Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval Swinging Exterior Door
Florida Building Code Online Page 1 of 4 • BCIS Home I 'Log In User Registration I Hot Topics ( Submit Surcharge Stats & Facts Publications ; FBC Staff BCIS Site Map I Links Search a Product Approval ERubl(c User dbpr Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL7630-R6 Revision 2014 Approved v Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Rick Wright rickw@rwbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 9Z Evaluation Report - Hardcopy Received Lyndon F. Schmidt, P.E. PE-43409 National Accreditation and Management Institute 12/31/2018 Ryan J. King, P.E. © Validation Checklist - Hardcopy Received FL7630 R6 COI CERTIFICATE OF INDEPENDENCE.Ddf Standard Year AAMA/WDMA/101/I.S.2/A440-OS 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 hqs://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsrGs9vbZHHs... 3/15/2017 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 06/13/2015 Date Validated 06/28/2015 Date Pending FBC Approval 07/05/2015 Date Approved 08/18/2015 Summary of Products FL # Model, Number or Name Description 7630.1 a. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door - Inswing or "ClassicCraft" and "ClassicCraft Outswing configuration (X) Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II INST 7630.1.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant., Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.1 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.1.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 7630.2 b. "FiberClassic", "SmoothStar", "ClassicCraft" and "ClassicCraft Rustic" 8'0 "Impact" Glazed Fiberglass Single Door with sidelite - Inswing or Outswing configuration (OX or XO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II Inst 7630.2.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.2 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.2.1)df additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sideiites, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of Installation.) 7630.3 c. "FiberClassic", "SmoothStar", 18'0 "Impact" Glazed Fiberglass Single Door with sidelites - "ClassicCraft" and "ClassicCraft Inswing or Outswing configuration (OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II Inst 7630.3.0f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.3 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.3.1)df additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "J" part numbers for these doors and sideiites, which have been stained or painted within six months of installation.) 7630.4 d. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door - Inswing or "ClassicCraft" and "ClassicCraft Outswing configuration (XX) Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II INST 7630.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.4 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.4.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors, this product approval requires the use of "I" part numbers for these doors, which have been stained or painted within six months of installation.) 7630.5 e. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door with sideiites - "ClassicCraft" and "ClassicCraft Inswing or Outswing configuration (OXXO) Rustic" Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL7630 R6 II Inst 7630.5.odf Verified By: Lyndon F. Schmidt, P.E. 43409 https ://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsrGs9vbZHHs... 3/ 15/2017 Florida Building Code Online Page 3 of 4 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.5 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.5.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.) 7630.E f, "FlberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door utilizing Hoppe "ClassicCraft" or "ClassicCraft Multi Point lock - Inswing or Outswing configuration (X) Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II INST 7630.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.6 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.6.pdf additional use limitations, Installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 7630.7 g. "FiberClassic", "SmoothStar", "ClassicCraft" or "ClassicCraft 8'0 "Impact" Glazed Fiberglass Single Door with sidelite utilizing Hoppe Multi Point lock - Inswing or Outswing Rustic" configuration (OX or XO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II Inst 7630.