The following Wind Load Pressure Calculations have been perfonned at the aforementioned address
utilizing the ASCE-7-10 (Part 4= Buildings with height of 90-160 ft) Components and Cladding pressure
formulas and were perfonned at the request of the Contractor — Natural Flow.
Building Information : Exposure D - Importance Factor #1
Height: 140 ft —12t" Floor
Wind Speed: 170 mph
Minimum Required Opening Pressures:
Openings that are 20 sgft or more : Zone 4 = -85.1 /+ 85.3 psf
Zone 5 = -157 / + 85.3 psf
Openings that are 50 sgft or more: Zone 4 = -80.7 / +81.2 psf
Zone 5 = -149 / +81.2 psf
Openings that are 100 sgft or more: Zone 4 = -77.2 / +77.7 psf
Zone 5 = -142/ +77.7 psf