HomeMy WebLinkAboutSTANDING SEAMS NOA 2020 CODEProfessionalBusiness &
1305 Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications I contact us BC15 Site Map Links Search
Florida
product Approval
r 4410)
USER: Public User
Proouct Approval Menu > Product ar Application Search > Aupllcatlon List > Application Detail
FL # FL20484-R2
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST.
FAYETTEVILLE, NC 28301
(910) 813-2432
rblake5)unioncorrugating.com
Authorized Signature Randy Blake
rblake@unioncorrugatin9.rum
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Bala Sockalingam
Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 09/07/2027
Validated By Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL20484 R2 COI CertiflcateIntependenLe.pdf
Standard
Year
FM 4470
2016
TAS 125
2003
UL 1897
2012
UL 580
2006
Product Aooroval Method Method 1 Ontion D
Date Pending FBC Approval 10/22/2020
Date Approved 12/16/2020
Summary of Products
FL #
Model, Number or Name
Description
Z0484.1
5V
Min 26 ga., 24" wide through fastened panel over 15/32" thick
plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20484 R2 II EvaluationRep2rtC2401 1j&
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-169 Evaluation Reports
Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. & FL20484 R2 AE Evaluation ReportC2401 L.pdf
169.0 psf @ fastener spacing of 6" o.c. Created by Independent Third Party: Yes
20484.2 Atfiextage-Lak II
tfiM 26 ga., 16* 7/16" thick
OSB 9 15/32"B1111ti 1kViywood
Installation Instructions
Limits of Use J
Approved for use in HVHZ: No
FL20484 R2 II Evaluation ReportC2401 2.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-131.5
Evaluation Reports
Other: Maximum uplift load of 131.5 psf @ seam fastener
FL20484 R2 AE Evaluation Re=C2491 2 odf
spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA
Created by Independent Third Party: Yes
rated plywood with retainer strap.
20484.3
Aluminum Advantage-Lok II
Max 16.375" wide, nom 0.032" thick (min.) aluminum
concealed fastener roof panel over min 15/32" thick plywood
deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 II Evaluation ReportC2401 3.p_df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c.
FL20484 R2 AE EvaluationReportC2401 3. dp_t
and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32"
Created by Independent Third Party: Yes
plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener
spacing of 4.63" o.c, with adhesive in 15/32" plywood.
20494.4
Aluminum SLI50
Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock
standing seam metal panel over min 15/32" thick plywood deck
or 7/16" thick OSB
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20484 R2 II EvaluatlonReportC2401 4.p&
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-86
Evaluation Reports
Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and
FL20484 R2 AE Eva luationReportC2401 4.pdf
78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16"
Created by Independent Third Party: Yes
OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with
adhesive in 15/32" plywood.
2D484.5
MasterRib
Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood or 7/16" thick DSB
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20484 R2 II Evaluation ReoortC2401 Spf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-124 Evaluation Reports
Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. & FL20484 R2 AE EVaIuationReportC24D1 5.odf
124.0 psf @ fastener spacing of 6" o.c. Created by Independent Third Party: Yes
20484.6 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20484 R2 II EValuationReoprtC2401 6.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-88.5 Evaluation Reports
Other: Uplift load of 56 psf for Fastening System 1. Uplift load FL20484 R2 AE EvaluationRepartC2401 6.p f-
of 88.5 psf for Fastening System 2. Created by Independent Third Party: Yes
20484.7
ML150
Max 16.5" wide, min 24 ga. steel standing seam panel over
15/32" thick plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20484_R2_11 Eva luationReportC2401 7.pdf
20484.8 1 PER or R Panel
Min 26 ga., 36" wide through fastened panel over 15/32" thick
plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.5
Other: Uplift load of 30.0 psf at fastener spacing of 48" c.c.
and 161.5 psf at fastener spacing of 6" o.c.
SL175
Installation Instructions
F1,20484 R2 II EvaluationReoortC2401 8.pdf
Verified By: Bala Sockalingam P.E. 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL20484 R2 AE EvaluatlonReDOrtC2401 B.pQ
Created by Independent Third Party: Yes
Max 18" wide, min 24 ga., snap -lock standing seam metal
panel over 15/32" thick plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20484 R2 II EvaluationReDortC24D1 9.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5 Evaluation Reports
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and FL20484 R2 AE EvaluationReoortC2401 9.W
78.6 psf @ clip spacing of 8" ox with felt. Uplift load of 93.5 psf Created by Independent Third Party: Yes
@ clip spacing of 12" O.C. with self -adhering membrane.
Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The Stale of Florida Is an AA/EEO employer. geR.xd9 ht 2007-2013 State of Florida.:: iv y Statement :: AcceswWIitV Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mail address released In response to a public -records request, do not send electronic
mall to this el Instead, contact the office by phone or by bradillonal mall. If you have any questions, please contact 8S0.487.1395. "Pursuant to Sadler 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an small address which can be made available to the public. To determine If you are a licensee under Chapter 455, E5., please click Sre .
Product Approval Accepts:
7T ® ® Klv
securitymErxlcs
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA. ADVANTAGE-LOK II'
FLORIDA BUILDING CODE 7TH EDITION (2020)
FLORIDA PRODUCT APPROVAL.
FL 20484.2-R2
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492.5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C2401-2
Date: 10.10.2020
C+CI(AL/j,
pE N SF • 9ny r:
No 62240
: Cr
�'• STATE OF :1 ;
0 Ft
l0.1o.2a2o
FL 20484.2-R2
C2401-2
10.10.2020
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: Advantage-Lok II Panel
Panel Description: Max. 16" wide coverage with 1 " high ribs
Materials: Minimum 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755). Corrosion resistant as per FBC 2020 Section 1507.4.3.
