Loading...
HomeMy WebLinkAboutNotice Of Product CertificationNOTICE OF PRODUCT CERTIFICATION RECEIVED Company: Masonite International Corporation Certification No.: NI007077.09-R4 1955 Powis Road MAR 0 4 2022 Certification Date: 05/22/20017 West Chicago, IL 60185 Expiration Date: 12/31/2025 St. Lucie County Revision Date: Permitting 07/27/2020 Product: Fiberglass Impact Rated Glazed Inswing or Outswing Door w/ and w/o Impact Rated Sidelites (w/Wood Frame or Worldwide Composite Frame' unless noted) Specification: TAS 201/202/203-94/ASTM E330-02 The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listin at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute ANS . Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X US Glazed 3'0" x 6'8" +55/-55 0 psf Yes NCTL-210-3389-1/AT1,NC 1203.01-14/ATLNC 1012.01-16 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1885 X O/S Glazed 3'0" x 6'8" +551-55 3.75 psf/ 6.0 psf 1 Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Single 8.25 psf 2/9.0 psf 4 Maximum Panel Size: 3'0" x 6'8" 7.5 psf 5 Anchor Details-MA-FL0172-07/W-1807/W-1835/W- 1860/W-1885 XX US Glazed 6'0" x 6'8" +50/-55 0 psf Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1885 XX O/S Glazed 6'0" x 6'8" +551-55 3.75 psf/ 6.0 psf 1 Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Double 8.25 psf Z/8.25 psf 4 Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FLA172-07/W-1807/W-1835/W-1885 XO/OX US Glazed Door 6'0" x 6'8" +55/-55 0 psf Door -Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Single w/Sidelite Glazed Sidelite Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1885 XO/OX O/S Glazed Door 6'0" x 6'8" +551-55 3.75 psf/ 6.0 psf Door-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Single w/Sidelite Glazed Sidelite 8.25 psf 2/9.0 psf' Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 OXO US Glazed Door 910" x 6'8" +551-55 0 psf Door -Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Single w/Sidelites Glazed Sidelites Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1885 OXO O/S Glazed Door 910" x 6'8" +551-55 3.75 psf/ 6.0 psf 1 Door -Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Single w/Sidelites Glazed Sidelites 8.25 psf z/9.0 psf 4 Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 OXXO US Glazed Doors 12'6" x 6'8" +501-55 0 psf Door -Yes NCTL,-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Double w/Sidelites Glazed Sidelites Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1885 OXXO O/S Glazed Doors 12'6" x 6'8" +551-55 3.75 psf/ 6.0 psf 1 Door -Yes NCTL -210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Double w/Sidelites Glazed Sidelites 8.25 psf z/8.25 psf' Sidelite-Yes Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 1-Denotes Z-Series Threshold Design 2 -Denotes High Dam Threshold Design 3-W-1815 4-Denotes Worldwide Pro T4 Threshold 5-Denotes HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 REVIEWED FOR CODE COMPLIANCE FI COPY ��-3l�l�ZL ST. LUCIE COUNTY BOCC Z NArM AUTHORIZED SIGNATURE: MASONITE. STORMGUARD FIBERGLASS DOOR UNIT V-8" DOUBLE DOOR WITH / WITHOUT SIDELITES GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. THIS PRODUCT DOES N07 REQUIRE THE USE OF A HURRICANE PROTECTIVE SYSTEM (SHUTTERS). 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 4. PLASTICS TESTING: TMT nRQPRIOTinkl nMIQLI�TIn.1 SELF IGNITION TEMP ASTM D1929 752 'F >...650 'F 842 'F > 650 'F RATE OF BURNING ASTM D635....., " 0.56 IN .:MIN 1.28 IN MIN SMOKE DENSITY ASTM D2843 : 53.4% - 70.2% TENSILE STRENGTH" ASTM D638 " ' 3.2% DIFF 1.87 DIFF 5. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): TFCT nvzi piDTIntJ nran_nlennra -.11 SELF IGNITION TEMP I ASTM D1929. . 779 'F >_.650 'F RATE OF .BURNING ASTM D635 . 0.0 IN IN . SMOKE DENSITY, ASTM D2843 39.D% TENSILE STRENGTH* ASTM D638 3.6Z DIFF UVM nr nvc ILNZILL WKLNUIN AYILK WLAINLKINU 4500 HOURS XENON ARC METHOD 1 6. MAXIMUM GLASS SIZES COMPLY WITH ASTM E1300 FOR THE DESIGN PRESSURES LISTED. 149- MAX. OVERALL FRAME WIDTH 21" MAX 36.375" MAX. D.L.O. - PANEL WIDTH -- 37.5" MAX. W/ASTRAGAL I FRAME WIDTH N cp �O W � a LL. . ..... . ... STRUCTURAL WHERE WATER INFILTRATION PERFORMANCE IS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING ALL OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HP 0 S T4 0 S HIGH DAM 0 S X 37.5 +55.0 -55.0 +55 0 -55.0 N A +25.0 -25.0 +40.0 -40.0 +50.0 -50.0 +55.0 -55.0 t55.0 XX 74 +50.0 -55.0 +55.0 -55.0 N/A +25.0 -25.0 +40.0 -40.0 N A +55.0 " -55.0 OX or XO 75 +55.0 -55.0 +55.0 -55.0 N A +25.0 -25.0 +40.0 -40.0 N A . +55.0 -55.0 .+55.0 +55.0 OXO 112.5 +55.0 -55.0 +55.0 -55.0 N A +25.0 -25.0 +40.0 -40.0 N .A +55.0 -55.0 +55.0 OXXO 149 +50.0 -55.0 +55.0 -55.0 N A +25.D -25.0 +40.0 -40.0 N A +55.0 -55.0 +55.0 e� i SCALE N.T.S. • BY: SWS cw- By KURT BALTHAZOR ottAwwc J0: FLORIDA P.E. OWG-MA-FLD #56533 SHEET 1 0F 6" SEE DETAIL 3„ 6" 3, „E„ 3" 3� r. 3^ E' 3i SEE DETAIL 'C" I I I I s" 6' s" 3 � m W Q En J J Q CY CY _ O 6„ B O .g a — 6„ 63„ 6" —' to a SEE J Or w w m 3„ T. G, I I 6• SEE DETAIL 6„ #S X 2" #8 x 2" #10 x 5/8" #8 x 2" #10 x 5/8" #10 x 2-1/2". #10 x 1" DETAIL "E" ASTRAGAL p ATTACH ASTRAGAL RETAINER BOLT #10 x 1" STRIKE PLATE TO FRAME #10 x 5/8"' AS SHOWN. DETAIL "D" DETAIL "C" 1 1 I 0.9621 1.375" �•^r""[9 A 1.4377" T LLOOZ INSWING THRESHOLD BUMPER O/S THRESHOLDTH�RREESHOLD HI P THRESHOLD 1 1 1 1.482" 1.75" [�j 1.437" T T T Z—SERIES OfS THRESHOLD HIGH DAM OlS THRESHOLD T4 OIS THRESHOLD O "t N G N 6" ;EE DETAIL C. 6" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGAL DAIS 419107 scALe N.T.S. DWG. B-: SWS CHK. 6Y: DRAWING NO, DWO-MA-FLOi72-07 sHEEr 2 of _ _ 4.. SEE DETAIL 3„ "E" SHT. 2 3" 6" 1 h- ic - o w U a SEE DET1 } "D" SHT. SEE DETAIL o "C" SHT. 2 — — A w 0 Q 6" 6— 3' Add idabli l/ SEE DETAIL commimmg. Woo "F' SHT. 2 B" zdc .ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE DISTANCE MIN 1 /2". 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE 3-- I n L6 3" 6' �3-r 3" I I I I I I i0 w Q a J 0 I_L G H I I .._ I I 9 •.I I L w 6 0 . g v 6" 6" 1.25" MIN L^_' 8� !R..`.�0.25" SHIM 1 - 1 /2" 1 25„ 3' FROM CL —I -- MIN > ", f AND MAX SHIM TYPICAL MASONRY CIL ANCHOR INSTALLATION �t • " s. 1 X BUCK MASONRY COMBINA 1MIN" ANCHOR INSTALLATION MULLION 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM —0.25„ MAX (3) & OX2-1/2„ ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT SHIM Wo D SCREWS OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE I EACH END CL -- I— M; MINIMUM EMBEDMENT OF 1-1/4". w; are 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. TYPICAL WOOD BUCK 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. ANCHOR INSTALLATION INTEGRAL WOOD MULLION (CHS) HARDWARE SCHFDUIF 1.'' KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT. 