temporary toe boards as necessary when "applying the ZIP System " sheathing panels,up the slope of the roof planes. b' Panel Edges i The unique edge profile is designed to acc it modats Incremental panel expansion and does not require manual gapping along the 9' edges. 4' Penal Edges Maintain 1/a' space : where V edges: meet. Unique edge profile is on e' edges only. 03 ZIP System"' Tape. Installation - Roof Panel Seams APPIY ZIP System tape after all ZIP System Roof &Wall sheathing panels ere fully fastened to roof -framing members. Only ZIP System tape should be used to seal the seams of ZIP System panels. Ensure that the panel surfaces are dry and free of any nails, sawdust and other debris, or. protrusions. Avoid step"ping. on, tape in high temperature environments. ZIP System tape. is a: contact tape that requires pressure for an edequate:seaF Step 1. AppIy-ZIP Systehh'tapa to every vertical and horizontal panel seam. it is at th6 discretion of the Installer whether to apply tape from the top down PP Y P or from the bottom up. However, working.irom.the highest sections of the roof and•working down will minimize foot traffic on the tape. Ensure thatthe tape is centered over the seam within +/-1/2" to provide - adequate coverage and to ensure that wrinkles in the tape are minimized. Ensure that tape lengths are continuous across the B' horizontal edge of the panels. if splices are unavoidable, create an overlapping splice of at least T Apply moderate pressure onto the surface of the tape to ensure a secure bond between. the panel and the tape. "Use ZIP System tape gym or tape:roller to apply pressure'to the tape and smooth out any.wrinkles: Take special care to remove any voids andlor trapped air at splice areas and T4oints. Step 2. For,valley areas of framing, we recommend you use'6" wide ZIP System tape. This tape is wider than panel seam tape and Is designed to give you optimal protection in valley areas. Starting from the Bottom and working your way up; apply one continuous piece of '6' tape so that the center of the tape Is over the valley seam. Use the tape gun or tape roller to apply pressure to the tape to ensure proper contact with the panel and to eliminate any wrinkles that might have occurred In the tape. Take special care to seat tape completely Into the valley. Note: . . -. It is. important to pay extra attention to valley taping: as water is directed, toward the valleys during rain events. Self -adhering ice and water barriers, maybe required by code. ZIP . System tape is not considered a repikei man't.for self -adhering ice. and water barriers. Therefore; when self -adhering Ice and water .barbers are required, they should be installed in additlon to ZIP System tape. Step 3. IV ZIP System tape is riot available, use two continuous plebes -of 3.75- Zip'System panel seam tape over: the entire length of the valley seam, overlapping -the-places on the Valley seam by at least 1'.' • Starting from the bottom, Install the first place of tape overlapping the: valley seam' by at least 1 °. Usethe tape gun or tape roller to'apply pressure to.the.tapei to ensure Proper contact with the -panel andto eliminate any wrinkles that might have occurred In the tape. Apply the second piece of tape, overlapping the first piece in the valley seam by 1'. i Repeat use of the tape'guri.or rbller to make sure the tapelse dequately adhered and tightly pressed into the valley seam. Note: It is important to pay extra attention to valley taping as water is directed toward the valleys during rain events. - Self -adhering ice and water bOriers may -be required by code. ZIP System tape is not considered a replacement for self-adhering.lce. . and water barriers. Therefore, when self -adhering ice and water barriers are required, they should be installed in addition to ZIP System tape. StO..4. To -provide temporary we ather.protectlon to rootMall intersections I of dormers or other wood• h h s eat ed protection, apply 2 of the tape width up- the vertical projection from where it intersects with the riot. The remaining tape width can be adhered to the ZIP System roof sheathing panels. Use the tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. step S. Install ZIP System tape over hips and ridges by centering the tape over . the peak seam. Apply tape in sufficient length to completely extend the length of the hip or ridge. - Starting from, the lowest point of the hip and working up, press tape into Place keepingdape centered over the' hip.-ApplV moderate pressure . onto the surface of.the tape to ensure a secure:bond between the panel and the tape. Cut ridge tape as required, for ventilation prior to installing ridge vent. Step 6: Tape over toe board nail holes once the toe boards are removed, working from the highest toe boards to the Ibuvest 05 Roof. Covering installation Instructions ZIP System Root 8 Waif sheathing is a code recognized sheathing and underayment and is approved for: use with the following of coverings: -..Asphalt-fiberglass Shingles Metal Roofs (shingles and panels) - :Clay ile - Concrete Tile - Slate and Slate -type Shingles - Wood Shingles -. Wood Shakes conventlo ailing roof coverings, follow applicable codes and mariufacturer's.suggested' instructions. Some roof coverings require a slip -sheet. in addition to conventlonal underlayment. Where slip -sheets are:required, they should be Installed over ZIP System sheathing panels. Note: Visit zipsystencom for,updates and installation details. Asphalt -fiberglass Shingles Apply asphalt shingles directly to ZIP System sheathing: For roofs with a:slope of 2112 or greater but less than 4/12, additional underlayment maybe required. Install asphalt -fiberglass shingles according to applicable codes and mariufacturees:Installation Instructions. Metal Roof Coverings Metal roof coverings may be applied to ZIP System sheathing- provided that the roof covering manufacturer's Installation instructions and applicable codes are followed.. Fasteners used to: secure the ZIP System.Roof 8 Wall sheathing panels to. supporting framing must be compatible with the specific metal roof covering used. Galvanized to shall be used with galvanized roof coverings; aluminum -zinc coated fasteners shall be used with aluminum -zinc coated roof coverings and 300 series stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types. In addition, metal roof, flashing shall also be made of a material compatible with. the specific metal roof covering used. Apply metal shingle roofs with Slopes of 3112' or,greater. Clay and Concrete Tile Roof Coverings ZIP System Roof &Wall sheathing is intended to replace the frst layer in a two -layer or.miriti-layer underlayment system. When installing clay. or concrete tile roof coverings, follow the Installation recomrriehd' ations of FRSA/TR1073W. Instal[ file Installation instructions. roots according to applicable codes and manufacturers Slate and Slate4ype Shingles Apply slate and slate -type shingles on roofs with slopes of 4/12.or greater. Install slate and slate -type shingles acco installation instructions. rding to -applicable codes and manufacturer s Wood Shingles ZIP System. Roof '& Wall sheathing is Intended to replace the first layer of underlayment required b may by the IBC and/or