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.7 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.7.odf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FlberClassic and SmoothStar doors and sidelltes, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.) 7630.8 h. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Single Door with sidelltes "ClassicCraft" or "ClassicCraft utilizing Hoppe Multi Point lock - Inswing or Outswing Rustic" configuration (OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II Inst 7630,8.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes_ Design Pressure: N/A Evaluation Reports Other: See INST 7630.8 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.8.Ddf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors and sidelites, this product approval requires the use of "J" part numbers for these doors and sidelites, which have been stained or painted within six months of installation.) 7630.9 I. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door utilizing Hoppe "ClassicCraft" or "ClassicCraft Multi Point lock - Inswing or Outswing configuration (XX) Rustic" Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II INST 7630.9.1)df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.9 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.9.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors, this product approval requires the use of'7" part numbers for these doors, which have been stained or painted within six months of installation.) 7630.10 j. "FiberClassic", "SmoothStar", 8'0 "Impact" Glazed Fiberglass Double Door with sidelites "ClassicCraft" or "ClassicCraft utilizing Hoppe Multi Point lock - Inswing or Outswing Rustic" configuration (OXXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7630 R6 II Inst 7630.10.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 7630.10 for Design Pressure Ratings, any FL7630 R6 AE EVAL 7630.10.pdf additional use limitations, installation instructions and Created by Independent Third Party: Yes product particulars. (For FiberClassic and SmoothStar doors https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsrGs9vbZHHs... 3/ 15/2017 THERMA.!,,.TRU 0 . e ■' E P,M A T P UFO D® DP S 1'I.ElANDUSTRIAL DR.,'EDGERTON. ❑H •43517 "SMOOTH STAR", "FIBER CLASSIC"; "CLASSIC • CRAM . "CLASSIC CRAFT RUSTIC►► GLAZED FIBERGLASS DOUBLE DOOR* wl SIDELITES INSWINdj OUTSWING ,,im c r GENERAL NOTES 1. This product hasbeenevatuatedand isincompfionceWith the•5thEdfBon(2014). Florida Bulding Code (FBCJ structuralrequYemenis excluding the'Hlgh Velocity Hurrfcon e Zone" (HVHZ). 2: ProducfanaHorsstio0beasCafedandspacedasahgwnon'detoJs.Anchorembedment'fobase o maferialshalibebeyond wdlidressingorstucco. � z 3. When: used In areas requiring windbomedebrbprotectionIhis.productcomplies wfthSection d 1609.1.2'ofthe FBCand does. hot regoke`animpact resistant cdvedng.Thisproductmsets mme d tevel"D`' includes WindZone and 4 as defined in ASTM E 1996 and:Section 1609.1.2.2 of the FBC � o: 4. For2x.stud ftairiing.construction; anchoring ofthese unitsshollbe the some as that shown for2x S N a buck masonry construction. P 5. Site. con d4lons.that deviate from the detalls of this drawing require further engineering analysis by d Gcetsdd eIigineerarregisfefed architect: TABLE OF CONTENTS SHEET# DFSCR1PT10N 1 TyptcoI elsvallons,:design pressures & general notes .2: Smooth` Star doorlsidePte panel&glcdhgdebabls 3 Fiber.Ctasslc'door/sidle fe panel &glaangdetaift 4 CfaSdCCraft/ClasSic craftRusticdoorlsldefrtepan el>adng.details 5 Homontolerdsssections 4 ?, 6 1 VedicafcrbsssecBorz 7 1 Vertical crosssections 8 Buck anchoring 9 Frameonchortng-'2Xbuckmasonryconsfnrclion 10 fromewchoring,IXbuck mosonryconstrucfton ' 11, Components 12 BlllofMalerfals:• Vpl ic =Usurt Q �` 151.FMAX FRAME WIDTH 74S6"MAXFRAMEWIDTH 36.00 MAX 3d75'MAX PANEL WIDTH---�-•-- PANEL WIDTH W/ASTRAGAL 37.ffMAX � -- FRAME WIDTH I (SIDEIffE) O X� e x oas"—IF--—It—oas+ "SMOOTH STAR", "BUR CLASSIC - "CLASSIC CRAFT".