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. CORRUGATED #tOX2" WOOD SCREW EACH END 6" FROM EACH END 7' OC AND 12" OC ACRYLIC LATEX -- CAULK ACRYLIC i CAULK CL } TION WOOD COMBINATION WOOD (BOXED) MULLION (BOXED) (4WO6D SCREWS" EACH END INTEGRAL WW MULLION (CHS) Lo 00 U p10 Z � J 0 �Q IncW C)Q Q2 LoU OLO 0) y .•- N g � N.T.S. ow BY, SWS Cw. 6Y: DWG-MA-FLU172-07 sHEEr 3 of 4 1' INSULATED GLASS 0.124' HEAT STRENGTHENED DECORATIVE INSERT 0.090' SAFLEX (NOA 20-0622.01) - (OPTIONAL) 0.124' HEAT STRENGTHENED- �.0124' TEMP. BUTYL, FOAM, OR METAL SPACER 1/2' BITE DOW 995 -. - ^`.�S •:`: DOW 995 { i•�Y�4 INTERI O 7YPfCAL GLAZING DETAIL IMPACT RATED GLASS 1' INSULATED GLASS 0.124' HEAT STRENGTHENED .DECORATIVE INSERT 0.090' SAFLEX (NDA 20-0622.01) (OPTIONAL) 0.124' HEAT STRENGTHENMD .0124' TEMP. BUM FOAM. OR METAL SPACER 1/2' BITE DOW 995• 1^: ( --�DOW 995 1-1/4- INSULATED GLASS ' 0.124' HEAT STRENGTHENED... INTERNAL MINIBLINDS 0.090' SAFLEX (NOA 20-0622.01) _ (OPTIONAL) 0.124' HEAT STRENGTHENED .0124' TEMP. METAL SPACER 1/2' BITE DOW 995}}��yy HOT MELT ELASTOMER ^�y :` FOAM GLAZING TAPE EXffB1DB .. .. INTERIO ALTERNATE GLAZING DETAIL IMPACT RATEDGLASS EXMW------r -- RBEMO ALTERNATE GLAZING DETAIL IMPACT RATED GLASS SCAM- N.T.S. Dwc. BY: SWS CHK. BY. OF 4 L. Roberto Longs P. E. 1432Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514008B 434-68"609 Date: 10/10/2017 rilomas(a)I domaspe.com Test Report: N/A Product: Double Door with and without sidelites 12'x6'8" (wood frame) Scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020). Anchor capacity In shear condition: Solid members w/ 8 w/out gap: a. With threads present in shear plane Fastener type: #10 wood screw (NDS 2018, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb = 80,000 psi Side member: Douglas Fir -Larch (6=0.50) Main member: Spruce -Pine -Fir (G=0.42) Side member thickness: t,= 1.000 in Main member thickness: %= 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: Fes, = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: 1m = 1.140 in Mode I,,, qm = 636.5 Ibs/in P = 725.61 Ibs Ka = 2.400 4= 302lbs Mode I, qs = 884 Ibs/in P = 884 Ibs Ka = 2.400 Z,= 368 Ibs Min. Design value: Z= 110 Ibs Mode IT Mode IIIm Mode III, Made IV A: 0.00135 B: 0.000 C: -93.6 P = 263 Ibs Ko = 2.400 Duration Factor: Co = 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs Allowable Design Value (ZCb): Z.= 175 Ibs/anchor Fastener type: 1/4 ITM/ Topcon Tabulated values N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Actual edge distance: 2.50 in A: 0.0007 B: 1.07 C:-427.674 P = 331 Ibs Ko = 2.400 Z= 138 Ibs A: 0.00096 B: 0.57 C:-253.623 Ms = 46.8 in-Ibs P = 297 Ibs Ko = 2A00 A: 0.00107 8: 0.5 C: -267.699 Mm = 46.8 in-Ibs P = 319 Ibs Kb = 2.400 edge distance spacing (in) 2.00 4.00 2.00 130 161 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z-,= 155 Ibs/anchor (per Interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 GA, Steel Tabulated design value: Z= 1266 Ibs Safety factor: Fs= 4 Allowable Design Value (Us): Z.