the IRC. Additional layers of underlayment e required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater. Install wood shingles according to applicable codes and manufacturer's installation instructions. Wood Shakes ZIP System Roof & Wall sheathing is Intended to.replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of underlayment - may be required by code depending on the local climate. ZIP System roof sheathing is not to be construed as a replacement for interlayment. Apply wood d :shakes on roofs with slopes'of 4/12 or greater. Install wood shakes according to applicable codes and manufacturer s installation Instructions. VV ZIP: System® Sheathing Installation on. Walls Overview: ZIP System Hoof &Wall sheathing _is composed of ZiP System'pariels and ZIP System seam sealing tape. ZIP System° Root. S Wall Sheathing Panels should be fully Installed before the seam sealing.tape. is applied. The following installation steps are presented as a general outline of the installation process: These are manufacturer.iristallatlon recommendations=please visit zipsystem.com for a Library of flashing .and installation details. You are tall and solely responsible for all safety requirements. Good constructlon'and safety practices should.be followed at all times' Step 1. Install ZIP System Roof & Wall sheathin g.paneis, positioned' with the water -resistive barrier facing outside: The panels may be installed with the long side of the panel oriented: either horizontally or vertically to the framing rnpTbers. Walls that are designed to resist lateral shear.forces .and sheathed with wood: strUctirW panels .typically require solid framing, or blocking behind all panel edges, of oriented horizontally, block horizontai joints If wag is designed for bi icing or as a shear wall. 1/8' spacing between square edges of -all adjacent panels is recommended in accordance with industry standards for wood sheathing Installation. 8' Panel Ed 9es Panel Edges 4' Panel Edges 7. The unique edge profite is Maintain 1/a" space where Maintain 1/8' space designed to accommodate 8' panel edges meet 4 where 4' edges meet, Incremental panel panel edges; Unique edge Unlqua edge.profile 1e�ori expansion and does noF profile does not provide 8' edges only.' require manual gapping the full 1/8' recommended 8' along the edges.- :space in this situation.' Step 2. Fasten the: panels to the framing members. with code approved . . fasteners. Space fasteners 6' o.c: along supported edges and 12' ' o.c. at Intermediate supports,'pnless otherwise spebi ied by local code or the designer of record. It Is the responsibility of the general contractor to verify-prope'r fastener type and spacing prior to installation, Apply the fasteners 3/8'•from the ends and corner's. An ideaf installation would be where fastener heads are flush with the panel surface.. However, .due to variations -in materials and limitations on equipment, this may be difficult to:acbieve In:some situations: it Is not *required to.tape over overdriven 'fasteners unless.the fastener head creates'a hole through the entire panel thickness. Please see the technical tip "Oveiddven.Fasteners'in Zip System Roof and Wall Sheathing," on ilpsystem.cum for more information. 