Loading...
HomeMy WebLinkAboutLetter - Wind Load Pressure CalculationMay 30, 2017 Project information: RECEIV'D JUN 1 � 2017 Islandia I 9550 S. Ocean Dr Jensen Beach, FL Suite # 608 To whom it may concern: 1 0�-'RANFAELD ■ ARCHITECTS ;b&3 N.c. J 5NStN DEACH 5GVD. J%55N 35ACrt, FLORIDA 34` 57 N IONE: 772-2,03-6032 i FAX: 772-253-6150 The following Wind Load Pressure Calculations have been performed at the aforementioned address utilizing the ASCE-7-10 (Part 4- Buildings with height of 15-80 ft) Components and Cladding pressure formulas and were performed at the request of the Contractor — Natural Flow. Building Information : Exposure D - Importance Factor #1 Height: 70 ft — 6t" Floor Wind Speed: 170 mph Minimum Required Opening Pressures: Openings that are 20 sgft to 50 : Zone 4 = +52.3 / -52.9 psf Zone 5 = +52.3 / -93.9 psf Openings that are 50 sgft to 100: Openings that are 100 sgft to 500: Zone 4 = +48.5 / -50.7 psf Zone 5 = +48.5 / -84.8 psf Zone 4 = +45.2 / -48.5 psf Zone 5 = +45.2 / -77.8 psf If there are any comments or concerns please contact me. Sincerely, Sf"va4 t- Grp Stewart Granfield Granfield' Architects PLLC stewart@granarch.comcastbiz.net 6, ON LA ON z 6-6h- A•