HomeMy WebLinkAboutTamko Building Products LLCMIAMI•C1ADE
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF _ACCEPTANCE(NOA)
www.miamidade.gov/economy
TAMKO Building Products LLC
220 West 4th Street
Joplin, MO 64801E
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Con"] Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)_
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revolve this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with. the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product..
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT.- The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date Wray be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entiretv.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official_
This NOA revises and renews NOA No.1.9-1107.04 and consists of pages 1 through $_
The submitted documentation was reviewed by Freddy Semino
NOA No.: 20-0701.02
MEi 143ADECOUIITY Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category;
RoohnR
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deem Tye:
Wood
SCOPE
This approves TAMKO's Heritage, Heritage Woodgate, Heritage Premium, and Heritage Proline Titan XT
asphalt shingles, manufactured by TAMKO Building Products LLC, as described in this Notice of Acceptance and
designed to comply with the Florida Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Heritage 13 'W' x 39 3Ig" TAS 110 Dimensional asphalt shingle.
Manufacturing Location # 1, 2, 3
Heritage Woodgate 13 '/a" x 39 3/g,, TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1,3
Heritage Premium 13 '/4" x 39 3Ig" TAS 110 Dimensional asphalt shingle
Manufacturing Location ## 1, 2, 3
Heritage Praline Titan XT
Manufacturing Location # 3, 4
13 '/a' x 39'/s" TAS 110 Dimensional asphalt shingle.
MANUFACTURING LOCATIONS
1. Dallas, TX
2. Tuscaloosa, AL
3. Frederick., MD
4. Phillinsbum, KS
NOA No.: 20-0701.02
MMMADF couHrr Expiration Date: 12/01/25
' Approval Date: 11/05/20
Page 2 of 7
EVIDENCE SUBMITTED
Test Aency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
TAS 107 & UL 790
04CA44252
02/25/05
ASTM D3462
02NK33813
09/23/02
ASTM D 3462 & TAS 107
R2919 Letter
03/10/11
ASTM D3462
4789110543
08/26/14
TAS 107
02/19/15
ASTM E 108
08/26/14
ASTM D3161, Class F
4787043752
10/20/1 S
ASTM D 3462
4789650787
10/12/20
R 2919 Letter
10/15/20
ASTM D 3462
4789682154
10/15/20
PRI Asphalt Technologies, Inc.
TAS 100
TAP-129-02-01
05/26/05
TAS 100
TAP-130-02-01
05/26/05
TAS 100
TAP-131-02-01
05/26/05
PRI Construction Materials Technologies LLC
TAS 100
TAP-303-02-01
12/12/14
TAS 100
TAP-307-02-01
02/10/15
TAS 100
TAP-317-02-01
09/02/15
NOA No.: 20-0701.02
F-1alIe-.1 ECOutrrr Expiration Date: 12/0ll25
` Approval Date: 11/05/20
Page 3 of 7
LIMITATIONS
L Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shingles shall not be installed on roof mean heights in excess of 33 ft.
3. All products Iisted herein shall have a quality assurance audit in accordance with the Florida Buildiniz Code and
Rule 61620-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shalt be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard. RAS 115.
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail `A', attached.
5. Nailing shall be in compliance with Details'B', attached.
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below.
K"4M DADS CI0UNTY
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
NOA 1Vo.: 20-0701.02
Expiration Date: 12/01/25
Approval Date. 11/05/20
Page 4 of 7
DETAIL A
HERITAGE HERITAGE 4iJDGAT ... HERITAGE--PRrNll HEMA.GE.
PROLINE TITAN XT
All dimensions are in inches.
5TH COURSE
4TH COURSE
3RD COURSE
98
-� 2Ni] COURSE
-- 23
�_ --- - 1ST COURSE
DETAIL_B
HEmAGE HERITAGE WOODGATE HERITAGE PREMIUM AND HERITAGE
PRouNE DTAN XT__SHLN__+GLE
FIG: I EASTENING PATTERN
All dimensions are in inches
f - 39-318"
BI< 7I� 71/27 �I� 731a�\!< 7'/z" >< 7��2 IH 13-if4r
------------------------------- ---------- 11--------------- --------------- ----
• • • • • •
6-118"M I
Exposure
NOA No.: 20-0701.02
MiA471 ERDE COUNTY Expiration Date; 12101 /25
Approval Date: 11/05/20
Page 5 of 7
DETAII. $ (CONTINUED'
HERITAGE HERITAGE WOODGATE HERITAGE PREMIUM AND HERITAGE
PROI.INESITAN XTLHTIN-GLE
F G 2 AL TERNATE FASTENING P-ATTERN
i- — -- - - - - _ . 39-3/8" — . - -- _ --- - — --- -- a
HERITAGE SHINGLE
(TUSCALoosA, AL)
FAG. 3 ALTER PATE FASTENING PATTERN'
HoRIzONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG. 2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHLN NAIL ZoNE.
PAINT
LINE.
7-7/8"
0 Common Bond
L ZONE
6-1l8" f s -,--EDGE OF
COMMON
BOND
EXPOSURE
�J"Jf 8rr
ACCEPTABLE
FASTENER LOCATION
.- DO NOT FASTEN
-- ALONG ON BOND
PREFERRED
FASTE NE R
LOCATION
NOA No.: 20-0701.02
Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 6 of 7
HERITAGE: PROLINE TITAN XT SHINGLES
FIG. 4 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG.1 OR FIG. 2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHLN NAIL ZONE.
�.._µ ... ,� .. .. . .. ., .. . Nail Zone
Paint Lines
Exposure
39-3/8"
Acceptable Fastener Location
Preferred Fastener Location
END OF THIS ACCEPTANCE
NOA No.: 24-0701.02
Expiration Date: 12/01/25
Approval Date: 11/05/20