Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
8404 Paso Robles Blvd - REVISIONS - SS Designs
FOR CODY KOESTER 8404 PASO ROB ES B VD FORT PUCE, FEOR DA 34951 TYP. EAVE MODULE ROOF LAYOUT NTS PROJECT DESCRIPTION: 23 MODULES - MISSION SOLAR: MSE345SX5T 23 INVERTERS - ENPHASE: IQ7-60-2-US GOVERNING CODES: 2020 FLORIDA PLUMBING CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA MECHANICAL CODE, 7TH EDITION NEC 2017 NFPA 1 2018 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Digitally signed by Andrew Hall Andrew D. Hall, PE FL87479 Date: 2022.02.02 19:18:44 -05'00' DISCONNECT MIN. 4' CLEARAN PER NEC 110.26 ,,���....0All II EIVS�.�� No 87479 00: STATE OF �:�40 WINDSPEED DESIGN DATA PER FBCR 2020 WIND SPEED 170 MPH RISK CATEGORY II EXPOSURE C GUST FACTOR ±0.18 "A" DIMENSION 3 Ft ROOF PRESSURE FOR COMPONENTS AND CLADDING GABLE ROOF ZONE 1 +23.3 PST -57.6 PSF ZONE 2E +23.3 PSF -57.6 ESE ZONE 2N +23.3 PSF -84.1 PSF ZONE 2R +23.3 PSF -84.1 PSF ZONE 3E +23.3 ESE -84.1 PSF HIP ROOF ZONE 1 +23.3 PSF -52.3 PSF ZONE 2R +23.3 PSF -68.2 PSF ZONE 2E +23.3 ESE -73.5 ESE ZONE 3 +23.3 ESE -73.5 ESE 6ahle and Flat knots T° < 0 S 45' Hip fteah 70 < H S 451 r m 0 Y U 0 m N O N N Z N m \ Q o z Li3LLJ z c Q U p 0 0 U") J U M Z o O � H � c O J Q— Z��� H g w c) W O J W U = � r7 Ut N z N z cl- W to W w ray o V d H z D GENERAL NOTES: 0 J 1. THIS IS TO CERTIFY THAT TO THE BEST OF DRAWING INDEX: C4 Of m MY KNOWLEDGE AND BELIEF, THESE PLANS CD oco w CONFORM WITH FLORIDA BUILDING CODE 2020 o o WITH ALL SUPPLEMENTS AND ADDITIONS. S-1 COVER Y 2. ALL PRODUCTS TO BE INSTALLED PER S-2 ARRAY LAYOUT 8C DETAILS o MANUFACTURER'S WRITTEN SPECIFICATIONS. S-3 ELECTRICAL I, ANDREW D. HALL PEA 87479 AN ENGINEER S-4 NOTES o N z o 00 LICENSED PURSUANT TO CHAPTER 471, CERTIFY S-5 SPECIFICATIONS THAT THE PV ELECTRICAL SYSTEM AND S-6 SPECIFICATIONS ELECTRICAL COMPONENTS ARE DESIGNED AND wLLJ Of o APPROVED USING THE STANDARDS CONTAINED IN S-7 SPECIFICATIONS 0- Q THE MOST RECENT VERSION OF THE FBC, FBC S-8 SPECIFICATIONS DWG. NO. 107. S-9 SPECIFICATIONS S-1 w 0 U 3/8"-16 X 3/4" HEX HEAD BOLT 3/8" - 16 FLANGE NUT PV MODULES K2 SPLICE FOOT X EXISTING ROOF TRUSS EVEREST IMC CLIP EVEREST 1/2 PLYWOOD EXISTING UNDERLAYMENT (2) 5/16" DIA SS LAG SCREW 2-1/2" EMBED MIN. TYPICAL SHINGLE ROOF ATTACHMENT EVEREST EC CLIP (TYP) NTS (2) 5/16" DIA SS LAG SCREW 2- K2 SPLICE FOOT (TYP) I L I v I L v v [kin] NFRFU IM(. (.1IP THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. EVEREST CROSSRAIL 48-X (TYP) KL SF'LIGL ruin x (TYP) (TYP) MISSION SOLAR: MISSION SOLAR: w MSE345SX5T EVEREST IMC CLIP MSE345SX5T (TYP) (TYP) (TYP) Q rZ EVEREST IMC CLIP K2 SPLICE FOOT X (TYP) (TYP) TYPICAL SHINGLE ROOF LAYOUT NTS EVEREST EC CLIP (TYP) n n "� EVEREST CROSSRAIL 48-X (TYP) \_EV )EST EC CLIP J EW �• �i No 87479 STATE OF �:��/ ,.r4 O R \ O P `,�,�. �` •'• J J Q 2 Q m Y W U v J J V) z o o H O O Q OJQ zw--d- H L� 00 W O J W U = � r7 H LnCD V( CV z N z r J 0 W cn W z D O a_ H z D cn O W L J Lo w m Q O o w U � C) � U d C) L+1 0 C) LI)O ¢ p n Z L0U � ZLLJ C Q J w c U d Q Q DWG. NO. S-2 NI L21 IL1 METER 0 NI L21 IL1 L1 30 NEUTRAL GROUND AC PANEL 150 AMP/240V #10 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLICATION USE PVC OR LFMC/LFNMC CONDUIT #10 11 THWN-2 (3 CONDUCTOR) LOCKABLE FUSED PV AC