HomeMy WebLinkAbout25 Reinforcing Steel - North Bldg (3-11-22)out N"
GFA PROJECT#
PROJECT
LOCATION
PERMIT NO.
OWNER
�r. I A Universal
VOrr aL LOCIe, r/or/Oa 14voo
wy,
21-9325.00
Cristelle Cay Condos
4804 N. At Fort Pierce FL
1908-2014 North
Cardinal Ocean Development. LLC
CONTRACTOR Cardinal Ocean Development. LLC
ARCHITECT Frank C. Snedaker
ENGINEER Stirling & Wilbur Engineering
cngrneenny Prone: 77Z 924-3575 Fax: 7729Z4-35E0
Sciences
Company REINFORCING STEEL
INSPECTION REPORT
DATE Friday, March 11, 2022
WEATHER
TEMPERATURE
WIND
HUMIDITY
S M T W TH F S
DAY x
BRIGHT SUN
CLEAR
OVERCAST
RAIN
x
BELOW 60
60-75
75-90
ABOVE 90
x
LOW
MODERATE
HIGH
Report No
x
25
LOW
MODERATE
HIGH
x
MEMBERS/AREA INSPECTED: Reinforcing Steel: North Bldg. for Rebars Placement on the 3rd floor and layout
for Columns and Shear Walls.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO NIA
1 SOIL BEARING CAPACITY
2 BUILDING LOCATION
3 BUILDING SLAB ELEVATION
4 TERMITE TREATMENT VERIFIED
5 COMPACTION TESTING
6 FORMING DIMENSIONS
7 INSIDE OF FORMS CLEAN
8 WIRE MESH REINFORCING SIZE AND LAP
9 REBAR GRADE, SIZE, SPACING, QUANTITY, SHAPE, TYING
10 SPLICES
11 REBAR CLEAN AND FREE OF OIL
12 REBAR CLEARANCE FROM FORMS AND EARTH
13 EMBEDS/ANCHOR BOLTS IN PLACE AND SECURED
14 SHORING AND RE -SHORING
15 POST TENSIONED CABLE LAYOUT AND PROFILE
Disposition of Inspection
Px
x Section / Area Approved Re -Inspection
Work In Progress RRe-Inspection Required
COMMENTS/ACTION REQUIRED: Partial inspection.
Inspection Performed By/
Inspection Certified B
Registered Professional N4:.
Certified Special Inspector No:
FBPE Certificate No: 4930
4046
Environmental . Grnt. nical . Constmdion Matenals Testing. Special & Threshold Inspections. Plan Review & Code Compliance
Florida's Leading Engineering Source
wwwAserngfiecon,