Loading...
HomeMy WebLinkAboutRoof Information Sheet "EVVORKS . fit, ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET cF Florida Building Code 7th Edition (2020) 9,p iG�o Based on Section 1525 of the Florida Building Code-Buildingf� � G INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C %9A 4,5bi-7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A, B, D Concrete or Clay Tile A, B, D,E 1;2;34,5,6,T Metal Roofs A,B, D Wood Shingles and A,B, D 4;g,R7 Shakes Other As Applicable 9,2;34,5,B,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page. 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS,128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 �■ CIEWOR , Section A(General Information) Master Permit No. Process No. Contractors Name: Sunrise City CHDO Inc License# CM 327208 Job Address5600 PALEO PINES CIR, Fort Pierce FL 34951 ROOF CATEGORY r—ILow Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles Asphaltic Shingles Metal Panel/Shingles Mood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE 13 New roof ❑ Repair ❑ Maintenance n Reroofing ❑Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) 0 Steep Sloped Roof Area(SF) 3,447 Total(SF) 3,447 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. ti, .� .._. .. ._.. .. NYSE 20, P pi .4 t ction C(Low Slope Roof) Surfacing: Fil specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Atta ment: man cturer Zone 1':—"oc @ Lap,#Rows (If a co onent is not used,identify as"NA") Zone 1:—" oc @ Lap,#Rows ',ac System M ufacturer: Zone 2:—." oc @ Lap,#Rows ' Product Appro I No.: Zone 3:—." oc @ Lap,#Row Number of Fasteners Per Insu tion Board: Design Wind Pressu ,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Zone 1':—Zone 1: Zone 2: Zone 3: Illustrate Components oted and Details as Applicable: Max. Design Pressure,fro the specific product approval Woodblocking, G er, Edge Termination, Stripping, system: Flashing, Contin us Cleat, Cant Strip, Base Flashing, Counterflashin oping, Etc., Deck: Indicate: Me Roof Height, Parapet Height, Height of Base Type: Flashing,C ponent Material,Material'Thickness,Fastener Gauge Thickness: Type,Fas ner Spacing or Submit Manufacturers Details that Compl ith RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding Materi Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding M erial: Height Ply Sheet(s)'&No.of Ply(s Ply Sheet Fastener/Bon ng Material: Top Ply: Top Ply Fast e er/Bonding Material: I V Section D (Steep Slope Roof System) Roof System Manufacturer: Architectural Shingles Notice of Acceptance Number: FL17796 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): ,Zone 1: 47•8 Zone 2e:-47.8 Zone 2n:'76•0 Zone 2r:-76* Zone 3e±!: Zone 3r: LL DeckTYPe. Plywood Type Vnderta�menf. Peel N Stick :Roof Slope; 4 � Iriso a of: None Fire Bamer ; None . RcdgeUentda>aon7'yes FastenerTyge Spacing, 2 1/2" Ring Shank 410C. . Adhesive T Ype , TypeCap Sheet: N/A Mean Roof Height 1�. Roof Covering;' Shingles. Type&size Dnp:' 3"x 3"Aluminum Ed , ge: NJLUC 1K. Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for/Mf- Method the values fro Mr.If the Mf values e greater than or equal to the Mrvalues,for each area of the roof,then the tile att method is ceptable. Method 1'Moment Based Tile Calculations Per RA (Zone 1: �� _ _�..Mg; - Product l M (Zone 2e: Product lMr (Zone 2n- x� _) �t1g = Product al (Zone 2r: x•k = _)-Mg M�, Product l f one 3e: x�, _�-.Mg =M ProductIMf ( ne 3r: x x = ._ -` 9� ^Mrar . Product l Mf- - - --.-- Method 2"Simplified Tile Calculations Per Table B Required Moment of esistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof lope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 .4 28.0 29 4 30.5 32.4 7:12 24. 25.9 .1 28.2 30.0 *Must be used in conjunction with a list oXae based tile sy ems For Uplift based the systems use Methore the valu s for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of th the tile ttachment method is acceptable. Meth Base Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) cos =Fr1 Product Approval F' (Zone 2e: x L =x W:= ) s r =Fr2e Product Approval F',(Zone 2n: x L =x W:= ) c r =Frzn Product Approval F'.(Zone 2r: x L =x W:= ) cos =Fr2r Product Approval F' (Zone 3e: x L =x W:= ) cos r =Fr3eProduct Approval F' (Zone 3r: x L =x W:= ) cos r =Fr3r Product Approval F' Where to obtain Infor ation Description Symbol Where to find Design Pressure Zo es 1,2e,2n,2r,3e,3r From apple ble table in RAS 127 or by an engineering analysis prepared by based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravi Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resista a Mg Calculated Minimum Attachment sistance F' Product Approval Required Uplift Resis nce Fr Calculated Average Tile Weig W Product Approval Tile Dimensions L=length W=width Product Approval All calculatio must be submitted to the building official at the time of permit application.