Loading...
HomeMy WebLinkAboutCertification For Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: S'fnNV4Q� ?nCIFIG HOMC5 - 3-Iy?2Se9D Project Address: 3058 NlJ l A'P -IFr-r LJA4 - &vr 16 Permit #: Occupancy Type: 'V-• 3 Construction Type: V13 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) - o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida SOi Lbtoc% Code Fifth Edition with 20 I� _Supplements using ASCE 7-10 2. Structure Designed as (check one): YEnclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B )L_C D 4. Design Wind Velocity t ^1C mph X ASD LRFD End Zone Width: 16'-V ft 5. Mean Roof Height ZD -U ft Roof Pitch: 1 :12 Parapet: J.11 �_ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: - 3 6 Zone 2: - b Z Zone 3: - 9 k Zone 4:- �,_ Zone 5: - 4 � Garage: - 4 2 7. Design Loads: Floor: /A PSF Roof/Dead: `silo PSF Roof/Live: wllo Balcony: lJJA PSF Dock: j11 PSF Deck: IJIA PSF Stairs: NIA PSF Fence: n%JA PSF Railings: A11A PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? x Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: ?-5 'DO PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I als 1 that structural elements depicted on these plans provide adequate resistance to the design forces �.�d���// 1N 0�.�ERN4i. VIUT07j NeZNAtvPEZ ` -C'. #'►L3b'7 ' % print Name Cert # & Co. Cert Auth. E ,MP eal ;� N ;ORIOP.••6R0 ►iibAL E� ���� %-%L6wari6J 6t4('. I t4c . W00 5• 2909 HWI StI5 400 30tq "NON. f1, Company Name & Address 33 4 3 Z