The following Wind Load Pressure Calculations have been performed at the aforementioned address
utilizing the ASCE-7-10 (Part 4- Buildings with height of 90-160. ft),Components and Cladding pressure
formulas and were performed at the request of the Contractor — Natural Flow.
Building Information : Exposure D - Importance Factor #1
Height:.160 ft —14"` Floor
Wind Speed: 170 mph
Minimum Required Opening Pressures:
Openings that are 20 sgft to 50 : Zone 4 - +60.4 / -61.1 psf
Zone 5 = +60.4 / 408.4 psf
Openings that are 50 sgft to 100: Zone 4 - +56.0 / -58.5 psf
Zone 5`= +56.0 / -97.9 psf
Openings that. are 100 sgft to. 500: Zone 4 = +52.1 / -56.0 psf
Zone 5 = +52.1 / -89.8 psf