HomeMy WebLinkAboutEnergy Efficiency CodeM
�z
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MELVILLE 3v G-,-e,4d oet >+L-�
Builder Name:
Street: T-r ? %'e,c e FL ' y Jtj
Permit Office: ST LUCIE
City, State, Zip: FORT PIERCE, FL,
Permit Number.
Owner:
Jurisdiction: 611000
Design Location: FL, Fort Pierce
uction or e)dsting New (From Plans)
9. Wall Types(3738.3 sgft.)
Insulation Area
r
a. Concrete Block - Int Insul, Exterior
R=4.1 23 UG ftz
ly or mufttple family Single-family
b. Frame -Wood, Exterior
R=19.0 660.00 ftz
units, if multiple family 1
c. Frame - Wood, Adjacent
R=11.0 433.33 ftz
3
d. other (see details)
R= 273.33 f12
4. Number of Bedrooms
10. Ceiling Types (3223.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 3223.00 ft2
6. Conditioned floor area above grade (ftz) 3223
b. NIA
R= ft'
R= ft
c. N/A
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(559.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 644.6
a. U-Factor: Dbl, U=0.32 559.50 ft2
SHGC: SHGC=021
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: NIA fe
a. Central Unit
54.0 SEER:16.67
SHGC:
c. U-Factor: WA fE
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
50.0 COP:0.50
SHGC:
Area Weighted Average Overhang Depth: 6.201 ft.
Area Weighted Average SHGC: 0.210
14. Hot water systems
a. Natural Gas Tankless
Cap: 1 gallons
8. Floor Types (3223.0 sgft.) Insulation Area
EF: 0.590
a. Slab -On -Grade Edge Insulation R=0.0 3223.00 ftF
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft
15. Credits
None
Total Proposed Modified Loads: 43.63
PASS
Glass/Floor Area: 0.174 Total Standard Reference Loads: 57.06
k
I hereby certify that the plans and specifications covered by
Review of the plans and
01 E SIN
this calculation are in compliance 'th th Florida Energy,
Code.
specifications covered by this
calculation indicates compliance
ti+�;' - 0*0
�3'•F ` = ; ;,,��� 6
Florida Energy Code.
= �";'' « 0
with the
,:.r"••
y
PREPARED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a
�'C
p
1 hereby certify that this building, as designed, is in compliance
Florida Statutes.
r
� J5
CDU
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
_
DATE:
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
i
i
ACTOR COP
10:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MELVILLE
User
1
ST LUCIE
611000
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 3223
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address,
St. Lucie
FORT PIERCE,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
3223 32230
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Intl ID(, Finished Cooled . Heated
1
Main
3223 32230 Yes 1
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 266 ft 0
3223 ft'
—
0 0 1
ROOF
/
v #
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emift
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 3491 ftz 0 ftZ Medium
0.75
No 0.9
No 20 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 In)
Area
RBS IRCC
1
Full attic
Unvented 0
3223 ft2
N N
CEILING
#
Ceiling Type
Space R Value Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
Main 1 3223 fF
0.11
Wood
CO3NTRACTOR COPY
6/28/201510:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar
Below
Space
1
N
Exterior
Concrete Block - Int Insul
Main
4.1
51
10
510.0 ft2
0 0.75
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.1
83
10
830.0 ft2
0 0.75
0
3
S
Exterior
Concrete Block - Int Insul
Main
4.1
32
10
320.0 ft2
0 0.75
0
4
W
Exterior
Concrete Block - Int Insul
Main
4.1
66
2 10
661.7 fF
0 0.75
0
5
S
Garage
Frame - Wood
Main
11
22
10
220.0 ft2
0.23 0.75
0
_ 6
W
Garage
Frame - Wood
Main
11
21
4 10
213.3 ft2
0.23 0.75
0
7
N
Exterior
Frame - Wood
Main
19
27
4 10
273.3 ft2
0.23 0.75
0
8
E
Exterior
Frame - Wood
Main
19
19
4 10
193.3 ft2
0.23 0.75
0
9
S
Exterior
Frame - Wood
Main
13
27
4 10
273.3 fF
0.23 0.75
0
10
W
Exterior
Frame - Wood
Main
19
19
4 10
193.3 ft2
0.23 0.75
0
11
NE
Exterior
Concrete Block - Int Insul
Main
4.1
5
10
50.0 ft2
0 0.75
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
Main
None
.4
3
8
24 ft2
2
S
Insulated
Main
None
.46
3
8
24 ft2
3
E
Insulated
Main
None
.4
2
8
8 21.3 ft2
WINDOWS
Orientation shown Is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Double
Yes
0.32
0.21
18.1 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
None
2
N 1
Vinyl Low-E Double
Yes
0.32
0.21
9.0 ft2
2 ft 0 in
1 ft0 in
Drapes/blinds
None
3
E 2
Vinyl Low-E Double
Yes
0.32
0.21
111.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
None
4
E 2
Vinyl Low-E Double
Yes
0.32
0.21
144.0 ft2
16 ft 0 in
1 ft 0 in
-Drapes/blinds
None
5
NE 11
Vinyl Low-E Double
Yes
0.32
0.21
18.8 fie
16 ft 0 in
1 ft 01n
Drapes/blinds;
None
6
S 3
Vinyl Low-E Double
Yes
0.32
0.21
63.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
None
7
W 4
Vinyl Low-E Double
Yes
0.32
0.21
75.0 ft2
2 ft 0 in
f ft 0 in
Drapes/brinds
None
8
W 4
Vinyl Low-E Double
Yes
0.32
0.21
15.8 ft2
2 ft 0 in
1 ft0 in
Drapesiblinds
None
9
W 4
Vinyl Low-E Double
Yes
0.32
0.21
24.0 ft2
5 ft 0 in
1 ft 0 in
Drapes/blinds
None
10
NE 11
Vinyl Low-E Double
Yes
0.32
0.21
20.0 ft2
2 ft 0 in
1 ft0 in
Drapes/bfinds
None
11
W 10
Vinyl Low-E Double
Yes
0.32
0.21
20.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
None
12
N 7
Vinyl Low-E Double
Yes
0.32
0.21
20.0 ft2
2 ft 0 in
1 ft0 in
Drapesiblinds
None
13
E 8
Vinyl Low-E Double
Yes
0.32
0.21
20.0 fF
2 ft 0 in
1.ft 0 in
Drapes/blinds
None
Tii R
6/28/201510:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
635.2 ftz
384 fie
46 ft loft 11 '
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
" 1 Wholehouse
Best Guess
.0005
4227 232.06 436.42 .365 7.869
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1 A
1 B
Electric Strip Heat
Electric Strip Heat
None
None
COP:0.5 16 kBtu/hr 1
COP:0.5 34 kBtu/hr 1
sys#1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 A
1 B
Central Unit
Central Unit
None
None
SEER:16 18 kBtu/hr 540 cfm 0.5 1
SEER: 17 36 kBhdhr 1080 cfm 0.5 1
sys#1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
. EF Cap Use SetPnt Conservation
1
Natural Gas Tankless
Exterior
0.59 1 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft,
DUCTS
/
#
— Supply —
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
Attic 6 644.6 It Attic
161.15 Default Leakage Main (Default) (Default)
1 1
a ice` � ' "Y" � "• t� f � ra ; ,
6/28/201510:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
a0ivd
OOp N n� �� mcmo (COW
zzz 'nr ran corn (o(o
ram.
o mm mm mm mm
mm
000MCLCL
°' tin �n cmom m(mo
MO
O
K, - m GOOD CDCO Cocotow Coocmo
0000
mm mm aom mm
r-r. r.r• mm co to
0
nti COh tWW cow
lu
mm mm mm mao
r n r.r. corn mm
Q. y
a m mm mm mao mm
W LL m m m r.i. nr. com corn
~ c
U
M ti� nr- (Coco WID
�Qa
N co
n� rn cow(Coco mo((D
v
a)
N
mm mm mm mm
r•r. ran mm mm
O
0 ritili N
z � a a ¢a ¢a
x
0
m
m tca ccv o
M" MOM W a)
o 0 O 7
0 oWE E� c c c c
R` odd m
U=9 V1 U U = S
m
0
m
a)
' of
m
a
C- m
CL
E
0
U
v
to
0
v
c
a
a0i
tm
0
0
m
Q
N
t
7
a7
T
d
W
2
IL
0
0
co
N
6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
FORT PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
lip,its- .r{ :`°; L\;
� 3
6128/201510:01 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6