Deck Description: Min. 7/16" thick OSB or min. 15/32" thick APA rated plywood or
min. '/4" thick wood plank (min SG of 0.42) for new and existing
constructions. Designed by others and installed as per FBC 2020.
New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1.
Required for new construction.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 2:12.
Design Uplift Pressure: 30.0 psf at panel fastener spacing of 13-7/8" o.c. along seam
(Factor of Safety = 2) 63.5 psf at panel fastener spacing of 9-1/4" o.c. along seam
78.5 psf at panel fastener spacing of 4-5/8" o.c. along seam
112.5 psf at seam fastener spacing of 4-5/8" o.c. along seam with
3/16" diameter bead adhesive in panel seam
131.5 psf at seam fastener spacing of 4-5/8" o.c. along seam into min.
15/32" thick APA rated plywood with retainer strap
Panel Attachment: #10-12 pancake head wood screws along panel seam. Fasteners are
corrosion resistant as per FBC 2020 Section 1507.4.4. Fastener shall
be of sufficient length to pcnetrate through the deck a minimum of
3/8".
Retainer Strap: 5" wide, 24 ga., 50 ksi strap fastened to deck with 2 rows of 410-12 x
1" long pancake head screws at 12" o.c. spacing and 6" staggered. The
strap is continuous over the entire comer or edge roof zones. Prior to
the panel installation, two rows of 3/8" bead of adhesive are field
applied along the length of the strap and a row of 3/8" bead of
adhesive on the male leg of panel.
Seam Adhesive: Sikaflex-201 or APS 500 Advance Polymer Sealant. In lieu of
Sikaflex or APS sealant, adhesive with greater or equal tensile
properties may be used.
FL 20484.2-R2
C2401-2
10.10.2020
Page 3 of 3
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems' or TAS 125-03 `Standard Requirements for Metal Roofing
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described herein has demonstrated compliance with FBC
2020 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA for use of this product in High
Velocity Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2020 Section 1505 and current
approved rooting materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: UL580 & UL1897 Test Reports
PRI Construction Materials Technologies
UCC-006-02-1 Rev 1, Reporting Date 2/10/12
TAS 125 Test Report
Farabaugh Engineering and Testing Inc.
Project No. T302-16, Reporting Date 11/16/16, Revised Date 1/18/17
Project No. T303-16, Reporting Date 11/16/16, Revised Date 1/18/17
Project No. T304-16, Reporting Date 11/16/16, Revised Date 1/18/17
NEW JNDERLAYMENT SEE DETAILS 1 & 2 PANEL OVERLAP PANEL FASTENER ROOF PANEL
0 MAX. 13-7/6' G.C.
EXISTING UNDERLAYMENT 11II
(OPTIONAL) EXISTING SHINGLES DECK ATTACHMENT AND OSB 7/16' THICK (MIN.) OR II
(OPTIONAL) SUPPORTS MUST BE PLYWOOD 15/32' THICK (MIN.)
RAFTER/JOIST/TRUSS DESIGNED AND INSTALLED
Al MAX. 24. O.C. BY OTHERS
TYPICAL PANEL INSTALLATION X-SECTION
NEW UNDERLAYMENT
MIN 26 C0. PANEL
NEW UNDERLAYMENT
EXISTING UNDERLAYMENT
(OPTIONAL)
MIN 26 GA PANEL
NEW UNDERLAYMENT
EXISTING UNDERPAYMENT
(OPTIONAL)
3/8' BEAD OF (2) 3/8' BEAD OF PANEL FASTENER
ADHESIVE ADHESIVE 0 MAX. 4-5/8' O.C.
DECK ATTACHMENT AND
RETAINER STRAP PLYWOOD 15/32" THICK (MM.) SUPPORTS MUST BE 5" WIDE, 24 GA.
DESIGNED AND INSTALLED RAFTER/JOIST/TRUSS J
BY OTHERS AT MAX. 24" D.C.
PANEL INSTALLATION WITH RETAINER STRIP
#10-12 PANCAKE HEAD
WOOD FASTENER
EXISTING SHINGLES
(OPTIONAL)
DETAIL 1 OR
PL PLYWOOD 615/32N THICK- THICK ) (MIN.)
3/16" BEAD
#10-12 PANCAKE HEAD
WOOD FASTENER
�lEXISTING SHINGLES
(OPTIONAL)
DETAIL 2 `PLYWOOD 15/32K ) OR
THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
PANEL
FASTENER
SPACING
ALONG RIB
MINIMUM
SUBSTRATE
SEAM
ADHESNE
DIAMETER
RFTA;NER
STRIP
PRESSURF
(PSF)
1T 7/8'
7/7C OSB
NONE
NONE
30.0
9-1/4
7/i6" OSB
NONE
NONE
63.5
4-5/8"
7/16' DSB
NONE
NONE
78.5
4-5/B"
IC OSB
3/T 6'
NO
112.5
4-5/8"
15/32' PLY
3/8"
REQUIRED
131.5
GENERAI NOTES
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS ARE SHALL BE 26 GA EFFECTIVE COVERING WIDTH OF
OF PANEL = 16".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE.
5. ALL FASTENERS MUST BE IN ACCORDANCL WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
B. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPUCATION AND ARE THE RESPONSI911_IT+ OF OTHERS.