Loading...
HomeMy WebLinkAboutBuilding PlanY 1430 CULVER C)RIVB NE, PALM BAY, F=L 32907 Tel: (321) 733-7092 Fax: (321) 733-7972 STATE OF CERTIFIED BU FLORIDA DING CONTRACTOR: DR HORTON HOMES 1430 CULVER DRIVE NE PALM BAY FL 32907 r TEL: (321) 733-7092 FAX: (321) 733-7972 CRITERIA: ABBREVIATIONS REVISIONS INDEX OF INDEX DRAWINGS -niORIDA BUILDING CODE, 7TH EDITION (2020) -ALL LOCAL AND STATE CODESADJ. -OCCUPANCY — RESIDENTIAL, GROUP R3 - CONSTRUCTION TYPE — VB -MIN. INTERIOR FINISH — CLASS B -BASIC WIND SPEED — Vult=160 MPH Vasd=124 MPH -EXPOSURE — C -1—STORY RESIDENCE — .2—STORY RESIDENCE — MAX. HEIGHT AS PER LOCAL AND STATE CODES ABV. A/C ALT. AMP. BD. cf. CAB. CEO. CLR. CONC. CPT. C,I'. D. DBL. D.G. D]A. DIM. DISP. DP, DR. D.S. DTL. D.W. FA. ELEV. EQ. EXH. EXT. I'.GJFX. F.G. FIN. FIR. FLUOR. FR. DR. FTG. GA. CAR. DISP. G.F.I. GL. GYP. BD. H.B. H.C. NSUL. HT INSUL. INT. ABOVE AIR CONDITIONING ADJUSTABLE ALTERNATE AMPERAGE BOARD CENTER LINE, CABINET CEILING CLEAR CONCRETE, CARPET CERAMIC TILE DRYER DOUBLE DUAL GLAZED DIAMETER DIMENSION DISPOSAL DEEP DOOR DOWNSPOUT DETAIL DISHWASHER EACH ELEVATION EQUAL EXHAUST EXTERIOR FIXED GLASS FUEL GAS FINISH FLOOR FLUORESCENT FRENCH DOOR FOOTING GAUGE GARBAGE DISPOSAL GROUND -FAULT CIRCUIT INTERRUPTER GLASS GYPSUM BOARD HOSE BIB HEADER coxE HEIGHT INSULATION INTERIOR LUM. M.C. MFR. MIN. M.T. MTD. MIL. N.T.S. O.C. PL P.B. PH. PLT. PLYWD. PR. P.T. R. RAD. R.A.G. REF. RM. R.O. S.C. S.D. S.H. SELL. SHTHG. SIIWR. SIM. SL. sL.GL. STD. sws TEMP. TIIK. T.O.C. T.O.P. T.O.S. `LYP. U.N.O. V.P..VAPOR W WD. WDW. W/H W.I. LAVATORY LUMINOUS MEDICINE CABINET MANUFACTURER MINIMUM METALTHRFSHOLD MOUNTED METAL NOT TO SCALE ON CENTER PROPERTY LINE PUSHBuLEON PHONE PLATE PLYWOOD PAIR PRESSURE TREATED RISER RADIUS RETURN AIR GRILL REFRIGERATOR ROOM ROUGH OPENING SOLID CORE EXTDR SMOKE DETECTOR SINGLE HUNG SHEET SHEATHING06/21/19 SHOWER SIMILAR SLIDING SLIDING STANDARD SHEAR WALL SECTION TEMPERED GLASS THICK TOP OF CURB TOP OF PLATE TOP ICAL TYPICAL UNLESS NOTED OTHERWISE ]IR F WITH WOOD WINDOW WATER IILA'TER WROUGHT IRON DATE DESCRIPTION 06/26/11 2-STORY CMU CONVERSION ARCHITECTURAL SHEET DESCRIPTION 12/15/11 APPLIED COMMENTS FROM M. SEAY PG Cl—COVER SHEET PG GN— GENERAL NOTES PG Al —FIRST FLOOR PLAN PG AlA—FLOOR PLAN SECTIONS/DETAILS PG A2—SECOND FLOOR PLAN PG A3H—FRONT & REAR ELEVATIONS "H" PG A4H—LEFT & RIGHT ELEVATIONS "H" PG El —FIRST FLOOR ELECTRICAL PLAN PG E2—SECOND FLOOR ELECTRICAL PLAN PG P1—FIRST FLOOR PLUMBING PLAN PG P2—SECOND FLOOR PLUMBING PLAN PG DI —DETAILS PG D2—DETAILS PG D3—DETAILS PG WAl —WALL ASSEMBLY DETAILS PG WA2—WALL ASSEMBLY DETAILS PG WA3—WALL ASSEMBLY DETAILS PG WA4—NOT USED PG WA5—NOT USED PG WA6—WALL ASSEMBLY DETAILS OIA5118 RID SET ISSUED 02/13/18 ADDED ELEV. U t 'K' WITH SIDING PER MARK 50WES 02/20/16 51D SET RE -ISSUED 04A1/18 FOOTING REVISIONS PER M. 50WES 08AII18 ADDED VALLEY FRAMING DETAIL, UPDATED 5OLLARD DETAIL 01/26/19 DETAIL- 'ADDING BAR TO BOND SEAM' ADDED TO 612A 02l26A9 PLAN MAINTENANCE 03/29/19 REVISED LINTEL SIZE AT FRONT ENTRY DOOR 04/25/19 ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON STATE OF FLORIDA PROFESSIONAL ARCHITECT: 7� MICHAEL C. ANDERSON AR N o . 17305 A.B. DESIGN GROUP LLC 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FL 32937 Tel: (321) 802-3591 SQ FT CALC 'S 04/25/19 REVISED HVAC VOLUMES ON SQFT CALC SCHEDULE IST FLR. LIVING 1104 SQ, FT. 2ND FIR. LIVING 1501 SQ. FT, TOTAL LIVING 2605 SQ. FT. GARAGE 43'1 SQ. FT. PORCH III SQ. FT. COVERED LANAI 80 $0. FT. TOTAL 3233 SQ. FT. A/C VOLUME 22403 CU. FT. 04/26/19 UPDATED LEDGER BOLT SIZE a SPACING 06/19/19 REVISED I -JOIST LAYOUT ADDED LED LIGHTS TO KITCHEN t BATHROOMS PER MARK BOWES 013/13/19 LEDGER BOLT SPACING REVISED II/t5/19 ADDED COCOA PLUMBING RISER 01/01/20 REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS 05/11/20 REVISED STAIRCASE AND STAIR SECTION DETAIL 01/01/21 2020 F5C UPDATE STRUCTURAL SHEET # DESCRIPTION PG Sl—FOUNDATION PLAN PG S1.1A—DETAILS PG S1.2—FIRST FLOOR DOWEL PLAN PG S1.2A—DETAILS PG S2—FIRST LIFT BEAM PLAN AND NOTES PG S2.1A—DETAILS PG S2.2A—SAFE LOAD TABLES PG S3—FIRST FLOOR FRAMING PLAN PG S3.1A—DETAILS PG S3.113—DETAILS PG S3.1C—DETAILS PG S4—SECOND FLOOR DECK PLAN PG S4.2—SECOND FLOOR DOWEL PLAN PG S5—SECOND LIFT BEAM PLAN AND PG S5.1A—SAFE LOAD TABLES PG S6—ROOF FRAMING PLAN PG SN1—DETAILS NOTES DRAWING � CONTRACT DOCUMENT REVIEW BY BUILDER THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. IF ANY ASPECT OF THE CONSTRUCTION (AS DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND IN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE OONSTRUCTION BASED ON THE DRAWING SET. 2$94 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W 0 h U W A F A [ti ti SVHDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: COVER SHEET 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 r"1S11N-1- 10 28 21 DATE: / / SCALE: 1/4"=11— 0" SHEET GENERAL NOTES SITE WORK TIMBER 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED 7th EDITION, (2020) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER HEREIN: FBCR 7TH EDITION (2020) UNO. 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL B. NATIONAL FOREST PRODUCTS ASSOCIATION: 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY FINISH GRADES, PLANTING AND IRRIGATION. C. SOUTHERN PINE INSPECTION BUREAU: THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER DESIGNED AND INSTALLED IN ACCORDANCE WITH FBCR 2020 CHAPTER 3, SECTION R301.2.1.2. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE D. TRUSS PLATE INSTITUTE: ARCHITECT. I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014) 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK E. APA - THE ENGINEERED WOOD ASSOCIATION: PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN''/z THE HORIZONTAL I. ENGINEERED WOOD CONSTRUCTION GUIDE DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. 5. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR AND COMPACT MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557 2012 E1. THE 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. FABRICATION OF THE WORK. BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION, 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ. SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING 8. EXCAVATIONS TO BE A MINIMUM OF T- 0" BEYOND NEW FOOTING LINE. CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. PLUMBING 9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL, 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REQUIREMENTS. 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 3. CONDENSATION LINES SHALL BE MINIMUM %" PVC (SCHEDULE 40), INSULATED WITH AMAFLEX. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 10. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 2.5 GPM EACH IN ACCORDANCE WITH WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND THE FBCR TABLES 2903.1 & 2903.2. 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. COUNTY BUILDING AND ZONING CODES. 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. GARAGES AND CARPORTS 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. 11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO FBCR SECTION P3005.2. 1. GARAGE DOOR A. ENGINEERED FOR MIN. WIND LOAD, LISTED COVER SHEET DRAWING. 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO FBCR SECTION P2903. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER 12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF FBCR SECTION P2603.2. BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION 2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE EXTERIOR WALL COVERINGS PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH FBCR TABLE R301.2(2) AS MODIFIED BY FBCR 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS. "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE AGRICULTURE AND CONSUMER SERVICES." EXTERIOR FINISHES DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL 1" MIN. RIGID 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS GARAGE. THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH 4. AS PER SECTION R302.6 &TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT ASTM-C926-18b, ASTM-Cl063-19a & ASTM-C1787. LESS THAN '/2 -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE 3. LATH & ACCESORIES PER ASTM-C-1063-19a & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE "L" FLASHING HORIZONTAL LATH AND PAPER DETAILS PROTECTED BY NOT LESS THAN''/2-INCH GYPSUM BOARD OR EQUIVALENT. PIPE PENETRATION DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS 4. SHALL BE INSTALLED PER ASTM-C1063 -19a AND R703.7. Reviewed for Code Compliance Universal Engineering FIRE RESISTANT CONSTRUCTION sciences UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7. EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) . CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AB DESIGN GROUP'S SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S/CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. CONTROL DATE: 09/08/21 (CM) 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F w 04 U w 0 F w A F A SU13DIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: GENERAL NOTES 160 MPH EXP. jC ARCHITECT STATE OF FLORIDA NOV 1 6 2021 MrAiAEL C. ANDERSON AR NO 17305 PRINT 2128 DATE: 10 / / SCALE: 1/4"=1r-0" SHEET G GROUND WIND DESIGN SEISMIC SUBJECT TO DAIf IAGE FROM WINTER ICE BARRIER FLOOD AIR MEAN SNOW SPEED TOPOGRAPHIC DESIGN r WEATHERING' FROST L INE TERMITE DESIGN UNpERTLAYMENT HAZARDS e FREEZING ANUAL LOAD (MPH) EFFECTS' CATAGORY DEPTHb TEMPO REQUIREDh INDEX' TEMP NA 160 C NA NEGLIGABLE NA VERY HEAVY 42 NA SEE SURVEY NA NA FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTION FBC R302.9.1 THROUGH FBC R302.SA FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN 21'-10, ACCORDANCE WITH SECTION FBC R302.10.1 THROUGH FBC R302.10v 13R'052-SH Efl 12'-4" BEDROOM #2 8'-B' CLG. --- (2) 2068 39'-8" (2) 3052-SHE LIMG ROOM V-8' CLG. -10" 3 RI i 'R %JJJIP!