Loading...
HomeMy WebLinkAboutProduct Approval Roof TileFlorida Building Code Online Page 1 of 2 aCIS Home t Log In User Registration Hot Topics Submit Surcharge I 'Stats & Facts E Publications 1I� IProdct Approval r l MF- USER:Public User Product Approval EIM > Product or Anplicatlon Search > Application List > Application Detail 01 FL # FL17326-RI Application Type Revision Code Version 2614 Application Status Approved Comments Arehlved i 1; FBC Staff BCIS Site Map ' L Product Manufacturer EAGLE ROOFING PRODUCTS FLORIDA LLC Address/Phone/Email 1575 East CR 470 Suritervllle, FL 33858 (000)400-3245 arineite 6e, agl " .corn Authorized Signature Annette Sind annettes@eagleron a Technical Representative Annette Sindar Address/Phone/Email 3546 N. Riverside Ave Rialto, CA 92377 (800) 400-3245 annettes@eagleroofing.com Quality Assurance Representative Address/Phone/Small Category Roofing Subcategory Roofing Tiles Compllance Method Evaluation Report from a Florida Registered Architect or.a Licen Professional Engineer �. Evaluat'ion'Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License. PE-74021 quality, Assurance Entity Architectural Testing, Inc. Quality Assurance Contract Expiration Date 12/31/2018 Validated By Locke Bowden Certificate of Independence ntia 0F. efre{r�elfn�.p��aiSfc�ard and Year (of Standard) Ff51Ef1 •�`'Yorr� Pd. �q• f,Yry,$�'o v Validation Checklist- F ?rdcopy Received FL17326 R1 COX Eagle Evaluation Rencit FINAL for hvbrid Insi Caolgrano Malibu -and Bel•Air.pdf Standard ASTM C 1492 7A5100 TAS 10 TAS 102 TAS 112 ,, Zoe 9; ,ga tiq�oavu°-' https:/lfloridabuilding.org/pr/pr^app_dtl:aspx?param=wGEVXQwtDgsRyNw... Year 2003 1995 1995 1995 1995 2/2/2017 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method .Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products Method 1 Option D 06/08/2015 07/10/2015 07/18/2015 08/20/2015 12/14/2016 FL # Model, Mummer or Name Description 17326.1 Capistrano, Malibu and Bel Air Eagle Hybrid Installation Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See Evaluation Report for limitations of use. Installation Instructions FL17326 RI II Eagle Evaluation Report FINAL for 1 installation of Capistrano Malibu and Bel Air pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL17326 RI AE Eagle Evaluation Report FINAL for installation of Capistrano Malibu and Bel Air.ndf Created by Independent Third Party: Yes 17326.2 Capistrano, Malibu and Bel Air Eagle Hybrid Installation Limits of Use Approv or use in HVHZ: Yes roved for use outside HVHZ: Yes Impact Resistant: N/A Design pressure: N/A Other: _ Installation Instructions FL17326 Rl II ERP14001.1 2014 Evaluation for ht installation of Capistrano Malibu and Bel Air.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Yes Evaluation Reports FL17326 RI AE ERP14001.1 2014 Evaluation for h installation of Capistranq Malibu and Bel Air.pdf Created by Independent Third Party.: Yes _ Sack RJext Contact Us :: 2601 Blair Stone Road. Tallahassee FI, 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refun Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records reques electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.13E Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department H address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public n not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To de are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a'°cvrr... F99M! Credit Card Safe https://floridabuilding-org/pr/pr app dtl.aspx?param=wGEVXQwtDgsRyNw... 2/2/2017 %��ZA R F. LM-:� K Tl F-CCh-llNDCAL SF.RVItC F-S, LLC EVALUA710M REPORT Manufacturer: Manufacturing Plants: Quality Assurance: SCOPE Category: Subcategory: Code Sections: Properties: PRODUCT DESCRIPTION Capistrano Profile: Description: Dimensions: Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 EAGLE ROOFING PRODUCTS FLORIDA LLC 1575 E CR 478 Sumterville; FL 33585 (800) 400-4235 httD://www.eagleroofing com Sumterville, FL Architectural Testing, Inc. (QUA1844) 2010 FLORIDA BUILDING CODE Issued October 23, 2014 Roofing Roofing Tiles 1507.3.5, 1507.3.7, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift Resistance ASTM C 1492, TAS 112, high profile, concrete roof tile TAS 112 type la, high profile, interlocking class III concrete the 17.0" x 12.25" x 3.0" at�ir,f,�a[i Figure .9. Capistrano ERP14001 FL17326 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL. SERVICES. I_L.0 EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano, Malibu and Bel Air Concrete Roof Tiles Dgtg for Attachment Calculations Nominal Weight (W) and Aerodynamic Restoring Moments due to Gravity - M9 (ft-lbf) -rile Dimensions (I x w) Multipliers ; Direct