May 30, 2017
Project information:
RECE1A'.-:D JUN 12 2017
Islandia I
9550 S. Ocean Dr.
Jensen Beach, FL
Suite # 1809
To whom it may concern:
i
rA
RANI`IEL. D ■.
CHI.TECTS
1683 N.E. YENSEN BEACH DLNP.
7EN5 �V EaGH, t Lt� it 34Q57
PHOPC
FAX: ?'r'?-2� 3 .50
FILE Copy'
The following Wind Load Pressure'Calculations have been performed at the aforementioned address
utilizing the ASCE-7-10 (Part 3 — Buildings greater than 60 ft) Components and Cladding pressure
formulas and were performed at the request of the Contractor Natural Flow.
Building Information : Exposure D - Importance Factor #1
Height: 210 ft —18t" Floor
Wind Speed: 170 mph
Minimum Required Opening Pressures:
Openings that are 20 sgft to 50 : Zone 4 = 64.7 / -64.7 psf
Zone 5 = 64.7 / -129.4 psf
Openings that are 50 sgft to 100: Zone 4 = 61.1 / -61.1 psf
Zone 5 = 61.1 / -115.1 psf
Openings that are 100 sgft to 500: Zone 4 = 57.5 / -57.5 psf
Zone 5 = 57.5 / -100.7 psf.
If there are any comments or concerns please. contact me.
Sincerely,
G r
StewazhCaanfield
arifield A,fchitects YLLC