/JJJJJ/ 3'-411 GARAGE 8'-8' CLG. I -f "Grp,' LLSS , B 5 40' GABLE ROOFS WALLS O s 1 W -Q ` f f . I ♦ ' ..-.. L ; I f , fV 300 y /q 0�y saw 450 4 4 1 �r nl GABLE ROOFS i0° < 0 5 45" HP ROOFS 10°<9s30' Fat SI; 1 foot = 3044 nom I de'g= 0:017$ ml Node; a - 4 fev in all uses. FIGURE R301.2(7) COMPONENT AND CLADDING PFIFSSURE ZONES 10'-0" '-10" -4" l'-4' 7L COVERED I LMAI 8'-8' CLG. 10, 0 I I � I I I I 6068 S.G.D. \ I 271-4"1 %JIJJJ/JJJJJJI//JJ//JJJ � 1, , - �� ' I B 1 III FOYER 9 viii� FLEX 8'-8' CLG.m III 8'-8' CLG. III 3068 � III W/12' III TRANS III 1G 2'-10' -0" 1 411 (2) 3052-gH� PORCH I 0 :4 8'-8' CLG. I N I 10'-0' 19' -4' CWONENT AND CLADDING WIND LOADS BASIC WIND EXPOSURE FOR 3 SECOND GUSTS OPENINGS AND TYPE SQUARE FOOTAGE ZONE 160 MPH WIND Mit) RE wS MIN. WINDOW CRITERIA 10 5 31/-50 EXTERIOR SWING DR MIN. CRITERIA 18 5 36/-41 S.G.D. MIN. 41 5 34/-43 CRITERIA 16010 O.WD. 112 5 31,0/-34.6 12'x12" SOFFIT 1 5 313/-49.9 BASIC WIND SPEED MPH = 160 (Volt) INTERNAL PRESSURE COEFFICENT = f 0.18 BLDG. CAT.=II, EXP.=C, MEAN ROOF HT. = 22'-8" PRESSURES HAVE BEEN MODIFIED PER FBCR 7TH ED. (2020) SECTION R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. CONMOL DATE 01/01/21 TRUSS DOUBLE TOP PLATE-� SP4s32' O.C. MAX IST FLOOR STUDS TO 2ND FLOOR STUDS SIMP9ON META-% 32' OO. MAX 2x CONTINOUS STR288 BLOCKM MID WALL 2x STUDS • 16. OO. MAX, UOM LTD ♦ G SUBFLOOR GLUED AND SCREWED AS PER FASTNER SCHEDULE PRE-ENG FLOOR TR1" DOUBLE TOP PLATE 2x STUDS • 16' O.C. MAX uox 2x CONTINOUB STREW SECURE BT. PLATE TO STUD BLOCKMG MID WALL SIMPSON SP4 032' O.C, MAX SECURE BT. PLATE TO 8L W/ I'xv ANCHOR BOLT W/ wi AB 2' WASHER I' EMBED. MM. • 32" HEIGHT OF GARAGE O.C. MAX, EPDXY NOT VARIES WITH SLOPE REQUIRED FOR EXPANSION BOLTS w a SIMPSON SP4 • 32' O.C. MAX d;0 4' CONC. REINFORCED W/ 6°x6' WI.4XILu I UAIF OR FIBER t*T6W ON 6-MIL. VAPOR z E RETARDER ON WELL -COMPACTED CLEAN E FILL. TERMITE TREATMENT TO BE in Ou 4' 1-0. 4' 4' BORA-CARE APPLIED AT FRAMING. (2)'S WEAR ON CHAIN SCALE: 1/2' = I'-O' FIRST FLOOR PLAN SQ.FT. CALL. S IST FLR. LIVING 1104 SQ. FT, 2ND FLR. LIVING 1501 SQ. FT. TOTAL LIVING 2605 SQ. FT. GARAGE': 43l SQ. FT, PORCH III SQ, FT, COVERED LANAI 80 SQ. FT. 737AL 3233 50, FT- A/G VOLUME 22403 CU. FT. I� M ASONRY FRAME LL LEGEND BLOCK WALL ON PLANS BRCS. HG7. VARIES 8' BLOCK WALL UN.O ON PLANS 18'-8' BRCS. INTERIOR LOAD BRG. WALL U.N.O. jONN FLAN S I 4' INTERIOR NON LOAD BRG. WALL U.N.O. ON PLANS -ALL INTERIOR DOORS TO BE -ALL EXTERIOR DOORS TO BE (o'-8' UNLESS NOTED OTHERWISE Revieww for Code Compliance Universal Engineering Sciences SCALE: 1/4' = 1'-0' NOTE: -2-6 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-8 SOLID DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. -VERIFY CONDENSER PAD LOCATION WITH SITE PLAN -OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL_ BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/5' (35 MM) IN THICKNESS, SOLID OR HONEYCOMB -CORE STEEL DOORS NOT LESS THAN 1 3/6' (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. -THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE 4 ITS ATTIC AREA BY NOT LESS THAN liz'(12-lmm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS BY NOT LESS THAN r'%"(15.9mm) TYPE X GYPSUM BOARD OR EQUIVALENT. -UNDER STAIR PROTECTION: ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WAI-LS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 INCH GYPSUM BOARDS- FBCR 2020 (ITH ED.) 302.1 - EGRESS NOTE: DO NOT SHUTTER FRONT DOOR. FRONT ENTRY DOOR TO BE EGRESS POINT WHEN THE HOME IS SHUTTERED. - REFER TO BUCKING DETAILS FOR BUCKING AND RO NOTES. -FRAMED WALL SEPARATION BETWEEN THE UNCONDITIONED GARAGE AND CONDITIONED SPACED SHALL HAVE AN INSULATION R VALUE OF R-13. -CEILING R VALUE TO BE R-30 INSULATION ABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS ARE PROVIDED BY THE PVAC CONTRACTOR AND ARE OF THEIR CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SE U-VALUE AND SHCG ARE INFORMATION PROVIDED BY THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS A��i' mom mom 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com F w 0 U w a w 4 h A ti SUBDIV. 8c LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR PLAN 160 MPH EXP. C ARCHFrECT. STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON A,R IVO 17305 PRINT 21 28 DATE: 10 / / SCALE: 1/4"—l'-0" SHEET Al I' 4" DSL. TOP PLATE F A BAR -DETAIL ARCH DTL. B SCALE: 10'-0 3/4" 2ND FIN. FLR. 8'-8" BRGz HGT. 42' HIGH HALF WALL W/ GAP 3/4' TtG SUB FLOOR GLUED t SCREWED PER FASTENER SCHEDULE PRE-ENG'D FLOORING SYSTEM (SEE FLOOR FRAMING SHEET) NOTE: STAIRS RISERS TO CONFORM TO FBCR ITH EDITION (2020) MIN. TREAD•10' MAX. RISER -'I 3/4' 3/1&s' MAX. VARIATION IN RISERS/TREADS ADJACENT TO EACH OTHER 3/8' MAX. VARIATION IN ANY RISER/TREAD HANDRAIL CIRCULAR CROSS SECTION DIA. TO BE 1 1/4' +-1/4' OR PROVIDE EQUIVALENT GRASPABILITY WINDERS- MIN. W WIDE NARROW END MIN. 11' WIDTH * 12' FROM NARROW END 34' MIN, HANDRAIL HGT. NOTE: ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2' GYPSUM BOARDS. FBCR 3021. ii o STAIR DATA: I&R m IB4' 15 TREADS g 10'+ I' NOSING (2) LAYERS OF 3/4' PLYWOOD OR (2) LAYERS OF 3/4' SUB FLOOR MATERIAL RIPS FOR SOLID NAILING SECURE TREADS TO STRINGER WK3r08 3' SCREWS * EA STRINGER, UNTHREADED SHANK TO EXTEND BEYOND THICKNESS OF SUB -FLOOR SHEATHING STOR. ` 3-2x12 SYP STRINGER REINFORCED W12X4 SPF W/CONT. BEAD OF SUB -FLOOR ADHESIVE PL-400 OR SIMILARE * EA HORIZONTAL RUN 2 X 4 RE-INFORCING * EA. 2 X 12 STRINGER SECURE W/12d W-8' O.G. 42' H. 1/2 WALL W/ CAP -3/4' KICK PLATE " MAX. 10„ NOSING MIN. \ oe wW \ zQ \ � W \ t0 w \ U 2X4 ATTACHED W/ 10d MASONRY NAILS * 2X4 P.T. SLEEPER INTO SLAB WITHIN 8' OF EACH END, 32' O.C. MAX. STAIR SECTION I�'II to] HANDRAIL 6 36' W1 2X4 RE-INFOR THE CLEAR SPACE BETWEEN THE HANDRAIL AND THE WALL SHALL BE NO LESS THAN 1 1/2" AS PER FBCR R3111.02 NOTE: HANDRAIL ENDS SHALL BE RETURNED TO THE WALL OR TERMINATE INTO A NEWEL POST. NOTE: 1. HANDRAILS SHALL HAVE EITHER A CIRCULAR CROSS SECTION WITH A DIAMETER OF 14"+ 2" OR A NONCIRCULAR CROSS SECTION WITH A PERIMETER DIMENSION OF AT LEAST 4" BUT NOT MORE THAN 6 1/4' AND A LARGEST CROSS SECTION DIMENSION NOT EXCEEDING 2 1/4". EDGES ° SHALL HAVE A MINIMUM RADIUS OF 1/8°. O�� * m 2. THIS RAILING SYSTEM IS DESIGNED TO RESIST A LOAD OF 50 PLF FORA CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AT THE TOP OF SUCH BARRIERS AT ANY LOCATION ON THE SAFEGUARD, WHICHEVER CONDITION PRODUCES THE MAXIMUM STRESSES- PER SECTION 1601a] / F.B.G. 2020 D !HIA4NDRAIL SECTION 1% : 3/4'=1'-0' Reviewed for Gode Compliance Wd Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U w 0 a a C1 w 4 F A ti SvsDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEI • 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: FLOOR PLAN SECTIONS / DETAILS 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA Nov 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 10 28 21 DATE: SCALE: 1 /4"=1' - 0" SHEET AIA I N r N N 3052-SH rFnwRSS 39' _a" 2'-4" 11'-4" 2'-4" 12'-0" 14'-0" r (2) 3052-SH I3052-5H FnRESS ® I fl I 0 I^ �I _I BEDROOM #5 UPSTAIRS I BEDROOM*[ a' -a' GLCx. ' ® _ LIVING 8'-8° CLCs. S' 8' CLG, ❑ 3: e2I/4'- e I ,yv 12'-0" 4'-0" 3'-8" 6 -0, V. o r----- ir— -i pPT c i c I BATH #3 7 711 10 11 i 0. iii W. II • TO I T F • R - - -- \fR/A Q� TUB/ V IR- L61 tt HW m r I - -- r t �s s I.C. t 1 1 Ln m o 3'-4' BEDROOM#1 C V 21-4" 8'-S' CLCx. `' 14'-0" Cj 8 6'-6" m060 2'-4" 3'-0" 4'-4" LAv. BATH#1 I BEDROOM #3 LAv. ENCL 71 ry�o � _ I I r a I \ I (2) 3052-5 [] o a I W.I.C. EGRESS 6Frl 2040-SH a 3052-SH 3052-5 EGRESS EGRESS I LINE OF: IST I— — --- FLOOR BELOW — --- ---- -v -1'-0" -4" 5'-4° 8' 0 10'-0" 2'-4" 2'-4" 13'-4" �r N 11 Rowowee for Cade Univenya! CQmErvineerin sciences ff -FRAMED WALL SEPARATION BETWEEN THE UNCONDITIONED GARAGE AND CONDITIONED SPACED SHALL HAvE AN INSULATION R VALUE OF R-13. -CEILING R VALUE TO 5E R-30 INSULATION ABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS ARE PROVIDED BY THE HVAC CONTRACTOR AND ARE OF THEIR CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SET, U-VALUE AND SHCG ARE INFORMATION PROVIDED 5Y THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS � : mim0 ■ow v 0' mommm R—VALUE SCHEDULE FLOOR SLAB ON GRADE R-0 EXTERIOR WALLS CMU - INT INSUL R-4J FRAMED WD - ADJACENT R-13 FRAMED WD - EXTERIOR R-13 CEILING UNDER ATTIC R-30 2194 HWY A1A, SUITE 301 INDIAN HAFIBOUR BEACH, FLORIDA 32937 PH: 329: 802-3591 www.abdesigngroup.com AA #: 0003325 h W W U W O rn rn W A F q P : 8e LOT:KSIDESE 2 #101T01 101R1HB HAYDEN" GARAGE SWING: LEFT PAGE: SECOND FLOOD PLA]N� 160 MPH EXP. C ARCHITECT- _ STATE OF FLORIDA NOV 1 B 2.021 MICHAEL C. ANDERSC►N AR NO 17305 ._Z%."14 1 2128 DATE: 10 / / SCAT :1 /4"=1' — 0" 2(o'-8' BLDG. HCT. 18'-8" 2ND FLR_ BRG. HCsT. 4' RAISED BAND 6' RAISED BAND 10'-0 3/4" _ 2ND FIN. FLR. 8'-8" CLCs. HCxT. -- OPT. COACH LIGHT 0'-0" FIN. FLR. -`" I� 0. rpm r -------------------- 1�5 F NT ELEVATION N SCALE: 114 = V-0' TEXTURED FINISH NOTE: WALL FENESTRATION FLASHING AS PER FBCR R103.4 OFF RIEN3E VENT 18'-8" 2N1) FLR.,, _ BRCz. HCsT_ 10'-0 3/4" 2ND FLR.01L 12 FIN. FLR./BRCz. HraT. - - - - - - - - - - - - 8'-a" CLCs. HCzT. - - - - - - - - - - 0'-0" FIN. FLR. _ I m F F?TAR, ELEVAT10"N SCALE: 1/4 = I'-0' TEXTURED FINISH 5H INCaLE ROOF FYPON 16'X48' DECORATIVE SHUTTER OR EQUIVALENT 2ND FLR. "15RG. I-Ir;;T. I I FYPON I I BKT11X1'l OR EQUIVALENT I I 6' RAISED I I BAND (TYP.) —2ND FIN. FLR. _ j4'-8" BRCx. HCiT. ENTRY I I I I I I 4B I14,JA3 I I TYP. 4' RAISED I I BAND (TYP.) I 1 I 5" RAISED I I BAND (TYP.) I I ,0'-0" FIN. FLR. IRV _�18'-8" 2ND FLR. �'BRCs. HCsT. I I I I I I I I I I I I I I I I I I I _ 010' 0 3/4" 2ND FLR. -- r FIN. FLR./BRS- HCzT. -a" CLr5. HG7. I I 4B I A3 I I I I TYP. I I I I I I I I I I I I ,i0'-0" FIN. FLR. MODEL 2605-HAYDEN-4EHB (2-Story) AREA OF ATTIC = 1541 SQ. FT. NET FREE VENTILATION AREA REQUIRED 1/ 300 REQUIRED VENTILATION AREA = 