HomeMy WebLinkAboutInsulation - Installation CertificateAug 26 16 07:20a JWN ConstrLI `:-;n 77?�7871-9500 p.2
INSULATION INSTALLATION CERTIFICATE
TO: JWN Construction LOT BLOCK: SECTION:
JOB#:
108148 JOB NAME: Clews Res
JOB ADDRESS: 1299 Nettles Blvd
The undersigned hereby cerdfec that insulation has been installed at the above described propem- as
follows:
1. Exterior C13S walls have been insulated with .......... ..................Check one
( ) Spray on cellulose
to a thickness of NIA
inches, which thickness, according to the
( ) Fiberglass blankets
manufacturer,
CFI
( )Aluminum Foil
Density NIA
will yield an "R" value of 9
Q9 Block Fill
Exterior Frame walls have been insulated with ............................Check one
( ) Spray on cellulose
to a thickness of
inches, which Thickness, according to the
( ) Fiberglass blankets
manufacture'•, '
( ) Aluminum Foil
Density TWA
will yield an "R" value of
( ) Other Spray Foam
2. Main Ceilings have
been insulated with ...................... --Check one
( ) Fiberglass blankets
to a thickness of 5.25
inches, which thickness, according to the
( ) Fiberglass loose fill
manufacturer,
SES Sucraseal
() Aluminum Foil
Density NIA
will yield an "R" value of 20
00 Spray Foam
Ceilings Cathedral
have been insulated with .........................Check one
( ) Fiberglass blankets
to a thickness of
inches, which thickness, according to the
( ) Fiberglass loose fill
manufacturer,
() Aluminum Foil
Density NIA
will yield an "R" value of
() Other Cellulose
3. Interior knee walls have
been insulated with_...............................Check one
() Fiberglass blankets
to a thickness of
inches, which thickness, according to the
() Polyurethane
manufacturer,
() Spray on cellulose
Density t41A
will yield an "R" value of
( ) Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated with ...................... ................................................... .,..,.Chcck one
( ) Fiberglass blankets
to a thickness of
inches, which thickness, according to the
( ) Spray on cellulose
manufacturer,
( ) Polyurethane
Density NIA
will yield an "R" value of
( ) Other Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common [party) walls separating
different tenants shall be insulated as follows - Frame(Metal stud walls R-1 I (Min.); CBS or Concrete walls
R-3 (Min.); by Energy Code requirements. See Energy Code Rev. U87, paragraph 903.2(b), on page 9-17,
latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F.
(lb/83) average of three (3) "DRY SAMPLES" of acntal installano
T t
MER Enterprises LLC
Insulation Contractor Insulation Contractor Signature
MCI N6231
Insulation Contractors CC#
7116/16
Date of Certification
Builder's Name - guilder's CC# i'h�' Ptlbl c �r
" KELLY L YOUNG
•' Al Notary Public State of Florida
=s ;l, a My Comm. Expires Jul 1, 2018
+-`''' Corttmisston FF 138101
Aug 2616 07:20a JWN ConstrU^+�^7 7??-871-9500 p.1
1701 SE Carvalho Street
Pori St. Lucie. FL 34983
772-871-9500
772-871-9500
Jwnbuilders.com
Fax
To: Eileen
From: James
Fax: 462-1578 Pages: 2
Phone: Date: August 26, 2016
Re: cc:
0 Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle
Comments: