Loading...
HomeMy WebLinkAboutEngineering Package3 . i Builder: Project: Model/Building: Lot Alt: ENGINEERING PACKAGE [PR_HORTON _/ STATEWIDE _ _I 17A5/320 CREEKSIDE 182ED,F 02G Lot: 100 Address: .............................. JobNumber: N334504 Revision Date: unit: Reviewed for Codei Compll C Universal Engineering Sciences FILE COPY New Load #: R101 CARPENTER CONTRACTORS OF AMERICA, INC 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 A,PfNEMara 13,2010 ARnW6bA4Y Mt. Bob. Michaelis. Garp&fttdr.C6.ritradtofs of Am6ribk-lric. 3909 Avenue G, N.ofthweqt Writer HaVen, 5L 33880-6201 Re: Alternative instaltabofis.for a single ply aimed trCl,§s with a Width less than the, hangqr width, valid wood. blocking to -achieve full design load valUefcwihb@:- upted.'hanger-Aftachmentbna-atid ply supporting girder (Ref6fdri6d detail WA3.7,02). 'Oear-Bob, .Fota sihgl& ply carried tfuss'WtIT A width less than the hangef width you can install a prefabricated jack scab truss (w)Jpr wqod'Mlev 151ocki4g. The chord sizes, cb ro grades, and Alpine plate(s) to bethd same as the single- ply carried truss. The pr6ffibindatbd f4ck *§'dab trUs:s (*y Will hav6 a mHlhjurn )erigt of 48' and will have a minimum pitch. of 511 ?. -1�4e single. ply parr' reaction of .tedl`russ shall h req . p have a 3,5,00# or. less. Attach 'p're"fa'b*d"c"at*e'd"j�ick..bcab..truss wiI4 two (2) ply of '0. GUn NWIs at 2" Q='Qt per r6vV., -staggialr&d I " (See Flgijr6 I b6low). Please -refer to -the Sirhpsqn -Strong..-Tie Catalog GC 2bl A, page 216.j riggreO:$ for more information. pjiqure-'I Fora sIRg 16- ply.gifder:that requir,6s Wood bl6qkhq W ai hleve4ull deEFigh load value for- faqe_mQuftted Bangers -attach one wood. block to the back face of the single -ply girder With the same si ze and qr6de:.a§ the bottom chbrdpf the single ply gj.rdef. Thewood• block fdii4th to, b6 such thafth6W6od btqcMng.-extends to each• adjacent,panel 'points (*dbs �thd bott6mch6rd interse9tions). Attach wood block with rows of L.-I 24" x3.!Y- Gun N.4s at 6� b.. C*. per row, staggered 3.0'applied to the Q750 Forum Drive 8uite 305, OMndo, �L 3.2821.. (fiQq).521-9196--(863) 4224685 www.allpineitw.nom P ALPINE single ply girder face, with an cj!Oopna�l (2Q) QJ2$--x3.17- OunNails at.eacb,panel'.point apptedlo-the wootf block face ($6e Figure � biAb.*.).'Please refer tothe Sotosbil Strohg-Tie Gatalbg G-C*2049, page 2% Rg.de.e 1 for more-. infortnation. Figure--2 The -applit-Mon of -.prefabricated jackscab truss fdr wood f[II&bIoc:kIhg or wood blocking to, achieve MI. design Toad value for fa.ce=mount6d hangers must be approved by fhe- hardware rnanufaciurer'., All edge -and end dittaboes, arid "spacing for all nail connecilotis must be sufficient ORYient to l5reV6nt;§pIitt71ng of 'wood.. If. I can.be-Qf any further assistance or N you have any questions; please give me a jcal . 1. Willibri! H, Wick-P.E. Chief Enginpar Alpine an ITW Comp Engineering ng'Irleering Department Orlando,'Fl- 6750"FatUm- DNia Sdke:306; -OHafido,. FL 32821 (853) 422-8685 ALPINE April 26-,201 b Mr. Bob Michefe;1J.'s Carp enter Gontract6rd. ofAmerica, Imb- 3boo Avenue'% Roftwest Whte-i& Mv6n, FL 33830-6201 Dear Bob, Rd' Strongback bridging Oij Fbbf-jtru§ses. 1-understqndthere is some coridOn over obrIfecdminendAtl6hs f6t.strbngback bridging on -roof trusses. -Strongbackbridging jar roof trusses is npt. a requirement Qf"ANS I-TPI 2014 nor is it a requirement of the BLiildihg COtp6h6nt -SAfety Inf6fri46ory. (Bbs(), But strong6ack. bridging on roof trw§ges is recommended, by Carpehtet Cohtractdra 6f*America. Stidhgld& bridging -geN&s the following two functiih.sr - One,, Bridging aligns the bottom -chords after they are. set -so they are uniform along the ceiling llife and heilpa-with b0iling sqrvjcaabliify - Two; bridging reduces fdt&6 deflection of adjacentffilisses. . - Strongback bridging'.does- dot--prevent-.of redudB7.,oveftill indiVidual deflection, edpecially, any rooftrusses. h _$trPn,gb.gc*k- bridging In roof trusses d6es 'not serve asteMpbrary..or permanent' t* bracing and is not - .intended *io disitrfbuik of share. design !otids . -befw.eeh Oqri�;equen i�, ti' design loads 6ve t a desig o . been ?ccourjtedfbrWM this def-Ail4d dontinubUs-strdhgback*Mdgihg shovicl notbe.a'ftched betude6 cofnnion and girder 'tri-isse - s� The use -of strongback: bridging, shall not interfere with other design considerations as sgeciffed.69- tffo Engiheer Of Record 6'r ther Building Designer.. The ddtLgends otthe 'p;ttoriooack-bridging .shall be -attached to awall-or another -secure end restrains, or aLs specigW: by the Erigifiee'r of ReWdor.tfia Mlding.De'sjgher. Strongback bridging shalt be -a- minlImfirp of W notiiinal [UrnbOr odented -with the depth Vertical. Attkh (8): 1�d :common' nails (0.162N3_51,') nails at each intersecting Tdmbeh When exter.)ding the strorlOack brfdgfnq overlap. by at a minimum :of .two trusses. The 1'ecabion of. the: strongback. 6nqding maybe specified by'tlie Truss MahuftictUr6r, Enlfie& bT*Redord, or Bdildihg De§1di-dr. Please refer -to BCS1 4Strdn_qlJackhg or to Alpinp, 8TR8MR1O!4 detail for more. information. The graphib §ho,A6 (Figure 1) Is for gshirrlc ffluttriftve purpose only,. 5750 Forurn Driva.Sulte 305; Or%ndo, FL32821'-(600) 521-9790-(863) 422-8685 www.alph)eitw.com* ALPINE �t?.h-S -HCA in. 54a1a) Figure4 1f 1-can.bd of any fiAWassistance' orif-ypu have• any questions, please give me a. call. 'Sinc; rely., - go. 0861 STATE William-FLI(rick T* STATE 0 Ctftef E-.ng[nper Alpine an r1W. C;Qmp;�ny V5- ORIO "Qw- 1,8NAL Oddn4cr, FL 32kl 6780 Forum Drive gulbe Kr&, Orlarido,'FL:M21 (800) W-6790 - (893).422-8685 www.wp1ie,tw.4;4m I f 10 n' uugnrghp q.a,n•=r•+• ort b� •n r mxas ro+rt •+..,ru . r+++'�� a dtoow ggal.Howia.,y •JNIJ d S "•N• x••+rw11P "'�'i",eu lew.a ige( sfR.w.. gM1w,v ,s+ou.ueJ. oaseS�B {S_�i�y,,. pq:a�+s.i wnLN'nd aiw.ry6a.a5wra+pc•1�yq�s�Ip. RBI �eyp+Y 9r„'i+'"'p ,pn .c1 •rW Y?w. IMu cutt AO'i Atld ' Oj'''•�.)�-�.,. 1pp 1e�a4� idun �Yufa WY11'a0M ai OM�4 �}�47 �..Vw,Y• r f_ y 4'. VI Y � IVWt �%pp! • 1 .yy�,y 4..af t vuiN 7'�•�•+• .t •^`K '�4s ytry •!,•Iw,• w•aim+'N�N4, aNWI')ODMII ND .i 4i 'Q .' .. • ..7 ��"D a^ 'r w.'c k'n-P,C.9 -# ,Ravo4!.{•M ,a .•IIWs 4'7.aR•9 �Wwadw.! P!n ,Alt M'. ► �'a4 �,/+tl . •nm1Hr•0, •l�la �+vpWv, f i YD9t', jaw W . i ... �Scl ��' yy :: •ax iva.;bi{+Nvd qsl '+q".z�a' + role .,c•4 ag�.s I.aP•I•!� T .s 7y,}Iv;4c,ga.a`lu+!•I.WwvwM ..efwW.•+Wlv�i �tIR+: P•'P3i•RI+WeA• .n 11v4, bTbTRlijHtIlS E) ANd- 3Sd 'Id.31 PAP ^►, puo�, .wF 1�!a�n.+� w P•V •al.a„a }nat i w P+•W •rwa� ,P•!s euin°F1�t ..z i•�I['l.�.W+°"I.�,mne+„+vN•:tn .n,lwl:• f,,.«it.eyvd�- �• . ,c4+f•+, .,e/ • o xba au. •s W+�aao � iSR:w• w 1 w4"�IP K7TO/oT '311VO dSd: 1Q l ; W!.w �N!x�J° b+4P��' i� r953?aww au xa.P(q,'.+sa.+rwx,'► •'+e•+�++ . )13dHrJNOMl'S` d3?l iSd "j'I?•� '� : • ' a anvltldtraml lama q I H�hiraacavraoeemmvr�°a",i..�x"rl'a'� b jd 'Q :••„ �..;.•*' ' 'I,,�r S•34I,LVN213T1H 1N3WH-3V.11.1 DNI9Q•Ia8 AJVd6NUd-LS . t i 1 I '(uol4.ow.a0fui • vv uauodwo Bu n o' aafa.a '6u B -1 ' 3 Ipll. S)' IS�H' } I pl q .tO., 4H'Ex.B2Po) situ) �jdng6uQ a;s Qulp,fjq a,a uoja.nw.jodul lvuoj+ Ipptr ap3 0 NI WU:) PUT V s mm (:Asx.elrot NOWNoo pot (i7 �l1 x?q'1H ai. 7 VKUN08LS au d 1 ld' ct p'apuawwona.x xiciuo.a�s, a�o�a tat{} put 6ujOppq ovlly xoolq NVIVDs �o m I. ++w a;_ , pt UN3 H3t!3 ld'.03NIdalS3M '. kg ja -M110H • aNb• 401 3yg�Npals < (1wI 1w) 9k2 lv satlN uoek,BZt.0) NN9/x06. .sl. Non'g6uo ads. fo U4j ntln}5ul aq:} Aq paiuvNua en,p. i ao c.aex,erro>'NONHO� PDi <Z) a:at . sWa� siCS aoolf lln. fo a�unw ao3 aad a41 f• nrw+ ae a a 'sda}s;l.00f sti gzih$ sptibf �ufgd Bujnoid Pa.gn a.+ puuN A ak' ? :*4 p0 wo a f 6uj,.p qo taataa°ovaaNlnais aonpa a o} .san aas 6ul6pl aq NongauDJ4..s 'ssn a}. ua�ti( po uaaryt� aq. -%puol : 4Pjod fa uo14„gj,4;.slp aye. Wl '6ulpin �o�• :uol}714pn �.!I 'WOl}o,agln lva}icon I o laq waq.sAt : ssb,4 : toj .uol4.opuawwooaj ? • • ,. •n: sl..,eulBplu�l..ylpdaBuo.�}s,..d).,lnjnol�..�nd i ' . 6ul6pl.ag, ';.uauodwoo ssn•'.1j: jt npinlpul •q?na• :aof• s4.uaw"Inbas3 6ul:?+o.fq :aq:.- -;Qzr CQ(il) 6ulAb,4Q ssn.,U 'W.a}SRS s�ivN <.ocx,ea � Nro%XOH' POt (S7 46lSao: PH+ •a} la�ZZI 400" .ao ,aod dub fo. • u2Wa a nbai,a 9urJ Dnoa s• un caodw 13 � 1 • T } � �• �• I ! ao. �tdN' •<,ex,errm Q NONHoa Pot <e). iM Han utf sl .,ew�5nug,• 'djgoa6uvgo aa.� ul..pasn d1Ua?l-n.15[w Bawl}aUlos a an �6Upn •a,. p�ln. ;6uI¢p:I�q, stx4# . ;iL -.� 01 x?tlH0N0alS HOtllltl spbq� aw uawg3ro� v pa•'131'ON ,GT vD papuawwona.a sl 'slla� ap ILd139N adds sand 3NU lsv l iV'NOd 211'S ul ge(rny.I's• so' •paugl}lsod' !Buj6p1 ?q iOlog5ud.a}s sawn hNtoalms -)I so�oalr.• dvl 'NAaHS.•SV ON OM& A0.(1311 NI. 131VN atlas. 'Wa Sds .a00 aq�; �O sSaU }1}3 9xa } 1 d . aqa. ul di;na.aoui jln.aaho: Wo. ul Bul}li7sa a aro..9' 1 ).a Snoa 3.N1 Shim (;Wcx;sal,o) NnWAX Pot HaoS H3tll1V :+sasgn,q. jnnpl,nlpuE �aaaN4aq 6-,-- _s pool • dolanap •Hun o} sj .6gj6pj:ag ap-ng6uo.l}s fo asad md- aql1 zogwrij• papb.a6 n; a+s, 9x2 wnwiulw n •aq. •lings• 6uR6•aq pun• 13ulepl.aq >poquUou}s lldl ' .aa wn a bia6 ssa a s i q 1' P� p �- .• naH13�o1 �N[oataH- xa«rmNaatg 11n. l.xg wnwlulw o aq 1p aqs sl{oolq uo_gnos 11'd-WK ' SN1IIIVCIN3WWQ33'8. •SNID(IINE AOVE MQN L 'S ThA- q i IUWO 'ORE rI 6 'AN' 5000 AlJ5TpBE A. k< G. �SFlll-. r�fFFli�T� l ;t{i ':(7' '•'TfJ' l3Pi� D0 1 - -I- L-..T gow.t."-w t' - . MAC Ei1fcL i. . L11. b' E'•' "B' fci �SS9iKf :I i L }LET 2�TY1�3t�#3•.• moits AnD.: 6• I.. VAT� OR' AMR L7 _ I• -d= Gt,9ald�nF�4'ft�t�a+tiI•'4Vls: .. �Mi1T:..I-.f,1cHcF + rJm'ki.d>'�^2c� sir t ..,: wo i�. r r Y�itkft[I�"L1A._ E�� y . }.IPkykuiik Iliir Yyalr'tT3f,i'.]F&, Y7Tf,t �?-C���`�+.��':��.':�!:' �1•�!�-.. ...... -- .• �:.;:iy,...'_�''as.9'13�y�lrlek�'38.,�Sf:�;�}ifF.��1.j�+,: i J�'—r r'iir.,^' /�1? :. WY RIll •.; .' •. q�v�L.:v-r.r'.r1i,ApgL:.i:r�l::d::. .-anti.-6.'.T. ice'-•"" ,FVd ;: ..r. r • •yam , �''r :� ar: • ' � :; ; �.,�; cn; �y, I �fy�"r� �} . . ' - - i� �T��' • L� � �Ck�C7e'•fJ•;J:''t�' + • FJi�:' � f ' • a•. ' . ' ' r•: a w-' p.,$(�t, �7k ,�y� .Y��e '.`,.. ' _ +.. ' . ' ' .. .. •. ._... • J!•IrrYEI ' U%lFdi � fi'�S�F{�� kY�:.t'ir'�1••`SPr""1 - - ,. - _...W:.�....�:•.::::,i' • • �J4F. ell ra •� '��. ,tea ,fir -� ti• ,,��i •� �.,.r,r,.,-��....«.... 1,10TQJHOd38 EWRI 21Idd3N 213EW3W -J321 tt+v./IvlfaJaR• �J9I la.tvt++an wagoRR� /'f�SS 17J•'aw, ;'NR qdl fwa'1;Iw •01IFF, 9NI3ddS isi;ir vR al+4i op; irid ■•ieu Ita.u.0 1.4aWui�I4i •!s u^IivY+elq�i� 'i'1•S 1 7,WlSNY J•d J•4011M1 Syio�yr u7�.•P F •p •Pr '�H • 11�vJp 1My. !o im Wv AftriN �,,p 114i d+li+ll �t.M .10 Ou • M Nuvidlaaa s+ivPN '�•1 aHeM` is ' I rpyddMMi ,d puoy JO! Jv ,f J:V SMa NR •auay.ro uea q LTJ; •4ir11^R � ua+! u°IivINP .W..la! .fylruodsa7 �q ie� Ifv4s �uf �v+0 s;uauuawa WWppMc nu •lye p.d yeld pJap4oir ..•/ Z�V , a•ia�,d�v lµa o qw a•t In a Fqv Ni w u .0 m9� �.d p•Ily! .__. ,.,...,. a,Raai�d�: �_ I'-•'i5'JC JId'6 TJip1 I �l0lC} Jij•a �Vqi� I #0999 #9;609 #08Z9 #01,9 18 + 9x5 4xZ p'+0�3 ao qam p.+ogo .40 qaM #SVt v #040V #OVSE #09•VE #GELS #SBUS #OOSV 096EV rEV 9x2 p-AoN3 "10 Clam #SERE #SOSE #9ti'OE #SL62 {,xZ p Hoge ao gaM #SVLi' #962# #6E9E #SESE `9E 9x3 pjo�{3 ao gam #OTUS #OE6-a #OEGE #OLt'z VxZ Pu043 -10 gam #SLSE #SITE #99E2 #OEZa ,OE 9xZ p-Ao4o 'Ao qaM #SSSa #GTE@ 9096T #OT6I Vxz p.ao1,18 .40 qaM 14029E #Stra? #58ST #S9VT rbZ 9x2 p.4C)go .ao qaM #SVLT #S6VT #SSOT #SL6 VxZ p aoy8 to qaM #STbT #S621 #SSOI #S46 rst #x qaM #008 #OEL #2E9 #OZ9 raT vn A1u0 qaM dAs "1—.dcl I dH O-3dS dmIS ,iagwaK - ao.ao3 lDlxd .aagwaH wnwlxvW �^Ya IuW �inl BBCC1 my4pio]Mu1NY �jj Q1u1 � D 11roq-aQ t3ul:)'OdS TON pa as B6u}S n1oZl al lu — aagwa gxZ pa aav}S Inoa algno — aagtaa� Vxg aovd }uoa3 = O Isll'ON (Ulw `X x .82-VO) xoS POT a�vj )iovH = ,�aeBv�.S • — 1 r�i r + o + 0 + O + O O + o + o + O + 1? D lil I , , •s , spool ul—al} Au'o },aoddns }ou Aaw pJ04D URNQ E -va Ao m vld .4o}3auuoo aqq. ulq}lec BuI.A.•In000 suol}oas Clean jo p.aogm paevwtp joj pawn aq q.ou hl3w llvq.ap .+lodaa clgl 'saollds lafavd-alw }v a}vld ao}oauuoo uao{o.aq Jod pawn aq stow 11vq.ap-MuCIDA still fOS91 apo.aB ?1SW puv T# a,pv.ae lvnFIA a} pa}Iwll sl llv}ap slg4. q}IM asn•uod apo.a ,aagwnl paq.}lwaad wnwixow aql -,aagwaw apls 4:510a oq.ul (ulw •,gx,S'6VW sllvu un8 ro xoq P9 eulsn INN 'pa.aa86ro1.5 saao.a '-0 ,y }v sao.a (B) aa,agq 8ul5n s.aagwaw 9x8 o}ul 1110 pa.fa8uoq.s smou /.Do ,y q•o sr& a (g) oMq. Sulsn s.aagwaw ME o}ul IN ,lauvd uaa{ouq ay} my}Iaa aq q.snw (S) q}eual ,aagwaw gvoS CH) + (1>�Z) — (s)qq 8ual iagwaw apls wnwlulIW av4 uad gvos auo lddy 'uagwaw paOvwap so salmads puo v lapv48 Maxis awns rs aagwaw apls gxg oet} Jo yxg oral o CS) (g) oauv pe6vwvp jo apls tlova uo'amuv}slp Buillvu wnwlulW' a ('U uoI}oas pa0vwap ja q}Bual xrow ,BT 'oa.av pa9vwvQ = CH) 111v4ap slgq. q}IM Aldwov }ou op }vq} s.alvda,a atuv .Ioj ,aa,ln}ovdnuow ssnd} auu} }ov}uoo paAa�to a.av ssnuq. .la�4d. smvaaqI� cmj. uvq} a low ou pun lauv 40 v a 44.1a sessnuq.allc Alduajeuisuoaod°�clu0 pjlvnas1 uejlsap SMI -.aagwaw Clam .ao . p,aogo ua>loaq gq•IM ssn.l} *a ao.4 s.alodaa saljPads 9ultAOJP slgl Proo o uo vnQ fa pasvaouI aq vw sao ,4/0= uop onQ pno`�1 ua>{o.AEI p8>jDn.43 SCARP (IM) TRUhP.'jJNDER VALLEY fRA'MtNG RAFTI-5-WOR RIDGE CRIP. L9 psf(Tl-)*hAd-2d psr (.TDimdr. . wont �WM MfWt&-.twP-296 sleeper$. 5. 31deydf W-Adrs' Twd'Ak Ir $1 d ae fy-AfIfill S-4 td9ad0s.cach SlaqPAr-J0M-f;cf Mdjlw:bobrd,'W-TGDf bldck A led tog-11SUS xFoR VIMIi .7. -RIdja-,bq2;ra I-A.&S: S, 4ruffldIC MR), -Trbsft0.'6lb4kft* 4*16dtom-0111 30. -Fruz;4;:ooplle-. 4%4d4vC-"Ili 'T"I'"I wl"Aja' 4-16.410e:hhV -crwI.Z6-PPfifIln'. sldd-lcylonpO USMI .33. :rAl19PV2ehv't0;cB'fdf 4 IffertUL-n . 2115. NAILk a 4L o ygly walhafigfa t- pp�funwaAa v-rn1daiilfo'brreifter, rq nlrn ofV-8d /ma .011 "M r u orz a nb NA.Vbl Y-Att R4 under cj,. tL -gj 'h*t(UtstjknrA b4ptwoan�M-4014V-or q7S m -AOFhly All NOS -maxiolum "Wtdbf height; 4.0-foot Ha§h pb)trtnon hire pails -746 W niTlhiin Y—LD TW Llo AM -OU 'AV $Y'v -viftifty of Nvo.foam 'I'I k4 -km bk�� TC 1) D ZO 7 '7 DATIV j0/q!-/ im"14y ON 1-11 Z... .4 WNW. 4y -tp w WA e .0 o o M W. a' iwY Ilk 6, . I ' M Be. LL 0 .0 0 7"K '7- F R, 41"t w , K f"k to ♦L 6T •M T'W=Mw .(Wwfq c 9 ni­ Face -Mount Hangers - I -Joists, Glularn and SCL N 0 0 I -1mrs-IM-p-so-N] ID These products are avagablewith adclillional cowoslon protection. For more Infomletlon, see p. 15. Codes- See p. 12 for Code Reference Key Chart. NU At te 0 o wab A % S Code . . . . . . . - - flet. :.V . .1 -Roof. Sno Min. IU5256/16 25A 16 2 (14) 0.148 x 3 - 74J 1.6 0.1 8955 1.42.5 1,5155. 1553 Max. 1 (16)0.148x3 - -a I.B05 155s 212 x 16 M1112.56116 21iG 15%. 21h - 124) 0.162 x 3Vz (2) 0,148 x 1 1 230 3.455 3,92014.045 2,970 3.370:3.480, 970 1.945 i.205,.273 1.675, 1,139512.045 U314 101i 2 - 06) 0.152 x 31h" (6) 0.148 x 1 1W HU3161 HU0316 ✓ 2% 14Y, 21h - (20) 0.162 x 334 (8) 0.148 x 1 1h 1,515 2,975 3,360'3.610 2,56512.895 3,110 Y * 3;22,3.1 I.A81): - FL LA MIU2.56120 -21h 1,�i -.-plegWy. -(a W�T AM , g6F 21h x 20 21h, 19% 21/2 j28)1 0.162 x 31h (2) 0.148 x 11/2 9-30 4,03014.060'4.050 3,465 i 3,495 3,495 ,2!/ _15 IRAs, (281 7 !AW-191 104.51 95, 3,495 W26--t u NS X 9 A to 26 21V%vide Joists use the same hangers as 219 wide Joists and have the same loads. Z? .14WEIPW lok 1_0100-fmt a �q z !f] 0 MIU3.12111 31AI 11Y. ZY2 - (20) 0.162 x 312 (2)0.1480YI 230 2.88013.135.3.135 2,475 2.695�2,695 FL 3011A HU212-2. HUG212-2 I v 31.41 101 is 21h Max (22) D.162x3'/z (10)0.148x3 V,d5 3,27513,695.3.970 2,820 3,180:3.425 rV­ Max.- -,.(b- A -1Ak_XZ Ur q A.40 U -I -i5li? Y '... _;�� ',7�?S :-7;e�t 7j825 IBC.1 A A z, 7,-!;� T-1 :8: B4O85 FL I -F . . . . . . . . . . ... J3 18110 _� ! '14:�_,. - ­­ ff� M.*Ag4b 311 x SY, HHUS46 35A 51A 3 - (14) 0.162 x V_ (6) 0.162 x 311 1.320 2-785 3.155 3.405 2.395 2.71512,930 1 H GUS46 3% 4% 4 - (20) 0.162x3% (6) 0.162x 31A 2,155 4.360 4,88515,230 3.750 4,200 4.500 0 23�8 0:,x 1:415 i�q A 415 6,41, IUS3.56/9.5 3% 91h 2 - (10)0.148x3 70 1,185 1.345 1,455 1.02011.160 1,250 MIU3.56/9 3sh; B 'Me 21b - (16) 0.16U3142 (2) 0.148 x 1 'A 210 2,305 2,615 2,820 1,98012,245 2,425 U41 0 . . . 8% 2 - (14) D.lBZx 31h (6) 0.148 x 3 970 2,015 Z285 2,465 1,735 i1.965 2,120 HUS410 - -i I - I3`n. 1 81% 2 1 -1 (8) 0162X 331 (8)0.162x3l/- 2,990 2.125 2,42012,615 1,810 2070 2240 3114 x 91A HHUS410 - 3% 9 3 - (30) 0.162 x 31A (10) 0.16ZX3'h 3.565 5,63516,38016,,145 4.8457E,486 C,-.s HU410/HUC41D ✓ 3%; 8% 2% - (36) 0.162 x 31h 02) 0.16ZOIA 3,235 7,46017,460 17.460 6,415 BA15 6,415 HUC0410-SDS 3.7itt 9- 3 - (121 Y4'x 21,V'SDS (6)Yex212SD8 12,76;; 4,500 4.5001;.509 3.2410 5,23.0 2.Z4()j HCUS410 qVis 4 - (46) 0.162 x 31i (16) 0.162 x 3 1/2 4.095 9.100 19,100 19,100 7.825 T825 7,825 IBC, - - 41/z - (16) Wx 2W SDS (12) 1/4' x 2 ME" S D S 5,555 5,72016,720 6.720 11 4,840 4,840 4.840 - FL, LA LGU3.63-SDS _3%1 3% 8to30 rh;,CFU3.6 3-Ei SEA 91/4 to 30 , IlYk - (24) YV Y. 21A" SDB (16)114'x 21W SDS 7,260 9,450.9,450 9.450 6.805 6160516.805 sp - p AL . 94,. . . . . . . 46� ff?14�75­ �,695 2,695 .4 I N4.1 6 _&K. _j� j950fZ245 27125 P-1 T A, viT .3111 2;490 19q. 3,425 HOGQ41ZADS., 3vi WA -,.F'; 7-r .4 JL 4 .. .0 - a LqQ Q .8,035 DS'-*!' 04-Y47 X AX D 190% US -t: 0 i 6.9 5 10.5. .0 fi;8 0 5: 75 146 See footnotes on p. 150. Adjustable Truss Hangers �F �G This product Is preferable to similar connectors because 'w of (a) easier installation, (b) higher loads, (c) lower Installed �j cost or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. ` THA4x and THA2x-2 models feature a dense nail pattern in the I straps, which provides more installation options and allows for easy top -flange installation. Material: See table Finish: Galvanized. Some products available in ZMAXD coating. oSee Corrosion Information, pp.13-15. Installation: CD _ • Use all specified fasteners; see General Notes. O The following Installation methods may be used: 0 y • Top -Flange Installation — The straps must be field formed 7 over the header — see table for minimur t top -flange requirements. i= Install top and face nails according to the table. Top nails shall not be within :'a from the edge of -thee top -Prange members. For the THA29, nails used for joist attachment must be driven at an 4. angle so that they penetrate through the comer of the joist and into the header. For all other lop -flange Installations, straighten the double -shear nailing tabs and install the nails straight into the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, viith at least half of the required fasteners in the top half of the header. Not all nail holes in the straps will be filled. Nails must have a minimum rh• edge distance. Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min.) installation option acwmmodates conditions where the supported member hangs either partially or entirely below the header. • Face -Mount (Max.) Installation — Install face nails according to the table. Not all nail holes in the straps will be filed except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header, j The lowest four face holes must be flied. Nails used for the joist II( attachment must be driven at an angle so that they penetrate through the comer of the joist into the header, j • Uplift — Lowest face nails must be filed to achieve uplift loads, i Options: • THA hangers available with the header flanges turned in for 1 3ve• (except THA413) and larger, with no load reduction — order THAC hangar. Codes: See p.12 for Code Reference Key Chart 186 lye tYPIC33 Mor THAA12.2 Nr far THAC422 a�'S and THA42K � F• q R 2W far .. �' TW25-2 ,.. . !• 'Y THA418 THAC422 Face nails Top nails pertable pertable Double W- Use tul table val Single 4r2- See ff nailertabla E Straighten litre double �? + shear na ling tabs and instal ' nags straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps may be installed straight or wrapped over ivith tabulated face nails installed info top and face of head( Double- } � Double -Shear Dome Double -Shear h I _ - Shear i E-.F s:; Naifntg ` Nailing x, Side `✓ievr, ;;;, (AvaNli6 erde Vi on aw j Do not Top View I bend tab some modes) SIMPSON x 2140 �THA29 o firo h Straighten the double shear nailing tabs and instal nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation typical rrv+ca Top Flange Installation er tD trite 5 p.187 Sim- strong -Tie`' Wood Construction Connectors s SIMPSON Adjustable Truss -Hangers (cont.) W These products are available vrith additional corrosion protection. For more information, see p.15. 0 0 U d -_ s.. 1�imens7d'ris.' 4 :Mini?' ,� :' Fzs[euers' ?(ri)y `:: 1x15_`_;„ _ • �tt�lwa�ifg cads ^ SPF/HF. Alluwabie'L:-oads 'MoQel' Ga ,::.::.aggbTieptfi':,'.;fari7in;M'e'0itier:woe:Rbpf7.: _ E•.. Member ce:,. - - _ �� (to = 15) Wind ' (125/16U) Code net. Top• Hea2e� �d ''fra73 ,a$-ru�.:P"'�i -.•'�..2 F •:%`. ^z � 4: a3c_'.+3. .:_^i. .::3;..' y�y�_.y � � fr .u',;..., y .=m�-,.�-•'.. `'" �v $h+a'x•^� .r'�F�.7 _ ..ti aTyh..'e4c"�� "i y'CY.-PIO(tg�Pll{i Z 4�{-�e`1'_ l^t-l':'.Ai++�}�. - ~ �: F%ros'. 114'I — (fi) 0.148 x 3 (4) 0.148 X 3 525 1.; 50 ' -50 1,75D 459 1•,i30 1,33f) 1 �30 THA29 18 1% 9 YE 51!J.E�10.1480 2T4; — 525 2,014 .610 I •-- (4) 0.148 x 3 („6)� 0.146 x 3 (4) 0.148 x 3 'L.6?0 450 1.985 1,9 5 l; r°5 .iH%1213' `•'r8::13e',13'sfr:Js,-? "2' 4j07ACsriF3•: tat8149x3-(4),0:148td•Yz= ~(2)0.148 -'.;¢4r�; :tlfr 171' ,t.17 THA218 18 1% 17'h6 51h 2 — (4)0.148 x3 x3 (4)0.148 x11i -' t.a6h ?:t8r, 1,46D —' 1.110 11L3 1. 1A IBG, _ �THA218-2 �16:.vi'a;1�'�lSs.OJT,.'2`:c'.-°-(4,�D;15x3+fi(2��1Ec-x3'h:.(IZk1:a4�s3r:rY_-,ti:1;dGir��.�9:n,'y995 ' _:.. �. .....: _" . ..:7t�97:5'ra"1: '?.ti15•�. FL. LA THA222-2 116 1 3%. 22:& 8 2 ! — (4) 0.162 x 31h (2) 0.162 x 31i (6) 0.14B x 3 — 1 ?6D 1,935' i,99: — I t.Ms4 1,515 1515 lft/f4 �894"d1jr.::1E-,'' ,L`_ :. ..- .... _ U1 833" ; . a; -,-,-. .,;co-• -rn' . 1169. 1`6� �165 THA4'8 1 16 1 3Ye 171%171/a 1 2 — 1(4)0.162X3Yz (2)0.162x31h (6)0.148X3 — 1.960 1.995T 1,995 — 1A90 1,515) 1515 �PP4'2i'>G 3''�Z':7r(p;`„c } _'v ,'i]Ti231a}i0rlf2k3Yz d�0:I913i(�a?zrcl3}_."T.;:`'—. 1,49 1:51a:#; 1.5'5.:. THA426 114 .3% 26 ; 71/. 2 —T (4) 0.162 X 31h (4) 0.162 x 3Yz ("o) 0.162 x 3Yz — 2,435 2,435 2,435 — Z095 2.095 2.095 THA426-21 14 1 71K 2634,1 9% 1 2 — (4) 0.162 x 31h (4) 0.162 x 31b 16, 0.162 x 314 — 3,330 3,330 3,330 — 2,865 2.665 2.865 1 r '_��e.�e---tom. «y � ,��n.1.a..c`;?"S,?• '�:'� m ,� ?��5 -'.t�rr�•. .,w.:5"�y Fir-'asn2' ��-{"'^:;n•: "�' . �'Qy��•�,)":�?31�A' "`2'r`.f-;,ti�Y=+'r:e _. kp;��.-,%•: a i�t "�����Ri-Fi' «.. s•'T«S's-.e:�is. _:aP. _$i,.�.c'W;�.:. ' r. ' �- �� x% '1, �. Tr: �_, : -h. THA29 18 1 1% 9174a 51A — 9% — (16)0.148x3 (4)0.148x3 52552,265 2,265 2.25:: 454 195J 1954I 79's0 i :Tjjf�d$:.�;�,��_�e"-.•�3:!ie �11z•."— ;- : �1gy18_7�,r;<•„ �1735c ., :laa�ki4�xa.it4)�;i�x3, -�s'"i'`,'�3o�4�`i1i>JJ W855 _N-�,.;ci:_h: '3,5'-•.17,e">7'•20(�• 2?G6 THA218 j 18 1% 17% 51h I — (18) 0.148 x3 (4) D.140 x 3 2,451312,150 ( Z450 1 735 :105 _1U5 1 'L1t D 7'n 1y8;'" ,:- 1fi3�. {2�'F1.ifiLlt3.'' (8J.0:1�6FX$3!z°,118 �' i'� ��,�i�;"_S�:;i��, 1.595. 2:3�i,5 IEC, .T31A2,18�=j;:1�:•r3 � FL THA222-2116 1 31'A 2234,1 8 1 — 14%11 1 — (22)0.162X3b4(6)0.162X31h 1,855 3,310 3.310 3.310 1.595 2.845 1 2,8451 2845 LA Tf $13�' tTfi 183£:ti.r ) �48:x : ($7t3.rt48x ;�1. M 'E�t�.'+35:.:?u11 c{iC 105 >35Je12 p'?kY3 y � THA41B 163% 171h TA — 1414s' — (22)0.162x3Yz(6)0.162x3Yz 1.856 3,310 3.310. 3.310c 1595`2,845 2.845 224b T442 7;1&• •3i5`; THA426 14, 335 26 771a — l6Yw��— (30)0.162x31h(6)D.152x31h 1,855 4,41514,480 4,480 1.595 3,795 3.855 3.85.5 ) ifil44?�4" : i 1 Z€/d ''9ic c F— I6 E 47s- ' -18 (3D flaj 2r3'li }(38)U62x316(6)0.162x31z ^oj'0162%3Yz �i Q' o}+D: 57�C _ 1$95 4s445 .4;745 �4.746 FL THA426-2 14 7Y, 26Y,a 9Yt — 1,655 5520 5,52D 5,520 1,595 4,745 4.745 4.745 1. Uplift loads have been increased for earthquake or vend loading with no further Increase allowed. Reduce where other loads govem. 2.Wind 'l60) is a download rating. 3. Min. top flange refers to Ufa minimum length of strap that must be field-tonned over the header. The tabulated loads for the THs29 wilh 1 W min. top Range are based on a single 2x carrying member, all other' op-ffange installation loads are based on a mh%mum 2-ply 2x carving member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or ruler applications, refer to the Nailer Table. 4. Face -mount hshdlation loads are based on a 1wo-ply 2x carrying member minimum. For single 2x carrying members, use 0.148' x 1 Ye' nails in the carrying member and tabulated fasteners in the carried member, and use 020 of the table value for 18 gauge, and 0.68 of the Table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertfcepy according to the tace-mount naling requirements and the other strap wrapped over the iruss,chord acxording to the top -flange nailing requirements (see drawing on p.186) and achieve full tabulated top fiangs insiailation loads, 6. Refer to Installation instructions regarding fastener installa5on into carried fjo st) member. Based or. !he installation condition, pals A be installed either straight v,dth stri ighted double -shear naling tabs or slanted. 7. Fasteners: Nail dlmensiors In the table are Fated diameter by length. See pp. 21-22 for fastener Information. 187 Simpson Strong-TieWood Con sfruction Connectors Face -Mount Joist Hangers G�0% This product is preferable to similar connectors because ofa) easferinstalletion, b) higherloads, c) lower Installed cost, or a combfnation of these features. The double -shear hairger series, ranging f6m, ttb iiaht-cctpacii>, LUS hangers to time highest -capacity t iGUS hangars, feature irmcvati':e double-aheur nalrr.1g that distributes tit,- load througn two poinds on each lost nail for y atet strert`-th. This allows for fewer nails, faster installation and the use of ail common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX'' coating. See Corrosion Information, pp.13-15. installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to a.:hieve the table loads. • Not designed forweided or nailer applications. Options: • LUS and MUS hangers cannot be modified • Concealed barges are not available for HGUS and HHUS • Other sizes available: consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart 1 i a 1 Double -Shear i { Nailing I Top Vev I 1 � "v:�•• DoublESlmearNaling j Side View. g Do not bend tab Dome Double -Shear I i - Nailing Side View I 1 OvOlable on 1 r •;. some models) t HHUS210-2 MUS28 I.r %HUS210 �I (HUS26, HUS28, and HHUS similar) HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 193 Slmpsori Strong-7ie`= Wood Construction Connectors ' SSIINI,PSON Face -Mount Joist Hangers (cont.) IJlu6'gC�..t tyf' ".. D mOnsiogs In ` `FaW'11 s; VIM.. 'tleighEv 1 t1!n9' :..., J- _.. s _. Single 2x Sizes 19S24:':.: ;ate_...:_.; s :1�/e. :,1 :. `4%A'lT+ '1�i;:'•:Id}O.i9$X,'3'ai s(2}0148•x3:a ,u)S26_--'-.''=% 3a.•;4.`' MUS26 4'%G 18 1 Y% 51 e 2 (6)0.1480 (6)0.143x 3 HUS26 4% ( 16 l sb 51. 3 (14) 0,162 x 31h (G) D.162 X 3'/x HGIgSZ$AL.;13ert�:.; � �2:''��e ;.�1e''?:;5i,..i2olm;Ys�z3'::::is}ti.T�zar§i�r: Lt�211 .:43i�°:�'.}6 :j$ie:. MUS28 67. j 18 1 P 6-Ti. 1 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS2B 61k 16 1sA 7 3 (22)0162x3h (8)0.162x314 HGUS28 6% 12 1% 71r• 5 (36)0.162x3% (12)0.162x3Y. :L11S27U::"_;1t�s;%;t18•"::1fs:`=7�Ss`,;13k•i.' (8)1flABx3- i(4j:4k148ti3'.. ,y[fS21ta,:` `_=83e,`.':}t;16;s' s�1�e' ,;;9;:d::; 5;=:• �(31l).01fi�X31z.' ;1;16j'_ ; fi2',f:3,''' ii$3er: •ji •' .'(4$ �.�ir2;&31k it(]6)Daf2 3' 1. See table below for allowable loads. These products are available vnth additional corrosion protection. For more infomnation, see p.15. For stainless -steel fasteners, see p.21. Many of these products are approved for installelion �P Wth Strong rive¢ SD Connector screws. See pp, M5-3S7 for more Information. j :-1Nodeh -wig .�.j;"atlads,k,= y _ ;,.�e_.�.-�;�abode. �17(irtr.<;Uoj x=_' r5P1111oyVahtBLfid's,:-;:--_ - ;SPFAIFIlolvahie4Rad5°: `:NP•.`. :,4ip f11'aF(dor ii5yi4{:' _„- P ii; :'•FIouL ..;Snbn':..Tfgof'r.`}ywd': :UjiIrfL1 '•-:Haop. `.11DO) Spovi (115", Hoof. 'Wind :g25J' ' (160j lief. Single 2x Sizes s7r1S.L55�:;`.1725';::23:_$9�.`.'k"'r,^fi0';'::9�fL:._:-095;`,:::`�fi5_::605.:':'770,.` W526 1,165 865 990 1.01-0 1.355 1,165 935 1,070 1,150 1,475 865 635 725 785 1,000 IBC• FL �';0;:':�"3:295*,�-�`•41('ci.'`•=�a..4;.';�5 r' _: .]ADS;':.�f,56q' '1;560.'` .B '-'810 -'.•955: A,090 1;19D.`'1.�.yG,3, L•", HUS26 1,320 2,735 3,095 3,235 3,235 1,320 2.960 3,280 3,220 3,20 1,150 2,350 ^.660 21ao I i,7$rr J{GUS26; z `f ��`.' , 39Q ,?1��IJ P t s��39A : : 5 5: ��4,fi80:,:.:'S?2:'; 5;30' 5,390.' .':"?83. '3, .� .3;BlQ : 3:870 3;985 • IBC. FL WS28 1165 1.100 1.260 1,350 1,725 1.165 1,195 1,360 1.455 1,730 865 810 i 925 1,000 1,270 IBCLtFL, HU528 1,760 4,095 4,095 4.0i5 4,095 1,760 4,095 4,096 4,095 4.095 1380 3.520 3,520 3,520 520 41,450 rd25:: 626- , 015- "4,250 : IBC, R WS210 1,165 1.335 1,530 1,640 2,090 1,165 1,655 1,775 Z279 865 965 j 1,120 1 1,215 1.500 IBC, FL, �^,J' ..::Z�5�"2 adz LA HGUS210 2.090 9.100 9.100 9,100 9.W0 2 G90 9100 9500 9,100 9.100 1,545 5S%0 6.730 6.730 G,730 IBC. FI. 1. For dimensions and fastener information, see table above. See table footnotes on p.195. HHUS/HGUS See Hanger Options information on pp.98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skevved to a maximum of 45" and/or sloped to a maximum of 45" • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45". Allowable loads are: HGUS Seat Width Joist Down Load Uplift W < 2" Square out 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table load 0.46 of table load 2" < W < 6" Revel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cud 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load. 0.41 of table load 194 Acute 'side bpeclty angle Top View HHUS Hanger Skewed Right goist must be bevel cut) All joist nails installed on the outside angle (non -acute side). C) N L 8 Cl U 0 °¢ i 0 a $ImPSOiV LUS/MUS/HUS/HHUS/HGUS Thwe products are available with Fors Ness Marry of these products are approved for instaGation additional corrosion protection. steel fasteners, with Strong -Drive SD Connector screws. For more Information, see p.15.. see p.21. See pp. 335 337 for more information, �4D`d`er ,may a N"o: e '. bimetis(oriS�7ri.);; _3M.. .{fir::�9,C -..•1: -, _ ::.;' ;�ast`ein@rsn •• _ =: arryiri ', Cared - eiUbl t e;: <' t7¢mtiai y; ; rD�•! eAilbwab[ed;uad�r:�• "SP�1HF'lillDwahleLoads'•' 4lpffC florin bw: tSpidE `' :.Uplift 61obi' Snow fiaoi: Vfind NOT., QDJ'.kl ABB 1100? '(715):.(125) •, Code Rai. Double 2x Siizes kT152g2r"=•.i: 7a:-. =]))c. $'/a. 'Js' : {4).i1�S2ic3i' 6� {2)1)'_1fi314; r41y_'ll i�J S• ;90'-.. LS a55' 690=;:j801:.g45. 7;070 LUS�fi ? 4 i6 tB J+ ='2+ : �4ikr,,Fx3t< ''l4f'01$2 $?a � ' YA31FF .. 'f 9$.. �$10.' $B5: ,UOS� d:1190 1.570 HHUS26-2 4% 14 37% 5'S 3 (14) 0.162 x 3'h (6) 0.162x 331 1.32!) : 2,83D 3,190 3,415 4,250 11.135 2,435 2,745 .2,93513,655 HGUS26-2 4`'1s 12 1351. 511U 4 (20)0.162x3% (6)0.16203 i 2,155 4,340 14,850 5.170 5,575 11.85513,730 4.170 4,44514.795 i _iilitSz8:2'.t`' ' 63ie 74;is N3'k::.7 r7Ja;'i .`•:a:1jD62x8 i (22) 0362 x3�Jz (4)0_T62X9Ytf."k'3`4I (ff) 0:1 Zz.X3'/+ -� 65k15 >i6t :7�Q�'9jD. S9 ; :1;$1b. 1,130:1280 3'.fi40 •]t385r1,743 L,135 :4;435 '5.145 IBC,FLi LA GtJ _B= 6 5'._.12: $iis 7'Ss - 4'%'.36 42 11:a6T}c`aJr 1 i);162, 3 576Ui �4Q. '460;: 8;485,'64I5,' 6,415 WS210-2 fill s 'B 3'h 9 (8) 0.162 x 3'h (30)0.162x3'h (6) 0,162 x3'iz 1.445 1,830 12.075 2,245 2,830 1:245 1,575 1.7E5 1,930 2,435 I HHUS210.2 8N 14 34is 8% 3 (10)0.162x3% 3,550:5,705 6.435 6,465 6,485 3.33514.905 5.340 5nn 5190 HGUS210-2 8-. 12 35irs MU 4 (46) 0.162 x 3lh (16) 0.162 x 3!4 4,095 j 9,10D 9,1 DD 9,100 9,100 3,520' 7460 7,825 7,825 7825 Triple 2x Sizes 61J528;9t ? ' 4 ' s �2:�$ s ^5 ' 4 1 (2�)9i 3X �1`j f8�3itio2 x3714: q.. .. y{ 5 4;3dU } 85Q' =31 0' S t;a 55 3;73Q ?L170: `4,44.5. 4,795 IBC, FL Gl�S 9:= "=.: �36� :1bti•G3'`3 !j2)A� /k 3�23 _ �4 *�4s +; 4 7d&@ 6AW :415 6;415 HHU 2210-3 B-A 14 41)i. 875 3 t,30)0.162x31hJ(1U)D.162x31z 3,40515,530 6,375 6,485 6.485e 2,930 4.840 5,485 5,57515,575 -ILA FL ' HGUS210-3 811hu 12 41§is 9%4 4 (46) 0.162 x 314 (76) 0.162 x 31h 4,09519,100 9,100 9,100 9,1D0 13.520 7825 7,825 7,825 7825 ;HGI7S 1L 3'•' 10?5 • 'i$ : ' c 10?%a ;-� 3'h, 2D tl 5 ^�r , H: - }_• g� IBC. FL,� r _ i561:�?pP�r ! ,}:..1 2X 'fe vx69 t t :m*$,.: ,'l��r i�yQO ER A3 :;73)1 i,750 mot"-::..i .. .._.. '. . i161�S21t?;y;e`I g'r fib`fiSs '/4Q1S2z Si' 22)hik z i7i: 69 1¢i? �L(i2'1 �k, 1.900:.s,1'sU"BISO'.i3Sso:6,asD Quadruple 2x Sizes r - J�G(J526-4:=;`i'i?�.';1Zt.•? '8°!� ; :EF1Fbi'fr23r3i`u8}0:7'�D'f;` }�;3D; };QaO Sd,:,: 1;B$5' 3734. 4]7J:.4d.45; 9J95 IBC, FL, HGUS28-4 714 12 No I 7)(s 1 4 (36)0.162x33i (12)0.162x3h 3,235 7,460 7.460 7,460 7,460 2.780 6.415;6,415 6,415 6.415 1A HHUS210-4 8'h 14 61h 87A 3 (30) 0.162 x 31h CO) 0.1162011 311 3,405 5.630 6.375 6.485 6.48512,930 4,840 5,485 5 57515.575 FL U:#.":!;yrj: *',19:, ¢3ig.;93(e ": a.;, (9�1;P1tits.*iP (is�Drtfi2tir'/z;49`ii . 9 TKO':7 ;•rQIAD �3:524 ;782� :7,82$. 78251,7,325 I }iGl3Zh�:'- •1035; '25 fi Il15/a .,,:..L5 1O to2i(1Ti (271�Gi1;fi2". 9 .' ii :^a YliB ,n '7• • 6 :77iia ' 7178,D .'80, IGCq i, fIGU$I44:;;i.1234 ;lj;bs.925/eg4.:j66)Di62x3§4';122}0:�62X3G`3;>3iiZ57�r725{t,900,;87s70: 8:7a0 $,71D.!8770 i 4x Sizes 1 , (,11J96;4",r�,;;43eA ti8`• 33s.:a3tj:'>'2:4I�11f2)(3?j;:{_14)U:ll$S!:3�fii`;;_; US4 ]30rt�25. t .��� �i10:::$$5:yl�DS 1;090' 7.37U; IBC,FL 445• d,795' :#iHliS •.: .`:. , r ,'4§S-s',1_ ;. s �•/4-. �ar','S,A ��; :�F2'F�./z!;:(B�Q''i$`Ei•Si3ir-WS48 • > 43h 18 I3%s 6:'4 2 (6)O.162x3'h (4)0.162x3'h 1,0611 1,3150j1.610 r 2.0301 910 1,130 1,280 1,38511,745 IBC,FLI HUS48 61t 14 396 7 2 (6)0.162x3'iz j (6)0.162x3% 1,'s21 1.580 1,790 1.930 2415 1135 1.360 1,540 1,660 2,D75 L F HHL'S48 6114 14 3% 7Ys 3 (22) 0.162 x 31h ( (8) 0.162 x 3!h 1,760 4,265 4.810 5,155 5.980 1515 3,670 4,135 4,435 5,145 i HGUS4B 6% 12 ( 3% Ne 4 (36) 0:162x 31i; (12) 0.162 x 314 3,235 7.460 7,460 7,460 7,460 Z780 16.415 6.415 6,415 6. 15 1 ilfJsa;�ti;'v.',`; =�•1.lkA..18` :�f{s? �E3't.: �?2 � •(!S}Z1;'I,b?ks�'i:��0;,5�x3�1:Z``? r���.:'�24� 2-l? fkf•a2:5 3;Si�: 17 5''j;830' 2;d�5' t ;fif�fJ�,`4.i11`.:'•+ :4(GIJS44ff' ; :,:: :e)'/s' elm` `.'J s'"fsrt :SbS, J_ 9`•:` _9Je'::-4`; •;:T:•,i30j,��16'Z•X3'iz(1Dy?PJ62:9,iXr (96)O.j6 S(3'Fa 6j.V;162, 3?i a1rD1) r;.'U(f.. _'({h5? ; ��,�� D _ ., i9 lit iE?,;4¢:�:L6S: 9; (?0 °9,S 0' '-4i90B 7,625 5�fi35 �7;8 a,Sr3 7,B25 s 575 7.B25 IBCFL HGUS412 10z/s 12 3% 101/�s 4 (56) 0.162x3''A 1(20) 0.162x_3'i 5,6-s'5 9.045 9,045 9,045 U45 ;?00 7,760 7,760 7.780 7,761; HGUS414 1114s 12 35A 12r/1s 4 (56)D.162x3'h (22)0,162x3" 6,695 10,12510,12510,12510.12511,900 8,190 8,190 8,190 8.190 � Double 4x Sizes (1 HGI ST3 1.O S a • % 2` ::+�/a- d1�d '.di ,14b D:162 3 _rjtE$ OS162k3 3 '. 135: , 9. 9�195 • 08�'12j950::782A< •'T,82A 820 782D •!FlGt7537;17 TiGl)5T 7t4 't1{I?6o':'7e. 1J?i ._�2s.7i4j.2'hSc1=4_ 7ec 1R5�,,•R4' 't56�Dai1(4if�' t2]`•f1.lSZX31iz (S6jp.1Ji2x3':::f3ff3Sb 7i 1a5 .'8$ 95'• ,� : 080; ;: 35 2!3 ' 9;$OD i�fi0 4370'•"9:b30 T995: ;7995.995 030.:9030 7.995, 9030 FL 1. wNn,1 luaus nave dean increased ror eanncuaKe or wind 103d3ng with no further increase allowed. Reduce where other bads govem. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads, For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.mm. 4. Truss chord cross -grain tension may Gnus allowable loads in accordance, with ANSVTPI 1-2014. Simpson Strong-T!ee Connector Selector'soflware includes the evaluation of cross -grain tension in its hanger allowable loads. For additional Information, contact Simpson Strong -Tie. S. Loads shown are based on a two-ply 2x carrying memuer minimum for rated hangers. With 3x carrying members, use 0.162° x 214' nails in the header and 0.162' x 31W in the joist, with no load reduction_ Vloh single 2x cam6ng members, use 0.148' x 11Y' vans in The header and 0.148' x 3' in the joist, and reduce the load 10 0.64 of the table value. 6. Fasteners: Nan dimensions in fre table are fisted diameter by length. See pp. 21-22 foriastener information. 195 196 Simpson.Strorig-Tie" Wood Construction Cbnnectors Face -Mount Truss Hanger The HTU face -mount truss hanger has rail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum milling) apply to heel heights as low as 3%'. I'Ain:mum and maximum nairing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1h' max. to allow for greater construction tolerances (maximum gap for standard allowable loads is Y4 per AST-M D1761 and D7147). See technical bulletin T-C-IiANGERGAP at strongtie.com for more information. Material: 16 gauge Finish: Galvanized Installation: • Use all specified fasteners: see General Notes • Can be installed ling round holes only, or filing round and triangle holes for maximum values • See alternate installation for applications using the HTU26 on a 2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity Options: • HTU may be skewed up to 6711:. Sea Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strang-Drrwee' SD fasteners. Min. heel height portable Codes: See p.12 for Code Reference Key Chart t Many of these products are approved for Installation with Strong -Drive° SD Connector screws. See pp. 335-337 for more Information. Typical HTU26 Minimum Nailing Installation HTU26 truss and carrying member HTU Installation for Standard Allowable Loads (for 1/z' maximum gap, use ARemate Allowable Loads.) Standard Allowable Loads (1/8" Maximum Hanger Gap) SIMPSON roag- Alternate Installation — HTU28 installed on 2x6 Carrying Member (N7U210 simflar) — °Dimi;iis(d'itS�Gia: �:Fasiener's�6.j1_i;; J.�`•=;•��hFISP.Alliiwd6l'e�aads~s;�`�;'�:!; <SQF,(f�FA(Powablo'.(�ads. ode la ' in:%mi ;bow' i ohi., i Rot. (100j_i{}.St-:;(�25;7fig;-' 180 Single 2x Sizes �=.- :� - . s.;`'-�sfi:�1.'D'!..:,ai:o:':;t-r>3a�'t;6s6 <H]i726(Mln)"-':_ 3T/;:.j'-:.;5ii€�y,�:'(2dj`41ii2x3ri .{�4D;1E}X1°i4:=1zSDk`2J4pYS;201j, 2?3` ;'2� :7,o-75. t85Y •2,Ur ;015° 2;015; Hd1J26(MaKj�:' _ 5.+fi::> '1�7� T��/,,'s; j3bi (ZO 016Z1t "i=: i{U D;1r8.x ISii 5_ 9 rills ;iZwilA G�Ati' 7;335 L2530 "o: :�3Yl8 : 3'450` IOC, HTU28 (Min.) 37A 1 14% m 7)iu 131i (20 0.162 x 314 (1410,148 x 11h 1.235 3,820 3,895 3,895 : 3,895 1.060 ; 2,865 2,920 2,920 Z920 FL. KW28 (Max,j 711P4 1% 71,6 311 (26) 0.162 x 31/: 1 (25) 0.148 x ] i 2,0291) 3.820 14.315 4.69 , : 5.435 1,735 : 3,285 3,710 4005 14,675 Ir Hitll.LiT!) (f9( .} =`> • 3k(s :: ]'e : 9.j s .3 (32) 0;{62$3'd .3.2,25 f1T11210:(Maxi_;?J.:1.lrze:.;aaT'31r1:`(3217,62x37-�32t11j8Xiyz^1��751I:XGT�(sF'.`xa_�_%`^6_95'°2$50-.4G45:140 5` ':93h 5,155 r Double 2x Sizes HjFI�6•�'(Mn:)':' 33'aer e;57/s 315"XZLi);Of62X3{t =JljD0:74B1X'9.�?. Sj$ i s4(:. ,3_��. Si7:', r5kT??•, 1,305i j250r2090. 2;?55..2;4E5. tiR12E2 Max.j` t5he;'8.1P1 (20]-();1fi201, : 20)il 8x.3;_ 23 _' 94D "'L't� :' a.sax± if3n" .. 1,8 0'' 2530: •zFi55; G80 3,655 HTU28-2 (Kin.) 37ie 3M. 7):c Ti (26)0.162x314 (14)0.148x3 1.530 3,820 41310 3,820 } ,315 4.3104,310 4.655 _ 5.225 1.315 2.865 3,235 Z995 3,285 : 3;71u`.. 3.235 3,235 `4:00t • So I FL ,A HTU28-2 (Max.) 71ie 3"iic 7M. 3?% (26) 0.162r.3% 126) 0.148 x 3 3,485 Fltl)21027(WiP�•.:.2?/e'r3�%:935s.1 .';(3ZJiD;162.z.&3 :i:(lit)(liA8xti_sal'_ .'4;1jI)_uy :1_ 815 ,A;510-.i3,53013pa •3.610.1.5,51g �HTU210-2�jhi,N;�B?!d';j'$,��i�..9i;'s''3'.r�`;(3Bj-0_I62.ic3'n, ,(02fU;1x8`.Xis:•LC'i�'U==:dA'�II''�4`3t'0=�:,'i;7?Q:.'`'G;S�': �3r 5-i'4;G45 ��:,°,.c.6.:z.980: •5415 i. i re mawmum hanger gap is measured between the joist (or truss) and and the carrying member. 2. Minimum heel heights r%grdred for full table loads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. RedLrce where othar loads gavem. 4. Wind (160) is a download rating. S. For hanger gaps between ,%' and 'A', use the Altemate Allowable Loads. 6. Truss chord cress -grain tension may limit allowable loads in accordance with ANSUiPI 1-2014. Simpson Strong Tree Connector Selector' includes t-:e evahration of cross -grain tensio-i in its hanger allowable loads. For additional information, contact Simpson Strong-Te. 7. Loads shown are based on a minimum two-pDj 2x carrying member. For single 2x carrying members. use 0,148' r.1'A' nabs in Lie header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dmensions in the table are fisted diameter by length. See pp. 21 22 for fastener information. Simpson Strbtng-Tie' Wood Construction Connectors S1MPSO1N Face -Mount Truss Hanger (cont.) P Many of these products are approved for Installation with Strong-Ddvee SD Connector screws See pp. 336-337 for more information. AltPrnatP Installation Table for 2x4 and 2x6 Carrving Member - - -- ;Niinr - '3s}eneis�iri(z,1y: f :DE;6fllfc'7vilos`r= ; SPF1NFAllawa6(e.Loads; Model 'mlmum: HB ' :�!!�: 3t!. _ _ =Cdrrying • ; ;} `' " 5d''": =: `-;, 1f.�fifT:s : 4RF:r . ,. - - _ ' .SnbVr, : an r.� 'aNtnd' :. Up1it{ , FIRor •$Yiovu:• „Roof :Wind code fief. -19gmbet ' Nlemhei,fdem i T. �j5>k}.:.. %Im!]x 0 0 f10J 11 f715J� 4(12?T, ' F.':.(14 )' L1 ( : '1 HTU26 (Min.) 37/e (2) 2x! (10) 0.162x 3Yi (14) 0.148 x 1''A 925 1,470 1„909 no l' 5 j 795 1,265 1.430 ! 1,5�fi 1;=15 R U26 (Max.) 514 (2) 2x4 (10) 0.162 x 3'k (20) 0.140 x 1'k 1.241 1470 1 1560 1 1.700 1 2,220 105 1,265 1,430 1,541 910 IBC. I FL LA 1IT17�B' Max) t 7�la �' ?(� 2i ',j2 , 62r'd�/zj'101�8 1° ( x'�4ii32 -+ _3,�9�c"c,050.'. i _ :1t''r.• r - &380.: }hT1721Q`(M g�°.,,r:.2>S6.(?0)j178?o-8'fz•f�`'�U145.1'h.,fi.4L`.,2?g=:;.R9q`23'7.§:;?,53U<,?v°5•;'3.030_.;3,360. .._.. 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 'A".3. % nd (160) is a download rating. 4. Fasteners: Mal dimensions in the table are listed diameter by length. See pp. 21 22 for fastener Information. Alternative Allowable Loads (1/2r Maximum Hanger Gap) :�° :=�,' • ^'ea`lori in�r - :s6aSte4ers"in�*�;..,�'�'`''AflSPAnoVvh16,1b'�s= ( •I_ � �' � W.... _SpFIR�Al141�abtelvpds•:.L . `Nlin.:'Dim . $, ..S .:...r •,�=•M &.r - -- - �..,;. � : ; UOlifl:.' Flood _ :StiSyr - -Roof ..•WN$. - . Gode Ref.Ii S� �;yh( .W;i:'•.H`: : ,•..•;ti.. 1. The maximum hanger gap is measured between the joist (or truss) and and the carrying member. 2. lAnimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Upfift loads have been Increased for earthquaYme or wand loading with no further increase alloyed. Reduce where other loads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between W and Ya', use the Alternate Allowable Loads 6. Truss chord cross -gran tension may limit allowable bads in accordance .with ANSVIPI 1-2014. Simpson Strong Tie° Connector SeLdor'sofmiare includes the evaluation of cross -grain fersien in its hangar allowable Icads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148' x 1'IR nails in the header and reduce the aibwable download to 0.70 of the table value. The a0rnroable uplift is 10045 of the table load. B. Fasteners: Nall dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener Information. a 197 Simpson Strong -Tie=' 1•Nocd Construction Connectors SIMP$ON ■ti Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wail as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUG products are heavy-duty face-moune Joist hangers made from 14-gauge galvanized steel. • The HUG is a concealed flange (face flanges turned in) version of the HU. • HU is available with both tanges concealed, provided the W dimension is 2?16' or greater, at 100% of the table load. Specify HUG, • HU is available with one flange concealed when the W dimension is less than 2-A at 100% of the table load. Specify as an W version and specify flange to conceal. • For any HU or HUG shown in this catalog, the user may substitute all face nails with Ye" x 1 ye Tdene 2 screws (Model TTN2-25134H) for concrete and'rl x 2-Y4' Titen 2 screws !,t•AodelTW-°5234" for GFCMU. Follow all installation instructions and use the loads from the sawn lumber or B VP-ect1L,)ns: Material:14 gauge Finish: Galvanized; ZMA)(1 and stainless steel available Installation: • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU CA" x 25/' — Model TTN2-252344 and for concrete ('/a° x 1W — Model TTN2-25134H) are not provided with the hangers. - Drill the Vie -diameter hole to the specified embedment depth plus W. • Alternatively, drill the %e-diameter hole to the specified embedment depth and blow it dean using compressed air. • Cautlon: Overs zed-dameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Tden installation Tool 1Gts are available. They include a Tie dell bit and hex -head driver bit (Model TTNT01-RC); a Ma r. 4Ye" WE bit is also avaiabla (Model MDB18412). • A minimum edge distance of 1 Ya" and minimum end distance of 37W is required as shown in Flgi:re 1 for full upli` load. • V4rsre nu upl'dl load is required, a rr nirrum end dislarr.:a of 1 `2' is P—Mltt d. Codes: See p.12 for Code Reference Key Chart Concealed flanges HUC410 HU214 Figure 1 — HUG410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 237 -sim"pson" strong'-Tie'_'46o"d Consir.uction Connectors HU/HUC/HSUR/L Medium -Duty Face -Mount Hangers (cont.) 0 These Products Pre mailable wfh additional corrosion protecHon. For more informarlon, see p. 15. 'qp; 1-19f.1n, A� Co im ft - IND. HU26 HU2f3X (4) A X 2% 1 (4) 1,14 1114 1 (2) 0.148 X 1 Yx _ELI 1.000 .335 1 .545 . 4 L HU24-2 HUC24-2 (4) 'A x 2-Y� (4) 15 x 1% 1 (2) 0.148 x 3 3BO 1,000 380 1.545 A 7C3 J HU26-3,nlAn) HUG26-3 CAM.) (8) IA X 2:144 (8)ylx1Yl (4) 0.148 X 3 760 i 2.000 760 ^ 3.200 HU26-3 (Max.) HUG26-3 (Max.) (12) V, x 2-Y, (12) V4 x 1 -Y4 0.146 X 3 1,135 3.000 1 1.135 3.950 1 �i Alh 0, HU210 Huziox (9) l/. X 2.% (8) Y4 x 11,14 (4) 0.148 x 1 h 545 2,000 760 2,415 U, HU210-3 (Min,) HUC210-3(MIIQ 0'-'%X2:Y. (14)V&%l'1,' (6) 0.148 X 3 1,135 1 3,500 1335 1 4,920 4' (Max.)') (Max.) (18) 114 X ZY, 1,1 B) V, X I Y. C-.D)O.l48x3 1,800 4.500 1.800 1 5,085 Onj tHU21M'UC210-3 U HI 1912-2 (Mina HUG212-2 (Min.) (1 6) Y. x 2Y. ;16) 'A X VA (6) 0.148 X 3 1,135 1 4,000 1,135 1 4,920 HU212-2 (Max.) HUC212-2 (Max.) (2.2) IA X Z:K- (2ZI 'A x 1% (10)0.148x3 1.350 5,Da5 1.350 1 5,085 HU214 HU214X (12) 11', X 21/4 (12) 1/4 x 11/4 (6) 0.148 X 114 1.135 2.665 1.135 2465 HU214-3 (Min.) HUC214-3 (Min.1 8) '/4 X 23/4 (18) '/4 X 134 0.148 x 3 1,515 4.500 1,515 5,085 1`11.1214-21(MaL) I lil.113214-3iMax.) I (24)V4x2'A I (24)Y4xly- I 112)U3413XS I ZM o,uaa 1 HU216-2 (Min.) HUC2.16-2 (hTa) (20) 114 x 2-/4 (20) Y4 X 1 V4 (8) 0.148 x 3 1,515 4.920 1.515 4,920 HU216-2 (Max.) RUG2115-2 (Max.) (2 B) 1,14 x 23/4 (26) %x 1;11. (.12)0.148x3 1 2,U15 5,085 1 2015 5.085 'Ji 238 STAGGER JOINTS - TYP.T d� N UPLIFT/SHEAR ANCHOR — EACH TRUSS - SEE PLAN FAW Mll II_'�'-i'Il-IIIIIIIIIIIIII/i'Illll� rNOTEI ADD L FRAMING NOT I SHOWN FOR CLARITY RAISED HEEL TRUS5 BEARINGS/ A 1 VALEMS 1121VI RAISED HEEL ROOF TRUSSES AN IBBON BOARD- SEE -HEDULE FOR SPACING 4 SSTENWG TO TRU55E5 -MASONRY WALL - SEE PLAN ROOF SHEATHING- SEE SOFFIT(FASCIA- SEE RIBBON BOARD-- • . SEE SCHEDULE FOR SPACING 4 FASTENING TO u TRUSSES WALL SHEATHNG-BEE PLAN — MIN. 15/32' COX PLYW70D OR T/IS' 055 WITH ad GUN NAILS (0131' X 2 112'J a b' O.C. TO RIBBON BOARDS DO NOT FASTEN RIBBON BOARD — INTO END GRAIN OF ROOF TRU55 BOTTOM CHORD RAISED HEEL ROOF TR15SE6 -SEE PLAN UPLIFT15FIEAR `GYP. CEILWG- ANCHOR EACH SEE PLAN TRU55- SEE RAN SCHEDULE MASONRY.WALL SEE PLAN RAISED HEEL TRU55 BEARING/ B ecwz HTs SKI RIBBON SCHEDULE DESIGN CRITERIA RIBBON MATERIAL RIBBON SPACING RIBBON ATTAC .IMENT WIl•165 MPH (2) 12d GIN (0.131')( 3') (vaed-125 MPH) 2X4 6PF-2 24' TO EACH TRUSS, (4) EXP. B, NAILS AT JOINTS ENCLOSED_ WIL+ISO MPH (2)12d GLN (0.131' X 3') (vaed•13S MPH) 2X4 SPF4 IS' TO EACH TRUSS, (4J EXP. C. NAILS AT JOINTS ENCLOSED SHM mie SK.1 Plggyback Detail - ASCE 7-101 180 mph, 30" Mean Hgt, Partially Enclosed, Exp, C, Kzt=1,00 180 mph Wind, 30.00 ft Mean Hgt, ASCE 7-10, Part. Enclosed Bldg, Located anywhere In roof, Exp C, Wind DLm 5.0 psf <min), Kzt-1.0. Or 160 mph wind, 30.00 ft Mean Hgt, ASCE 7-10, Part, Enclosed Bldg. Located anywhere In roof, Exp D, wind DL- 5.0 psf (min), Kzt=1.0. Note, Top chords of trusses supporting piggyback cap trusses must be adequately braced by sheathing or purllns. The building Engineer of Record shall provide diagonal bracing or any other suitable anchorage to permanently restrain purllns, and lateral bracing for out of plane loads over gable ends. Maxlmum truss spacing Is 24' o.c. detail Is not applicable IF cap supports additional loads such as cupola, steeple, chimney or, drag strut loads. Piggyback cap truss slant nailed to all top chord purlin ++ Flat tap chord purllns required at both ends and at a maximum bracing with (2) 16d box nalls (0135'x3.51) and secure top of 24' Intervals unless otherwise noted an base truss design chord with 2x4 N3 grade scab (1 side only at each end) drawing. Attach purlln bracing to the flat top chord using a attached with 2 rows of lOd box malls (0,128141) at 4' o.c. minimum of (2) 16d box malls (M135N3.5'), 12 V Flat Top Chord <= 36' x In addition, provide connection with one of the fallowing methods, Trulox 28PB Wave Piggyback Plate _ Use 3X8 Trulox plates far 2x4 chord member, and One 28PB wave piggyback plate to each face 3X10 Trulox plates for 2x6 and larger chard lag' a Att h teeth to pis back at tlm of €tach to ng truss wi h members. Attach to each Face fl 8' o,c with <4) 0,120'xl.375' malls Into cap bottom chord and (4) fnbrlco, Ion. supfpo <4) 0.120'x1.375' malls per ace per In base truss top chard. Trulox plates may be Piggyback plates may be staggered 4 o.c. front staggered 4' o.c. front to back faces, to ack faces. APA Rated Gusset e'x8'x7/16' (min) APA rated sheathin0 Gussets 2x4 Vertical Scabs 2x4 SPF N2, full chord depth scabs (each face). (6) 10d box (0.128'x3'), (each face). Attach B 8' o.a with <B) 6d coFlnon (4) bottom Attach @ 8' a.c. with naps (3) In bottom chord and (3) In (p,113'x2') malls per gusset, n cap and (4) In base truss top chord. Gussets Ear scab, cap ase truss top chord. Scabs may be staggered chord may be staggered 4' o.c. front to back faces. 4' aG front to back faces. vaa S n °&L REF PIGGYBACK CENFr�RACTTIIMS nePORTANTes FUMM THIS �vANOW m MUDINc VC VISTALLBxxs Trusses reWlre eXtr.ne corn h rahrlanttrq, hondlhg, "pl hrtolWp and hradt@y ReFer to and fetoe the latest rdtlon of DCSI (BUIding Component SAFety InVPornatlon, y TPI end SHCAI For safety DATE 10/01/14 DRWG PB180101014 vvroctices prior to p-Fornhg these functions, Inetellere shot( provide temporary bradrg per HCIL top chord ]halt hove Properly attached structural ahea hg Orl otton dlard ft �� d II ON UMe" noted othrrelpe, shall have a properly attached Add coing. Locations shorn for Parnonent lateral natralnt of nbs shaU have troutY hstalltd Per Brit aactloro HB, H7 or 81a. as oPVBcahle. APPIy plates to each Pacr of tnua and posltbn os ahosn above ond an tM Jalnt D,AaU, unless noted a h .. se. Wee to d- I6CA-L Fr atond-d plate Posttiaru. , AN Ii1NODMPANy a. Alpine, a dvlslon, of ITV VAdIny conponento tY•oup Inc. shop mat be n]pm�hle Por any d,A.4b. Frpn this drawing, any Folk— to bull the truss h can orrgnce rlifi ANSI/TPL 1, ar for hnn g, shbP,ng. hstollatbn l bndng aP trusses. A seat an the droshhg or rover pop Ust►g JWs d'eshW hdkaMs acceptance of profesriwl mokaer%,a -b sty Far the dF" shoes TM eJbj*ty and we of Ws draehg AI✓st/fPI ! Ser-P SPACING 24.0 13388 Lake front Ddva For an_ str++y cwv Ip <ha nWpne tY of fhe DMdinO IMslP�ee' Wr For more hPornntian see this Joh's general notra ppoor and Wese eeb dfen EaM CI,y,Mo a3a46 ALPWD wealphdtesaN TPH sre.tphstar9l SHW ter dtdnduab..,!, ICO enlCaeoPe,o,g e • 11 i�bter.fiop' irhproJs `ciF•.• rCisses s..uppartltlg �lpgYloack' cup; tl;us gg; rltast_.be'aclequdtely. brtiSed, pyighe'a'thing br pi1N(ins,' The:bullding E, fneer• of'' kecArd, shall peaYlde dlagon'al brgcing'oh';;ariy other su Eable andhorage td perringgnt(y Meatr;.alri purllnsz'and-fateral bracing for. out of plane Wai s b?✓er gable ends, :Refgr to.EhOlmebrl 'seated trlis$. fbr•plggybeck,:af.d base tNss'spcC Catlons, &Amtum."'bass -i;Pkrhe• Is 14' d,di De.tdll' Is, no.t applld4ke. If •tqp., supporjs' dddltfdnal ;loads such 'as' cupola; gt6eplgi -chl�ney, on' S1i^pg strut load%- x .2x4,2x6+2itB,Ex10 or 2x1` y :Ifs: or !f2 ,f'T, SPF, .Her1= . r"'., +k Detall :ygllcl. only .pph PL(ll • overlap. -of plggYback chord ns sho}Yrt, or SP. as neeHed, A.ttadh' Vc6b ':to one ,fc[e of :truss: with 16c{'C0,151"K3;$►>:cprnMon;palls. pr 0,12fl x3' gun nallsl + d-ontln'uoue Laternl' Brodln*d'. CLH) ns• Qelffed 'on..:�he st�pppor lug' I truss ITWBGC. drawln0' or. a� 2 E_.r�;c; It n. t s ealPled, A'ttacFi.':to throdbhoUt top Q�i i-d,.' �' eaph supppl^tingg trusg'wlth d2) IOU <0,1$2 x3.5P7. cohhipn palls; mx Plggybeck `nS 'peh ' ITWBCG dngwfng At Each' to• , op chord, ,of ar^acln@ :Platerlal to bie supplletl qn( ut nche'd at; both. QnCis, •to 'suppontlljg.,truss 4sing el#hew the.,attachrien gpeclflec! lop a. �u►•table support by ergotlon contractor, :Alpine drgWlri 'or .4tlthi', .gWn nulls% (g,131tx3'g*-. hdlll'sY,.d.. r� 8 : oe� .for A. CE •7-IId,• .i� . rtphi Ene Efdg,. ' xp -8 & ,C;;130 H t 'CI,B. (4Adberl:�C4• arX�' #2 or U2 .FTI. SPFr, en -Flu; {tih .SP,. oc f6, :1'80 rlph, ;par't. Enq:'Eldg,.' Xp Br;'.30 MH• "CLB hay be! ,'appplled. td tPp edge, of supp4lf trg truss 'top 6�'• oG;. for A CE .7^16t .ieq nph, Ene, Bldp,. EX '..C, 8.0' MH �bQrd, (as. shcsyrn? or }�o tbM :edge oP' suppartlhg truss g •oc,• .fioW ,FISGE 7-16, •480 'Mph,• •Part; Enc, •Bldg, . xp C,•; 3D' MH top chord, wk, Toenail ,blugk 'Ep op`chord :WR o,128'x3' Gun'1 units @ 41' bq-,fogm gall•'face thrgughout, rtop •GhorO, 24. Max,. •_ ' • ..RIg9Yb¢eft. T.russ.. �!E �lE•�lE 1.1-1%41 frfaxr E $yogr'tlhj Trui$. t�tilt 61�y_ ...1 Top Chord :Blo.4[t heirkll `6'.�1C' N'SF'�,d�" r . - 'a "Vil me ,� -AND.rnu nv Ili 1p pus > rlAvma:.. I w : SGF1'B rt*A+ ruRrasr♦ nss mevrHc m u.u.. p�cwrmMs n+c.rar �F` PI�GI'�i�CK 'xiytiliei yy..��gulrtxaitt'iK.;chri'yrd'ab'fIC� ' .F`wM. Ns ond.tra Ra1•r'.io:er�i' ,' : ;y: _j_, �s. '•,w. A'f` 111/Q�/2D1B, /oli .. 1h• kSeirt ,Iriilon•ve ays �n6 nb:;sni Jay ornagonr tPl�ena` 10•fan.'ear ai., �. n4tlel4 (!h`ie•Wrq' {Ir'IUNc?rrt. IiMi6litr't „i�l'IA•u.P'eS.rl�• br'N _ ' i •� r. y rio4d otki'+l n op r>wrd. �hal�haw. tK rty atfarhid.ytry�grpl.shea to Z t Df21hIG P$SGAB'16.(j118 ,harf V: a,pr6parlY at 94r?•C.r FMaea"ians iw.wh•1o{'perr+o,4frli la NMI 1� .I'i.�W�f`•D9,. 7Iw as.'W. .; ,+WPI ''Pr4Ch►"`F"' .... S7'ATG. • t-44o/ s••oNi bn. , •ho,r,l• ,a{Id-i,rl'thr D• l; ii{rl}d'b rMai �• !' R.far- jd.tra a;rof Z.ftti a1o;ylQip Wna,:P?•� .. ®... '^ �Ww1.:�Frl�r1 0+ m� mkt y corlpon.df::Q�y� rnc'Nuul itiijt-w.r.:paei�tF.egf diWi i.. a' CORV �:� ®kWr dra .. ' fW. ffaN'w ie aWtd tha irurs 1n"f6nYoriairc. dHl •y1SVtPt 1, or• ian•hard . yy?.'f1 t4 1 5�J PSF AN1fWtOMhANY Y,itagatf '.V'l p�;fiur•�y r ;M1 ,. MAXI TC1T. • A'"" M .Vf +}SW& or Pap� 'H+Ff`d++.Nbi,Ndcn9+r`}tuPf•nv or. profNl.igrnl � t: ��• .. .aiA,eal(h>:I s' r•acwn N ar'tfl.' and 1 G r :� 1 suue xes • n v e'o�o►x�"�`„,''»r.uly. c:'�o�m'rtc Y.�a `M°.N° �!rr�l�r� N[A:� l Dt7(' F. Eurlh'CIIY,'1,1067045' For ryonR'NIq��1¢•jloNalf'Ljtlp,jol+�i'tl•�•ral.:P1QtM•�''Mf4�1"S.r'Wf Y11ik.Grlo/I•arQ�•... ALPIHEI mdWN.tf,Y,tlrnl TPor nw. .torOY•18CN•nM•. r-4 b I .oL, A AV TWIN;". & .000 -N vs 1: r . nd,� .4 ;+.J -.1 ......... 6 itp IN :14M i-C qs`o -OLA lo. ........... Q .,4 .4-9. q :PA, NPIM 14 , q . :., " ,.L -A ,u J4 ;9,x p. im PJU TO Vtd &q'=.j.(j '.0.: pUIA ...''v TWIN c 1. A 90—L-33S. Li �3 ;'P -d- .0 !� . d 1Q: N:d,H �l:::n: 3 ... ... ......... ......... .......... .. 6 liht ......... RE :m-,Uri iL p, Y.v -g`b iCilecl ' .. , -a- pq m ohmmtq Y-w . pxlhoIQ P� 5.i l0 Pof, ......... -Um:- i .5P -Cl.. 5: qp N 0. 61 e: an em. Vovi.offi! NOY. wd . oce. ....."a 41. IU61 ib-650": Mlh 'l ... Q5. Wr5....h.IVM p ,5:. : 'NO75 4a IS th.'h�H, L-, ORu Q_0flgr, -1 a-t .t., ::up Ths document has boon dectonicalty signed Alpine, an ITW Company and seated using e Digital SgnoWre.PhIftd 6750 Forum Drive, Suite 305 copies MfttA w ongfind signa!uro nwst be Orlando, FL 32821 verified using to ojigfW ele(:Ironic voirsion. Phone: (800)755-6001 ALPINE www.alpineltw.com AN iTw CompANY H COA #0 278 10/2912021 Al Customer Carpenter Contractors of America Job Number., N334504 Job Description 7A5/320,182ED, F 02G RIO 1 1 18281CALIMEBB ELEV.D/F Address., Design Code: FBC; 7th Ed. 2020 Res. IntelliVIEW Version: 20.02,OOA JRef#.- IXal89750114, Wind Standard: ASCE 7-16 Wind Speed (mph): 160 Design Loading (pso-- 37.00 Building Type: Closed This package contains general notes pages, 29 truss drawing(s) and 5 detail(s). Item Drawing 1VuPnber Truss 1 301,21.1607.51461 Al 3 301.21.1607.53024 A3 5 301.21.1607.51102 A4 7 30111.1607.52165 A6 9 301,21.1607.52821 A10 11 301.21.1607.52805 A14G 13 301.21.1607.53102 B2GE 15 30121,1607.52978 C2GE 17 301,21.1607.53166 D2 19, 301.21,1607.52900 V4 21 301;21.1607-52696 EJ7 '23 301.21.1607.53212 EJ3 25 301.21.1607.53213 CJ5 27 301.21.1607.53071 CJ1 29 301.21.1607,53009 HJ3A 31 GBLLETIN01 18 33 VAI-180160118 Itenri DraWingk T ruts 2 30121,160T52618 AM 4 301.21.1607.52041 A2 6 301.21.1607.53010 A5GE 8 301.21.1607.50899 A8 10 301.21.1607.52211 Al2 12 301 1 21.1607.51602 B1 14 301.21 . 1607.51680 C1 16 30111.1607.53274 D1 18 301.21.1607.53322 D3G 20 301.21.1607.53384 V8 22 301.21,1607.53181 EJ7A 24 301.21.1607.51352 EJ2 26 301.21.1607.53227 CJ3 28 301;21.1607.52743 HJ7 30 A1601 5ENC1 60118 32 CNNAILSP1014 34 VALTN 160118 Florida Certificate of Product Approval'#FL1 999 Printed 10/28/2021 4-49-52 PM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or 1310 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www. icc-es. org. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2of3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com. Page 3 of 3 SEQN: 250001 ! COMN Ply: 1 Job Number: N334504 �Cust:R8975 JRef:1Xa189750114 T10 FROM: RWM Oty: 16 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.51461 Truss Label: Al KD / FV 10/28/2021 6'1"7 12'11"15 19'10" 26'8"1 33'6"9 39'8" i 6'1"7 6'10"8 -}- 6'10"1 "r' 6'10"1"7 in 0 73 �,1 10'0 1' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 it Loc. from endwall: not in 9.00 it GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.1280" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 5X5 E 39,8" 9110" 9110" i 10' 1' 19,10" + 29'8" 39'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.222 K 999 240 Loc R+ / R- / Rh / Rw / U / RL Lu: NA Cs: NA VERT(CL): 0.385 K 999 240 B 1711 /_ /_ /961 /309 /444 Snow Duration: NA HORZ(LL): 0.081 J - - H 1711 A /- /961 /309 /- HORZ(TL): 0.140 J Wind reactions based on MWFRS Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 2.0 FBC 7th Ed. 2020 Res. Max TC CSI: 0.617 H Brg Width = 8.0 Min Req = 2.0 TPI Std: 2014 Max BC CSI: 0.882 Bearings B & H are a rigid surface. Rep Fac: Yes Max Web CSI: 0.457 Bearings B & H require a seat plate. Members not listed have forces less than 375# FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. WAVE VIEW Ver: 20.02.00A.1020.20 B - C 1490 - 3155 E - F 1130 - 2029 C - D 1366 - 2875 F - G 1366 - 2875 D - E 1130 - 2029 G - H 1490 - 3155 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2759 -1207 K - J 2278 - 858 L - K 2278 - 879 J- H 2759 -1186 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 541 -134 K - F 530 - 745 D - K 530 - 745 F - J 541 -134 E - K 1362 - 605 �tptiO4tt1t8dfrary rf t a aw � o. i08 1 _ a e a � a �+ d r v COA t f 8 N L 10/29/2021 *WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building nent Safety Information, by TPI an c7 SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. 5per BCSI. Unless noted otherwise, top chord shall have propedy attached structural sheathing and bottom chord shall have a properly tl rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, 15b ie. Apply plates to each face of truss and position as shown above and on the Join�Details, unless noted otherwise. kefer to Is 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. a division of ITW BuildincL Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the conformance with ANSI/TPI 1, or for handling, shipping,. Installation. and bracingof trusses. A seal on this drawn or cover pac1e "is drawint indicates acceptance of professional engineering responslbilitYy solelyor the design shown. The suitability and use of This 1 for any s ructure is the responsibility of the Building -Designer per ANSI/51 1 Sec.2. AL NE ANI COWAW 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250030 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T25 ! FROM: ALS Qty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52618 Truss Label: AlA �TCE / YK 10/28/2021 T11"2 T11"2 12' 17'1"12 19'10" 23'8" 31'8"14 4'0"14 S'1"12 2'8"4-I— 3'10" 8'0"14 =-6X6 F 39'8" 39'8" 7-11"2 39"3 2'11 3' 6'8" i 8'0"11 T11"5 i 1' F 8'1"1 11'10"4+ 14'� 17' + 23'8" 31'8"11 + Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: If EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T1 2x4 SP #1; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; W3,W6,W9,W11 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Plating Notes All plates are 2X4 except as noted. (1) - plates so marked were sized using 0% Fabrication Tolerance, 0 degrees Rotational Tolerance, and/or zero Positioning Tolerance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. * The 5-0-0 section of Bottom Chord at 8-8-0 elevation between panel points R and N may be field -removed as required provided that all remaining plate/wood contact areas stay intact and undisturbed. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.386 O 999 240 VERT(CL): 0.669 O 706 240 HORZ(LL): 0.168 K - - HORZ(TL): 0.314 K Creep Factor: 2.0 Max TC CSI: 0.791 Max BC CSI: 0.896 Max Web CSI: 0.765 VE. HS VIEW Ver: 20.02.00A.1020.20 Laterally brace Bottom Chord above filler at 24" oc, including a lateral brace at chord ends (Not required if 5-0-0 section of lower Bottom Chord is removed as noted (*)). OQ ae a✓ o� % s" m I o* e ya lip COA � � AIL 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /961 /309 /444 1 1556 /- /- /961 /309 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.2 1 Brg Width = 8.0 Min Req = 2.2 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1410 - 2745 F - G 1410 - 2068 C - D 2144 - 4245 G - H 1218 - 2103 D - E 1499 - 2794 H - 1 1423 - 2777 E - F 1658 - 2771 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2371 -1107 L - K 2402 -1107 Q - M 3738 -1614 K - 1 2406 -1106 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - S 814 -1523 M - F 2007 -1008 C - Q 1476 - 551 M - L 1864 - 604 S - Q 2850 -1327 F - L 492 - 506 Q - D 1271 - 562 L - G 452 - 368 D - M 825 -1539 L - H 475 - 688 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face off truss and position as shown above and on the Join Details, unless noted otherwise. Pefer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not, be responsible for any deviation from this drawing, any, failure to build the ANrtwcounNr truss in conformance with ANSI 1, or for handling, shipping,, Installation. and bracin of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engqlneenng responsibility solely -for the design shown. The suitability and use of This Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/T�1 1 Sec.2. For rnore information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcinduslry.com; ICC: iccsafe.org; AWC: awc.org Odando FL, 32821 SEQN: 250031 / FROM: RWM Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " COMN Ply: 1 Qty: 1 6'1"7 6'17 �110, 10, Job Number: N334504 ,7A5/320 ,182ED,F ,02G ,R101 ! 1828/CALI/4EBB ELEV.D/F Truss Label: A3 12'11"15 19'10" 24'4" 6'10"8 6'10"1 =5X5 E Wind Criteria Wind Sid: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; 133,134 2x4 SP #2 N; Webs: 2x4 SP #3; W3,W4,W5,W7 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 83 1114X4 Cust:R8975 JRef:1Xa189750114 T2 / DrwNo: 301.21.1607.53024 / YK 10/2812021 33'6"9 39'8" 9'79 1—o 20'8" 5'8" 13,4" 910 4'6" 5'4" 10, F1'� 19,10" 24'4' 39'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or `=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.033 M 999 240 Loc R+ / R- / Rh / Rw / U / RL B 871 /_ /_ 1610 /172 /444 Lu: NA Cs: NA VERT(CL): 0.082 M 999 240 Snow Duration: NA HORZ(LL): 0.011 L - - N' 247 /- /- /156 /73 /- HORZ(TL): 0.024 C Creep Factor: 2.0 H 508 /- /- /427 /147 /- Wind reactions based on MWFRS Building Code: FBC 7th Ed. 2020 Res. Max TC CSI: 0.961 B Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.737 N Brg Width = 68.0 Min Req = - H Brg Width = 8.0 Min Req = 1.5 Rep Fac: Yes Max Web CSI: 0.420 Bearings B, N. & H are a rigid surface. FT/RT:20(0)/10(0) Bearings B & H require a seat plate. Plate Type(s): Members not listed have forces less than 375# VIEW Ver: 20.02.00A.1020.20 WAVE Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 606 -1330 G - H 246 - 579 C - D 479 -1037 ♦rlGE NS r 9 10/29/2021 Fl Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - M 1138 - 532 K - J 952 - 498 M - L 691 - 320 J - H 484 -143 L-K 967 -518 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - M 375 - 360 K - F 885 - 1188 M - D 558 -150 F - J 573 - 255 D - L 559 - 715 J - G 495 - 484 L - F 769 - 272 `*WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT'" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an q SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joi ,PDetails, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be resp. onsible for any deviation from this drawing, any failure to build the MMCQa truss in conformance with ANSI/ -I PI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawln or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en lneering responsibility solely -for the design shown. The suitabilify and use of fhis Suite 305 drawing for any structure is the responsibility of the BuildingUesigner per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEON: 1072 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T9 / FROM: HMT city: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52041 Truss Label: A2 KD / WHK 10/281202' 12'6"15 336"9 19' 118239'8" s5X5=5X5 E F 39'8" 1' i 10' 9'10" 9.10" 10' 1' T 10' + 19,10" + 29'8" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.172 L 999 240 VERT(CL): 0.321 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.123 K Creep Factor: 2.0 Max TC CSI: 0.480 Max BC CSI: 0.747 Max Web CSI: 0.625 EW Ver: 20.02.00A.1020.20 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- ! Rh / Rw / U / RL B 1556 /- /- /963 /310 /427 1 1556 /- /- /963 /310 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1542 - 2800 F - G 1182 -1779 C - D 1425 - 2521 G - H 1425 - 2521 D - E 1182 -1779 H - 1 1542 - 2800 E - F 1159 -1559 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2444 -1262 L - K 2030 - 937 M - L 2030 - 957 K - 1 2444 -1241 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 508 -119 L - F 548 - 356 tiggtRtataldrAi/1ilerrttlf D - L 548 - 356 G - K 508 _ 119 r°rrr,. r ��b� �aauaao•®a.s � r�4 P s � o s s � s �r ®®�00►MOPmpg \Is� `�� 10/29/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have ropey attached structural sheathing and bottom chord shall have a properly attache. rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face. of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinIComponents Group Inc. shall not,be responsible for any deviation from this drawing, any.failure to build the AsrtwcoMaArry truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation, and bracin4 of trusses. A seal on this drawn or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitability and use of This Suite 305 drawing for any s ructure is the responsibility of the Building -Designer per ANSI/TP1 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 1074 / HIPS Ply: 1 Jab Number: N334504 Cust: R8975 JRef:1Xa189750114 T8 I FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.51102 Truss Label: A4 KD / WHK 10/28/2021 b ro 73 7'10"14 17' 22'8" 31'9"2 39'8" 7'10"14 9' 1 "2 5'8" 9' 1 "2 T1014 �1'+ 10. 10. Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. .5X5 =5X5 D E 39'8" 9'10" 19'10" 29'8" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.149 J 999 240 VERT(CL): 0.279 J 999 240 HORZ(LL): 0.060 1 - - HORZ(TL): 0.112 1 Creep Factor: 2.0 Max TC CSI: 0.760 Max BC CSI: 0.755 Max Web CSI: 0.989 Ve r: 20.02.00A.1020.20 `tom", � r'rrfi \ �®R•O4•p F� 0 d, 0 • o.708 9 v e 0 S �a }� �{ 0 Pi ` 0 bY• ,{may,•, �y •� J� Dp q A ®�•*v®MCI gOa9*®Oo\ COA � il"ONA �¢a�aaast�eatt�ieal�a 10/29/2021 10, 1' 39'S"r ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1552 /- /- /965 /318 /386 G 1552 A /- /965 /318 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 G Brg Width = 8.0 Min Req = 1.8 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1673 - 2755 E - F 1699 - 2561 C - D 1698 - 2561 F - G 1674 - 2755 D - E 1352 -1728 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 2393 -1373 J - 1 1695 - 842 K - J 1695 - 863 I - G 2393 -1352 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 498 -448 E - I 770 -435 K - D 770 - 435 1 - F 498 - 448 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. App�y plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not,be resp, onsible for any deviation from this drawing, any, failure to build the ANMCOWV W truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this draw(np or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilityy solely -for the design shown. The suitabili y and use of This Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2500651 COMN Ply: 1 Job Number: N334504 Cust: R8975 JRef:1Xa189750114 T11 / FROM: RDP Qty: 1 7A51320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53010 Truss Label: A5GE / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: S7.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " �12'11J'15 Ay�11'4 62 2'3'15 1'4 1 .2 6'1'7 9'10' 1q'8' 260193206101 1'1 ' 2YT 5710"7 93 F391'"B1"4 ♦--1o's•'-�-I -5x8 K 21' i6' i 13'B" F7' I 10' + + 1'3i12 5 + 3'B• 3' + 7' �1'� 10' iB'B'4 21 26' 29'B' 32'B" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: 11 EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.97 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W7,W1 4,W1 5,W1 6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Special Loads ---(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -1.00 to 56 pit at 10.67 TC: From 76 plf at 10.67 to 76 plf at 32.67 TC: From 56 plf at 32.67 to 56 plf at 40.67 BC: From 20 plf at 0.00 to 20 plf at 39.67 BC: 128 lb Conc. Load at 23.21,23.79 PL: 136 lb Conc. Load at (23.27, 9.98), (23.80,9.98) Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 21'11.12 1 3'10-8 1 131X12 --{ Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl VERT(LL): 0.106 AE 999 VERT(CL): 0.211 AE 999 HORZ(LL): 0.044 1 HORZ(TL): 0.088 1 Creep Factor: 2.0 Max TC CSI: 0.646 Max BC CSI: 0.645 Max Web CSI: 0.957 ♦ Maximum Reactions (Ibs) L/# Gravity Non -Gravity 240 Loc R+ / R- / Rh / Rw / U / RL Ver: 20.02.00A.1020.20 #�V �k�i � .µs�soea& a° e o.708 in o oy g C0A4�$ 0A 10/29/2021 B 769 /- A /504 /323 1444 AB 2335 /- A 1945 /990 A Z 1079 /- /- /484 /352 A T 519 A /- /398 /219 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 AB Brg Width = 8.0 Min Req = 2.8 Z Brg Width = 8.0 Min Req = 1.5 T Brg Width = 8.0 Min Req = 1.5 Bearings B, AB, Z, & T are a rigid surface. Bearings B, AB, Z, & T require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 465 -1090 I - J 391 -195 C - D 335 - 815 J - K 390 -199 D - E 399 - 762 K - L 536 - 262 E - F 411 - 759 L - M 608 - 296 F - G 397 - 678 M - N 506 - 244 H - 1 377 -185 S - T 228 - 610 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B -AH 922 -479 AA- Z 375 -227 AH-AG 486 -261 Z-Y 388 -286 AG-AF 486 -261 Y-X 388 -286 AF-AE 486 -261 X - W 491 -156 AE-AD 486 -261 W - V 491 -156 AD -AC 486 -261 V - T 491 -156 AC -AB 479 -325 oA Maximum Web Forces Per Ply (Ibs) a Webs Tens.Comp. Webs Tens. Comp. ® AH-AI 518 -256 AB -AR 304 -482 ry 0 AI-AJ 555 -273 AR -AS 445 -568 .° AJ-G 519 -269 AW-Z 272 -747 +fief G -AL 514 - 933 AW- N 237 - 676 AL -AN 498 - 920 N -AX 683 - 357 �` AN -AP 519 -955 AX-X 690 -352 AP -AC 540 -984 X-AZ 301 -478 AC- K 792 -505 AZ -BB 275 -472 K -AB 546 -1366 BB- S 326 - 457 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicab-le. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinQQComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCOWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawingor cover pare 6750 Forum Drive listing this drawing indicates acceptance of professional enctineering responsibility solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Buildings esigner per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250035 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T7 / FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52165 Truss Label: A6 KID / WHK 10/28/2021 7'10"14 15, 24'8" 31'9"2 398" 1 7'10"14 } 7'1"2 9'8" { 7'1"2 7'10"14 :6X6 = 6X6 D T3 E 12 6 5 5X5 F C o_ c0 W co W1 B A H8'8" IIIG 4X6(A2) =5X5 =5X5 =5X5=4X6(A2) 39'8" 10' 9'10" i 9'10" i 10, �1'. 10' 19,10" 29'8" +1'� 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pfin PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.159 J 999 240 Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.298 J 999 240 B 1552 /- /- /962 /328 /346 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.061 1 - - G 1552 /- /- /962 /328 A EXP: C Kzt: NA HORZ TL 0.115 1 Des Ld: 37.00 ( ) Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TIC CSI: 0.913 G Br Width = 8.0 Min Re 1.8 g q = Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.760 Bearings B & G are rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.474 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ItFT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1807 - 2729 E - F 1827 - 2537 C - D 1826 - 2538 F - G 1807 - 2729 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; D - E 1539 -1910 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2363 -1483 J - 1 1847 -1110 member design. K - J 1847 -1131 I - G 2363 -1462 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 394 - 358 E - 1 628 - 300 K - D 628 - 300 1 - F 394 - 358 �y�t:s a a s u ups ruu tyro tF qq, Z. i GE s •q, `� a t � py e ® s s � � ss 0 a ®u•itrlpq®ae`�` kip°° COA1 ALtisao\ 10/29/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS shipping, Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r sa practices Prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$Components Group Inc. shall not. be responsible for any deviation from this drawing, any. failure to build the ANr COWAW tr ss in conformance with ANSI 1, or for handling, shipping,, Installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional en ineering responsibility solely -for the design shown. The suitability and use of This Suite Fos drawing for any sgructure is the responsibility of the Building -Designer per ANSINI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250036 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xal89750114 T6 / FROM: RWM Qly: 1 7A5/320 ,182ED,F ,02G ,Riot / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.50899 Truss Label: A8 KD / WHK 10/28/2021 6'9"4 13' 19,101, 26'8" 32'10"12 3. '&' f 6'9-A 6'2"12 6'10" 6'10" 6'2"12 6'9._ .5X5 III2X4 = 5X5 D E F 12 6 �2X4 W r, C 0 t24 W3 i— B H Tj 4X6(A2) = 5X5 = SX8 = 5X5 = 4X6(A2) 39'8" 10' 9'10" 91101. 10, 1 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pfin PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.191 E 999 240 Lac R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.357 E 999 240 B 1556 !- /- /953 f716 /305 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 !- /- /953 /716 /- EXP: C Kzt: NA TL : 0.121 J Wind reactions based on MWFRS Des Ld: 37.00 ( ) HORZBuilding Mean Height: 15.00 ft NCBCLL: 10.00 Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 FBC 7th Ed. 2020 Res. Max TC CSI: 0.543 H Brg Width = 8.0 Min Req = 1.8 psf Bearings B & H are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.754 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.687 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020:20 B - C 2014 -2780 E - F 1973 -2289 Lumber C - D 1925 - 2523 F - G 1925 - 2523 Top chord: 2x4 SP #2 N; D - E 1973 -2289 G - H 2O14 -2780 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2421 -1686 K - J 1982 -1323 member design. L - K 1982 -1344 J - H 2421 -1665 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 381 -339 K - F 425 -401 L- D 535 -183 F -J 535 -183 D - K 425 -401 J - G 381 - 339 Ott#i�asfutf(f#faajei��p{� E - K 585 -391 J~`i NO ��eam• oay{a$�a „ K o y � o a w o f ULi I a °' • s m t a m • .o 1,,V+`� COA �01YACCftfajyisniwi 10/29/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections 53, B7 or B10, as applicable. Apply to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to Oates drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW BuildingComponents Group Inc. shall not_be responsible for any deviation from this drawing, any. failure to build the AN WCOMCANV in with ANSI 1, for handling, bracin4of trusses. A on this drawing or cover a truss conformance or shipping,. installation and seal pa 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilityY solely -for the design shown. The suitability and use of This Suite 305 -Designer drawing for any structure is the responsibility of the Building per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or • SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250037 / HIPS Ply: 1 Job Number: N334504 Cusl: R 8975 JRef:1Xa189750114 T5 / FROM: RWM Qly: 1 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52821 Truss Label: A10 SSB / WHK 10/28/2021 5'919' 28'8" 33'10"12 39'8" 5'94 5'2"12 8' 9'8" 5'2"12 5'9"4 5 X 5 = 5X5 - 5X5 D E T3 F T 12 T 6 2X4 W 52 o C (a) (a) G C' n in W3 � � B 1 H A 1 1 = R 8'8" =4X6(A2) -5X5 =5X8 =5X5=4X6(A2) 39'8" 10' 9'10" 9.10" 10, 11� �1' 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.213 E 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.399 E 999 240 B 1556 /- /- /940 /718 /264 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 J - - H 1556 /- !- /940 /718 /- EXP: C Kzt: NA Des Ld: 37.00 ( )HORZTL: 0.127 J Wind reactions based on MWFRS Mean Height: 15.00 ft Building Code: Cree Factor: 2.0 NCBCLL: 10.00 g p B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.934 BCDL: 5.0 psf H Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Sid: 2014 Max BC CSI: 0.752 Bearings B & H are a rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.751 Members not listed have forces less than 375# FT/RT:20 0 /10 0 Loc. from endwall: not in 9.00 ft () () Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2194 -2804 E - F 2386 -2693 C - D 2057 - 2533 F - G 2066 - 2539 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; D - E 2502 - 2773 G - H 2184 - 2797 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1 X4 #3SRB or better continuous lateral restraint to B - L 2448 -1855 K - J 2163 -1578 be equally spaced. Attach with (2) 8d Box or Gun L - K 2147 -1575 J - H 2440 -1822 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs L - D 470 -71 K - F 626 -612 for (2) CLR'S where shown. Scab reinforcement to be D - K 739 -778 F - J 466 -52 same size, species, grade, and 80% length of web E - K 789 -534 member. Attach with 0.128x3" gun nails @ 6" oc. i99Jf plrlrag�s ���g8144sitP41 Wind �ti f�rr Wind loads based on MWFRS with additional C&Cti emxs�*"tlpaa �''Fi *rr member design. �b� s ss�� •°�>��j� Wind loading based on both gable and hip roof types. �e a ® o. p f,.it�T a e s " 4 G Q pqq spy ;pip] .+ I 4 �f 06 ® ��C ,}p�yag40Y*0ma@Pp®fly �g y $I h1 COA I D/29/2021 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWINGTOALL CONTRACTORS INCLUDING THE INSTALLERS Component Safety Information, fabricating, SBCAjnfor salfety perfrtorming these Instlallers shall practicesnp9ior to functions. Installers provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.. Refer to ALPINE Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOMPAW for handling, bracin4 trusses. A this drawing truss in conformance with ANSIIf PI 1, or shipping,. installation. and of seal on or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional encLrneenng responsibilitty�r solely -for the design shown. The suitability and use of this Suite 305 -Designer drawing for any sgructure is the responsibility of the Building per ANSI[TP1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250038 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T4 / FROM: RWM Qty: 1 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52211 Truss Label: Al2 KD / WHK 10/28/2021 9' 17' 30'8" 39'8" 9' 8' 5'8" 8' 9' ,6X6 =5X5 =4X4 =6X6 C T2 D E T3 F 12 6 T T o (a) W (a) W5 h � B N G 1 A H g—� 4X6(A2) = 6X6 = 6X6 = 6X6 = 4X6(A2) 39'8" 1' 10' 9'10" J. 9'10" 10, 1' 39'8" 10' 19,10" 29'8" Loading Criteria (psr) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.251 J 999 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.469 J 999 240 B 1556 /- J- /921 /720 /223 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.081 1 - - G 1556 /- /- /921 /720 P EXP: C Kzt: NA TL HORZ 0.150 1 Des Ld: 37.00 ( ) Wind reactions based on MWFRS Mean Height: 15.00 ft Building Code: Creep Factor: 2.0 NCBCLL: 00 p B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 000 FBC 7th Ed. 2020 Res. Max TC CSI: 0.939 . BCDL: 5.0 G Brg Width = 8.0 Min Req = 1.8 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.834 Bearings B & G are rigid surface. Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.306 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 B - C 2250 - 2705 E - F 2239 - 2478 Lumber C - D 2238 -2478 F - G 2250 -2704 Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N; D - E 2906 -3233 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W2,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint B - K 2330 -1856 J - 1 3176 - 2629 to be equally spaced. Attach with (2) 8d Box or Gun K - J 3174 - 2647 1- G 2329 -1835 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) C - K 718 -428 E - I 944 -834 scabs for (2) CLR'S where shown. Scab K - D 940 -832 1 - F 718 -430 reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gunggta§ykrn{98)lJilyr nails @ 6" oc. rr6r Wind,, Wind loads based on MWFRS with additional C&C�'. '!� ' member design. �� ®� o Wind loading based on both gable and hip roof types. °m $ «m M a z % 0 COA #it$ NA`�``�S(t�ba``` 10/29/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing Unless top have sheathing and bottom chord shall have a per BCSI. noted otherwise, chord shall properly attached structural attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracm installed per BCSI sections properly 63, B7 or 1310, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin$Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure A this draw(nq to build the AN WCOMPANY truss in conformance with ANSI 1, or for handling, shipping,, Installation. and bracing of trusses. seal on or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of en Ineenng responsibility solely for the design shown. The suitablli y and use of this professional drawing for any sQructure is the responsibility of the Buildinggesigner per ANSI/TPI 1 Sec.2. Suite 305 For more information see these web sites: Alpine: aI ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC:awc.orp Orlando FL, 32821 SEQN: 250056 / HIPS Ply: 2 Job Number: N334504 : R 8975 JRef:1Xa189750114 T12FROM: LPM Qty: 1 7A5/320 182ED,F 02G R101 / 1828/CALI/4EBB ELEV.D/F No: 301.21.1607.52805 rD Truss Label: A14G / WHK 10/28/2021 2 Complete Trusses Required 7' 17' 22'8" 32,8„ 39'8" 7' 10' 5'8" 10' 7' =6X6 =8X8 =8X8 =6X6 12 C T2 D T3 E T4 F T 6� T o B G A H 4X6(A1) =8X8 = 8X8 -8X8=4X6(A1) 39'8" 10' 9'10" 10, 1' T 10' 19'10„ i 29,8" 39,8„ Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) DefI1CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.295 J 999 240 Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.555 J 850 240 B 3135 /- /- /- /1427 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - G 3136 /- /- !- /1428 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.121 1 Wind reactions based on MWFRS Mean Height: 10.51 ft NCBCLL: 0.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf G Br Width = 8.0 Min Re 1.8 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.676 g q = Load Duration: 1.25 TPI Std: 2014 Max BC CSI: 0.507 Bearings B & G are i rigid surface. MWFRS Parallel Dist: 0 to h!2 Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: No Max Web CSI: 0.760 Members not listed have forces less than 375# Loc. from endwall: NA FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1424 - 3094 E - F 1534 - 3602 C - D 1533 - 3601 F - G 1425 - 3094 Top chord: 2x4 SP #2 N; T2,T4 2x6 SP SS; D - E 2128 -4831 T3 2x6 SP #2 N; Bot chord: 2x6 SP SS; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Nailnote B - K 2752 -1257 J - I 4769 - 2187 Nail Schedule:0.128"x3", min. nails K - J 4768 -2187 1 - G 2753 -1258 Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Maximum Web Forces Per Ply (Ibs) Use equal spacing between rows and stagger nails Webs Tens.Comp. Webs Tens. Comp. in each row to avoid splitting. C - K 1287 -417 E - I 727 -1297 Loading K - D 727 -1298 1 - F 1287 -417 #1 hip supports 7-0-0 jacks with no webs. �9tsfstrtur�tir�P 1 Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types.,�°e' ®+ o W � 0 � s ■ 80 9 0 a a `,t*q COA (iJ!!¢33Qi% r A� 10/29/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component fo'r Safety Information, by TPI and SBCA) safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI. Unless top have bottom have per noted otherwise, chord shall proper)Y attached structural sheathing and chord shall a properly attacheU rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. App�y plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildingq�Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANn CCWAW truss in conformance ANSI/TPI 1, for handling, bracin44 trusses. A this drawing with or shipping,, Installation and of seal on or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional en Ineering responsibilityty solely -for the design shown. The suitability and use of this Suite Fos drawing for is Building -Designer any structure the responsibility of the per ANSIfTP1 1 Sec.2. For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEON: 250039 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T20 I FROM: RWM Oly: 1 7A51320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.51602 Truss Label: B1 KD / WHK 10/28/2021 5'7"4 i 10,81, _ 15'812 21'4" i r 5'7"4 5'0"12 5'0"12 574 '7 P EO Lo 73 Loading Criteria (psq TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacinq: 24.0 " 8' Wind Criteria Wnd Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. =4X4 D Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 21'4" 5'4" 13'4" Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.047 H 999 240 VERT(CL): 0.088 H 999 240 HORZ(LL): 0.020 G - - HORZ(TL): 0.037 G Creep Factor: 2.0 Max TC CSI: 0.371 Max BC CSI: 0.611 Max Web CSI: 0.232 VIEW Ver: 20.02.00A.1020.20 .+-- -I•r'ttjl 1 pg-�rr r>. b� 08 yip ��yy-pppq$ �. Y ® C ° gVgy yp� O 4 COA L fVAl a�tatti3�t�uy*it 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 864 /- /- /529 /397 /229 F 805 /- /- /464 /361 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 F Brg Width = 8.0 Min Req = 1.5 Bearings B & F are a rigid surface. Bearings B & F require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-C 1190 -1344 D-E 1113 -1152 C-D 1104-1146 E-F 1201 -1351 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 1152 - 993 G - F 1161 - 955 H - G 795 - 539 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - H 471 - 284 D - G 394 - 335 H - D 383 - 322 G - E 479 - 289 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord shall have a properly attached n id ceilin Locations shown for ermanent lateral restraint olYwebs shall have bracin installed per BCSI sections B3, B7 or B10, as applicabgle. Applgy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the truss in conformance with ANSI PI 1, or for handling, shipping,. installation, and bracingof trusses. A seal on this drawing, or cover page listing this drawing indicates acceptance of professional engineering responsibilit�yy solelyor the design shown. The suitability and use of this drawing for any sgructure is the responsibility of the Buildingq esigner per ANSI/TPI 1 Sec.2. A P NE ANMCCWAW 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250059 / GABL Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xal89750114 T3 / FROM: HMT Qty: 1 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53102 Truss Label: 62GE / YK 10/28/2021 P Co P3 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 10'8" 10'8" I- 4,8„ 2' (TYP) =4X4 F Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 plf at 22.33 BC: From 20 plf at 0.00 to 20 plf at 21.33 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. WIND LOAD CASE MODIFIED! 21'4" 21,4" 21'4" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): WAVE 21'4" 10,8" Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.005 R 999 240 VERT(CL): 0.011 R 999 240 HORZ(LL): 0.004 L - - HORZ(TL): 0.006 R Creep Factor: 2.0 Max TC CSI: 0.323 Max BC CSI: 0.197 Max Web CSI: 0.091 EW Ver: 20.02.00A.1020.20 1$.ymi r } r Frv�r a x® r • ° • 10/29/2021 ♦ Maximum Reactions (lbs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B* 125 /- /- /39 /48 /11 Wind reactions based on MWFRS B Brg Width = 256 Min Req = - Bearing B is a rigid surface. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildinc Components Group Inc. shall not.be responsible for any deviation from this drawing, any, failure to build the pN 1WCOMFANV truss in conformance with ANSI 1, or for handling, shipping,. installation and bracing of trusses. A seal on this drawn or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional encLineering responsibili(t�� solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineilw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC'. awc.org Orlando FL, 32821 SEQN: 250041 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T19 / FROM: RWM Qly: 1 ,7A5/320 ,182ED,F ,02G ,Riot / 1828/CALI/4EBB ELEV.D/F Dnallo: 301.21.1607.51680 Truss Label: C1 KD / WHK 10/28/2021 7' 7' 5X5 C 14' 14' 7' 7' 7' 7' 14' Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.014 E 999 240 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.025 E 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.008 E - - Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.013 E Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft Creep Factor: 2.0 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.767 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.503 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.119 Loc. from endwall: Any FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): IVIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types A , \ ap�C600 g.qq 6_ �P ✓row e coAI`s��A1.a,,,4 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 588 A /- /371 /272 /158 D 527 A /- /305 /234 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 805 - 740 C - D 807 - 739 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - E 598 - 542 E - D 598 - 542 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have propgr attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply Oates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall notbe responsible for any deviation from this drawing, any failure to build the ANMCO-AW truss in conformance with ANSI/TPI 1, or for handling, shipping,i . nstallation and bracing of trusses. A seal on this drawln or cover pa a listing this drawing Indicates acceptance of professional en Inen eng responsibilitty�r solely -for the design shown. The suitability and use of this Suite 3o5 drawing for any structure is the responsibility of the Building�esigne6750 Forum Drive r per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPL tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 250061 / GABL Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T1 / FROM: RWM Qty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALIMEBB ELEV.D/F DrwNo: 301.21.1607.52978 Truss Label: C2GE / YK 10/26/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 SDacina: 24.0 " 7' 14' rL' 7, 7' i Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 96 plf at -1.00 to 96 plf at 15.00 BC: From 20 plf at 0.00 to 20 plf at 14.00 Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. WIND LOAD CASE MODIFIED! 5' 'i' 2' —' (TYP) =4X4 D 14' 14' 14' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/l 0(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl U# VERT(LL): 0.007 J 999 240 VERT(CL): 0.014 J 999 240 HORZ(LL): -0.004 H - - HORZ(TL): 0.009 H Creep Factor: 2.0 Max TC CSI: 0.392 Max BC CSI: 0.242 Max Web CSI: 0.142 ♦ Maximum Reactions (Ibs), or*=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B* 129 /- /- 140 /50 /12 Wind reactions based on MWFRS B Brg Width = 168 Min Req = - Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. C - D 376 -199 D - E 377 -199 VIEW Ver: 20.02.00A.1020.20 J Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 511 - 403 H - E 511 - 403 n°® 0.7108 O 0 tl tl � 0 0 tl*DBaM qq P6� V ��' COA`Xf 8,NAL 10/29/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildinq Components Group Inc. shall not. be resp. onsible for any deviation from this drawing, any, failure to build the ANMCOWP truss in conformance with ANSI/TPI 1, or for handling, shipping,. Installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional encLlneenng responsibilityy solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2500431 COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef.1Xa189750114 T13 ! FROM: LPM Qly: 1 ,7A5l320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53274 Truss Label: D1 KD / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; 5' 5' =4X4 C 10, 5' 12 6 c� B D 01 4 E 88 F 1112X4 2X4(A1)=2X4(A1) i Criteria I Std: ASCE 7-16 !d: 160 mph )sure: Closed Category: 11 C Kzt: NA 1 Height: 15.00 ft L: 4.2 psf L: 5.0 psf :RS Parallel Dist: 0 to h/2 Dist a: 3.00 ft from endwall: not in 4.50 ft GCpi: 0.18 Duration: 1.60 Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 10, 5' 5' Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): 5' 10, Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.007 F 999 240 VERT(CL): 0.013 F 999 240 HORZ(LL): 0.003 F - - HORZ(TL): 0.006 F Creep Factor: 2.0 Max TIC CSI: 0.345 Max BC CSI: 0.257 Max Web CSI: 0.081 VIEW Ver: 20.02.00A.1020.20 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 434 /- /- /286 /202 /134 D 434 /- /- /286 /202 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 522 - 494 C - D 521 - 494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 396 - 293 F - D 396 - 293 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatin , handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an � SBCA) r satPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310, as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the AN MCOMPANY truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation. and bracin4 of trusses. A seal on this drawing or cover pa 4e 6750 Forum Drive listing this drawing Indicates acceptance of professional enccLLsneering responsibilittyy solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSV41 1 Sec.2. For more information see these web sites: Alpine: al ineilw.com; TPI: t insl.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250044 / COMN Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T26 / FROM: LPM Qty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53166 Truss Label: D2 KD / YK 10/28/2021 5' 5' 4X4 C 10, 5' 12 6 ih B D in IBI 4 E 88' F 2X4(A1) 1112X4 = 2X4(A1) 10, 1 �f 5' 10, '� 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pfin PSF) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.007 F 999 240 VERT(CL): 0.013 F 999 240 HORZ(LL): 0.003 F - - HORZ(TL): 0.006 F Creep Factor: 2.0 Max TC CSI: 0.345 Max BC CSI: 0.257 Max Web CSI: 0.081 VIEW Ver: 20.02.00A.1020.20 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 434 /- /- /286 1202 /134 D 434 /- /- /286 /202 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 8.0 Min Req = 1.5 Bearings B & D are a rigid surface. Bearings B & D require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 522 - 494 C - D 521 - 494 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - F 396 - 293 F - D 396 - 293 —WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS sses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nponent Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary cing per BCSI. Unless noted otherwise, top chord shall have pr in r attached structural sheathing and bottom chord shall have a properly iched rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracinginstalled per BCSI sections B3, B7 or B10, 3DDlicab-le. ADD Dates to each face of truss and Dosition as shown above and on the JoinrDetails, unless noted otherwise. Refer to Is 16OA-Z torstandard plate positions. Reter to Job's General Notes page Tor additional intormation. a division of ITW BuildincLComponents Group Inc. shall not, be responsible for any deviation from this drawing, any. failure to build the conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawing or cover pagqe )is drawing indicates acceptance of professional enneering responsibilityy solely -for the design shown. The suitability and use ofth!s for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. information see these web sites: Alpine: alpineitw.com• TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org ALPINE ANI COWANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250057 / HIPS Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T18 / FROM: LPM Qty: 1 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53322 Truss Label: D3G KD / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " L 3' 7' i 10, r 3' + 4' T 3' '1 4X6 4X6 12 C D 6� T B E 1112X4 1112X4 �- 2X4(A1) = 2X4(A1) 1 3'1"12 3'1"12 Wind Criteria Wind Sid: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -1.00 to 56 pif at 3.00 TC: From 28 plf at 3.00 to 28 plf at 7.00 TC: From 56 plf at 7.00 to 56 plf at 11.00 BC: From 20 plf at 0.00 to 20 plf at 3.03 BC: From 10 plf at 3.03 to 10 plf at 6.97 BC: From 20 plf at 6.97 to 20 plf at 10.00 TC: 129 lb Conc. Load at 3.03, 6.97 TC: 65 lb Conc. Load at 5.00 BC: 80 lb Conc. Load at 3.03, 6.97 BC: 52 lb Conc. Load at 5.00 Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Eon 3'8"8 6' 10"4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/l 0(0) Plate Type(s): 3'1 "12 10, 1 Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.022 H 999 240 VERT(CL): 0.044 H 999 240 HORZ(LL): 0.008 C - - HORZ(TL): 0.016 C Creep Factor: 2.0 Max TC CSI: 0.288 Max BC CSI: 0.365 Max Web CSI: 0.059 VIEW Ver: 20.02.00A.1020.20 e� n . :r f t$�ffi o ?, � F a a ® o a e COA SVn g jYR11f19a9Dl 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 625 /- /- /- /316 /- E 625 /- /- /- /316 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 E Brg Width = 8.0 Min Req = 1.5 Bearings B & E are a rigid surface. Bearings B & E require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 467 - 962 D - E 467 - 962 C - D 389 - 842 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - H 829 - 394 G - E 829 - 394 H - G 842 - 389 **WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply lates to each face o truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for s�andard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin _Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSIPI1, or for handling, shipping,i . nstallation and bracin4of trusses. A seal on this drawing or cover pa e listing this drawing indicates acceptance of professional enccLLineering responsibility solely -for the design shown. The suitabilif and use of This drawing for any sgructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. ALPINE ANMCOMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250045 / VAL Ply: 1 Job Number: N334504 Cust: R8975 JRef:1Xa189750114 T14 / FROM: LPM Qty: 1 7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52900 Truss Label: V4 KD / WHK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 1'11"8 1 3'11" 111"8 11'11"8 12 6 =4X4 B A4X4(D1)=4X4(D1) C 10'6"3 D 3'11" 3'11" 3-11" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.004 999 240 VERT(CL): 0.007 999 240 HORZ(LL): -0.001 - - HORZ(TL): 0.003 Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.098 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 10/29/2021 ♦ Maximum Reactions (lbs), or'=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D* 75 /- /- /32 /18 /6 Wind reactions based on MWFRS D Brg Width = 47.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for sa shipping, practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildingg Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the ANMCOWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawin indicates acceptance of professional en sneering responsibility solely -for the design shown. The suitability and use of this Suite Fos drawing for any structure is the responsibility of the BuildingUesigner per ANSIfTPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA_ sbcindust_ry.com; ICC: iccsafe.org; AWC: awc.org Orlando FL, 32821 SEON: 250046 / VAL Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T16 I FROM: LPM Oty: 1 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53384 Truss Label: V8 KD / WHK 10/28/2021 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 3'11"8 7'11" 3'11"8 3'11"8 =4X4 12 B T 6 N=4X4(D1) A =4X4(D1) C Li 9 6'3 -om E D 1112X4 r 7'11" - Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 3'11 "8 3'11 "8 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): 3'11 "8 7-11" Defi/CSI Criteria PP Deflection in loc L/defl U# VERT(LL): 0.007 D 999 240 VERT(CL): 0.014 D 999 240 HORZ(LL): -0.003 D - - HORZ(TL): 0.006 D Creep Factor: 2.0 Max TC CSI: 0.266 Max BC CSI: 0.192 Max Web CSI: 0.142 EW Ver: 20.02.00A.1020.20 Z1 N.Yoaaa gospa AT ( 1 � COA I � N A4 10/29/2021 ♦Maximum Reactions (lbs), or*=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL E* 75 /- /- /35 /26 /8 Wind reactions based on MWFRS E Brg Width = 95.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - D 478 - 315 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincLComponents Group Inc. $hall not, be respponsible for any deviation from this drawing, any failure to build the a mvcoManuv truss in conformance with ANSI 1, or for handling, shipping,. installation,and bracingof trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en ineering responsibilitty� solelyor the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the BuildingPes!gner per ANSIrT 11 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250047/ EJAC Ply: 1 Job Number: N334504 Cust: R8975 JRef:1Xa189750114 T15 ! FROM: JRH Qty. 8 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALIMEBB ELEV.D/F DrwNo: 301.21.1607.52696 Truss Label: EJ7 �KD / YK 10/28/2021 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 12'2"11 12 6 c*� o_ U-) v B D +8 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 7- 7- Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.015 D HORZ(TL): 0.028 D Creep Factor: 2.0 Max TC CSI: 0.720 Max BC CSI: 0.507 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 i �.108 1 a m ® AST 0 .p � '0 COA $� t V A `l810i19fD'S1ifCa41 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 331 /- A /249 /108 /208 D 125 A /- /73 /- /- C 174 /- /- /128 /169 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$ctComponents Group Inc. shall not, be respponsible for any deviation from this drawing, any, failure to build the aNmvcoMvnNY truss in conformance with ANSI/TPI 1, or for handling, shipping,, Installatlon.and bracin of trusses. A seal on this drawing, or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional en meenng responsibilitty�r solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building�esigner per ANS11TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250048 / EJAC Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T21 / FROM: HMT Qty: 6 ,7A5/320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53181 Truss Label: EJ7A KD / WHK 10/28/2021 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. ►I Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): B Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.016 C HORZ(TL): 0.030 C Creep Factor: 2.0 Max TC CSI: 0.738 Max BC CSI: 0.513 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 Aa 4 0 ® o.708 1 Q 0 9 Y ®° o q, b � COAp f 1 ON �a em 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL A 270 /- /- /179 /71 /186 C 126 /- /- /76 /- /- B 177 A A /132 1171 A Wind reactions based on MWFRS A Brg Width = 8.0 Min Req = 1.5 C Brg Width = 1.5 Min Req = - B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component. Safety Information, by TPI and SBCA) fo'r sa shipping, practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached r'i id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicabgle. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not, be responsible for any deviation from this drawing, any, failure to build the ANTNcoMOANv truss in conformance with ANSI 1, or for handling, shipping,, Installa ion and bracingof trusses. A seal on this drawn or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en tneering responsibilittyv solelyor the design shown. The suitabili>9y and use of this Suite Fos drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250049 / EJAC Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T24 ! FROM: LPM Qty: 3 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53212 Truss Label: EJ3 KD / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TC DL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 10'2"11 c� CD to � r B c� N 8111 A V D Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 3r 3 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.248 Max BC CSI: 0.112 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 r ° • g 9 a 0 0 �� SPIT CM =d % A% 1• ply X0°b0ae�a a0*000* 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- !Rh /Rw /U /RL B 188 /- /- /157 [71 /100 D 52 /- /- /28 /- /- C 65 1- /- 145 /66 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attacheTriV ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face otruss and position as shown above and on the JoinQDetails, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincLComponents Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the AN wco vANv truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 675o Forum Drive listing this drawing indicates acceptance of professional enpmeering responsibilityy solely -for the design shown. The suitability and use of this Suite Fos drawing for any sQr'ucture is the responsibility of the Building -Designer per ANSI TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org;_AWC: awc.or Orlando FL, 32821 SEQN: 250050 / JACK Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T23 ! FROM: RWM Oty: 2 , A5i320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.51352 Truss Label: EJ2 KD / WHK 10/28/2021 12 C T8 rk 918114 4-3 A r 81Q(Jrr -� D 2X4(A1) 21 21 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria TOLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): NA BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.000 D Des Ld: 37.00 C Kzt: NA HORZ(TL): 0.001 D Mea Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.137 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.026 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Fac: Yes Max Web CSI: 0.000 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): IVIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. CID 0 AL � ple"i0i 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 157 /- /- /140 154 /52 D 32 /- /- /18 /- /- C 34 /- /- /20 /26 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearings B, D, & C require a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI andSBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigpid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. ffefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCOWAW truss in conformance with ANSI/1 PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover page 675o Forum Drive listing this drawingp indicates acceptance of professional en ineenng responsibilityN solely -for the design shown. The suitability and use of Ellis drawing for any sfructure is the responsibility of the Building -Designer per ANSlffP1 1 Sec.2. Suite 305 For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindustry.com; ]CC: 1ccsafe.org; AWC: awc.org Orlando FL, 32821 SEQN: 250051 / JACK Ply: 1 Job Number: N334504 Cust: R8975 JRef: 1Xa189750114 T34 / FROM: JRH Qty: 4 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53213 Truss Label: CJ5 �KD / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C. 11'2"5 12 6 rn (V M M B 1-3 A 8'8" �� D 1 4'11"4 411 "4 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.005 D HORZ(TL): 0.010 D Creep Factor: 2.0 Max TC CSI: 0.549 Max BC CSI: 0.257 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 ` Y@ O �r 6 d 08 1 a M � 6 e � P RAT 0to e •"°'° COA ��� ��`a�aratt�t�@8� 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity LOG R+ / R- / Rh / Rw / U / RL B 256 /- /- /200 /88 /152 D 89 /- /- /51 /- /- C 118 /- /- /85 /116 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attache. rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinlComponents Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the pN RNC"MFANY truss in conformance with ANSI 1, or for handling, shipping,, installation and bracing of trusses; A seal on this drawing or cover pa a 6750 Forum Drive listing this drawin Indicates acceptance of professional engineering responsibilitty� solely �or the design shown. The suitability and use of )his Suite Fos drawing for any sfructure is the responsibility of the Building -Designer per ANSIlTP1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 250052 / JACK Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xal89750114 T33 / FROM: LPM Qty.. 4 ,7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53227 Truss Label: CJ3 / WHK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " V �— 1' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 2'11'A 2'11'A Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): C Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.234 Max BC CSI: 0.105 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 �Pq®PCA4oyb* + o o. '08 1 1 Pb q� Py �®n�bP��ygP'"®�i & Q' COA(�1v 10/29/2021 10'2"5 rn m N 8'8" ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 185 /- /- /156 171 /99 D 50 A !- /27 /- /- C 63 /- /- /44 /64 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r sa shipping, practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have �roper)y attached structural sheathing and bottom chord shall have a properly attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the ANmvcoMCANr truss in conformance with ANSI/1 PI 1, or for handling, shipping,. Installation and bracin4of trusses. A seal on this drawm or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engq�ineering responsibility solely -for the design shown. The suitability and use of illis Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN:250053/ JACK Ply: 1 Job Number: N334504 Cust:R8975 JRef:1Xa189750114 T29 / FROM: LPM Qly: 8 7A51320 ,182ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53071 Truss Label: CJ1 / YK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T F 12 6 [7- C Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 1, 11114 11114 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA [ding Code: C 7th Ed. 2020 Res. I Std: 2014 p Fac: Yes rRT:20(0)/10(0) to Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Creep Factor: 2.0 Max TC CSI: 0.183 Max BC CSI: 0.022 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 B g a 04. a 1� y COA i�A�� 10/29/2021 9'2"5 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /145 /76 /45 D 11 /-2 /- /14 /10 /- C - /-15 /- /29 /33 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attachetl rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinA_Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the ANI CDWAW truss in conformance with ANSIPI1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en ineenng responsibili��r solely -for the design shown. The suitability and use of This Suite 305 drawing for any structure is the responsibility of the BuildinggDes!gner per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.orp Orlando FL, 32821 SEQN: 250054 / HIP_ Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T22 / FROM: HMT City: 2 ,7A5/320 ,1,2ED,F ,02G ,RI01 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.52743 Truss Label: HJ7 �KD / WHK 10/28/2021 5'3"5 5'3"5 9'10"1 4'6"l 1 X 12'2"3 12 4.24 2X4 C v m � v B a 33 A 8'8" FE 2X4(A1) =4X4 �--- 1,5" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 0.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; Loading Hipjack supports 6-11-8 setback jacks with no webs. 9'2"2 9'2"2 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): WAVE 7.1 1 1 90'1 DeflICSI Criteria PP Deflection in loc L/defl U# VERT(LL): 0.049 F 999 240 VERT(CL): 0.092 F 999 240 HORZ(LL): 0.012 C - - HORZ(TL): 0.023 C Creep Factor: 2.0 Max TC CSI: 0.542 Max BC CSI: 0.670 Max Web CSI: 0.261 Ver: 20.02.00A.1020.20 Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 16d Common (0.162"x3.5") nails, toe nailed at T.C.gtRsatttlattl{��� nailed at () 16d Common (0. 1 62"x3.5") nails, toe �� +rxpPpf ff ® C. 0.708 1 s s"9 16l1 l9 a a- 6jy y COA A13 SON AL aaz' ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 326 /- /- /- /154 /- E 364 /- /0 /- /84 /0 D 214 /- /- /- /177 /- Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 392 - 565 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - F 534 - 356 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 391 - 587 10/29/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections 53, B7 or B10, as applicab-le. Apply Oates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSIITPI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa e listing this drawing indicates acceptance of professional en ineenng responsibilitty�r solely -for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building -Designer per ANSIrT 11 Sec.2. For more information see these web sites: Alpine: alpineilw.com; TPI: tpinst.org• SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org ALPINE AN rrW COMPANY 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 250055 / HIP_ Ply: 1 Job Number: N334504 Cust: R 8975 JRef:1Xa189750114 T17 ! FROM: LPM Qty: 2 7A5/320 ,182ED,F ,02G ,R101 / 1828/CALI/4EBB ELEV.D/F DrwNo: 301.21.1607.53009 Truss Label: HJ3A KD / WHK 10/28/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 12 4.24 T 10'2" 6 N $ipn A VV D Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C K7t: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Loading Hipjack supports 2-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 412°3 i 4'2"3 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D HORZ(TL): 0.002 D Creep Factor: 2.0 Max TC CSI: 0.120 Max BC CSI: 0.074 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 10/29/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 84 /- /- /- /45 /- D 28 /- /- /7/- C 64 /- /- /- /48 !- Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Referto ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not.be responsible for any deviation from this drawing, any, failure to build the nNm coMaauv truss in conformance with ANSI 1, or for handling, shipping,. installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional enoneering responsibili solely -for the design shown. The suitability and use ofQ is Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANS1141 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 ' Gable Stud Reinforcement Detail ASCE 7-16i 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1,00 Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Or, 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or, 120 mph Wind Speed, 15' Mean Heiqht, Partially Enclosed, Exposure D, Kzt = 1.00 S 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) lx4 'L' Brace w (1) 2x4 'L' Brace x (2) 2x4 'L' Brace xIK (1) 2x6 'L" Brace x (2) 2x6 'L' Brace 030 Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B p #1 / #2 3' 10, 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12, 8' 14' 0' 14' 0' SI F #3 3' 8' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' U I I r Stud 3' 8' 5' 9' 6' 1' 7' 8' 7' 11' 9' 1' 9' 6' 12' 0' 12, 6' 14' 0' 14' 0' O rl r Standard 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' 11' 9' 6' 1 10' 4' 11' 1' 14' 0' 14' 0' Q% #1 4' 0' 6' 8' 6' 11' 7' 10' 8' 2' 9' 4' 9' 8' 12' 4' 12' 9' 1 14' 0' 14' 0' S P #2 3' 10, 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' (u D rr L Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U #1 / #2 1 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' _ S P P #3 4' 2' 7' V 7' 9' 8' 9' 9' 1' 10' 5' 10, 10' 13' 9' 1 14' 0' 14' 0' 14' 0' U u r Stud 4' 2' 7' 1' 7' G' 8' 9' 9' 1' 10' 5' 10, 10, 13' 9' 14' 0' 14' 0' 14' 0' I� r Standard 4' 2' 6' 1' 6' 5' 8' 1' 8' 8' 10' 5' 10, 10, 12, 8' 13' 7' 14' 0' 14' 0' O #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10, 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' S P #2 4' 5' 7' 6' 7' 9' 8' 10' 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' 11 #3 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' QJ D P L Stud 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10' 11' 13' 4' 14' 0' 14' 0' 14' 0' Standard 4' 2' 5' 8' 6' 0' 7' 6' 8' 0' 10' 2' 10, 10' 11' 10, 12' 7' 14' 0' 14' 0' [- #1 / #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 10' 7' 12, 1' 14' 0' 14' 0' 14' 0' 14' 0' d S P r #3 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' �J U u 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' O I� Standard 4' 7' 7' 0' 7' 5' 1 9' 4' 10, 0' 11' 6' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' 1' 8' 5' 8' 8' 9' ill 10' 3' 11, 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 11' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' D rr L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' rl Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 1 14' 0' 14' 0' 14' 0' Diagonal brace option, vertical length may be doubled when diagonal brace Is used. Connect dlagonal brace for 600# at each end. Max web total length Is 14'. Vertical length shown In table above. Connect cilaaonnl at AN ITW CO 11514\ Earth\ City\ Expressway \ 1 Suite\ 242 l \ Earth\ City,\ MO\ 63045 �ymm About) 18, L 'L' Brace End Zones, typ. 2x6 DF-L #2 or better diagonal 'r bracel single 8, or double cut L (as shown) at upper end. ylrl N111-1 N41-1 Refer to chart rk -VARNINGI- READ AND FOLLOV ALL NOTES 13N THIS DRAWING! "IMPORTANT.. Fl1RNISH THIS DRAVING TO ALL CDNTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. R. t ,:low the latest edition of BCSI (Building Component Safety Information, by TPI antl SBCA) fa s, nctices prior to performing these functions, Installers shall provide temporary bracing pew B ,less noted otherwise, top chord shall have properly attached structural sheathing and bo ,all have a properly attached rigid ceiling. Locations shown for permanent lateral restraint N ,all have braclng Installed per BCSI sections 113, B7 or BIO, as oppllcable. Apply plates to eac, truss and position as shown above and on the Joint Details, unless noted otherwise. , Fer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any deviatl Is drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shlpj -tallation & bradng of trusses. A seal on this drawing or cover page Msting this drnwtng, Indicates acceptance of professional gineering responsIlAtty solely for the design shown. The suitability and use of this drawng r any structure Is the responstblllty of the Building Designer per ANSI/TPI 1 Sec2. For more Information see this Job's general notes page and these web sites, ALPINE, rrw.nlolneltr.com, TPI, rrw.tolnst.oro, SBCA, wwr.sbclndustrv.ora, ICC, wwwlccsafe.oro 0a Bracing Group Species and Grades, Group At S ruce-Plne-Fir Hen -Fir #1 / #2 Standard 1 #2 1 Stud #3 Stud 1 #3 IStanclard Dou Las Fir -Larch Southern Plne)Kwx #3 �Stud tStandard Stan Group BI Hen -Fir #1 & Btr #1 Douglas Flr-Larch Southern Pine... #I #I #2 #2 lx4 Braces shall be SRB (Stress -Rated Board). ■.For Ix4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group B values may be used with these grades. Gable Truss Detail Notes: Wind Load deflection criterion Is L/240. Provide uplift connections for 75 plf over continuous bearing (5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with 10d (0,128'x3.0' min) nails. )K For <1) 'L' brace, space nails at 2' o.c, In 18' end zones and 4' o.c. between zones. )KFor (2) 'L' braces, space nalls at 3' o,c. In 18' end zones and 6' o.c. between zones. 'L' bracing must be a minimum of 80% of web member length. Gable Vertical Plate Sizes lddllg �d . Vertical Length No S lice Less than 4' 0' 2X3 Greater than 4' 0', but 3X4 Greater than 11' 6' 4X4 I + Refer to common truss design for peak, splice, and heel plates. Refer to the Building Designer for conditions abl ve ti' lep th, not addressed by this cietall, REF ASCE7-16-GAB16015 DATE 01/26/2018 0 �° DRWG A16015ENC160118 MAX, TOT. LD, 60 PSF bp�a�Y4 /29/2021 66 MAX, SPACING 24,0" 'T' Reinforcing Member Gable Truss Gabe Detail For Let -in Verticals Gable Truss Plate Sizes 3propriate Alpine gable detail for e sizes for vertical studs, Engineered truss design for peak, b, and heel plates. vertical plates overlap, use a to that covers the total area of apped plates to span the web, „ 2X4 2X4 2X8 rroviae connecilons ror upurz spec.r.ea an zne engineerea truss aes.yn. Attach each 'T' reinforcing member with End Driven Nails. lod Common (0.148'x 3,',min) Nails at 4' o.c, plus (4) nails In the top and bottom chords. Toenalled Nalls, 10d Common (0,148'x3',min) Toenails at 4' o,c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detall Drawings A11515ENC100118, A12015ENC100118, A14015ENC100118, A16015ENC100118, A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118, A11530ENC100118, A12030ENC100118, A14030ENC100118, A16030ENC100118, A18030ENC100118, A20030ENC100118, A20030END100118, A20030PED100118, S11515ENC100118, S12015ENC100118, S14015ENC100118, S16015ENC100118, S18015ENC100118, S20015ENC100118, S20015END10011 1 ftQ S11530ENC100118, S12030ENC100118, S14030ENC1 3041001�ar/ 518030ENC100118, S20030ENC100118, S20030E 01 � I b10 ,�° aaw Haan i See appropriate Alpine gable detail for maxi) 111 .; cS t dgrt° 'T' Reinforcement Attachment Detail 'T' Reinforcing 'T' Reinforcing Member Member Toe -nail - Or - End-nall To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical Length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member, elo Length Increase w/ "T" Brace Example, ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o,c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 307 = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' 'T' Relnf, Mbr, Size 'T' Increase 2x4 30 2x6 20 t> PI AN ITW COMPANY 11514\Earth\City\Expressway \ \ Suite\ 242 \\Earth\City,\MO\63045 wwVARNrNGIww READ AND F13LLDV ALL NDTES 13N THIS DRAWING! 