Loading...
HomeMy WebLinkAboutHVAC LoadsKlews Residence HVAC Load Calculations for Klews Lot 1299 Nettles Island Fort Pierce, Florida RHVACWAC ADs Prepared By: Residential Energy Calds Sunday, November 22, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ,Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc., Residential Energy Calc's Klews Residence.. Port Saint Lucie, FL 34983 Pa e 2 Project Report IM7 !Pri ecf Information Project Title: Klews Residence Designed By: QEA Associates Project Date: Sunday, November 22, 2015 Client Name: Klews Client Address: Lot 1299 Nettles Island Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's ®esi' n ©ata Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 Check Fi urgesE. Total Building Supply CFM: 1,831 CFM Per Square ft.: 1.045 Square ft. of Room Area: 1,752 Square ft. Per Ton: 363 Volume (ft3) of Cond. Space: 16,236 "Buildin 'Loads • °..MW Total Heating Required Including Ventilation Air: 54,882 Btuh 54.882 MBH Total Sensible Gain: 44,241 Btuh 76 % Total Latent Gain: 13,682 Btuh 24 % Total Cooling Required Including Ventilation Air: 57,922 Btuh 4.83 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software a Development,lnc.' Residential`Energy Calc's Klews Residence Port Saint. Lucie FL 34983 Page,3 Miscellaneous Report Winter: 42 39A 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 Duct Sizin ';Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop, 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.380 AC/hr 0.200 AC/hr 103 CFM 54 CFM Infiltration Actual: 0.369 AC/hr 0.177 AC/hr Above Grade Volume: X 16,236 Cu.ft. X 16,236 Cu.ft. 5,985 Cu.ft./hr 2,880 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 100 CFM 48 CFM Total Building Ventilation: 25 CFM 25 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.380 AC/hr (103 CFM), Construction: Average Summer Infiltration Specified: 0.200 AC/hr (54 CFM), Construction: Average DuctLoad�:Factor-Scenarios forS:• stem.:1. , ;`; � " ' z '' Supply Attic 16B 0.12 6 473 No Return Attic 16B 0.12 6 350 No C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM 1 Load Preview Scope ort Net ft' Sen I LatI Netl Sen Ton /Ton Area Gain Gain Gain Loss 4.83. 363 ' 1,752 , 44,241 13,682 57,922 54,882 688 1,831 1,831 Building - - , - - - - -- _ - - -- 4 83 ' _363 1,752 44,241 1 13,682 ' 57,922, 54,882 688 1,8�1 -1,831 14x21 System 1 ....412, -- -- - - - --.. - - - 412 , 1,038 ' 1,450 ; 769 " Ventilation �--- - -- --- �---------- ---•- --- - - - - -- -------,---- - - 455 4551 Supply Duct Latent 3,591 1 396 _ 4 986 . 1,178 - _- _: ___ -- -- _ - Return Duct - - - - - -- -1,752 40,238 10,793 51,031 y 52,935 688 ® 1,831 14x2 } 1 -- Zone1 -- - --- - - -- ...- - --- - 216 3,548, 1271 4,819 i 5,954, 77, 161 2-5 1-Bedroom 3 ---- - - _ - - - 195 4,366 1253, 5 619 5,851 � 76! 199 2-6 2-Bedroom 2 - - --- _ - - _. - 1-4 ..� _. _. _ 41. 3-Bath 2 72 _ 891 654 , _ 1,545_ ' _ 1 812 4-Laundry - - - - - -- - - - --- ... , - - -- - -35 _ _ 1,039T 645 1,684 880 , 11 26 1-4 - 56 563 663 , 1226 i 1,358 , 18 5 Powder Room - ; _ - ` T232 - 3-5 - ---1,745 _ . 75� - 100 1 6-Master Bath _ -�84 2200 1 745 3 945 2 911 38 - -- 234 5,109 1,118' 6227 5797: 7-Master Bedroom 14611 --499 5-6 3 5 _..,. 8-Living 255 10,9-78 1,354 12332111,230,-. _ - 270 5 553 1,198, 6,7511 7,440 97 9-Ntchen -- 200 3 558 711 4269 5 894 77 2-5 10-Breakfast Room _ .. _. 