HomeMy WebLinkAboutInsulation - Installation CertificateAug 26 16 07:20a JWN ConstrLI `:-;n 77?�7871-9500 p.2 INSULATION INSTALLATION CERTIFICATE TO: JWN Construction LOT BLOCK: SECTION: JOB#: 108148 JOB NAME: Clews Res JOB ADDRESS: 1299 Nettles Blvd The undersigned hereby cerdfec that insulation has been installed at the above described propem- as follows: 1. Exterior C13S walls have been insulated with .......... ..................Check one ( ) Spray on cellulose to a thickness of NIA inches, which thickness, according to the ( ) Fiberglass blankets manufacturer, CFI ( )Aluminum Foil Density NIA will yield an "R" value of 9 Q9 Block Fill Exterior Frame walls have been insulated with ............................Check one ( ) Spray on cellulose to a thickness of inches, which Thickness, according to the ( ) Fiberglass blankets manufacture'•, ' ( ) Aluminum Foil Density TWA will yield an "R" value of ( ) Other Spray Foam 2. Main Ceilings have been insulated with ...................... --Check one ( ) Fiberglass blankets to a thickness of 5.25 inches, which thickness, according to the ( ) Fiberglass loose fill manufacturer, SES Sucraseal () Aluminum Foil Density NIA will yield an "R" value of 20 00 Spray Foam Ceilings Cathedral have been insulated with .........................Check one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Fiberglass loose fill manufacturer, () Aluminum Foil Density NIA will yield an "R" value of () Other Cellulose 3. Interior knee walls have been insulated with_...............................Check one () Fiberglass blankets to a thickness of inches, which thickness, according to the () Polyurethane manufacturer, () Spray on cellulose Density t41A will yield an "R" value of ( ) Other Spray Foam 4. Garage partition walls of conditioned living areas have been insulated with ...................... ................................................... .,..,.Chcck one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Spray on cellulose manufacturer, ( ) Polyurethane Density NIA will yield an "R" value of ( ) Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common [party) walls separating different tenants shall be insulated as follows - Frame(Metal stud walls R-1 I (Min.); CBS or Concrete walls R-3 (Min.); by Energy Code requirements. See Energy Code Rev. U87, paragraph 903.2(b), on page 9-17, latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall be installed in the field. NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F. (lb/83) average of three (3) "DRY SAMPLES" of acntal installano T t MER Enterprises LLC Insulation Contractor Insulation Contractor Signature MCI N6231 Insulation Contractors CC# 7116/16 Date of Certification Builder's Name - guilder's CC# i'h�' Ptlbl c �r " KELLY L YOUNG •' Al Notary Public State of Florida =s ;l, a My Comm. Expires Jul 1, 2018 +-`''' Corttmisston FF 138101 Aug 2616 07:20a JWN ConstrU^+�^7 7??-871-9500 p.1 1701 SE Carvalho Street Pori St. Lucie. FL 34983 772-871-9500 772-871-9500 Jwnbuilders.com Fax To: Eileen From: James Fax: 462-1578 Pages: 2 Phone: Date: August 26, 2016 Re: cc: 0 Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle Comments: