Loading...
HomeMy WebLinkAboutLetter - Project Informationr May 30, 2017 Project information: RECE1A'.-:D JUN 12 2017 Islandia I 9550 S. Ocean Dr. Jensen Beach, FL Suite # 1809 To whom it may concern: i rA RANI`IEL. D ■. CHI.TECTS 1683 N.E. YENSEN BEACH DLNP. 7EN5 �V EaGH, t Lt� it 34Q57 PHOPC FAX: ?'r'?-2� 3 .50 FILE Copy' The following Wind Load Pressure'Calculations have been performed at the aforementioned address utilizing the ASCE-7-10 (Part 3 — Buildings greater than 60 ft) Components and Cladding pressure formulas and were performed at the request of the Contractor Natural Flow. Building Information : Exposure D - Importance Factor #1 Height: 210 ft —18t" Floor Wind Speed: 170 mph Minimum Required Opening Pressures: Openings that are 20 sgft to 50 : Zone 4 = 64.7 / -64.7 psf Zone 5 = 64.7 / -129.4 psf Openings that are 50 sgft to 100: Zone 4 = 61.1 / -61.1 psf Zone 5 = 61.1 / -115.1 psf Openings that are 100 sgft to 500: Zone 4 = 57.5 / -57.5 psf Zone 5 = 57.5 / -100.7 psf. If there are any comments or concerns please. contact me. Sincerely, G r StewazhCaanfield arifield A,fchitects YLLC stew`art@graiarcil:comcastbizanet 11�.•.c�99��r��, .'"i�;��'�,^-..ter TYPICAL FLOCR PLAN-* MECHANICAL .Zor-: = 5, O-At W6,.6h.- kuhns RECEIV i- , 0 JUN 1 FILE" I