1 ..._ -- II -Stairway _ __ 95 2,054 145 2,199 2,887 38!� _ 93 1-6 -- 40 378 36 414 r 921 12 17 1-4 12-Hall -- - ._..__.__.._. CA ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac Residential & Light Commercial HVAC Loads EliteSoftwaire Development, Inc. Residential Energy Calc's Klews Resid'erice Port Sarnt Lucie, FL 34983 f Pa a 5' Duct Size Preview Room or Source Minimum Maximum Rough. Design SP Duct Duct Htg Clg Act. Duct Duct Name Velocity Velocity Factor L/100 Loss Velocity Length Flow Flow Flow Size System 1 Supply Runouts- - - Zone 1 1-Bedroom 3 Built -In 4.50 __ 750 _ .. 0.01 ' 01 - 9 77 _ 161 -: 2-5 _.... - _ 2-Bedroom 2 Built -In 450 750 0.01 aY- 01 _591 505 8 76'� 199 2-6 3-Bath 2 Built -In 450. 750 - 0.01 ; 0.1 464.6 - 24 _ 41 i 1-4 4-1-aundry Built -In 450 i 750' 0.01 0.1 : 541.8 11 _ 47 1-4 - 5-Powder Room Built -In 450 750' 0.01. 0.1' 293.7 - 1 8'M 26, 1-4 6-Master Bath Built -In 450 750 0.01 0.1 509.7 38 100. 1-6 7-Master Bedroom Built -In 450 750 0.01 0.1 568.2 751 232 3-5 8-Living Built-in- 450 750 0.01 01 508.7 146 _ 499 : 5-6 9-Kitchen Built -In -- _ 450 - - 750 0.01 01 617.7 97 ®_ 253 3-5 10-Breakfast Room Built -In 4501 7501 0.01 0.1 593.6 ' 77 ® 162_ 2-5 11-Stairway - Built-in - -450 750 - 0.01 - 01 - - 475.9 _ -38'®I 93' 1-6 12-Hall Built In 450 i 750 0.01 01 197 2 ' -- 17 - 1-4 Other Ducts In System 1 Supply Main Trunk Built -In 650 900 0.003 0.1 896.E • 688 1,831 14x21 Summary System 1 Heating Flow:_- 688 - Cooling Flow: 1831 CA ...Wlews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac - Residential & Light Commercial HVAC Loads Residential Energy Calc's Elite Software Development, Inc. Klews Residence ,Port Saint Lucie, FL 34983 Pa e 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan L_ oss Gain Gain Gain 7A-1: Glazing -Glass or plastic block, smooth or wide ribs 8.2 139 0 367 367 or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 3: Glazing- 15 454 0 480 480 IA-cb-o: Glazing -Single pane, operable window, clear, 216.9 6,559 0 12,748 12,748 metal frame with break, u-value 1.08, SHGC 0.75 1A-cm-o: Glazing -Single pane, operable window, clear, 80 2,844 0 2,788 2,788 metal frame no break, u-value 1.27, SHGC 0.75 13A-4fcs: Wall -Block, board insulation only, R-4 board 1662.8 5,445 0 2,975 2,975 insulation, filled core, siding finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1752 1,570 0 2,244 2,244 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 20P-0t: Floor -Over open crawl space or garage, Passive, 1752 25,560 0 9,128 9,128 _ no insulation, the or v_ inyl ___ Subtotals for structure: 42,571 0 30,730 30,730 People: 11 2,200 2,530 4,730 Equipment: 6,600 1,800 8,400 Lighting: 0 0 0 Ductwork: 8,471 1,851 7,978 9,829 Infiltration: Winter CFM: 100, Summer CFM: 48 3,071 . 1,993 791 2,784 Ventilation: Winter CFM: 25, Summer CFM: 25 769 1,038 _ 412 1,450 Total Building Load Totals: 54,882 13,682 44,241 ' 57,922 .Check Fiures 9.. 