DISCONNECT 30A 240V 2-POLE 30A RK-1 FUSE G 3/4 EMT, FMC, FOR EXTERIOR APPLCATION USE PVC OR LFMC/LFNMC CONDUIT #10 THWN-2 (3 CONDUCTOR) 3/4" EMT, FMC, FOR EXTERIOR APPLCATION USE PVC OR LFMC CONDUIT #6 THWN-2 L1 I I I I F=a NEUTRAL ► GROUND THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. NOTE: ALL INVERTERS ARE EQUIPPED W/ INTERNAL RAPID SHUTDOWN SYSTEM PER NEC 690.12 ENPHASE Q CABLE Q-12-10-240 (TYP) #6 BARE COPPER J ENPHASE IQ COMBINER PLUS W/ (2) 20 AMP BREAKER SOLADECK COMBINER BOX 60OV/ NON -FUSED OR SOLTECTION RESIDENTIAL TRANSITION BOX GEC BOND AT RACKING SYSTEM - (SEE NOTE #2) Ill ENPHASE Q CABLE Q-12-10-240 (TYP) AC Al DC DC NO. 1 NO. 12 NO. 1 NO. 11 AC AC DC DC MISSION SOLAR: MSE345SX5T W/ ENPHASE I07-60-2-US INVERTER EVEREST CROSSRAIL 48-X (TYP) NOTE: ALL STRINGS TO HAVE TERMINATORS & SEALING CAPS INSTALLED PER MANUFACTURER'S SPECIFICATIONS I ENPHASE Q CABLE MISSION SOLAR: MSE345SX5T Q-12-10-240 W/ ENPHASE IQ7-60-2-US (TYP) INVERTER ��.` P •'� �C E N SF• �! '��� No 87479 ' c= 0: STATE OF :4 lo J J Q 2 Q m m im W Y U U v J J U) r7 z o C) rry O Q D r o O J 0 Q_ z W O i W U = M H n N Z CV z a M W N" W ``' � o U cl- H z D 0 J 07 N Ck� O H J n W m j Y K U � O O Q � U 0- 41 O =E O� Q 00 (/7 Z w w w O M J w U 0— Q W. NO. S-3 J Q U Of U W J W THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D MODULE SPECIFICATION MODULE MAKE MISSION SOLAR MODULE MODEL MSE345SX5T FSEC CERTIFICATION # PMAX (STC) 345 W VOC (STC) 41.00 V VMPP (STC) 33.37 V ISC (STC) 10.92 A IMPP (STC) 10.34 A NOCT 44 C TC ISC 0.039 %/C TC VOC -0.262 %/C TC PMPP -0.361 %/C OPERATING TEMP. -40-+85 C SAFETY LABELS AND MARKINGS GENERAL NOTES: 1. EQUIPMENT SUCH AS INVERTERS AND SOLAR MODULES HAVE PRE -APPLIED LABELS FOUND HEREIN SHALL BE APPLIED TO SUCH EQUIPMENT FOR INFORMATIONAL PURPOSES. 2. LABELS AND MARKINGS SHALL BE APPLIED TO COMPONENTS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF NEC. 3. ALL REQUIRED PRODUCT SAFETY AND WARNING SIGNAGE SHALL BE UV RESISTANT OUTDOOR -RATED LAMINATED VINYL IN ACCORDANCE WITH ANSI Z535.4-2011. 4. ALL LABELS SHALL BE REFLECTIVE PER NFPA 11.12 SAFETY LABELS AND MARKINGS LEGEND A. LOCATION OF SERVICE DISCONNECTING MEANS. APPLY TO MAIN SERVICE DISCONNECTING MEANS AND PV DISCONNECTING MEANS AT POCC. MAIN SERVICE DISCONNECT MARKING A LABEL SHALL BE PERMANENTLY AFFIXED TO THE MAIN SERVICE DISCONNECT PANEL SERVING ALTERNATING CURRENT (AC) AND DIRECT CURRENT (DC) PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL BE RED WITH WHITE CAPITAL LETTERS AT LEAST 3/4 IN. IN HEIGHT AND IN A NONSERIF FONT, TO READ: "WARNING: PHOTOVOLTAIC POWER SOURCE." THE MATERIALS USED FOR THE LABEL SHALL BE REFLECTIVE, WEATHER RESISTANT, AND SUITABLE FOR THE ENVIRONMENT. CIRCUIT DISCONNECTING MEANS MARKING A PERMANENT LABEL SHALL BE AFFIXED ADJACENT TO THE CIRCUIT BREAKER CONTROLLING THE INVERTER OR OTHER PHOTOVOLTAIC SYSTEM ELECTRICAL CONTROLLER SERVING AC AND DC PHOTOVOLTAIC SYSTEMS. THE LABEL SHALL HAVE CONTRASTING COLOR WITH CAPITAL LETTERS AT LEAST 3/8 IN. HEIGHT AND IN A NONSERIF FONT, TO READ: "PHOTOVOLTAIC DISCONNECT." THE LABEL SHALL BE CONSTRUCTED OF DURABLE ADHESIVE MATERIAL OR OTHER APPROVED MATERIAL. INVERTER SPECIFICATION INVERTER MAKE ENPHASE INVERTER MODEL IQ7-60-2-US MAX AC POWER OUTPUT 250 VA MAX. INPUT VOLTAGE 48 V NOM. DC