Loading...
HomeMy WebLinkAboutLetter - Project Informationa RECEIVED JU.N 12 2017 May 30, 2417 Project information: FILE C o Py Islandia I 9550 S. Ocean Dr. Jensen Beach, FL Suite # 1606 To whom it may concern: (2�0R;ANFIELD q . C"1.TECTS 1683 N.E. JENSEN E=AC; � N -Vr,. JENS�N BCAC R F�O,'R;CA 34'7,`; I �i ivNG: 17 L' 4 iJ �•' c.L% L `A& "rr-1`�^ )trC The following Wind Load Pressure Calculations have been performed at the aforementioned address utilizing the ASCE-7-10 (Part 3 — Buildings greater than 60 ft) Components and Cladding pressure formulas and were perfonned at the request of the Contractor — Natural Flow. Building Information: Exposure D - Importance Factor #1 Height:. 190 ft —16t" Floor Wind Speed :.170 mph Minimum Required Opening Pressures:. Openings that are 20 sgft to 50 : Zone 4 = 63.5 / -63.5 psf Zone 5 = 63.5 /-127.02 psf Openings that are 50 sgft to'100,: ' Zone 4 = 60 / -60 psf Zone 5 = 60 / -112.9 psf Openings that are 100 sgft to 500: Zone,4 = 56.4 / -56.4 psf Zone 5 = 56.4 / =98.8 psf If there are any comments .or concerns please contact me. Sincerely, Stewart Granfield Granfield Architects PLLC w z 6,Ah— kuhns 6 -y