1541 /300 = 5.14 SQ. FT. 5.14 = 739.68 SQ. IN. MIN. REQUIRED VENTILATION = AX 739.68 IN UPPER PORTION OF ATTIC = 295.872 SQ. IN. (BALANCE TO BE PROVIDED IN SOFFIT VENTS) OFF RIDGE VENTILATION AREA = 138 SQ. IN. PER VENT (net free area) TOTAL# OF VENTS REQUIRED = 2.14 TOTAL# OF VENTS PROVIDED = 3 SOFFIT VENTILATION AREA 7 SQ. IN. PER LINEAR FT (netfree area) LINEAR FEET OF SOFFIT REQUIRI 42.27 Reviewed ror code 91 camw;e,+ce Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W N yF U ro W A F q SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: FRONT & REAR ELEVATION "H" 160 MPH EXP. C ARCHITECT STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 8 21 DA102TE: / / SIC ALE• 1/4r'=1'-0" SHEET M) Z 0 FRAME DOWN FOR FYFON 15KTIIXII OR EQUIVALENT IS'-8" 2ND FLR. BRG. HGT. 10'-0 3/4" 2ND FLR. FIN. FLR./BRG. HGT. S'-8" BRG. HGT. ENTRY 0'-0" FIN_ FLR. LSE -VT ELE V TIO SCALE:: 1/4 = I'-0' TEXTURED FINISH RIGHT L ATION SCALE: 1/4 = 1'-0' TEXTURED FINISH ,418'-v 2ND FLR. BRG.I4GT. _ 10'-/4" 2ND FLR. FIN. FLR. BRG, HGT. ENTRY '-0" FIN. FLR. 2ND FLR, BRG. HGT. ,`10'-O 3/4" 2ND FLR. FIN. FLR./BRG. HGT. o5'-8" CLG. HGT. _oO'-O" FIN. FLR. Rehm 3ci���a 6erin� 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W 0 F ti U 4 F A E: ti SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: RIGHT & LEFT ELEVATION "H" 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 10/28/21 1 SCAT E:1/4"=1'-0" SHEET A4FI ELECTRICAL LEGEND SYMBOL DEFINITION NOTES 125V OUTLET 20 AMP SINGLE POLE 110V OUTLET 110V OUTLET 1/2 OF OUTLET WIRED TO SWITCH GFI 110v OUTLET D W/GRND PAULI INTERUEQUIPI MTERLIPTER (TAMPERER RESISTANT TYPE) 220v OUTLET (4) WIRE CONNECTION WExT. WATERPROOF GROUND FAUL T I OUTLET INTERRUPTER SWITCH SWITCH 3-WAY OPER. �4 SWITCH 4-WAY OPER. WALL MOUNTED LIGHT CEILING LIGHT O LED CLG LIGHT O VP LED VAPOR PROOF LIGHT O VP VAPOR PROOF LIGHT ORECESSED CAN VENT. FAN I CFM PER SQ FT. WENT. FAN W/LIGHT 1 CFM PER $a FT. I VANITY LIGHT FIXTURE (SPEC'$ TBD BY BUILDER) 4 FLUORESCENT 2-BULB WRAP LIGHT AROUND CRECESSEDI ® FLUORESCENT CENT LIGHT 2 BULB WRAP AROUND (SUREMNT.) 2' FLUORESCENT 4'FLUORESCENT 4 a0 a 4' TRACK LIGHT PANEL g METER BAIT. BACK-UP OSMOKE S.D. DETECTOR w/ HARDWIRE WALL MOUNTED BATT. BACK-UP $D SMOKE DETECTOR w/ HARDWIRE ® a/CO CARiSCN MGNOXIDE SMOKE DETECTOR MATT. BACK-UP W/ HARDWIRE INTER -CONNECTED COMBO SHALL BE A DISTANCE OF NOT LESS THEN 4' FROM WALL PENDANT LIGHT L� NATURAL GAS r1/ OUTLET ` TELEPHONE JACK WATER HEATER IGNITION SOIRCE TO BE ELEVATED DISCONNECT A/ AIR CONDITIONING TO E V U.N.O.DISCONNECTTHIS SEE EKI ON SHEET TV TELEVISION JACK CEILING BOX REQUIRED TO BE SUPPORTED IN O J-BOX ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION CEILING BOX REQUIRED TO BE SUPPORTED M CEILING FAN/LKsHT ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION �a4 24' INCANDESCENT LIGHT STRIP nno 36' INCANDESCENT LIGHT STRIP nnnnnnnn 0 48' INCANDESCENT LIGHT STRIP FLOOD LIGHT KP OPT. SECURITY KEYPAD HE P.B. PUSH-BUTTON FOR CHIMES sue. USB PORT • LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO BE VERIFIED a HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF FBCR ITH EDITION (2020) 4 NEC 21012 2011 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GrI • ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 50 CFMI INTERMITTENT PER