07 ZIP:System'" Tape Installation - Wall Panel, Seams Apply ZIP System tape after all ZIP System Roof & Wall sheathing panels are'fUl�ly fastened to wall fremiri 'members. Only Zip S stem to d be used to seal the seams_of:ZiP System panels. Ensure that the panel surface is dry la and free. of.sawdust and�dirt prior to tap(n0. ZIP.Syatem tape a tape that requires pressure for.ah adequate seal. contact e all seams using ZIP System: tape: Ensure that the tape.. _ entered over, the. seam within +/- 1/2"• to provide adequate rage and that wrinkles,ln tape are minimal. riand the ZIP. System tape gun or roller to apply pressure to the tape smooth cut any wrinkles. Step 2. Wherever tape splices occur at a horizontal or vertical seam, create. an overlapping splice of•at.least a". At T-Joints, the tape pieces should overlap by at least .i'.'Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape: Use the ZIP System tape gun or roller to apply pressure tc the tape and smooth out any Wrinkles. . Take special care to remove any Voids and/or trapped air at splice:. areas and T-joints. StepS. Tape inside and outside comer seams. Irslde comer seam ouWa comer seats ZIP System® Roof &-Wall Sheathing Installation Manual IT ZIP :System - Window -Installation DISCLAIMER:The foAoxdngsteps represent a general avennew for the proper instelladon'o . I Wndow flashing. please defer lolconsuft the installation instructions of your window manufaGurer as well as code requirements in yo6rluriadeon for full insialladon.detatls; Flanged Windows 1. Fasten the ZIP System. sheathing to the wood frame and install ZIP System tape to all wall panel seams, as detailed In sections 02 and 63. - i 7 � r f 2. ZIP System:tape may be used as pan flashing if installed in accordance with flanged window Installation details posted on zipsystem.com. Other adhesive -based flashing tapes (must meet ICC-ES'Acceptance Criteria for Flashing Materials (AC148)) may be used as pan flashing if Installed per ASTM 2112-07. Apply the flashing to cover the bottom of the opening, overhanging onto the sheathing by at least 2' and extending a minimum of 6' up each jamb. 3. Apply sealant around inside face of mounting flange. Sealant must be gapped. at the sill to permit drainage. Install and level window per manufacturers installation instructions. Verify sealant compatibility with window manufacturer. When using ZIP System tape as pan flashing, tiutyl, -100% silicone or polyurethane sealants are acceptable. Do not use latex or other water - based sealants. 4. Cut two pieces of ZIP System tape or another adhesive -backed flashing tape (must meet ICCilkl - E$ Acceptance Criteria for Flashing Materials (AC148)) and apply to each of the window jamb flanges, ensuring the jamb flashings .ovedap the sill flashing. Once the tape is in place, use the tape gun or roller to seal the flashing to the sheathing. S. Cut a iength. of ZIP System tape or another ad hesive-backed flashing tape:(must meet ICC- ES Acceptance Criteria for Flashing Materials (AC148)) and apply to the header, ensuring that the flashing overlaps the jamb Ilashings.' Once the tape is in place, use the tape gun or roller -to seal the flashing to the. sheathing. '00 NOT tape bottorn Rings 6. From the interior, apply low-pressure polyurethane foam (for windows] between the rough opening and the window frame. (Caulk sealant compatible with the, sill flashing may be used.at.the.sill if the .opening between the sill flashing and window i Is too narrow to allow the use of low-pressure polyurethane foam.) _. When using ZIP System tape, butyl, 100% t silicone or polyurethane:sealants are acceptable. Do not use latex sealants with ZIP System tape. If using another flashing tape, follow the flashing manufacturer's recommendation In selecting a sealant compatible with that flashing. Brick Mould Windows 1. Fasten the ZIP System sheathing to the wood frame and install ZIP System tape to all wall panel seams, as detailed in sections 02 and 03: 2. If recommended by the window manufacturer, cut