9 "IMP13tTANTAw FURNISH THIS DRAVING TD ALL CONTRACT13RS INCLUDING THE INSTALLERSa a Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Ref - nj follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) fo s tyo practices prior to performing these functions. Installers shall provide temporary bracing pe. BCSI, w Unless noted otherwise, top chord shall have properly attached structural sheathing and bo m chodl shall have n properly attachetl rigid telling. Locotlons shown for permanent lateral restraint s shall have bracing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to ead of truss and position as shown above and on the Joint Details, unless noted otherwise. ✓ Refer to drawings 160A-Z for standard plate posltions. Alpine, a division of ITV Building Components Group Inc shall not be responsible for any devlatio r this drnwing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shlppin Instnllntlon 6 bracing of trusses. A seal on this drawing or cover page UsI i g this drawing, indicates acceptance of professional for any ntructtae Is reresponsibility «sponsibftlfor ty of to HuRding DeslgnernbperyANS�IR I 1 Sec2use of this w�+�t4\t��29�2•021 For more Information see this Job's general notes page and these web sites. ALPINE. www.alpineitw,coml TPD www.tpinst.orgl SBCA. www.sbcindustry.orgl ICO www.Iccsafe.org 1 U. t ary � a e. R' $° 1 awry we m� add ea wad s'a °ea-Z. am°f°ana" ` ) q MAX, TOT, LD, 60 PSF REF LET -IN VERT DATE 01/02/2018 DRWG GBLLETIN0118 DUR, FAC, ANY MAX, SPACING 24,0" NAIL SPACING DETAIL iHINIMUM SPACING FOR SINGLE BLOCK IS SHOWN, DOUBLE NAIL SPACINGS AND STAGGER NAILING FOR TWO BLOCKS, GREATER SPACING MAY BE REQUIRED TO AV❑ID SPLITTING, BLOCK L❑CATI❑N, SIZE, LENGTH,GRADE AND TOTAL NUMBER AND TYPE OF NAILS ARE TO BE SPECIFIED ON SEALED DESIGN REFERENCING THIS DETAIL, LOAD PERPENDICULAR TO GRAIN A - EDGE DISTANCE AND SPACING BETWEEN STAGGERED ROWS OF NAILS (6 NAIL DIAMETERS) B - SPACING OF NAILS IN A ROW (12 NAIL DIAMETERS) C - END DISTANCE (15 NAIL DIAMETERS) LOAD PARALLEL TO GRAIN A - EDGE DISTANCE (6 NAIL DIAMETERS) C - SPACING OF NAILS IN A ROW AND END DISTANCE (15 NAIL DIAMETERS) D - SPACING BETWEEN STAGGERED ROWS OF NAILS (7 1/2 NAIL DIAMETERS) IF NAIL HOLES ARE PREB❑RED, SOME SPACING MAY BE REDUCED BY THE AMOUNTS GIVEN BELOW SPACING MAY BE REDUCED BY 50Z c row SPACING MAY BE REDUCED BY 33% I I DIRECTI❑N OF LOAD AND NAIL ROWS Z J cA,A, NAIL �. LINE � J po A B* B/2 � 1 1 1 1 1 A I C)K C)K MINIMUM NAIL SPACING DISTANCES DISTANCES NAIL TYPE A Bw C)K)K D 8d BOX <0,113'X 2,5',MIN) 3/4' 1 3/8' 1 3/4' 7/8' 10d BOX (0,128'X 3.',MIN) 7/8" 1 5/8' 2" 1' 12d BOX <0,128'X 3,25',MIN) 7/8" 1 5/8" 2" 1" 16d BOX (0.135'X 3.5",MIN) 7/8' 1 5/8' 2 1/8' 1 1/8' 20d BOX (0,148"X 4,',MIN) 1' 1 7/8' 2 1/4" 1 1/8" 8d COMMON (0,131'X 2,5',MIN) 7/8' 1 5/8' 2' 1" 10d COMMON (0,148'X 3,",MIN) 1' 1 7/8' 2 1/4' 1 1/8" 12d COMMON (0,148"X 3,25",MIN) 1' 1 7/8' 2 1/4' 1 1/8" 16d COMMON (0,162'X 3,5',MIN) 1' 2' 2 1/2' 1 1/4' GUN (0,120"X 2,5',MIN) 3/4" 1 1/2" 1 7/8" 1" GUN (0,131'X 2,5',MIN) 7/8' 1 5/8' 2" V GUN (0,120"X 3,',MIN) 3/4" 1 1/2" 1 7/8" 1" GUN (0,131'X 3,',MIN) 7/8' 1 5/8' 2' 1" C/2)" NAIL LINE C)K)K TRUSS MEMBER BLOCK LENGTH A D D D A >w LOAD APPLIED PERPENDICULAR TO GRAIN LOAD APPLIED PARALLELAI s 'WAI uIGI-M R AD MD FaI-L°V ALL NOMS °N THIS DR"m+° Ar® REF NAIL SPACE wwllWQ2TANTww FURNISH THIS DRAWING TO ALL CWIN TRACTEIRS CLl1DING THE INSTA(.LERSg: a extreme bracing,andt eust ((Building Informatonn, bya a a DATE 10/01/14 ofcare TPInd followTrusthe lates editionBCSI ComponentliSafetyp CARe'a s practices prior to performing these functions. Installers shall provide temporary bracing pe. BCSI. w Unless noted otherwise, top chord shall have properly attached structural sheathing and bo m chop W T Y°1 s DRWG CNNAILSP1014 shall have a properly attached rigid ceiling. Locations shown for permanent lateral restralnt f se ! lJ .l shall have bracing Installed per BCSI sections 113, B7 or BIG, as applicable. Apply plates to ead"pr r of truss and position as shorn above and on the Joint Details, unless noted otherwise. .•„ ®° ,(,"• Lr a ,`.V d PI Refer to drawings 1f IT For standard pints positions. Alpine, n division of ITV Components Group Inc. shall not responsible for any devlatio % 4kwwre a°aa AN ITW COMPANY build SI this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shippin Installation tC bracing of trusses. ///qa g, 1\514\Earth\City\Expressway 1111 Suite\ 242 A sent on tlds drawing or rover page ltsrig this drawl g, Indkates acceptance of professional ergineerinresponskrXitysole lithe desk shown. The Winer per and usedraw k,g fw any 1 f this �( { ip . �+ 7 Y Ai. "�/29/2021 \\Earth\City,\MO\63045 For more Information see this ,Job's general notes page and these web sites, ALPINE, www.a(pineltw.coml TPI, www.tptnst.orgl SBCA, www.sbclndustry.orgi ICG wwwlccsafe.org Valley Detail - ASCE 7-16: 180 mph, 30' Mean Height, Partially Enclosed, Exp, C, Kzt=1,00 T'op Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, )K)KAttach each valley to every supporting truss with: 535# connection or with (1) Simpson H2,5A or equivalent connector for ASCE 7-16 180 mph. 30' Mean Height, Part, Enc, Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or ASCE 7-16 160 mph, 30' Mean Height, Part, Enc, Building, Exp. D, Wind TC DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown. Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are Alpine Wave Plates. Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% length of web, same species and grade or better, attached with 10d box (0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014. Top chord of truss beneath valley set must be braced with: properly attached, rated sheathing applied prior to valley truss installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, WWW Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. 2X4 4X4 12 3X4 Valle 12 Max, I Spacing 2X4 X4 Pitched Cut Square Cut Stubbed Valley Optional Hip - 8-0-0 max Bottom Chord Bottom Chord End Detail Joint Detail Valley b Vallev 4X4 20-0-0 (++) -! Supporting trusses at 24' o,c, maximum spacing, Q p.L��i�eaammtmtEm r No NONE MIMMERNME Partial Framing Plan P' AN ITW COMPANY 115141 Earihl City\ Expressway 11 Suite%242 11 Earth\ City,% MO\63045 ..VAMMGI.. READ Amm Fw_LOV ALL NMS ON THIS MAVuua 3 s ..IMPMTANT.. FURNISH THIS IDIAVM M ALL CONTRACTIIRININS S CUMM THE TALLERS. a Trusses require extreme care In fabricating, handling, shipping, Installing and bracing, Refer Z. g follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) far f w practices prior to performing these functions. Installers shall provide temporary bracing per SI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bott chordP shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint o rqq� shall have bracing Installed per, BCSI sections B3, B7 or H10, as applicable. Apply plates to eachsn Ah' of truss and position as shorn above and on the Joint Details, unless noted otherwise. �' Refer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviation m this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for hnndUng, shipping, Installation 6 brndng of trusses. �� listing this drawing, Indicates acceptance of A seal on this drawing or cover p professional engineering responsibility solely for the design Shawn. The suitability and use of this drawing for any structure is the responsibility of the oft Resigner per ANSI/TPI 1 SecZ H For more Information see this Job's general notes page and these web sites. ALPINE, www.alpineitw,comi TPIi www.tpinst.orgl SEM ww.,sbcindustry.orgl ICCj wwwlccsafe.org U. rW1U m - 6 w ° m AT y° "° a a? P1 m r 0w "l! w` ® 't% OA ®q * , a'� ®vwa o� ,�" r 6B $n1 1+1/29/2021 N LL 30 TC DL 20 BC DL 10 BC LL 0 TOT. LD, 60 30 15 10 0 40PSF 7 PSF 10 PSF 0 PSF 57PSF REF VALLEY DETAIL DATE O1/26/2018 DRWG VAL180160118 55 DUR,FAC,1.25/1.33 1.15 1.15 SPACING 24,0° Valley Detail - ASCE 7-16; 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, WX Attach each valley to every supporting truss with: (2) 16d box (0,135' x 3,5') nails toe -nailed for ASCE 7-16, 30' Mean Height, Enclosed Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00, Max, Wind Speed based on supporting truss material at connection location: 170 mph for SP (G = 0.55, min,), 155 mph for DF-L (G = 0,50, min,), or 120 mph for HF & SPF (G = 0,42, min.), Maximum top chord pitch is 10/12 for supporting trusses below valley trusses, Bottom chord of valley trusses may be square or pitched cut as shown, Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% length of web, same species and grade or better, attached with lid box (0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014. Top chord of truss beneath valley set must be braced with: properly attached, rated sheathing applied prior to valley truss Installation. Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0', All plates shown are Alpine Wave Plates, 4X4 2X4 3X4 12 Valle 12 MSpacing 2X4ax, X4 Pitched Cut Square Cut Stubbed Valley Optional Hip 8-0-0 max •+ Bottom Chord Bottom Chord End Detail Joint Detail Valley Valley 4X4 Toe -nailed / ��j o m n T u e 12 Max, t 2 o, , X3 ll S t 12 1X36-0-0 10 Max. ��� a 4 <Max Spacing) 2X4 QG��9 1X3 1X3 SQo �tt3hat1ahl°eetatrpdjid `°° Common Tf usses 20-0-0 (++) °•. f at 2 ` o,c, Partial Framing Supporting trusses at 24' o,c, maximum spacing,.�`�� � °�' ep Plan a .wVAW7MM READ AM PTILLDv ALL NDTES ON niIS WAVINa ® Q. LL 30 30 40PSF REF VALLEY DETAIL ■KWMTANTIM FURNISH THIS DRAVM M ALL CRITRACTMS MCLUBrNG nK INSTALLERS Trusses require extreme care In fabricating, handling, shipping, Installing and bracing• Re ` a�d TC DL 20 15 7PSF DATE O1/26/2018 follow the latest edition of SCSI (Building Component Safety Information, by TPI and SHCA) f Se a' practices prior to performing these functions. Installers shall provide temporary bracing BCSI.a r Unless noted otherwise, top chord shall have properly attached structural sheathing and b tom c4?rd �w AR' {`� BC DL 10 10 10 PSF DRWG VALTN160118 shall have a properly attached rlgld ceiling. Locations shown for pernanent lateral restrain of bs ? P: T v shall have bracing Installed per BCSI sections B3, H7 or HIO, as applicable. Apply plates to a%h eba s of truss and position as shown above and on the Joint Details, unless noted otherwise. /. ,pe 8�y.'t' BC LL 0 0 0 PSF PI Refer to drawings 160A-Z for standard plate positions.Ae Alpine, a division of ITV Building Components Group Inc, shall not be responsible for any devlatl aow 1 pe y this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for hnndling, shlppi 141� `�aarraaa'(`,ti,'`t TOT. LD, 6� 55 57PSF AN ITW COMPANY Installation S bracing of trusses. y? yr A seat on this drawing or cover page Usti g this dravI g, Indicates acceptance of professtonwl j°e ®tg /29/2021 11514\ Earth\ City\ Expressway engineering responsibility solely for the design shorn, The suitability and use of this drawing�d/ (JY�j t0' IISuite\242 for any structure Is the responsibility of the Building Designer per ANSI/TPI I Sect. A" _ S6$8 DUR,FAC,1,25/1.33 1.15 1.15 15 Earth\ City,\ MO\ 63045 For more Information see this Job's general notes page and these web sites SPACING 24,0' ALPINE www,alpineltw.comi TPIi www,tpinst.orgi SBCA, www.sbclndustry.orgb ICO wwvlccsafe.org i • ! d VALLEY FRAMING & BRACING DETAIL 11imhPr Site and Grade Minumum Reauirements GENERAL NOTES Purlins required 2'-0" O.C. in absence of plywood sheathing. Trusses without sheathing applied must be evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this is impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2 5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'.0" or less -Maximum valley height: 14'-0" -Maximum mean roof height: 30 feet -ASCE 7-05, 140 mph, Enclosed, Cat II, Exp B,1=1.0, Kzt=1.0 Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ipples 4'-0" for 30 psf (TL) and 20 psf (TD) Max. :e the crippes for each row starting from the valleys or sleepers working Inward to the ridge board so that cripple locations are gored between rows. TYP) innection Requirement Notes 2x6 rafters to ridge 416d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 416d toe -nails (••) 816d face -nails Rafter to sleeper or blocking 5 16d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 316d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 3 16d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 3 16d toe -nails CRIPPLE, BRACING & BLOCKING NOTES N Cold(0.16ar mto5")C 416dtoe-nails m NOTE: 16d (0.162"x3.5") COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0" to 10'-0" long nailed w/ 2 -10d (0.148'W") nails. Or 2x4 "T" or scab reinforcement nailed to flat edge of cripple with 10d 10.128"x3.0") nails at 6" o.c. ,r, or scab must be 90 % of cripple length. Cripples over 10'-0' long requre two CLR's or both faces w/'T' or scab. Use stress graded lumber & box or common nails. ,Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are Installed into ridge board -Install blocking under rafter if sleepers are not used. -Install blocking under cripples If cripples fall between lower truss top chords and lateral bracing Is not used. -Apply all nailing in accordance to current NDS requirements. Nails are common wire nails unless noted otherwise. •- -WARtG14G w READ MID FBLLDW ALL taTES oN THIS pmwiW a .-aHPWWT— FTRMSH THIS DRAWING TD ALL fYlRRACTTIRS DRL_TMr THE INSTALLERS+ Trusses requ<-e ext—e care N fabr4c.1kV h-.4 HppkV, InstalDnp —d b—.k,& , Refer tc follow the latest adltlon of BCSI (RdidkV Compnponent Safety Information. by TPI and SBCA) for:" bless es pri otherWftop these hord t ac?colons. Installers shall proAde temporary bradng per. V properly attadwd structval sheatNng and botaw shall have n properly nttadxd rtgld cAkV. Locntfons sham for permanent lateral restrahtyf ��f� rl� of t Iwve id pas Instas s per BCSabove w Won the J w• BIo, as urkesshl,:. Apply plates to vaQm d O Illllt�\\VV111 of tress and iry k,, as shown above ctl on the Jdnt BIC, s, unless noted ptherwke. .� Refer to drnwkW 16GA-Z for siordard plate posteons. Alpine, a dWsbn of ITV Buading Conp—ts Croup Ix shall not be responsible for any devlat4 AWN ITWCOMPANY this drowhg, any faEure to build the truss In conformance dth ANSI/TPI 1, or for handlhg, shim hstallntlon i brodng of trusses. A seal on this droeing Q cover page Usthg this drawhg, Indcates acceptance of profes-kWAL erpFcRYmp �rrrr�rlty snldy for the deslym shown The sittobAtty and usr of this drnwFmp 13389 Lakefront Drive fw• any i— is t}r rrspa�illty of the RL&dkg Daslprrr psr AI(SI/rPI 1 Sec2 Q38EadI.Ae nt DOve Fr more hfornotlon see this Jobs general notes page and these web sltes N.PDEm m 1phwltw.coml TPIi www.tphskorgi SBM wwwsbdndustry.orgl = n 1ccsafearg r%� G S� t (A) I (B) (.+ t No.70861 TC LL 20 30 40 54 REF VALLEY FRAMING * TC DL 10 20 7 7 DATE 10/01/14 Ad o• STATE BC DL 0 0 0 0 DRWG VACNV1801015 OF ��' BC LL 0 0 0 0 P.••��, i TOT. LD.301 50 47 61 DUR. FAC. 1.25/1.15 SPACING SEE ABOVE 39'-B" REFER TO ENSHINGLE R 0 0 PACK FOR CONNECTION. 17'-4" 10'-0" 12'-4 6 CJS yv� w w w u �� �I CJ3 �� HEEL4-3/1 2 ,_ CJ1A CJ1A PLUMB CU 55 V-4 D3G o 16 IF LT_i TI—Lyl O 2.-0. i'— M Li n n w w w r I n D2 n uT r U U LJ LJ w TYPICAL 7' SETBACK yv) LJ w DI w Ld LJ L-I U CORNERSET LABELING AND SPACING CJl n ^ r< CJl w w w�y4 w w � CJ3 CJ3 a CJ5 CJ5 Reviewed for Code Compliance AIaG Universal Engineering amius Sciences Al Al AB A6 o A4 I N N A2 Al Al Al 00 I o Al (O Do i COPY DO Al Al AlA Al Al AI �KV Al 00 N Al Al Al AREA E%PHSED m WIN➢ Y 1 v • • 1r V • , A3 LtC-, eY9-(9 113-, A5GE ih fl O Total Truss Quantity = 75 D 21'-4" 4'-4" 14'-0" 39'-B" I ATTENTION! THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. Labeled End Mark ESTE ES UN PLAN BE COLOCACION TRUSS, EST4 DISERA➢O PARA AYU➢AR EN LA INSTALACISN DE TRUSSES. LOS DIBUJOS Y ARDUITECTURAS BE INGENIERIA ➢E INGENIERIA SUPERAN ESTE DOCUMENTO. � rust De tNs y if wrie usel Truss is on ¢¢Doge. YRa truss :uy rmt natd: Insist (rnrc aDeratOr sets truss th's Roy. NaiE MILTI-PLY GIRD: CWefftttIX NQR. p0 Nm PUT OR ALTER TRUSSES VITHWT CONSENT Di'ra$ I1 TFrICE CK BA NOTE ALL BEARING WALLS MUST HE ADEQUATELY DESIGNED 1D CARRT THE LOAMR ALL RIES WILL HE FASTEND TOGETHER (BRTS, NAILS, AND OR SCREWS) TOR TO INSTALATION Ma BEFORE ANY LOA05 ARE APPLIED PER THE CHARGES WILL NOT BE ACCEPTE➢ VITImuI PRO. WRITTEN APPROVAL BY GI SERVICE DEPARTMENT AT CARPENTER CONTRACTORS OF AMERICA, INC. IMPOSED BY THE TRUSS OR TRUSSES, AND MUST HE INPLACE AND IN SERVI SUPPLIED ENGINEERING SHEETS. BTT-293-9ABT BEFORE THE TRUSSES ARE SET IN ORDER TO AVOIp REPAIRS. NO—N➢TA. NOTA C(pIEKIGN BE VISAMmTIPLES NO CDRTE NI ALTERE LDS TRUSSES SIN EL CONSENTIMIENm BE ESTA OFICIN T�➢AS LAS PAREDES DE RD➢AMIENTO ➢EHEN SER DISERADAS A➢ECUA➢AMENTE T®AS LAS CAPAS SER4N RAPIDAS JUNTAS (TDRNtLLDS, —as Y TIRNILLDS ANTES DE La INSTALA[ION Y ANTES DE APLICAR NALOUIER [ARGA POI¢ LAS NO sE ACEPTARAN CARGOS ANTERIrttES SIN APROBACIaN PREVIA PIHt ESCRITO E NUESTRa ➢EPARTAMENTO OE SERV[C10 IN CARPENTER CONTRACTORS IN' RA LLEVAR LAS GRGAS 2MPUESTAS PER LOS TRUSS O TRUSSES. Y DEHEN ESTAR EN WGAR T EN SERVICIO ANTES DE 0UE US TRUSSES SE CONFIG General Notes 1) AB parallel chord trusses, flat trusses and flat girders have the top chord partially painted green to be installed green side up. 2) All hangers to be Simpson HU526 unless otherwise noted. 3) All truss spacing is 24' O.C. unless otherwise noted. 4) Per Truss Plate Institute BCSI-B1 recommendation permanent X-bracing should be placed at a maximum spacing 15' O.C. across the span, to be repeated at a maximum of 20' between each X-brace throughout the structure. Please refer to BCSI-81 for any addtianal hradng details. ROOF LOADING SCHEDULE TCLL = 20 PSF BCDLL = " PSF BCDL = 10 PSF TOTAL = 37 PSF DURATION = 1.25 WIND SPD/TYPE= 160 ENCLOSED BLDG EXPOSURE = C USAGE =RESIDENTIAL CAT II WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Tmss member design & comeclorplatcs a]e desired for ASCE 7-16 and maximum forces firm both components and claddings and main wind force resisting systems. • These trusses Lave been reviewed to tarty m edditiona110#'psfnon-co cmreN bottom chord live load. FLOOR LOADING SCHEDUL TCLL = PSF TCDL = PSF BCDL = PSF TOTAL = PSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS AND UPLIFTS ARE SHOWN ON ENGINEERING WALL KEY OB'-8" ® 0 LOAD DESCRIPTION INIT. DATE 2m BASE RVM /e/19 Rr(W BASE LON➢ W(T T/B/20 RI01 BASE tl/11/20 RI01 BASE La40 HMi 3/ID/21 NNT LOADQ DESCRIPTION INF. DATE 02r HLOLREDLINES R. B/6/19 02P REIABEL PROJECT 7/e/20 02G L[A/REV LABELS JTH 11/11/20 02G REV TRUSS LABELS (Pfr 3/I5/21 CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE G. N.W. HINTER HAVEN FLORIDA 33880 PHONE: (800) 959-8606 FAX: (863) 294-2488 BUILDER D.R. HORTON STATEWIDE PROJECT CREEK5IDE MODEL 1828/CALL/4DHH CCA PROJ/MODEL/ALT 7A5/ 320/182ED,F/ 02 ALT DESQARGE HVING R0064 N(10 XB COV L4NAI OTC %LOT 100 BLOCK DESIGNER PAGE RFS �I L DATE 3 31 17 LAN�3345O4L SCALE "=1'