Deck Roof W (Ibf) L (ft) W(ft) Direct Deck 3":12" 4':12" 5"t12" 6":12" >7":12" - Application Capistrano 9.7 1.42 1.02 0.30 6.83 6.75 6.65 6.52 6.38 Malibu 9.2 1.42 1.03 0.31 6.47 6.37 6.24 6.09 5.93 Bel Air 11.8 1.42 1.03 0.29 8.27 8.15 1 8.00 1 7.81 1 7.61 Atachelr➢elro Resistance Expr6ssed as a Moment Hybrid installation system;i _ Fasteners Adhesive Mf (ft Ibf) Roof Tile Paddy Padd Type Count Size Adhesive Size Weight2 Capistrano Screw 2 #8 Dow 'm BOND 6"x1"x1" 13.7g 47 Malibu Screw 2 #8 Dow TILE T. BOND 6"x1"x1" 10.4g 73 Bel Air . Screw 1 2 #8 TILE Dow BOND- 6"x1"x1" 10.4g 66 Notes: 1) Simpson Strong -I ie QUM unve vvSuu Koor i ue Screw snau oe nun. a-mcn wall suwuGuL 1o11yu1 w the plywood deck a min. 1/2-inch 2) Minimum dimensions and weight for adhesive application LABELING 1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows: r ERP14001 FL17326 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not . specifically addressed herein. CREEK TECHNICAL SERVICES, I_LC LIMITATIONS 1 2) 3) 4) EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano, Malibu and Bel Air Concrete Roof Tiles Fire Classification is not within the scope of this evaluation. Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI 07320/8-05, and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 118. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below). 50 WEATHERING REGIONS I:_:_7J M-NEGLIGIBLE WEATHERING MODERATE WEATHERING GrilSEVERE WEATHERING REFERENCES Eniiiy Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0610.01-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.01-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (TST3782) RT0610.02-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.02-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (17ST3782) RT0610.03-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.03-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (TST3782) RT0603.01-13 TAS 101/TAS 102 1995 PRI Construction Materials Technologies ERPF-057-02-01 TAS 101/TAS 102 1995 PRI Construction Materials Technologies ERPF-058-02-01 TAS 101/TAS 102 1995. PRI Construction Materials Technologies ERPF-059-02-01 TAS 100 1995 PRI Construction Materials Technologies ERPF-060-02-01 TAS 100 1905 PRI Construction Materials Technologies ERPF-061-02-01 TAS 100 1995 ERP14001 FL17326 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano, Malibu and Be[ Air Concrete Roof Tiles The .products evaluated herein by Zachary. R Priest P.E. have demonstrated. compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. e G�P ° ZF°��✓ E NSF 0 No 74021 a o* o o� STATE OF °' 'JJ10 0 e ,ce�ORlOp°�\�Omc im g� N Aa D CERTIFICATION OF [INDEPENDENCE 2014.10°23 / ihP' 16:22:42 —04"00° Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ERP14001 FL17326 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 Al-10REEK 17520 Edinburgh Dr Tampa, FL 33647 TEcHNICC:AL, SF-Rvicm, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE V EDITION (2014) Manufacturer: EAGLE ROOFING PRODUCTS FLORIDA LLC Issued July 6, 2015 1575 E CR 478 Sumterville, FL 33585 (800) 400-4235 hftp:/Awm.eagleroofing.com Manufacturing Plants: Sumterville, FL Quality Assurance: Architectural Testing, Inc. (QUA1844) SCOPE Category: Roofing Subcategory: Roofing Tiles Code Sections: 1507.3.5, 1507.3.7, 1523.6.5.2, 1523.6.5.2.2, 1523.6.5.2.3 Properties: Physical Properties, Attachment Requirements, Wind Driven Rain, Static Uplift Resistance PRODUCT DESCRIPTION Capistrano Profile: ASTM C 1492, TAS 112, high profile, concrete roof tile Description: TAS 112 type la, high profile, interlocking class III concrete file Dimensions: 17.0" x 12.25" x 3.0" RAIL MY1110i i ,%I:`'Y - Figure 1. Capistrano ERP14001.1 FL17326-RI Page 1 of 6 This evaluation report is, provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. EAGLE ROOFING PRODUCTS FLORIDA LLC CREEK Capistrano, Malibu and Bel Air Concrete Roof Tiles I s TF-cHNICAL SIERWCES, LLC Malibu Profile: ASTM C 1492, TAS 112, medium profile, concrete roof tile Description: TAS 112 type 1 b, low profile, interlocking class III concrete tile Dimensions:17.0" x 12.375" x 2.125" NAX Bel Air Figure 2. Malibu Profile: ASTM C 1492, TAS 112, flat profile, concrete roof tile ®scrip ion: TAS 112 type 3a, flat profile, interlocking class 111 concrete tile Dimensions: 17.0" x 12.375" x 1.25" Figure 3. Bel Air ERP14001.1 FL17326-R1 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality -assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,, recommended use, or other product attributes that are not specifically addressed herein. `- CREEK TECHNICAL LAICAL SE.RViCEs. LLC APPLICATION METHOD EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano,' -Malibu and Bel Air Concrete Roof Tiles laagle MybVid Onstallatiion for Ca Iistvano, Malibu-, -and Bi�i Air Coracre$e 6�0Of THE Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSAITRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised or RAS 118. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min_ 19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment Underlayment: shall be Hot Mop 30/90 installed as described in RAS 118 Section 3.01. A minimum 6-inch x1-inch x 1-inch paddy of Dow TILE BONDTm shall be placed within the 3-inch head lap as shown in, Figure 4 thru Figure 6. The upper the shall be set immediately into the adhesive paddy. All tiles 'shall be secured by two (2) #8 x min. 3-inch Simpson Strong -Tie Quik Drive WSCD Roof Tile Screws with sufficient length to penetrate Attachment: through the plywood deck a minimum 1/2-inch and located into the factory located fastener holes. All penetrations in the underlayment shall be sealed in accordance with RAS 118 (HVHZ) and FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised (non-HVHZ). Figure 4. Adhesive Paddy Location for Capistrano Figure 6. Location of adhesive paddy Figure S. Adhesive Paddy Location for Malibu Location of adhesive paddy hesive Paddy Location for Bel Air ERP14001.1 FL17326 R1 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G2073. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano, Malibu and Bel Air Concrete Roof Tiles Data f®P Attachment Ca lcul.00ns Aerodynamic Restoring Moments due to Gravity,- M9 (ff=lbf) Nominal Weight .(M and Multipliers Dimensions .(I x w) Direct Deck Roof Tile W (lbf) L (ft) w (TO Direct Deck • 3":12. 4`12" 5":12" 6":12" >7"AT' Application Capistrano 9.7 1.42 1.02 0.30 6.83 6.75 6.65 6.52 6.38 Malibu 9.2 1.42 1.03 0.31 6.47 6.37 6.24 6.09 5.93 Bel Air 11.8 1.42 1.03 0.29 8.27 8.15 8.00 7.81 7.61 1� i�GG9QVIQ'$➢t ��S9S�911C 3i�E+ S��,® as a Wi®Pfl ent I-Iybrid.installation system; Fastener' Adhesive Mr (ft-Ibf) Roof Tile Pad d Paddy Type Count Size Adhesive;: Size WeigW Capistrano Screw 2 #8 Dow TILE BOND''"' 6"x1"x1" 13.7g 47 Malibu 1 Screw 2 #8 Dow TITM BOND 6"x1 "x1" 10.4g 73 Bel Air Screw 2 #8 Dow TILE BONDrm 6"x1 "x1" 10.4g 66 trate throu � Notes: 1) Simpson Strong -Tie Quik Drive WSCD Roof Tile Screw shall be min. 3-inch with sufficienI tt ength o pene g the plywood deck a min. 1/2-inch 2) Minimum dimensions and weight for adhesive application LABELING 1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows: FLORIDA ERP14001.1 FL17326-R1 . Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. EAGLE ROOFING PRODUCTS FLORIDA LLC CREEKCapistrano, Malibu and Be] Air Concrete Roof Tiles TECHNICAL SF—RviCicS, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSAITRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 118. 3) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 4) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of 50 or greater as illustrated in ASTM C 1492-03, figure 1 (see below). 0. 50 50" 50 1 WEATHERING REGIONS NEGLIGIBLE WEATHERING MODERATE WEATHERING L .. •tc; SEVERE WEATHERING PcccoGalrl=c Enti Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0610.01-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.01-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (TST3782) RT0610.02-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.02-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (TST3782) RT0610.03-14 TAS 112 1995 American Test Lab of South Florida Inc (TST3782) RT0610.03-14 ASTM C 1492 2003 American Test Lab of South Florida Inc (TST3782) RT0603.01-13 TAS 1011TAS 102 1995 PRI Construction Materials Technologies ERPF-057-02-01 TAS 101/TAS 102 1995 PRI Construction Materials Technologies ERPF-058-02-01 TAS 101/fAS 102 1995 PRI Construction Materials Technologies ERPF-059-02-01 TAS 100 1995 PRI Construction Materials Technologies ERPF-060-02-01 TAS 100 1995 PRI Construction Materials Technologies ERPF-061-02-01 TAS 100 1995 ERP14001.1 FL17326-R1 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SEi?vICEi, lI .I_C COMPLIANCE STATEMENT EAGLE ROOFING PRODUCTS FLORIDA LLC Capistrano, Malibu and Be] Air Concrete Roof Tiles The products evaluated herein .by Zachary R Priest P.E. have demonstrated compliance with the Florida Building Code 5t' Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer. °atttBED Dsjogt o�°°°° CRY R. • p ago®` No 74021 o a � o 13 STATE OF �ccl m c ems• <p• � ORt0® �*C�Oo CERTIFICATION OF INDEPENDENCE 011�05�7°01� 16®0®o07 ®4"®®9 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ERP14001.1 FL17326-R1 Page 6 of 6 'This evaluation report is provided far State of Florida. product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.