Loading...
HomeMy WebLinkAboutProject InformationRECEIVED JUN 12 2017 April 14, 2017 Project information: FILE COSY Owner: Henderson Islandia I 9550 S. Ocean Dr. Jensen Beach, FL Suite # 1205 To whom it may concern: (IRANVIELD ■ CHITECTS j653 N.E. JENSEN MAC-1 EGVE). DENS N 3E ACr% FLORIDA 34q 7 PHONE: 7 72-203-6�0+32 I The following Wind Load Pressure Calculations have been perfonned at the aforementioned address utilizing the ASCE-7-10 (Part 4= Buildings with height of 90-160 ft) Components and Cladding pressure formulas and were perfonned at the request of the Contractor — Natural Flow. Building Information : Exposure D - Importance Factor #1 Height: 140 ft —12t" Floor Wind Speed: 170 mph Minimum Required Opening Pressures: Openings that are 20 sgft or more : Zone 4 = -85.1 /+ 85.3 psf Zone 5 = -157 / + 85.3 psf Openings that are 50 sgft or more: Zone 4 = -80.7 / +81.2 psf Zone 5 = -149 / +81.2 psf Openings that are 100 sgft or more: Zone 4 = -77.2 / +77.7 psf Zone 5 = -142/ +77.7 psf If there are any comments or concerns please contact me. Sincerely, Sfe-wV4-f- G Stewart_Granfield Granfield Architkts PLLC stewart@granareh.comcastbiz.net c a -- ITrn m12IV