a strip of wood to function;as a back dam at the sill. The wood slip shouldhave a length equal to the width of the rough opening and a height and width of at least 1/2'. Position the black 'at the inside edge of the window frame. NO ZIP System — 1NInCIQ1A/ Installation DISCLAIMER: The toUowingslepsrepresentegeneralti0ervewforthaproperhiyyapatlonolwindowfleshUig,plaasedeferldconeuil the insla0atkn ins Wcilons of your w ndow mehulaeNier ohd,sd as well as code requirements in your ctbrr for full Installat on data is Brick Mould Windows (continued) 3. ZIP.System tape maybe used as.pan flashing if installed in accordance• with brick mould window Cut a piece of rigid head flashing so that when Installation details posted on' zipsystem:cam. , itflush with the edges of the exterior Other adhesive -based flashing tapes (must meet• 'Insta"ed moulding of the window: Apply a bead of sealant ICAcceptance Criteria for Flashing Materials to the back and bottom surface of the rigid . (AC149)) may be used as pan flashing If Installed head flashing..Use sealant recommended. by the per ASTM 2112.07. Apply.the flashing to cover flashing manufacturer. the bottom of the opening, overhanging onto the sheathing by. at feast 2' and extending a minimum of 6' up each jamb. B. Secure the rigid head flashing to ZIP System wall sheathing. 4. For vertical jambs, cut ZIP System tape & another adhesive -backed flashing tape (must meet ICC- ES Acceptance Criteria for Flashing Materials (AC148)) and apply to each of the window Jambs, Ensure that they cover the entire inside of the rough opening as well as overfap onto the sheathing by at least 2". Flashing shall also extend above the �\ - ; 9• Cut a length of ZIP System tape or, another rough opening, such that it will project 1' beyond adhesive -backed flashing tape (must meet ICGES the exterior trim of fife window. Acceptance Criteria for Flashing Materials (AC148)) Once the tape is in place, use the tape gun or roller and apply to the rigid head flashing, ensuring that the adhesive -backed flashing overlaps to'seal the flashing to the sheathing. the Jamb fleshings. .Once the tape is in -place, use the tape gun or roller to seal the flashing to the'sheathing. 5. Apply sealant to Jambs and header allowing for drainage at the sill in accordance with window manufacturer's. Installation instructions. When using ZIP:Systemtape, use a butyl, polyurethane From the interior, apply low-pressure polyurethane or 100°/, silicone sealant Do notuse latex or foam (for windows) between the rough opening and other water -based sealantswith Z1P System the window frame. (Caulk sealant compatible with rb When using another flashing tape, follow the the sill. flasFiirgmay be used at the sill if the o enintape. P 9fiashing manufac-turer's recommendations :in etween the sill flashing and window is too narrow j selecting a sealant compatible with. that flashing. to allow the use of iowrpessure polyurethane foam.) When using ZIP System tape, butyl, I 000A silicone or polyurethane sealants are acceptable. Do not i i ' •' use latex or other water -based sealants with ZIP System tape. If using another flashing tape, follow 6. Install and level window per manufacturer's the flashing manufacturer's 'recommendation In installation instructions. selecting a sealant compatible with thatflashing. ZIP System - Penetration :Openings yowSCWIMEFI: The tallow n your judSftvon lo; futinste9agon Details. g steps represent B general overview for the proper instelletlan of penehat on fleshing. Please deter loPoor wR ur Lode requlrert ents in NULL ASSEMBLY zIP SYSTEMD WALL SHEATHING WOOD OR LT. GA. METAL