5� Total Building Supply CFM: 1,831 CFM Per Square ft.: 1.045 Square ft. of Room Area: 1,752 Square ft. Per Ton: 363 Volume (ft3) of Cond. Space: 16,236 Bwldin Total Heating Required Including Ventilation Air: 54,882 Btuh 54.882 MBH Total Sensible Gain: 44,241 Btuh 76 % Total Latent Gain: 13,682 Btuh 24 % Total Cooling Required Including Ventilation Air: 57,922 Btuh 4.83 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Q\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac -Residential ALight Commercial HVAC Loads-' Residential Energy Calc's Elite'Software Development, Inca Mews Residence .Poit Saint Lucie, FL 34983 Page 8 Detailed Room Loads - Room 1 -.Bedroom 3 (Average Load Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 216.0 sq.ft. Supply Air: 161 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 5.0 AC/hr Volume: 1,944.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 81 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 592 ft./min. Percent of Supply: 1 % Runout Air Velocity: 592 ft./min. Actual Winter Infil.: 14 CFM Actual Loss: 0.288 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item Area -U- Htg Sen Clg Lat Sen Descn tion Quanti slue _ _ HTM Loss HTM Gain Gain .. E -Wall-13A-4fcs 18 X 9 156 0.117 3.3 511 1.8 0 279 S -Wall-13A-4fcs 12 X 9 93 0.117 3.3 305. 1.8 0 166 E -GIs-7A-1 shgc-0.65 55%S 6 0.600 16.8 101 44.5 0 267 S -GIs-3 shgc-0.75 100%S 15 1.080 30.2 454 32.0 0 480 UP-Ceil-16C-30 18 X 12 216 0.032 0.9 194 1.3 0 276 Floor-20P-Ot 12 X 18 216 0.521 14.6 3,151 5.2 0 1,125 Subtotals for Structure: 4,716 0 2,593 Infil.: Win.: 13.6, Sum.: 6.5 270 1.548 418 0.400 271 108 Ductwork: 820 387 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: _ _ _ _ 600 0 Room Totals: 5,954 1,271 3,548 C:1... \Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM ,,Rhvac - Residential & Light Commercial HVAC Loads Elite Soelopment, Inc. ftware Dev. Residential Energy Calds Klews Residence Port Saint Lucie, FL 34983 Pa e 9 Detailed Room Loads - Room 2 - Bedroom 2 (Average Load Procedure) OTAMS 906 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 195.0 sq.ft. Supply Air: 199 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 6.8 AC/hr Volume: 1,755.0 cu.ft. Req. Vent. Clg: ' 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 99 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 506 ft./min. Percent of Supply: 1 % Runout Air Velocity: 506 ft./min. Actual Winter Infil.: 13 CFM Actual Loss: 0.164 in.wg./100 ft. Actual Summer Infil.: 6 CFM Ifern Area -WH nM Gain G_ ain S -Wall-13A-4fcs 13 X 9 102 0.117 3.3 334 1.8 0 183 W -Wall-13A4fcs 15 X 9 120 0.117 3.3 393 1.8 0 215 S -GIs-1A-cb-o shgc-0.75 100%S 15 1.080 30.2 454 32.0 0 480 W -GIs-IA-cb-o shgc-0.75 16%S 15 1.080 30.2 454 79.0 0 1,185 UP-Ceil-16C-30 15 X 13 195 0.032 0.9 175 1.3 0 250 Floor-20P-Ot 13 X 15 19_5_ 0.521 14.6 2,845 5.2 _ 0 1,016 Subtotals for Structure: 4,655 0 3,329 Infil.: Win.: 12.7, Sum.: 6.1 252 1.548 390 0.401 253 101 Ductwork: 806 476 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: _ _ _ 600 0 Room Totals: 5,851 1,253 4,366 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM 'Rhvac - Residential & Light Commercial HVAC Loads Residential Energy Calc's ' Elite Software' Development, Inc. Klews Residence Port Saint Lucie, FL U983 Page 10 Detailed Room Loads - Room 3 - Bath 2 (Average Load Procedure General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 72.0 sq.ft. Supply Air: 41 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 3.8 AC/hr Volume: 648.