= 316 Ibs/anchor Minimum anchor capacity: 155 Ibs/anchor Note: Anchors with the least capacity Is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors 36.38 36.38 Al Al AY x� 79.25 At Al _ J, L 72.75 37.50 36.38 36.38 37.50 A2 Y Al Y� Al A4Al A4 Al 147.75 1 of 4 79.25 Design pressure: 60.0 psf Zone Area (ftZ) Load (Ibs) Ind. (in) Max. O.C. (In) Anchor Result Cap. (lb,) QtY Load (Ibs) AI 2.3 138 N/A N/A 155 1 138 OK AZ 7.7 463 6.00 21.00 155 5 93 OK A3 1 7.7 1 463 1 N/A I N/A 155 3 154 1 OK Design pressure: 60.0 psf Zone Area (ftz) Load (Ibs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs)Qty Load (Ibs) Al 2.4 146 N/A N/A 155 1 146 OK AZ 7.9 473 6.00 21.00 155 5 95 OK A, 7.8 468 N/A N/A 155 4 117 OK A4 2.3 138 N/A N/A 155 1 138 OK A5 7.7 463 N/A N/A 1 155 3 1 154 OK 5 R dti /z� c1 � STAT OF •;CORtOP. NI It``` Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 434-666-0609 rllomas(WIrlomaspe.com Anchor Locations: Double door 79.25 2 of 4 36.38 t 36.38 P. 6.00 TY� 6.00 TYR 18.19 7YP. 3 0 7yP. I—�{ 6.00 i 6.00 Manufacturer: Masonite Report #: 514008B Date: 10/10/2017 Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, No 27023 Report #: 514008B 434-688-0609 Date: 10/10/2017 rllOmas(EDIrlomaspe.com Double door with sidelites 6.00 TYP. -� 1 37.50 -- 18.75 TYP. 6.00 TYP. 3.0 0 TYP. 36.38 -I- P. �- 18.19 TY—� - 36.38 37.50------�i 6.00 -1 I 18• MAX O.C. I 9.25 J 6.00 3 of 4 S'F•9CP��`� TAT OF ccj �. • r -. Z OR%D * G Z/�sLs/NA �illllllt Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 Manufacturer: Masonite Report #: 514008B 434-688-0609 Date: 10/10/2017 rllomasAirlomaspe.com Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 4 of 4 ���JCS.•.••. V,•��C E N s�..� � �`�. A TAT Of i w Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodlord Rd. Manufacturer: Masonite Lewisville, NC 27023 Report* 514012B 434-688-0609 Date: 10/10/2017 rllomas�0i I rlomaspe. c0 m Test Report: N/A Product: Double Door with and without sidelites 12'x6'8" (composite frame) scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020). Anchor capacity in shear condition: Solid members w/ 4 w/out gap: a. With threads present In shear plane Fastener type: #10 wood screw (NDS 2018, TR12) Nominal diameter: D: 0.190 in Gap: g: 0.0000 in Root diameter: Dr: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb = 80,000 psi Side member: PVC Main member: Spruce -Pine -Fir (Cr--0.42) Side member thickness: t,= 1.000 in Main member thickness: %= 1.500 in Side member dowel bearing strength: F. = 10,000 psi Main member dowel bearing strength: F_ = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode T.,,, qm = 636.5 Ibs/in P = 725.61 Ibs Kb = 2.400 Z„= 302lbs Mode I, qs = 1900 Ibs/in P = 1900 Ibs KD = 2.400 Z,= 792 Ibs Min. Design value: Z= 125 Ibs Mode 11 Mode III Mode III, Mode IV A: 0.00105 B: 0.000 C: -93.6 P = 299 Ibs KD = 2.400 Duration Factor: CD = 1.6 Z= 135 Ibs Z= 221 Ibs Z= 125 Ibs Allowable Design Value (ZCD): Z'= 199 Ibs/anchor Fastener type: 1/4 ZTW Tapcon Tabulated values N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Actual edge distance: 2.50 in A: 0.0005 B: 1.07 C:-681.799 P = 510 Ibs Kb = 2.400 Z= 212 Ibs A: 0.00066 B: 0.57 C: -253.623 Ms = 46.8 in-Ibs P = 324 Ibs KD = 2.400 A: 0.00092 B: 0.5 C:-521.824 Mm = 46.8 in-Ibs P = 529 Ibs KD = 2.400 edge distance spacing (in) 2.00 4.00 2.00 130 161 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z"= 155 Ibs/anchor (per interpolation when needed) Fastener type: #10 Self tapping screw (Calculations per 2015 Aluminum Design Manual, section J.5.5) Nominal screw diameter: D: 0.190 in Screw root area: Ar 0.0151 in' Actual edge distance: de: 1.085 in Screw shear ultimate strength: Fn 54.0 ksi Per table J3.2 of 2010 Steel Construction Manuall4th Edition Side member material: Vinyl PVC Main member material: 6063-T5 aluminum Thickness: tl 1.000 in Thickness: t2 0.052 in Ultimate tensile strength: Fto 14 ksi Ultimate tensile strength: Fw2 22 ksi Nominal strength per bearing (side member): Rn = 2Dt2Ft , Rn1= 5320 Ibs (Eq J.5-12) Nominal strength per bearing (main member): Rn = 2Dt2Ft Z Rn2 = 435 Ibs (Eq J.5-12) Nominal strength per tilting: Rn = 4.2(tZ31))1/21t�2 Rn = 478 Ibs (Eq J.5-13) Nominal screw shear strength: Rn = ArF,,,/1.25 Rn = 654 Ibs (Eq J.5-14) Safety factor: o= 3 Allowable shear and bearing capacity: Pm 145 Ibs/anchor Fastener type: #10 Self tapping screw (Calculations per AISI 5100-16 and AISC 2017) Nominal screw diameter: D: 0.190 in Screw shear ultimate strength: F,,, 54.0 ksi Screw root area: Ar 0.0151 in Per table J3.2 of 2010 Steel Construction Manuall4th Edition Side member material: Vinyl PVC Main member material: Metal framing Thickness: tj 1.000 in Thickness: t2 O.C'• Ultimate tensile strength: Ft 14 ksi Ultimate tensile strength: Fe �t1�.I Nominal strength per tilting: Rn = 4.2(tz3D)vzFuz Rn = 1001 Ibs (Eq E4.3.1-1) ��Y � R . .I Nominal strength per bearing (side member): Rn = 2.7DtjFW Rn1= 7182 Ibs (Eq E4.3.1-2 and -4) `N 1vN� • •CC• A•' Nominal strength per bearing (main member): Rn = 2.7Dt2F 2 Rn2 = 1280 Ibs (Eq E4.3.1-3 and -5) • �G L `Y S • (� �j • • Nominal screw shear strength: Rn = ArF,,,/1.25 Rn = 654 Ibs ` • � •. i Safety factor: o = 3 •+�. * • R AF• *�- Allowable shear and bearing capacity: Pm 218 ibs/anchor e Minimum anchor capacity: 145 Ibs/anchor • :L' `_ OF • Note: Anchors with the least capacity is used for calculations to quaff anchors with higher capacity. �V'��►s; Z O R OP '41' 70NAL'ti��� 1111.1 Luis R. Lomas P.E. FL No.: 62514 1 of 4 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514012B 434-688-0609 Date: 10/10/2017 rllomasCa)Irlomaspe.com Anchor calculations, minimum reaulred anchors 36.38 36.38 Design pressure: 60.0 psf E EA1 79.25 1 � 72.75 37.50 36.38 36.38 37.50 Al � Y_ _Y Al A2 Al A4 A4 Al 147.75 Anchor Locations: 79.25 Zone Area (ft2) Load (Ibs) Ind. (in) Max. O.C. Anchor Result Cap. (Ibs)Qty Load (Ibs) AI 2.3 138 N/A N/A 145 1 138 OK AZ 7.7 463 6.00 21.00 145 5 93 OK A3 7.7 463 N/A N/A 145 4 116 1 OK Design pressure: 60.0 Psf Zone Area z (ft) Load (lb.) Ind. (in) max. O.C. (in) Anchor Result Cap. (Ibs) Qty Load (Ibs) Al 2.4 146 N/A N/A 145 2 73 OK A2 7.9 473 6.00 21.00 145 5 95 OK A, 7.8 468 N/A N/A 145 4 117 OK A4 2.3 138 N/A N/A 145 1 138 OK As 7.7 463 N/A N/A 145 4 1 116 OK Double door 36.38 36.38 6.00 TYP. 6 3.0 _ry 18.19 iYP. 6.00 79.25 6.00 . 2 of 4 v•'.�C E N`s ' 51 '* TAT OF i w1 � SjONA` Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer: Masonite Lewisville, NC 27023 Report #: 514012B 434-688-0609 Date: 10/10/2017 rilomasCaJrlOmasoe.cOm Double door with sidelites 6.00 TY00 P. L 37.50 18.75 TYP. — 6. TYP. 3.00 TYP. 1,75 36.38 16.19 IYP. — r— 36.38 - 37.50 — III 6.00 I is, MAX O.C. I I 9.25 6.00 3 of 4 \� �itlilll///�/z CEO i Offo TAT OF i w S , ORibA %s7ONAL��`� I I Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 434-688.0609 rllomas(alrlomaspe.com Manufacturer: Masonite Report #: 514012B Date: 10/10/2017 Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 4 of 4 Luis R. Lomas P.E. FL No.: 62514 9/2/2020