Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOT 17_A200a-LOWER LEVEL #1 NOTED FLOOR PLAN-R4ss
OPEN ABOVE ELEVATOR 1.5" UP 2" POOL EQ 4" CONCRETE PAD WITH 8"X8" THICKEN EDGE W/ (1) #4 CONT. ALL AROUND & (1) LAYER WWM TYPICAL 4'-0"8'-0" POOL EQUIPMENT 101 PAN 'A'PAN 'B'PAN 'P' COLUMN 6" 6" 6" CUCONDENSER 3 CUCONDENSER 4 CUCONDENSER 2 EXPOSED SLAB 103 UPC.H. UNFINISHED 9'-6" 111 GARAGE 1494 SF POOL ABOVE DECK ABOVE DECK ABOVE 104 LANDING C.H. UNFINISHED 9'-6" 112 110 6" 6" 6"4"4"8"WALL ABOVE ROOF ABOVE 20R@7" = 11.5' FLR. - FLR. WALL ABOVE ROOF OPENING ABOVE 22R @ 6.8"=12'-6" FLR-FLR. 6"CUCONDENSER 1 WALL ABOVE 102 6"LEVEL #1 FFE EL. 9.47' NAVD 7.47' NAVD 2" SLOPE 7.30' NAVD GARAGE LEVEL EL. 7.47' NAVD 7.64' NAVD OUTDOOR SHOWER/ DOG WASH SETBACK LINE POURED REINFORCED CONCRETE COLUMN (TYP.) NOTE: MOUNT EQUIPMENT ON THIS LEVEL TO STRUCTURAL COLUMNS, AND NON-FRANGIBLE WALLS (SEE SHEET A200a FOR FRANGIBLE WALL LEGEND). DUE TO THE 24 DEGREE ANGLE TO SHORE, ALL INTERIOR FRAME WALLS THIS LEVEL TO BE FRANGIBLE NOTES: THIS PROJECT IS DESIGNED IN COMPLIANCE WITH FBC 2020 7th EDITION SECTION R322 SEE WALL LEGEND FOR FRANGIBLE WALLS SEE DETAIL 14 ON SHEET A803 FOR INTERIOR FRANGIBLE WALL CONSTRUCTION DETAIL.HBHBHB1 A304 1 A304 2 A304 2 A304 SHEAR WALL (SEE STRUCTURAL) SHEAR WALL (SEE STRUCTURAL) SHEAR WALL (SEE STRUCTURAL) SHEAR WALL (SEE STRUCTURAL) SHEAR WALL (SEE STRUCTURAL) SHEAR WALL (SEE STRUCTURAL) LEVEL #1 POOL AREA TOP OF SLAB EL. 9.14' NAVD 9 FLOOD VENTS EA. VENT 200SF. AS PER MANUF. SPECS., 11 FLOOD VENTS EA. VENT 200SF. AS PER MANUF. SPECS.,AHU 3AHU 2HW AHU 110 FLOOD VENTS EA. VENT 200SF. AS PER MANUF. SPECS., 3 SAND SET PAVERS AT STEPS & LANDING 1 3 3 FLOOD VENT, TYP. FLOOD VENT COUNT SHOWN PER CITY'S REQUEST. 4 A/C AREA TABULATION A/C - 1ST FLOOR A/C - 2ND FLOOR A/C - 3RD FLOOR 420 SF 2479 SF 2316 SF 5214 SF NON A/C AREA TABULATION BEDROOM #2 TERRACE BEDROOM #3 TERRACE COVD. ENTRY COVERED SUNSET TERRACE GARAGE GUEST TERRACE LOUNGE TERRACE OUTDOOR LIVING AREA & DECK & POOL UNFINISHED UNFINISHED UNDER POOL 101 SF 98 SF 67 SF 266 SF 1578 SF 98 SF 192 SF 2219 SF 1426 SF 1781 SF 7825 SF LEVEL #1 WINDOW SCHEDULE Number WIDTH HEIGHT SIZE TYPE HEAD HT. EL.NOTES LEVEL #1 EXT. DOOR SCHEDULE Number WIDTH HEIGHT SIZE TYPE Fire Rating NOTES LEVEL #1 INTERIOR DOOR SCHEDULE Number WIDTH HEIGHT SIZE TYPE FIRE RATING NOTES FLOOD VENT CALCULATIONS GARAGE 1,499 S.F. VENT (as per manuf. specs.)200 S.F. PROVIDED 11 VENTS = 2,200SF UNFINISHED UNDER POOL 1,781 S.F. VENT (as per manuf. specs.)200 S.F. PROVIDED 9 VENTS = 1,800SF 1 2 CMU WALL 8"12" MAX.8X16 FLOOD VENT BY "SMART VENT" MODEL #1540-520 PROPOSED GRADE GARAGE FIN. FLOOR UNFINISHED AREA& LOBBY 1,844 S.F. VENT (as per manuf. specs.)200 S.F. PROVIDED 10 VENTS = 2,000SF 3 3 REQUIRED 8 VENTS = 1,600SF 10-15-21PERMIT SETFLYNN RESIDENCELOT 17- DIAMOND SANDSJENSEN BEACH, FLORIDAALL IDEAS, DESIGNS, ARRANGEMENTS, & PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, & THE PROPERTY OF THIS OFFICE. & WERE CREATED, EVOLVED, & DEVELOPED FOR USE ON, & IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS, OR PLANS SHALL BE USED BY, OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF RANDALL E. STOFFT, ARCHITECTS, P.A. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY & BE RESPONSIBLE FOR ALL DIMENSIONS & CONDITIONS ON THE JOB, & THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED. © 2021. ALL RIGHTS RESERVED RANDALL STOFFT ARCHITECTS P.A. Job No. 2102020 PERMIT SET PA 10-15-21 1 CITY COMMENTS CML 01.03.21 2 CITY COMMENTS CML 02.07.22 3 CITY COMMENTS CML 02.21.22 4 CITY COMMENTS CML 03.14.22 A200a 1/4"=1'-0" LOWER LEVEL NOTED FLOOR PLAN 1 3/4"=1'-0" FLOOD VENT DETAIL2