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 41 CFM Percent of Supply.: 2 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 465 ft./min. Percent of Supply: 1 % Runout Air Velocity: 465 ft./min. Actual Winter Infl.: 3 CFM Actual Loss: 0.245 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- Htg Sen C•Ig Lat Sen Description Quanf Value HTM Loss HTM Gain Gain N -Wall-13A-4fcs 6 X 9 47.1 0.117 3.3 154 1.8 0 84 N -GIs-1A-cb-o shgc-0.75 100%S 6.9 1.080 30.2 209 32.0 0 221 UP-Ceil-16C-30 12 X 6 72 0.032 0.9 65 1.3 0 92 Floor-20P-Ot 6 X 12 72 0.521 14.6 1,050 5.2 0 375 Subtotals for Structure: 1,478 0 772 Infil.: Win.: 2.7, Sum.: 1.3 54 1.556 84 0.407 54 22 Ductwork: 250 97 Equipment: 600 0 Room Totals: 1,812 654 891 Q\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM hvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Residential; Energy Calc's Klews Residence Port Saint'Lucie, FL 34983 Pa a 11 Detailed Room Loads - Room 4 - Laund (Average Load Procedure) .General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 7.0 ft. System Number: 1 Room Width: 5.0 ft. Zone Number: 1 Area: 35.0 sq.ft. Supply Air: 47 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 9.0 AC/hr Volume: 315.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 47 CFM Percent of Supply.: 1 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 542 ft./min. Percent of Supply: 1 % Runout Air Velocity: 542 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.331 in.wg./l00 ft: Actual Summer Infil.: 1 CFM Item Area -U- Htg Sen C*Ig Lat Sen ®escri tion Quanti Value HTM Loss HTM Gain Gain W-Wall-13A-4fcs 5 X 9 45 0.117 3.3 147 1.8 0 81 UP-Ceil-16C-30 7 X 5 35 0.032 0.9 31 1.3 0 45 Floor-20P-Ot 5 X 7 35 0.521 14.6 511 5.2 0 182 Subtotals for Structure: 689 0 308 Infil.: Win.: 2.3, Sum.: 1.1 45 1.556 70 0.400 45 18 Ductwork: 121 113 Equipment: 600 600 Room Totals: 880 645 1,039 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac Residential Light Commercial HVAC Loads Elite Software:Development; lnc:'' Residehtial'Ener6 cales Klews Residence; Poit Saint Lucie FL-34983 Pa a 12,, Detailed Room Loads°- Room 5 - Powder Room (Average Load Procedure) General . _.. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 56.0 sq.ft. Supply Air: 26 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 3.1 AC/hr Volume: 504.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 26 CFM Percent of Supply.: 3 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 294 ft./min. Percent of Supply: 1 % Runout Air Velocity: 294 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.099 in.wg./100 ft. Actual Summer Infil.: 2 CFM UP-Ceil-16C-30 8 X 7 Floor-20P-Ot 7 X 8 56 0.032 0.9 50 1.3 56 0.521 14.6 817 5.2 U 0 fZ 292 Subtotals for Structure: 1,073 0 477 Infil.: Win.: 3.2, Sum.: 1.5 63 1.556 98 0.397 63 25 Ductwork: 187 61 Equipment: 600 0 Room Totals: 1,358 663 563 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac Residential & Light Commercial HVAC Loads 9 Elite Software Dev elopmisid Inc.. Residential Ene rgy Calc's, .. KI ews,Residence. Foit Saint Lucie, FL 34983 _ ', Pa a 13 Detailed Room Loads - Room 6 - Master Bath (Average Load Procedure) .General .' plig! ago IN Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 84.0 sq.ft. Supply Air: 100 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 7.9 AC/hr Volume: 756.