STUDS 134NCH CAP RECOMMENDEDAT PANEL EDGES UNLESS . . OTHERWISE PROVIDED BY MACHINED PROFILED EDGES INSTALL Z1P SY6'TEAIS TAPED ( ABHESNE BACKED FLASHING (MUST C MEET ACi{a) W SEQUENCE FROM BOTTOM, SIDE$ TNEN TOENSURP TO' BACKED FLASHINGLNO LAP OF AQHESNE ZIP SYSTEMSTME OVERALLJOINTS IN ZIP BYS}EAjS WA L SHEATHW% OVERLAP TAPE A MINIMUM OF 14NCH AT AL T.)OINrS Vv USE FUW GEG ELECTRICAL. BOXES OR MEMBRANE FLASHING TO PROVIDE FLANGES FOR ELECTW CAL BOXES ' w' a� T shvMlcw weOO f>A LT, eL 11ErAL371®e. - 1GAF AETOIWONO6o AT PANEL PANEL TnaaehAAaea IM 25p= p�Es 1 mlY6TElyTAFFP4rNlm µOKP 6YSTEND SWAT APPPgH -OL E Ov06MTAPEA PRVMIN OF. ,�MATALLTJ . u ALLefyiTDWTAFEATALL FXTENpA CI)Rle 9 •. �jw FASMK1 IyPTDI0v 91FA11C1l6 A8 RECIXNm pY 5L%DM CDDE CORD OF lOAJL WALL ASSEMBLV .. .. .. ZIP SYSTEMS WALL SHEATHING WOOD OR LT. GA. META. STUDS IM4NCH GAP RECOMMENDED AT PANEL EOGESUNLESS ' OTHERWISE PROVIDED BY MACKNED PROFILED EDGES — INSTALL ZIP SYSTEMOTAPE OR ACHE SNE BACKED FLASHING tMU9T MEET ACI<6)WSEOUENCE FROM BOTTOM, SIDES; THEN TOP TO ENSURE SHINGLE LAP Of ADHESIVE BACKED FL/LSNIING - ZIP SYSTEMS TAPE iINSTALLEO OVER ALL JOINTS W ZIP SYSTEM® WALL SHEATHINGL OVERLAP TAPE MINIMUM OF 14NCH AT A L T,MIHTS USE FLANGED VENT HOODS `\ L Z!P System Sheathing Installation Details on Walls— visit zipsystem.com for. more details. WALL ASSEMBLY VINYLAVOODMBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH . . CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEM® WALL SHEATHING WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED.TO WALL SHEATHING WITH Zip SYSTEM® TAPE OR ADHESIVE BACKED FLASHING -'(MUST MEET AC148) CODE APPROVED FLASHING FOUNDATION,--, wALL:AsbEiu�r (INSTARCEMmC 6CW0 ACACRIANCE WITH. INSTALL INSTALLATION REACAURSDA ZIP SySrEIO WALLSMEATHI TION4). DPSY'B RLT. WALL YA"TUDS 'NG RING OFIIT, CA METAL STUDS LAL�NOFD AT PANELUNLEBS - .. GMERWISE PROVDEp BY �, YALNRIEO PRO}$ED EDGES ZIP F OVER ALTLEjGTAPE (WSSySTEn DYERSHEA 9 W aPSYBTFJLO WALL 6HEA1NWG1 Y 4' OVERLAP TAPE A MYAMLIMCF IiNCH ATALL T~$ PANELEGAP COMMENDEOAT. \ NLESS OTHERWISE PROYOEG BY NACNWEO PRCFLFD EDGES FASTER 2p M WALL SHFATXWGASREOUWEDBY DESKWERGFaLSCORO CA LOCAL BUIDWGCODE ----------------- Note• For 1 i' WALL ASSEMBLY BRICK VENEER AIR SPACE (AS PRESCRIBED BY LOCAL BUILDING. CODE) ZIP SYSTEM® WALL SHEATHING WOOD OR LT. GA, METAL STUDS TOP EDGE OF FLASHING TAPED WITH ZIP SYSTEM® TAPE OR ADHESIVE BACKED'FLASHING. (MUST MEET AC148)' CODE APPROVED BASE FLASHING- ' IWEEP HOLES (AS PRESCRIBED BY LOCAL BUILDING COPE) WALL Aars'um BRICK VENEE AIRSPACE (AS PRESCRIBED BY LOCH. BUBORtG COOE) LP SYSTEMS WALL SHEATHWB WDGO,OR LT. GA METAL STU0.5 7/B-INCH OM RECOMMENDED AT OTHERWISE EPRovIG MACHINED G MACHINED PROFILED EDGES � AP SYSTEAID TAPE (INSTALLED OVE R ALL JOMS IN 21P SYSTFJiS WALL'SNEATHW% . OVERLAPTAPEA WWtMIjw OF 1•INCX ATALLTJOWTS ' =CN GAP RECOMMENDED AT PANEL EOOEg UNLESS OTHEfNASE PROVIG W BY NACHWED PRGF%ED EDGES FASTEN ZIP SYSTEMO WALL SHEATHING AS REOUIRED BY DENGNER-0F•RECORO OR LOCAL BUILDING CODE opttme a r leakage reduction, all untaped edges of the panels can be caulked, gasketed or, sealed with a weather stripping material. ZIP Systemm Rod.