VOLTAGE @ 240V 240 V NOM. AC VOLTAGE 16-48 V MAX. CONTINUOUS OUTPUT CURRENT 1.00 A MAX. DC CURRENT 15.0 A MAX. DC POWER (STC) 350 W CEC EFFICIENCY 97 % N AN EMERCENCY CONTACT US SOLAR 1-800-J51-J4J0 SOLAR PHOTOVOLTAIC SYSTEM A� —WARNING— AUTHORIZED PERSONNEL ONLY RATED AC CURRENT: 28.8A NOMINAL AC VOLTAGE: 240V LOCATION: MAIN PV PANEL PHOTOVOLTAIC DISCONNECT Ai —WARNING— ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LOCATION: AC DISCONNECT(S) HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. NOTES: 1. ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE MANUFACTURERS RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, STATUES AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. 3. ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). 4. THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT EXHAUSTIVE. IT REMAINS THE CONTRACTORS RESPONSIBILITY TO ACHIEVE THE PROPOSED INSTALLATION, IN FULL EXERCISE OF AND COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. 5. PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS BE ENERGIZED IN THE OPEN POSITIONS. SIGN SHALL READ "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION OR EQUIVALENT. 6. PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12. 8. PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY FOR INTERCONNECTION. 9. CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT SUNLIGHT. WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 3.OM (10ft) OR 10 PERCENT OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICH EVER IS LESS. NEC 310.15 (B)(2) 10. ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON INTERVALS AND BY METHODS REQUIRED BY THE NEC. 12.PV ARRAY INTERCONNECTION TO BE MADE WITH BACK -FEED BREAKER. 13, GFI BUILT IN TO ALL INVERTERS. SAFETY LABELS A� —WARNING— ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED AUTHORIZED PERSONNEL ONLY LOCATION: DISCONNECTS, INVERTERS, JUNCTION BOXES, OTHER ENCLOSES HOLDING DC CONDUCTORS EMERGENCY RESPONDER: THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SWITCH TO �PEM-CTR'cSHUTDOWN THE 'OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM At. :�6 ENSNo 87479 ' 0: STATE OF •:��/ 0 R. ,SS�ONAllll � ,E���`� J mm 0 Y W U 0 U uw I m N Z N 0 z w z Q U mm v J J L z o O H � O Q r Co 0 U oJo Q z w o H - woJ W H Ln Vt CV z N z W co W z � o H z 0 J m W J w m o o) U Q O O U (� i �i 00 C) cn Z U cn (n w w w U d Q �Z DWG. NO. S-4 Product Type MSExxxSXST (xxx=P-) Solar Cells P-type mono -crystalline silicon Power Output P- W p 330 335 340 345 Cell Orientation 60 cells (6x10) Module Efficiency % 17.9 18.2 18.5 18.7 Module Dimension 1748mm x 1054mm x 40mm Tolerance % 0/+3 0/+3 0/+3 0/+3 Weight 20.3 kg (44.8lbs.) Short Circuit Current Isc V 10.72 10.78 10.86 10.92 3.2mm, tempered, low -iron, Open Circuit Voltage Voc A 40.40 p 9 40.58 40.82 41.00 Front Glass anti -reflective Rated Current Imp V 10.05 10.14 10.24 10.34 Frame Anodized Rated Voltage Vmp V 32.85 33.03 33.20 33.37 Encapsulant Ethylene vinyl acetate (EVA) Fuse Rating A 20 20 20 20 Protection classIP67 System Voltage V 1000 1000 1000 1000 Junction Box with 3 bypass -diodes Cable 1.0m, Wire4mmz (12AWG) Connector Staubli PV-KBT4/611-UR and Normal Operating Cell Temperature (NOCT) 44.43°C (±3.7%) PV-KST4/611-UR, MC4, Renhe 05-8 Temperature Coefficient of Pm -0.3610/o/'C Temperature Coefficient ofVoc -0.2625'o/°C MSE345SX5T• 345WP, 60 CELL SOLAR MODULE Temperature Coefficient ofl,c 0.039%/°C CURRENT - VOLTAGE CURVE Cells Temp.PERATING CONDITIONS u Incident Irrd. = 1000 W/mZ Maximum System Voltage 1,000Vdc 10 Incident Irrd-800 w/mz Operating Temperature Range -40°C (407) to +85°C (185°F) ¢.Ei 8 Maximum Series Fuse Rating 20A Incident Irrd. = e00 w/mz Fire Safety Classification Type 1 6 tj Incident Irrd.