The following Wind Load Pressure Calculations have been performed at the aforementioned address
utilizing the ASCE-7-10 (Part 3 — Buildings greater than 60 ft) Components and Cladding pressure
formulas and were perfonned at the request of the Contractor — Natural Flow.
Building Information: Exposure D - Importance Factor #1
Height:. 190 ft —16t" Floor
Wind Speed :.170 mph
Minimum Required Opening Pressures:.
Openings that are 20 sgft to 50 : Zone 4 = 63.5 / -63.5 psf
Zone 5 = 63.5 /-127.02 psf
Openings that are 50 sgft to'100,: ' Zone 4 = 60 / -60 psf
Zone 5 = 60 / -112.9 psf
Openings that are 100 sgft to 500: Zone,4 = 56.4 / -56.4 psf
Zone 5 = 56.4 / =98.8 psf