Company CONCRETE PLACEMENT
INSPECTION REPORT
GFA PROJECT# 3310.210035
DATE Monday, March 7, 2022
PROJECT Cristelle Cay Condos
S M T W TH F S
LOCATION 4804 N. Al Fort Pierce, FL. 34949 DAY x
PERMIT NO. South Building - 1908-0215
OWNER Cardinal Ocean Development, LLC
CONTRACTOR Cardinal Ocean Develepment, LLC
ARCHITECT Frank C Snedaker
ENGINEER Stirling & Wilbur Engineering
MEMBERS/AREA INSPECTED: 3rd Floor Slab for the entire bl
WEATHER
TEMPERATURE
WIND
HUMIDITY
BRIGHT SUN
CLEAR
OVERCAST
RAIN
x
x
BELOW 60
60-75
75-90
ABOVE 90
x
LOW
MODERATE
HIGH
Report No
x
LOW
MODERATE
HIGH
16
x
+ North and South stairs.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
x
1 SPARE VIBRATOR ON HAND
x
2 FORMS WETTED/OILED
x
3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
x
4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
x
5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAYS POUR
x
6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
x
7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
x
8 SUFFICIENT VIBRATION PERFORMED
x
9 STEEL REMAINED IN PLACE DURING POUR
x
10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
AREA
POURED
YDS
PSI
TYPE MIX
SLUMP
IN t IN
START TIME
END TIME
METHOD OF
PLACEMENT
SUPPLIER
x
205
5,000
50000401
5
5:30 AM
1:00 PM
pump
Maschme er
Disposition of Inspection
BSection / Area Observed
Work In Progress
COMMENTS/ACTION REQUIRED:
BRe -Inspection
Re -Inspection Required
Inspection Performed By: Fady Bo A [CC
Inspection Certified By:
Registered Professional No: P.E. 44653
Certified Special Inspector No: SI 1103
FBPE Certificate No: 4930