=a00 w/roz 5600 Pa front and 4800 Pa back load a ncident Front & Back Load (UL Standard) Irrd.=zoo W/mz Tested to UL 61730 z Hail Safety Impact Velocity 25mm at 23 m/s 0 o m m n m Voltage [V] Current -voltage characteristics with dependence on irradiance and module temperature BASIC DIMENSIONS (UNITS: mm) to5a----7 -1 r ao Front View Side View F_1054 01.0 Mounting Hole a8 . 05.5 Grounding Hole W) Front View Mission Solar Energy reserves the right to make specification changes without notice IEC 61215, 61730, 61701 UL 61730 cCDus -cC n�v LISTED suo Container FT Ship To Pallet Panels 345 W Bin 53' Most states 34 884 304.98 kW Double Stack California 28 728 251.16 kW Pallet [26 Panels] Weight Height Width Length 1263 lbs. 47.5 in 46 in 70.25 in (573 kg) (120.65 cm) (116.84 cm) (178.43 cm) Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235 www.missionsolar.com I info@missionsolar.com THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. `%IlkI...I.,�� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS\GENSF'9;<'''. DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 87479 �. SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = OF STATE OR\ON Enphase IQ 7 and IQ 7+ Microinverters with Integrated MC4 Connectors PRELIMINARY �'s`,9/0NA� INPUT DATA (DC) IQ7-60-M-US IQ7PLUS-72-M-US Commonly used module pairings' 235 W - 350 W + 235 W -440 W + J Module compatibility 60-cell PV modules only 60-cell /120-half-cell and 72- _ cell /144-half-cell PV modules 0 Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V m Operating range 16 V - 48 V 16 V - 60 V o Min/Max start voltage 22 V / 48 V 22 V / 60 V Y Max DC short circuit current (module Isc) 15 A 15 A w Overvoltage class DC port II II c=� DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; u-) AC side protection requires max 20A per branch circuit o OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter I I-_ Peak output power 250 VA 295 VA m 4 z N Maximum continuous output power 240 VA 290 VA m Nominal (L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / z w z 211-264 V 183-229 V 211-264 V 183-229 V L ¢ m Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) o N o Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms V J Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) - t Overvoltage class AC port III III L AC port backfeed current 18mA 18mA o Power factor setting 1.0 1.0 1-4 c 7 Power factor (adjustable) 0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging r EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 % 97.6 % 97.5 % 97.3 % J CEC weighted efficiency 97.0 % 96.5 % 97.0 % 96.5 % MECHANICAL DATA Z w � r) Ambient temperature range -400Cto+650C(400Fto+1490F)-400Cto+650C(400Fto+1490F) H :� I_ � Relative humidity range 4%to 100%(condensing) w O J I DC Connector type Staubli made