Loading...
HomeMy WebLinkAboutFlorida Bldg Code 7th Edition<`1 LLcLL i_' ► . LUCIE.. ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Rewired See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RA5 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D I A4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D Wood Shingles and Shakes A, B, D 12,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RA5127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7, Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: License# CCC t-322912, � Jatr Address { io e}3 �r�i n�_Y_ ` A *4 G f - .� C� � � ��.�r� I �a v ROOF CATEGORY 0 Low Slope ❑Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles ,P11sphaltic Shingles ❑ Metal Panel/Shingles DWood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair © Maintenance Reroofing 0 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SM<=3- Steep Sloped Roof Area (SF) Total (SF) -_r Section B (Roof Plan) Sketch hoof Plan. Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 13 36 Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Max. Design Pressure, system: Deck: Gauge Thickness: Zone 2: Zone 3: n the specific product approval Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':- " oc @ Lap, # Rows_ ___ "oc Zone 1:—" oc @ Lap, # Rows '°or Zone 2:._._." oc @ Lap, # Rows @ "oo Zone 3• " oc @ Lap, # Rows____ @ " Number of Fasteners Per Insulation Board: Zone 1': Zone 1• Zone 2- Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, height of Base Flashing, Component Material, Material` Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insuitation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Parapet Weight Mean Roof Height LUCK Section D (Steep Slope Roof System RoofSystern Manufacturer: ___ d AMW J )VIt-D) 1 Notice of Acceptance Number: �.0-ti�Dlo2 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r; Zone 3e: Zone 3r: Deck Type: Type Roof Slope: . 12 h Ridge Ventilation? rl�4 E V,9,J i �I 0 A ,iJo Q'�r�,Ck C- Mean Roof Height: Fire Barrier: 1=astener Type & Spacing: J.'j LA \ Adhesive Type: Type Cap Sheet Rab# Capering: Type & Sim Drip � J7 Edge: Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mr values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RA512T (Zone x 7. = _� - Mg: _ Md Product Approval Mi� (Zone 2e: X _ j - Mg: = M� Product Approval Mr (Zone 2n: x ?t ) -- Mg. Mom, Product Approval Mr (Zone 2r: x al = _) - Mg, = Mom, Product Approval Mf (Zone 3e: - x )L = Mg: = M,99 Product Approval Mf [Zone 3r: Mg; - M� Product Approval M+ ethod 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mrl`'#;rom Tahie Below 13mrinet Annmunt KAa required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25` 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 2.2 33.9 35.1 37.3 5:12 28.4 3 .1 31.6 32.8 34.9 6:12 26.4 28. 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 rv,u�-t ue uaeu in cvnjuncuon wan a usz or moment aasegtite systems • For Uplift based the systems use Method 3. Compare the�alues for F' with the values for Fr If the P values are greater than or equal to the Fr values, for each area of the roof, then the tilottachment method is acceptable. Method 3 "Uplift Based T�=Fri Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W.*cos r Product Approval F' (Zone 2e: x L =x W:=_-__._..._._) -W: cos r �^Fr2e product Approval F' (Zone 2n: x L =x W:=-W: cos r = 2n Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr product Approval F' (Zone 3e: x L =x W:= } -W: cos r --F 3_ Product Approval F' (Zone 3r: x L =x W:=_j -W: cos r =Fr3r Product Approval F' Where to Obtain Information " Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From appJlcable Lble in RA5127 or by an engineering analysis prepared by Pl= ba on A5CE 7 Mean Roof height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier product Approval Restoring Moment due to Gravity M& Product Approval - Attachment Resistance Mr Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions i. = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.