Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 1-27-16i FORM R405-2014 'Planning & Development S FLORIDA ENERGY EFFICIENCY CODE FOR BUILDINGG C,'01qSTRUCTION Florida Department of Business and Professional Regulation - Residentia gRoWfince Method Project Name: Clews Residence Builder Name: Street: Lot 1299 Nettles Island Permit Office: St Lucie County City, State, Zip: Fort Pierce , FL , Permit Number: .Owner: Jurisdiction: 611000 Design Location: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting New (From Plans) 9. Wall Types (1641.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Autoclaved Concrete Block - Int Insul, E)R=4.0 1641.80 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. NIA f 2 4. Number of Bedrooms 3 d. N/A ft2 10. Ceiling Types (1751.0 sgft.) Area 5. Is this a worst case? No a. Roof Deck (Unvented) VR=20.O1.00 ft2 6. Conditioned floor area above grade (ft2) 1751 b. N/A ft2 Conditioned floor area below grade (ft2) 0 c. N/A ft2 11. Ducts R ft2 7. Windows(325.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 350.2 a. U-Factor: Dbl, U=0.24 325.33 ft2 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:17.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 32.0 HSPF:9.60 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1751.0 sgft.) Insulation Area EF: 0.980 a. Raised Floor R=19.0 1751.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.186 Total Proposed Modified Loads: 61.08 PASS Total Baseline Loads: 64.83 I hereby certify that the plans and specifications covered by Review of the plans and ,rtgE ST.gT this calculation are in compliance with the Florida r y specifications covered by this tiW Code. calculation indicates compliance 6u,, with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 '� a * °_ I hereby certify that this bu' ing, as desig ed, is in compliance Florida Statutes. t�, COD with the Florida Energy C y�►� t¢`� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 5/21/2016 4:27 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/l)nsting: Comment: Clews Residence User 1 St Lucie County 611000 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1751 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole, House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address Lot 1299 Nettles Island St. Lucie Fort Pierce , FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1751 15759 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1751 15759 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor Main ---- ---- 1751 ftz 19 0 0 1 ROOF / v # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1897 ftz 0 ftz Medium 0.75 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1751 ft2 N N CEILING - # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 1751 ftz 0.11 Wood 5/21/2016 4:27 PM EnergyGauge® USA - FlaRes20.14 Section R405.4.1 Compliant Software Page 2 of 4 P(1RM PAng,_7(11A WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Omt In Wall TWPSpace R-Vallle Ft In Ft In Area R_-Vaiup Fraction AhSnr Gradp% 1 N Exterior Autoclaved Concrete Block -Main 4 58 8 9 528.0 ft2 0 0.75 0 2 E Exterior Autoclaved Concrete Block -Main 4 30 9 270.0 ft2 0 0.75 0 3 SE Exterior Autoclaved Concrete Block -Main 4 25 9 225.0 ft2 0 0.75 0 4 S Exterior Autoclaved Concrete Block -Main 4 21 9 189.0 ft2 0 0.75 0 5 SW Exterior Autoclaved Concrete Block -Main 4 28 4 9 255.0 ft2 0 0.75 0 6 W Exterior Autoclaved Concrete Block -Main 4 19 5 9 174.8 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width HeightArea Ft In Ft In 1 N Insulated Main None .4 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.24 0.27 62.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 N 1 Vinyl Low-E Double Yes 0.24 0.27 31.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 E 2 Vinyl Low-E Double Yes 0.24 0.27 31.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 SE 3 Vinyl Low-E Double Yes 0.24 0.27 15.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 SE 3 Vinyl Low-E Double Yes 0.24 0.27 12.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 S 4 Vinyl Low-E Double Yes 0.24 0.27 6.9 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 S 4 Vinyl Low-E Double Yes 0.24 0.27 13.2 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 SW 5 Vinyl Low-E Double Yes 0.24 0.27 62.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 SW 5 Vinyl Low-E Double Yes 0.24 0.27 80.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 SW 5 Vinyl Low-E Double Yes 0.24 0.27 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000286 1313.3 72.1 135.59 .2144 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:9.6 32 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 17 36 kBtu/hr 1080 cfm 0.75 1 sys#1 5/21/2016 4:27 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 F()RM PAn.x;_gnlA i HOT WATER SYSTEM T # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.98 40 gal 60 gal .120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 350.2 ft Attic 87.55 ft Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan Heatin[X] Jan [[ ]] Feb [X] Feb Mar Mar Apr [ Apr [ ] May rX] Jun Jul ]May ]Jun IXIJul Au AuSep ri Se rl [ ] [ ]Oct Oct Nov Nov Hx Dec Dec Ventin [[ jj Jan [[ ]] Feb X Mar A r [ ] Ma [[ j Jun Jul L Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/21/2016 4:27 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or epsting 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.24 SHGC: SHGC=0.27 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Raised Floor b. NIA c. NIA Lot 1299 Neftles Island, Fort Pierce, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Autoclaved Concrete Block - Int Insul, E)R=4.0 1641.80 ft2 b. N/A R= ft2 1 c. NIA R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Roof Deck (Unvented) R=20.0 1751.00 ft2 1751 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 325.33 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 350.2 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 36.0 SEER:17.00 ft2 1.000 ft. 0.270 Insulation Area R=19.0 1751.00 ft2 R= ft2 R= ft2 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 32.0 HSPF:9.60 Cap: 40 gallons EF: 0.98 CF, Pstat �oFZK>n srRT�oA� tinlit �n tive *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/21/2016 4:30 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1