MC4 W U = M Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) H j c� Weight 1.1 kg (2.4 Ibs) UI rl) Lo Cooling Natural convection - No fans Z a r ) W to Approved for wet locations Yes W w Pollution degree PD3 D O Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Or C1_ Environmental category/ UV ex osure rating NEMA Type 6 / outdoor H Z FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at httos://enohase.com/en-us/support/module- 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area Note: Adapters 1 and 2 are qualified per UL subject 9703, Adapter 3 requires installers to field install their choice of connector. > m To learn more about Enphase offerings, visit enphase.com o w NLLJ to /^� © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, v E N P H A S E o CD Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 30-MAR-2021 r O tr o U o Z O to ¢ z U N U L� �p U w J � cm W IZ U Cl-Q (n DWG. NO. S-5 Enphase Q Cable Accessories Q AGGREGATOR SPECIFICATIONS Q Aggregator Q-BA-3-1P-60 (single-phase). Combines up to three microinverter branches into one home run. Protect with maximum 60 A, 2-pole OCPD. Q Commercial Aggregator Q-BA-3-3P-35 (three-phase). Combines up to three, single-phase microinverter branches into a three- phase home run. Protect with maximum 40 A, 3-pole OCPD. Dimensions 190 mm (W) x 227 mm (D) x 80 mm (H) [7.5 in (W) x 9 in (D) x 3.2 in (H)] Homerun conductor size range #12 to #4 AWG Enclosure rating NEMA3 (up to 45" from horizontal) Temperature range -40" C to +55" C (-40° F to +122° F) Compliance UL1741 (assernbled product) and UL6703 (bulkhead connectors) CONDUCTOR SPECIFICATIONS Certification UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV resistant, combined UL for the United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulhead connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Model Number Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-200 300 meters of 12 AWG cable with no connectors Field-wireable connector (male) Q-CONN-10M Make connections from any Q Aggregator open connector Field-wireable connector (female) Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Aggregator sealing caps (male) Q-BA-CAP-10 Sealing cap for unused aggregator connections Q Cable sealing caps (female) Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) TERMINATOR nator for cable Termends, SEALING CAPS Sealingcaps aggregator sold packs ends, sold in packs often leconnr bons and cable connections (Q-TERM-10 (Q-BA-CAP-10 and Q-SEAL-10 DISCONNECT TOOL Plan to use at least oine per CABLE CLIP Used to fasten cabling to the racking installation, sold in packs often or to secure looped cabling, sold in (Q-DISC-10) packs often (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. ENPHASE 2018-01-03 `/ THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for integrated revenue grade PV X-IQ-AM1 240-3 production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect" CELLMODEM-03 (4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT Split core current transformers enable whole home consumption metering (+/- 2.5%). CT-200-SPLIT `Consumption monitoring is required for Enphase Storage Systems Ensemble Communications Kit Installed at the IQ Envoy. For communications with Enphase Encharge"" storage