& Wall Sheathing Installation Manual 12 ZIPSystem Sheathing Installation Details'on Walls (cointinued) WALL BEYOND. ' WALL ASSEMBLY M71 BACKDAM PER WINDOWBRICK VENEERMANUFACTURER'S INSTALLATIONAIR SPACE (AS PRESCRIBED BY RECOMMENDATIONS:—� LOCAL BUILDING CODE) ZIP SYSTEMS WALL SHEATHING :WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC148) CODE APPROVED FLASHING WEEPS (AS PRESCRIBED BY LOCAL BUILDING CODE) — STEEL LINTEL' INSTALL WINDOW IN ACCORDANCE WITH DETAILS 24A-24D OR 25A-25D . WALL BEYOND WALL ASSEMBLY CODE APPROVED CLADDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S IN$TAL LATION' RECOMMENDATIONS) EXTERIOR RIGID INSULATION DRAINAGE'PLANE (MIN. Y") ZIP SYSTEMS WALL SHEATHING WOOD OR LT. GA. METAL, STUDS TOP EDGE.OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM@ TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AC7481-:-� CODE APPROVED FLASHING INSTALL CODE -RECOGNIZED SILUPAN FLASHING IN ROUGH OPENING PRIOR TO WINDOW INSTALLATION. TOP EDGE OF FLASHING TAPED WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. (MUST MEETAC148) — WEEPS (AS PRESCRIBED BY LOCAL BUILDING CODE)—=—� CODE APPROVED FLASHING WALL ASSEMBLY BRICK VENEER AIR SPACE (AS PRESCRIBED BY LOCAL BUILDING CODE) ZIP SYSTEMS WALL SHEATHING WOOD OR LT. GA. METAL STUDS IFOUNDATION Note: For optimal air leakage reduction, all untaped edges of the panels can be caulked, gasketed. or sealed with a weather stripping material. F. . _' .. +ai •,f ylr- ar 7.. -•+�., � MI'.+' '_,S�+T r'.' l �t .. , k• � ., w' _� ..,e+„'•. • R> � y - sue. t : t,., �,,�+'„ it _ t .. - i • - .- sip ,j .• - ' - ` -r .. `f , a .ram?-Q�.�y:� r r ,,R n � { •T . , T� t. a,, y:v ��'�'i yCt i,.� �s.H y r tY� ,` ., s r !vr �,, aC y�Jf►A •�`7 .. ». ' ** ;` � t3 . .. a * i � ;, ti a.��' R r ':hoc s<r ;�. 1,�. ' `•;r,+ •+'�4"•�' vT t ♦ r+, �� •TaYY; �' ♦ a4x yk }�� _ , t KAv s 4 } .ay ! = i *�, .� •ems_ .i.,., 1 r4i� r 4♦►h'.'7 ,``j r iP•.•p.� ?i, ' tf:",t '.�.:•}'�i.y��`',,, :.'�r-'.♦ - v"�.t�"., ^x 3 ._ •,. '' t ''i k e•.', i,-rt 4, r .♦. d � •n i � r r? i Z,^t � r: i- - •`� S, .'y� 4j i„i rRji . �'ilS�f�i TF !"^ qr +.:`i K , -?I s.. + '!•i .r ri r �•f#. sv AM ., - .... .« .� .{ • iL ♦ M tA' dtr r.♦ 39�s .1r��K k' �^a� , afi.i ♦ #. �•?4 �vtl t ..T - y• it r ^ ♦ r rt - '''vc d"''n . r .rt•.,, aTLi r'y., it, F »'". !+k* fir. `* -.. `r+t ■,,;r ry '# yy+Iw`+r4 . ,� r ' t ,r.. .•�• x ` S '� t Y �.. t r T .,R�' �._.;� } a.: k:♦ �• '..a♦ +i }'r�1`: `i�R� ,,�� r'S+".R t,�t t t! ! ., fir. T? � 1! '.Y K�� ? r s4m++rrr+K : Y " cF" L r1q T'` r �,rri P"il • p'f x .,. -t �• sTi ..-'�5a.'4^ r-. � Y > � �+ ti �' �.'�•t y� « ..»a- ' rS ?aa � J t , . ' rev.. . ^ r ' ' Y t n ♦ r t i � �a O: rt_ r • �` T � °' C ±r �-�A•,�•A - i T°Wrp i�t� x �� r * �yr r . •At'h iT; � r �'�.� �� ,F • � T '•r _::r' `M "�� T+4�y. ,}.��y E } w d { ,� � #A.et• ri~ a �'" �✓ti_ i. .k»• a ' .�`y�.} -'�t� +, r i1� t♦ tj �•P"" , + s. . x ' ' T#a•- � 'y.: 'i'a a .. � klr"' � *?<ps '>+ � "�,iy,"�.�}; `•, ��� *t,�tik g T•re e�,,,y,fA.'r 34 L `r...,.r CT'a.1� ry � . ♦„ + ♦ <a R +kr'_ f." �,'".:T�.�.,j'`y.', .,�:ar'^ ar lr t t 4 ✓ i+. r ,.• s�, ? � � *y .`. .'.T.,,,3,df"'-^ 'r s � r i � . � s c- l' -. • ✓f �' ;9 ♦•r �ff{i _ , `.Vr-x !y �� 11 y� i�f 4� '1 T" t ) }' =F fY 1W �{. i .'TS .1 ) ! +tom y •,' ! ii. , t � ♦ *ta P �f '4Y i?" •iir�! 3..a� ` 7 i i y. � 4N'y „ ,t < r k -• S >r� r � : �3 's`�d's+ �i .dx� � "iro'w �r �L r i'•rv` .k� i• � ap• �,� - •, s � . , p,. r. ♦ i � s r � t �. s+f;.b*.# ..a've ? a r ,t �•+, � .. . ra � ::2kt rs y.<; �-�. •s' ♦{.sit � L t `*.' r w ?� et+. ��i*s' .,. �+.,y,, t•a r 'r'��{�.{.,-,a f i <$q��e�� .-ti[`�=a iy'�r+ +' �< ;.� � � . - + t.' .' i. .' `-^ � art r • t1 w s �„�r. �y +�r� • y M i� iQ�. "�' .•` � ,r _'�C�..♦ �t I •? +� • , s S - ••d. i x,� � '. h8 Y•:3Y. ti < t• "!� s 1 �. .+` � 5 S.a.v r �.,✓ai, +, .� • - - r - i .• � r n � t.. '`- , '�"i ��Ii,T i" ;A!. 4�e♦ } SX r Ar's /,r, � r °? i w M .. �/,a �' e" ' _.: I'`F .��✓# y� yy g�,T` ya�y'r }` 1 L� � i .+t `a+ ?�,. d.�.� d 3aXni'Sb"t , z" &-1n�ir� �r%4t F r� •.ycs « ,` 10, 3 ; e, " ♦f r a� 1L': pr r •�'`` + `- a �"" 4 a y+.,• ' . > � -�♦-; a 4 7'-R�' !'