Loading...
HomeMy WebLinkAboutCertification For Design Load Compliance',MOM MOM` ;-'�'' Planning & Development Services Department Building & Code Regulations Division ~- -- - --- -- — - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: LLeqyo tb�6JL� Project Address: L o� IZ9 9 Lo) Nc.+'(t's 1-s l-' � Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: f New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 6.;11,,3 Code 201N Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I III III IV Exposure Category: B C X D 4. Design Wind Velocity 165 mph ASD >( LRFD End Zone Width: Y• 3 ft � Ir 5. Mean Roof Height � ` i0 ft Roof Pitch: :12 Parapet: &t/ ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: b(7•3 Zone 2: 73•6 Zone 3: 101.6 Zone 4: 50. If Zone 5: Garage: N/A 7. Design Loads: Floor: 65 PSF Roof/Dead: 25 PSF Roof/Live: TO Balcony: yo PSF Dock: nl (A PSF Deck: `/o PSF Stairs: qv PSF Fence: N A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? _Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? ) Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: to,11n PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: - , it 1�'rf Signature,. Date; and Seal SLCCDV Form # 020-12 Revised 3/15/12 (JS) StIAL.n S)ar�yhuS(^ (o(8,50 Print Name Cert # & Co. Cert Auth. A al oc Soo fl­_ of CL.6 Pans, Sk.2La 1Af^ C..IJc.s , icC_ 33118` Company Name & Address