and Enphase CoMMS-KIT-01 Enpower" smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner" and allows wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole,10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole,15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the Enphase Enpower'" smart switch and the Enphase Encharge'" storage system XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64 A Max. total branch circuit breaker rating (input) 80 A of distributed generation / 95 A with IQ Envoy breaker included Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP /Eaton BR series included Production Metering CT 200 A solid core pre -installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 Ibs) Ambient temperature range -400 C to+460 C (-400 to 1150 F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS %% PEW 1) ""'0i .�%%!yq �'�• No 87479 STATE OF SS,O N A� ,E��` �. J 2 0 r m 0 `-) U U LO CD m N O N CN Z N o z c:.i z � ¢ m LiJ J Q N p v J J D7 r2 Z o O r, H cD F' o O J 0 Z w o � H g W W CD W U = � H Lr� U N Z N Z a in N" W z O H Z D Integrated WI-F! 802.111)/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular CELLMODEM-M1 4G based LTE-M cellular modem (not included). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 0 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) m Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 o O w H N J I o learn more aDout tnpnase offerings, visit enpn ise.com > CD CD © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the ENPHASE o 0 C) trademarks of Enphase Energy, Inc. Data subject to change. 2021-05-20 U d Cn O G.i � Z cn ¢.d- z 00O U U Lo L� w �O p U W DWG. NO. S-6 �►►1111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew_D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS P.<:\GENs�• << DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 87479 SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = � :• STATE OF Assembly �0RloP'��.' Ol ' • 1- oo 0 Corner out ik-,arrray on roof. r Snap chalk lines for rail o location within shingle Y U course. (Refer to module = manufacturer frame clamping zones). Mark mounting locations over rafters and chalk lines o I U H within shingle course. x x °O 04 4 z N Refer to engineering letters m for allowable mount spacing. 3 Q m CM CM N O For deck attachments, follow steps in 2a, but only use Splice Foot screws in the four corners of the mount. When possible always attach mounts to the rafter and only use deck attached as a secondary option when rafters are not within mounting zones for the array. Fallow K2 engineered calculations and span charts for deck attachments. J U When deck attaching check for positive engagement into plywood and avoid plywood seams. Z o O r> O Q O J 0 Q w O J lfi 1 START LU C' _ Using an additional piece of H r K2 butyl or a standard comp ,a rI Z � a M shingle starter course, level w N" out the roof surface under the w z Splice Foot. O= C'1 Cl- H For a video on mount leveling Z please refer to Splice Foot installation video: https:// www.youtube.com/c/ K2SystemsUSMX Locate the rafter and clean roofing surface for mount placement. Peel back protective paper from butyl, and stick down mount on a single shingle course with the two center holes lining up over the rafter. Position all mounts in the same direction with the long side towards the ridge. Drive provided lag screws into the rafter until the conical washer stops rotating, providing a positive seal. Do not over torque. J m O W N O H J n W m U Q O (_ � Of U Z 4 Gj N ¢ 0 O cn z U U Ln L Gj U w p p W U d FDWG. N0. S-7 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. `11/111111// y��,��' HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS ����•o�,Ew•D, .