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 100 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 510 ft./min. Percent of Supply: 1 % Runout Air Velocity: 510 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.166 in.wg./100 ft. Actual Summer Infil.: 3 CFM 1fem�. Iwwriltion, Area -U- I�tg Sen Clg Laf Sen rv. , Quanti Value , HTM Loss HTM Gain Gain E -Wall-13A- 4fcs 12 X 9 105.8 0.117 3.3 346 1.8 0 189 N -Wall-13A-4fcs 4 X 9 18 0.117 3.3 59 1.8 0 32 E -GIs-7A-1 shgc-0.65 55%S 2.2 0.600 16.8 38 44.4 0 100 N -GIs-IA-cb-o shgc-0.75 100%S 18 1.080 30.2 544 32.0 0 576 UP-Ceil-16C-30 12 X 7 84 0.032 0.9 75 1.3 0 108 Floor-20P-Ot 7 X 12 84 0.521 14.6 1,225 5.2 0 438 Subtotals for Structure: _ 2,287 0 1,443 Infil.: Win.: 7.2, Sum.: 3.5 144 1.549 223 0.396 145 57 Ductwork: 401 240 People: 200 lat/per, 230 sen/per: 2 400 460 Eguipment__ _ _ _ V _1,200 0 Room Totals: 2,911 1,745 2,200 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM hvac Residential Light Commercial HVAC Loads Elite:°Softwa'e Developrrient, Inc Residential Energy`Calc's Klevi+s Residence Port Saint Lucie, FL 34983 Pa a 14 Detailed Room Loads - Room 7 - Master Bedroom (Average Load Procedure =4General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 234.0 sq.ft. Supply Air: 232 CFM Ceiling Height: 11.0 ft. Supply Air Changes: 5.4 AC/hr Volume: 2,674.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 3 CFM Runout Air: 77 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 568 ft./min. Percent of Supply: 1 % Runout Air Velocity: 568 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.266 in.wg./100 ft. Actual Summer Infil.: 3 CFM m Area�W_UF�sq�ioen I11offn Quantiae HTM Loss HTM Gain Gain E -Wall-13A-4fcs 13 X 9 87 0.117 3.3 285 1.8 0 156 E -GIs-IA-cb-o shgc-0.75 16%S (2) 30 1.080 30.2 908 79.0 0 2,370 UP-Ceil-16C-30 18 X 13 234 0.032 0.9 210 1.3 0 300 Floor-20P-Ot 13 X 18 234 0.521 14.6 3,414 5.2 0 1,219 Subtotals for Structure: 4,817 0 4,045 Infil.: Win.: 5.9, Sum.: 2.8 117 1.547 181 0.402 118 47 Ductwork: 799 557 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 0 Room Totals: 5,797 1,118 5,109 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM Rhvac - Residential & Light Commercial HVAC Loads,, Residential, Energy CaVsi Elite Software Development, Inc. Klews Residence Port Saint Lucie, FL 34983 Pa` a 15 Detailed Room Loads - Room 8 - Living (Average Load Procedure) GeneralNow Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 255.0 sq.ft. Supply Air: 499 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 13.1 AC/hr Volume: 2,295.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 5 CFM Runout Air: 100 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 509 ft./min. Percent of Supply: 1 % Runout Air Velocity: 509 ft./min. Actual Winter Infil.: 18 CFM Actual Loss: 0.166 in.wg./100 ft. Actual Summer Infil.: 9 CFM Item b Area -U-1113OR Sen Clg Lat Sen QeSc,t_on , . ,:., z Quanti Value HTM Loss HTM Gain Gain E -Wall-13A-4fcs 17 X 11 133 0.117 3.3 436 1.8 0 238 N -Wall-13A-4fcs 15 X 11 85 0.117 3.3 278 1.8 0 152 E -GIs-1A-cb-o shgc-0.75 13%S (2) 54 1.080 30.2 1,632 80.5 0 4,348 N -GIs-IA-cm-o shgc-0.75 100%S 80 1.270 35.6 2,844 34.9 0 2,788 (2) UP-Ceil-16C-30 17 X 15 255 0.032 0.9 228 1.3 0 326 Floor-20P-Ot 15 X 17 255 0.521 14.6 3,720 5.2 0 1,329 Subtotals for Structure: 9,138 0 9,181 Infil.: Win.: 17.7, Sum.: 8.5 352 1.548 545 0.398 354 140 Ductwork: 1,547 1,197 People: 200 [atiper, 230 sen/per: 2 400 460 Equipment: 600 0 Room Totals: 11,230 1,354 10,978 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 1:53 PM hvac - Residential& Light. Commercial HVAC Loads Rosidential-Energy Calc's Elite Software Development, Inc.' Klews'Residence Port Saint Lucie, FL 34983 Pa a 16 Detailed Room Loads - Room 9 - Kitchen (Average Load Procedure) LGeneral,; Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 270.0 sq.ft. Supply Air: 253 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 6.2 AC/hr Volume: 2,430.