& "CLASSIC CRAFT RUSTIC" Y`a OVERALL FRAME DIMENSION_ _ '. OVERALL = DLO •DOOR /SIDEL1fE ._-.':`DfMENSION DESIGN PRESSURE (PSU =' ' 'POSIif ,E."'NEGATfVE•? tj41SWING 151.50" X 98.00" 21.00" x 78.75" +50.0 -50.0 OUTSWING, 151.50"X96.75" 21.00'.'X78.75' +50.0 -50.0 • dam'• m ri co: $•• rg 5m'� o� 4 M ia'ai 0 cui By, at_ BY. LFS NINO 11W FL-7830:5 Ir _L W 1e THERMANTRU THE:RmA TRU DMORS 1 16 INDUSTRIAL DR., EDGERTON, OH 43577 "SMOOTH STAR" "FIBER CLASSIC, "CLASSIC CRAFT' & "CLASSIC CRAFT RUSTIC" GLAZED-PBERGLASS'DOUBLE DOOR INSWING IE"F1� /�'qO 11i�S WIN G ndfY�cp� GENERAL NOTES 1. This producthas beep e4aludted and is in.compiibnce with the Sth Edition )2014) Roado Butitung Cade.(FBCysiructurai requiremenfs exciuding the•"Mgh Velocity'Hurdcana Zone" (HVHZ). ti 2. PredUct;anchors ftli be as listed and spaced as shown on details: Anchorembedmeni to base material shall be beyond Wall dressing or stucco. 3: When used in areas requiring wind borne debrls protection this productcompriesvwith Section 1609.12 of the FBC and does not require an Impact resistant covering. This product meets missile level"D 4 a "•and includes'Wind Zone s defined in ASTM E 1'996 and section 1609.1.2.2 of. the FBC. 4. For 2KStL1d-fkJml69:cbnstnJdffbn,. anctioring of these units shall be the some -as that shown foe 2c buck masonry construction: 5 Site conditions iRat.deviate from the details of this drowing requilre further engineering analysis by a llcensedengineerorregistered architect. TABLEOFCONIENTS- 'SHEETPv DESCRIPTION , 1 Typical elevations: design pressures & general notes. 2 Smooth Star door ponel&.giaangdetaUs 3 Fiber Ciasslcdoorponel&:glozlng:tletoSs 4 ClaisicCrafUClasslcCmRRUsfcdoorpanel&glozingdota� f - is S Honzontol crosssections. 6 Vedicalcrosssections 7 Buck&frameanrhor(pg-27(buckmosonrycorutruction• B Sanrycorltthrctiort > 'rt'. % 9 eomeanctionng•-1X=K-M ComponentS .�' 10 BIBot:Mbterlols MAT MAX.FRAME WI6TH 36.00'.MAX. 36.75' MAX: pANELWIDTH—rPANEL•WIDTH W/ ASTRAGAL T— = ip' o. i x O x O "SMOOTH STAR'.; "FIBER CLASSIC" CLASSIC CRAFT & ".CLASSIC CRAFT RUMC" i a re �$1 �l��•'•'•... . •• • J j Oml ♦♦♦ N PV ,oil I UN•• ( MEN vc [9xy°< 9moa a 2 LC in iL Ec �Z 3 b x w ' x -•,_, ' OV�E Y D�,STGN PkESSiIkE (PSFJ` .SWING { dU �D �O J v� _�A•r. _ i.•_ ,-DIl4f�NS10N D1h1Ef1lS10N,,, POSFIi]/E, 1VEG7}11VE•• INSWING 74.62" u 98.00" 21.00" x 78.79" +50.0 ;50.0 OUTSWING 74.62"x96.75" 21.00"x78.7S' +50.0 FL-7630.4 cr t OF 1f r A g i�H!n 1 16 INDUSTRIAL DR.. EDGERTON, OH 4351 7 "'SMOOTH STAR", "GIBER CLASSICIF °°CLASSIC CRAFT'° & "'CLASSIC CRAFT RUSTICBP GLi4ZED PIOERGLASS SINGLE DOOR WSWING/ O/U�'T7SWING y� GENERRL NOTES 1. This product hos been evaluated and is in.ccmpGancevAth the 5th Edtion 12014). Florida Building Codell`k)structural requirements excluding the"High Velocity Hurricane Zone, (HVHZ). 2 .Product anchoisshclf be as Wed and spaced as shown on details. Anchor embedment to base material shall be:beyond wall dressing or stucco. 3. When used in areas requidng wind bome debris'protection this product complieswhh Section 1609:129f the FBG and does notrequire on impact resistant covering. This product meets missile level T- and includes Wind Zone 4 as defined inASTM E 1996 and Section 1607.1.2.2 of the FBC. 4. For2K slud framing cordiructioa,•anchoring of these units shall be the some cs that shown for 2x buck masonry. construction. S. Site conci t ns that deviate -from-the details of this drowing.require further engineering analysis by a licensed endineerorregittered arctiitect. TABLE OF CONfENIS SHEENS I DESCRIP0014 1' I Typical elevations, design, resoles•&generafnotes 2 SmaothStardoorpanel&.gkrangdetolls 3 1Flberpasscdoorpgneb&gloangdetoSs -aV ` 4 Classic Cron/Classic•CraH Ruslic' oorpanel & glaring deetals „c 5. I Hoftntol CrossSeCilorLi 7- Vertical cross sections, 7 3uckandfromwanchoring-2X.buckmaronry construction 8 flame anchoring-1Xbuck masonry construction 9 Components a 10 '1311.01motedois 37.75" MAX. FRAME WIDTH 36.W MAX. PANEL'WIDTH 7 W = $ P O it "SM007H STAR'; "FIBER CLASSIC" "CLASSIC CRAFT' g "CLASSIC CRAFT RUSTIC" OVERALL OVERALL DESIGN PRESSURE (p5F], �StrJ1NG., 41� U►MEH510i� n, •pJ7}4EAISION, g POSf11VE NEGAiaVE•_ +$0.O INSWING; 37.75"k98.00" 21600P x 78.76' %OUTSWING 37.75" x 96.75" 21.00"•x 7815" +50.0 -50.0 FL-7630.1 .r 1 of T( d •