�' P.<:\GENs�• DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE •• No 87479 SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = STATE OF OR S4ONA11 1�``�`• J Sealant O application 0 Splicing two rails m e When connecting two rails to the Splice Foot, insert two T-Bolts through the Splice Foot slots and into side channel of CrossRail. Turn the T-Bolts clockwise ensuring that the mark at the end of the shaft is vertical, indicating proper alignment. Leave a 5/8" gap between rails in the center of the Splice Foot. Tighten to 25.8 ft- Ibs [35 Nm]. Note: Rail connector function for Splice Foot is only compatible with mill rail. 0 U o I C] N O CV NLjj Z N m Z O 3 �,..i z t Q U mp O 0 � Apply appropriate sealant to top and each side edge of mount, covering exposed butyl. No need to I Proper T-Bolt Alignment V � apply to the bottom of mount. If the mount falls on top of a shingle seam, fill and seal the seam with a Incorrect correct U) Refill patible roof sealant. If a seam comes within 2" of the lag screw, fill the seam with roof sealant. z o O C) H o D co O Q � CC Z W O H co W O J ALtaching single CrossRail LU zLn Ln Position and install rail on back side of Splice Foot towards the ridge, as shown in the image. Insert only one CD z cl- T-Bolt through one Splice Foot slot and into side channel of CrossRail. Turn the T-Bolt clockwise ensuring that w N the mark at the end of the shaft is vertical, indicating proper alignment. Tighten to 25.8 ft-Ibs [35 Nm]. W z o CI � H z .r ProperT-Bolt Alignment Incorrect Correct m o w Cn O H J r` W m (D CDU j >- O O d C/-) Z O LLJ O 6 Cn < 0 Q z O O w O p L'I J Q' M d U Cl- Q (n M. NO. S-8 `11/111111// THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ANDREW D. ����•o�,Ew•D, y�i,��� HALL, P.E. USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS P.<:\GENs< DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE No 87479 SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. = * = 0: STATE OF Mounting systems for solar technology solar Mwm o a Crossilail 48-X Technical Data Sheet 0 U Overview: U 0 U o I C] N O CV N Z N m \ z o w J z U p 0 0 v J J Z O o H o CO U O Q General Dimensions: Z w O � H CO W 39 [4216.401— H Ln z 1.54 166 Z LU W z O [48] 1.89 0 Dimensions in [mm] Inches Notes: ► Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 ► UL2703 Listed System for Fire and Bonding m N � O W <n p N W J ... Qoduct Wa > O Of CrossRail 48-�; Technical Data Sheet US1-0817 UL U o 0 De' Of o a � LISTED o w o 0 n < 0 cn z z it U W O p L'I J Q' M 0- a- U Q (n W. NO. S-9 MECHANICAL PROPERTIES Material: 6000 Series Aluminum Ultimate Tensile Strength: 37.7 ksi (260 MPa) Yield Strength: 34.8 ksi (240 MPa) Weight: 0.56 lbs./ft. (0.833 kg/m) Finish: Mill or Dark Anodized SECTION PROPERTIES Sx: 0.199 in3 (3.261 cm3) Sy: 0.153 in3 (2.507 cm3) A (X-Section): 0.467 in2 (3.013 cm2)