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 4 CFM Runout Air: 84 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 618 ft./min. Percent of Supply: 1 % Runout Air Velocity: 618 ft./min. Actual Winter Infil.: 20 CFM Actual Loss: 0.313 in.wg./l00 ft. Actual Summer Infil.: 10 CFM Item �'�' 'MIM-U- Area I•itg Sen Clg Lat Sen 4De'scri;tion Quantit Value HTM Loss 9TK411MWGain_ Gain. W -Wall-13A-4fcs 15 X 11 153 0.117 3.3 501 1.8 0 274 N -Wall-13A-4fcs 18 X 11 198 0.117 3.3 649 1.8 0 354 S -Wall-13A-4fcs 3 X 11 33 0.117 3.3 108 1.8 0 59 W -GIs-IA-cb-o shgc-0.75 20%S 12 1.080 30.2 363 76.7 0 920 UP-Ceil-16C-30 18 X 15 270 0.032 0.9 242 1.3 0 346 Floor-20P-Ot 15 X 18 270 0.521 14.6 3,939 5.2 0 1,407 Subtotals for Structure: 5,802 0 3,360 Infil.: Win.: 19.9, Sum.: 9.6 396 1.548 613 0.399 398 158 Ductwork: 1,025 605 People: 200 lat/per, 230 sen/per: 1 200 230 600 - - 1,200 Room Totals: 7,440 1,198 5,553 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM • �Residenfial hdac.= Iesidential & Light Commercial HVAC Loads Elite Software Development, li Energy Calc sKlews'Resider ort Saint Lucie FL 34983 Page, Detailed Room Loads -Room 10 -Breakfast Room (Average Loaa rroceaure� � ^General -- 1 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number: Room Idth: 10.0 ft. Zone Number: 1 Area: 200.0 sq.ft. Supply Air: 162 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 5.4 AC/hr Volume: 1,800.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 81 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 594 ft./min. Percent of Supply: 1 % Runout Air Velocity: 594 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.290 in.wg./100 ft. Actual Summer Infil.: 3 CFM N -wau-1 sH-4res -1 u n I I N -GIs-IA-cb-o shgc-0.75 100%S Ipw 54 �. , 1. — 1.080 30.2 � - - 1,632 32.0 0 1,728 (2) UP-Ceil-16C-30 20 X 10 200 0.032 0.9 179 1.3 0 256 Floor-20P-Ot 10 X 20 200 0.521_ _ _14.6 __. 2,91.8 _ 5.2 _ 0 1,042 Subtotals for Structure: 110 1.545 4,912 170 0.400 0 111 3,126 44 Infil.: Win.: 5.5, Sum.: 2.7 812 388 Ductwork: 600 0 Equipment: Room Totals: 5,894 711 3,558 ':\ ...Mews Residence.rh9 Sunday, November 22, 2015, 12:51 PM •Rhvac'- residential & Light Commercial HVAC Loads Elite software'Development, Inc. Residential EnergyCaics, ".' Mews Residence" Pa a 18'. Port Saint Lucie, FL 34983 Detailed Room Loads -Room 1 I --Stairway (Avera a Load Procedure) General r> a ,. Calculation Mode: Ht77MTrMwwM= Room Length: 1 Room Width: .. u 1 Area: 95.0 sq.ft. Supply Air: 93 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 6.6 AC/hr Volume: 855.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 93 CFM Percent of Supply.: 1 % Runout Duct Size: 6 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 476 ft./min. Percent of Supply: 1 % Runout Air Velocity: 476 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.145 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Clg Lat SeQHTM mwimHtgM"M HTM GaiGain 3.3 1.8 0 172 S -Wall-13A-4fcs 4 X 9 36 0.117 3.3 118 1.8 0 64 W -GIs-1A-cb-o shgc-0.75 20%S 12 1.080 30.2 363 76.7 0 920 UP-Ceil-16C-30 19 X 5 95 0.032 0.9 85 1.3 0 122 Floor-20P-Ot 5 X 19 95 0.521 14.6 _ 1,386 5.22 _ 0 495 Subtotals for Structure: 2,266 0 1,773 Infil.: Win.: 7.2, Sum.: 3.5 144 1.549 223 0.396 145 57 Ductwork: 398 224 Room Totals: 2,887 145 2,054 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM hvac - Residential & Light Commercial HVAC Loads , Residential Energy Calds Elite;Software Development, Inc., Klews Residence Port"Sainttucie, FL. 34983 Page 19 Detailed Room Loads - Room 12 - Hall (Average Load Procedure) General ' Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 40.0 sq.ft. Supply Air: 17 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.9 AC/hr Volume: 360.0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 17 CFM Percent of Supply.: 3 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 197 ft./min. Percent of Supply: 1 % Runout Air Velocity: 197 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.046 in.wg./100 ft. Actual Summer Infil.: 1 CFM Item Area -U- Htg Sen Clg Lat0 0 Sen Descr_i Lion Quanti Value HTM Loss HTM Gain Gain N -Wall-13A-4fcs 4 X 9 36 0.117 3.3 118 1.8 0 64 UP-Ceil-16C-30 10 X 4 40 0.032 0.9 36 1.3 0 51 Floor-20P-Ot 4 X 10 40 0.521 14.6 584 5.2 0 208 Subtotals for Structure: 738 0 323 Infil.: Win.: 1.8, Sum.: 0.9 36 1.556 56 0.389 36 14 Ductwork: 127 41 Room Totals: _ 921 36 378 C:\ ...\Klews Residence.rh9 Sunday, November 22, 2015, 12:51 PM ttvac Residential &Light Commercial HVAC Loads Elite Software Development, lnc. _ Resid4htial Energy Klews Residence' Port Saint Lucie, FL. 34983 - Pa a 20 System I., Room Load S007mary ri.. Roomry Area Sens: HtDuct 'Sense Lat g Sys ,D`uct ,: , C r FM --Zone 1-- 1 Bedroom 3 216 5,954 77 2-5 592 3,548 1,271 161 161 2 Bedroom 2 195 5,851 76 2-6 506 4,366 1,253 199 199 3 Bath 2 72 1,812 24 1-4 465 891 654 41 41 4 Laundry 35 880 11 1-4 542 1,039 645 47 47 5 Powder Room 56 1,358 18 1-4 294 563 663 26 26 6 Master Bath 84 2,911 38 . 1-6 510 2,200 1,745 100 100 7 Master Bedroom 234 5,797 75 3-5 568 5,109 1,118 232 232 8 Living 255 11,230 146 5-6 509 10,978 1,354 499 499 9 Kitchen 270 7,440 97 3-5 618 5,554 1,198 253 253 10 Breakfast Room 200 5,894 77 2-5 594 3,558 411 162 162 11 Stairway 95 2,887 38 1-6 476 2,054 145 93 93 12 Hall 40 921 12 1-4 197 378 36 17 17 Ventilation 769 412 1,038 Duct Latent 456 Return Duct 1,178 3,591 1,396 System 1 total _ 1,752 54,882 688 _ _ 44,242 13,382 1,8311,831 System 1 Main Trunk Size: 14x21 in. Velocity: 897 ft./min Loss per 100 ft.: 0.092 in.wg Coolin' S stem:Sumrna ` Coolmg' Sensible en1 Latent`;Ssib, Latent= Tota( r��Brtuh� lit ; . '..; ', rx �;� _Btuh ? mare, ,� sBtuh,' Net Required: 4.80 77% / 23% 44,242 13,382 57,624 Actual: 4.83 77% / 23% 44,500 13,500 58,000 Equipment Data Heating System Coolinq System Type: Two Speed Heat Pump Standard Air Conditioner Model: RXBH 24A10J RPRL060JEC Indoor Model: RHPLHM6024JC Brand: PRESTIGE SERIES PRESTIGE SERIES Description: HEAT PUMP HSPF 9.5 SPLIT SYSTEM 16 SEER Efficiency: Hi: 9.6 / Lo: 0 HSPF 16 SEER Sound: 0 0 Capacity: 58,000 Btuh 58,000 Btuh Sensible Capacity: n/a 44,500 Btuh Latent Capacity: n/a 13,500 Btuh C:\ ...1Klews Residence.rh9 Sunday, November 22, 2015, 2:28 PM