-i�yy�y.� r �' a is p,,T T �♦ � '�' `. '_' � '��► C * �,$+�;n ��t r, aF• r ' , -. �''.: .. � �..:. d�1.r`... � a �.� �'� ti .- � 'r a � � �P' t .= r x + t ^' r F t:. •+ , �L$!r ` st + • [, ',ax. •�sy v� a'�. R+,�. f�y+•.iai r.�r df... ♦ � , 'h J "151ie fin Orr -'` y, f4t F �7� `�,,� w• a r i j.s�, r ..'p- H'r'} u ?� a .fie R My i� ✓ S6 .a. rf } yi {'► G_. >r.c tf :i z '`ss•� +k : i} • '° .': t> �7 �1 u ; ♦ s y e � r... - i x," . a • i. « x :=ram r - 9 - ^y . + a - •Er +✓fir` 4r x �'. 4. { r'•y, _q,y, i t `•' .j; _t.�+� x ` + ♦ • ? r kr �,� ,.5�.;,aNtrl�.,,fnc.,.pa,,� < 'Y�>..a�t,+6,.,.a �i i'�r''�4't ''° '� a•`' ii r w wh>. tryj, rY � n, ' ti_ •,r ., v� ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION:A H"2 TRADITIONAL HARD -COAT STUCCO. INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LATH OR THE PORTLAND CEMENT ASSC. (PCA) RECOMMENDATIONS WITH THE MOST • =• RESTRICTIVE CONTROLLLINO. ONE LAYER OF WATER RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUNALIE NT TO GRADED ' BUILDING PAPER. ZIP SYSTEMS SHEATHING' t., . TOP EDGE OF WEEP SCREED ; -''•`'"• TAPED TO WALL SHEATHING •�• WITH ZIP SYSTEM® TAPE OR •' ADHESIIlE.BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) ' WOOD OR LT, GA. s METALSTUDS ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (]JP SYSTEM TAPE MAY 'BE USED AS \ THE BRIDGE FLASHING) L— CODE -APPROVED WEEP SCREED AT BASE OF WALL VERTICAL AND HORI7NEEDED. CONTROL JOINTS AS DESIGNER-0OF-RECOSPECIFY TYPE AND LMASONRY BLOCK WA ZIP SYSTEM® SHEATHING IS APPROVED TO REPLACE. ONLY THE FIRST LAYER OF A TWO -LAYER UNDERLAYMENT.SYSTEM; DRAWING_NOT TO SCALE �I�sysinTM Sales Office:.10925 David Taylor Drive Suite 300: Charlotte; NC 28262 �UVENGINEERED SHEATHING 8 TAPE Telephone: 800.933.9220 - www.zipsystem,com 11 �J WOODS These construction etails are provided to assist.in a instal a ono I ystem product s) an may'not apply to every situation. Manufacturer accepts no responsibility or liabllity for the use of these or other coriStruction details. ZIP SYSTEM® SHEATHING WITH HARD'COAT STUCCO AT 'BLOCK FOUNDATION WALL -OPTION A H-2 WALL ASSEMBLY TRADITIONAL HARD -COAT STUCCO METAL LATH ONE LAYER WATER-RES. BARRIER 21P:SY$TEM�1 SHEATHING* WOOD OR LT. GA. METAL STUDS TOP EDGE OF WEEP. SCREED TAPED TO WALL SHEATHING WITH2IP.SYSTEM0 TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) CODE -APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED. MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP SYSTEM / - TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL LATH TOP EDGE OF WEEP SCREED TAPED TO WALL. SHEATHING WITHZIP �\ SYSTEM® TAPE OR ADHESIVE BACKED FLASHING.:(MUST MEET AAMA 711 OR AC148) ... TRADITIONAL,HARD-COAT.ST000O \ INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S OR THE PORTLAND CEMENT ASSC. (PCA) RECOMMENDATIONS WITH THE MOST RESTRICTIVE CONTROLLLING. ' ONE. LAYER: OF WATER -RESISTIVE . . VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT -LEAST EQUIVALENT TO GRADE D BUILDING, PAPER. COD&APPROVED WEEP / SCREED AT BASE OF WALL . . ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP SYSTEM TAPE. MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL 'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO -LAYER UNDERLAYMENY`STEIyIqT TO SCALE Sales Office:10925 David Taylor Drive Suite 300 - Charlotte, NC.28262 Wsand ENGINEERED SHEATHINGBTAPE Telephone:_800.933.9220-www..zipsystem.com WOODS ese construction etails areprovide to assistin the' instal atlon o IP. ,ystem pot apply to every situation. INaqufaCtUrer accepts no responsibility or liabifity for the use of these or other construction details.