ELECTRICAL PROVISIONS OF SECTION 1`115013 FBCR "ITH EDITION (2020). • LAUNDRY ROOM AND DISHWASHER RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL BE NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF i BCR'ITH ED (2020). • ALL WORK TO COMPLY WITH ELECTRICAL PROVISION$ OF THE FBCR 'ITH ED (2020). • ALL SHALL LAMPS BE SELECTED BY BUILDER AND 15% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER F.BrENERGY C41AERVATION (RESIDENTIAL ENERGY EFFICIENCY) 2020 'ith EDITION R4041 METER FIELD VERIFY LOC. GF I IRRIGATION OUTLET a 48' AF.F, N PRE -WIRED CLG FAN 4, Cam' `J BDRM. #2 S.P. BATH #2 GFI aT 44' A.FF. BOLLARD, AS REQ. PER BLDG. CODE WH W COACH LIGHT P DOOR 1 I / KEYLESS FIXTURE GFI GARAGE DOOR PREUUIRE GARAGE ROOM PRE -WIRED CLG FAN I I I � 1 I I TO 2ND FL.\ SUUITCH IN SUUITCH \ CABINET I I --- OUTLET FOR DLU I I )R I ,; I GF 1 to 44' A.F.F. ' 5/CO COVERall LMAI I CEILING MTD. LIGHT TO BE INSTALLED, UJIM GFI J-BOX FOR / I OPT. FAN � I ROOOOMG GFI L L II I II \ I ' K rrm `z'� I OR VENT I I ® I 0 OR MICRO / i I L 'Kill �- L GFI PAN. GFI IOPf.--- - IM— i RE�I E-_7 I III \ III FM III•'. .`. �` III �'• •J FOYER III PRE-Iu1RED CLG FAN !III r GF I I / P.B. FOR CHIMES I PORCH ------ ------ FIRST FLOOR ELECTRICAL PLAN 11 ;,1 11_'All I I I I LED LIGHTING SINGLE LAV. BATH 42 WP Panel MAIN - A PANEL: 8/16 wp crt. breaker VOLTAGE: 120/ 240 V -1Ph MAIN: 150Amp M.C.B FEEDER: 3- #1 Cu THWN & 1- #6 Cu (G) in 1 1/2" C. OR 3- #2/0 AL THWN & 1- #6 Cu (G) in 1 1/2" C. Wire Pole I Bkr Description Watts Circuit ..Circuit Watts Description Bkr Pole Wire #12 1 F20 Exteror Receptacle GFI for TUG 1200 1 2 :Space #12 2 _ 20 Inigation.Pump 1000 3 4 Space 5 6 6240 A/C C.U. 40 2 #t8 Space 7 8 PANEL - A PANEL: 42 crt. breaker VOLTAGE: 120/ 240 V -1Ph MAIN: 150Amp M.L.O. FEEDER 3-#1CuTHWN&1-#6Cu(G)in11/2"C ORB-#2/0ALTHWN&1-#6Cu(G)in11/2"C. Wire Pole Bkr Description Watts Circuit 1 Circuit Watts Description Bkr Pole Wire # 12 1 20 Small Appliance 1500 1 2 8000 Range 50 2 #6 # 12 1 20 Microwave / Hood GFI 1800 3 4 #12 1 20 Small Appliance 1500 5 6 4500 Water Heater 25 2 #10 # 12 1 20 Refrigerator 1500 7 8 # 12 1 20 Dining Receptacles AFCI 1500 9 10 1200 Disposal GFI 20 1 #12 #12 1 20 Bath GFI Receptacles 1200 11 12 1500 Dishwasher GFI 20 1 #12 #14 1 15 Foyer/ Flex / Hall AFCI 900 13 14 5000 Dryer GFI 30 2 #10 #14 1 15 Limng Pm, Lanai, Kitchen, Din. Lts AFCI 900 15 16 Space 17 18 1500 Washer GFI 20 1 #12 #14 1 15 SD & C/O AFCI 900 19 20 1000 Garage Door Opener GFI 20 1 #12 Space 21 22 1200 Garage Lts & Receptacles GFI 20 1 #12 #14 1 15 Bedroom #2 / Bathroom #2 AFCI 900 23 24 900 Ownel's Suite AFCI 15 1 #14 #14 1 15 Bedroom 43 AFCI 900 25 26 900 Owner's Bathroom AFCI 15 1 #14 #14 1 15 Bedrooms #41 Opt. Bed #5&#6/ Opt. Loft AFCI 900 27 28 1200 2nd Floor Hall/ STD 2nd FL Liv./ Laun. AFCI 20 1 #12 #12 1 20 Exterior Lights and Recept GFI 1000 29 30' 1000 Irrigation controls only 20 1 #12 Space 31 32 Space Space 33 34 Space Space 35 36 Space Space 37 38 Space #8 2 35 A/C A.H.U. (Heater 5 KVA at 65%) 5625 39 40 Space 41 42 Space Load subject to demand factor calculations / line 17600 r 27900 Load subject to demand factor calculations / line Demand Factor Calculations: ABBREVIATIONS: AFCI: ARC FAULT CIRCUIT INTERRUPTER NC: NON COINCIDENT LOAD GFI; GROUND FAULT INTERRUPTER Total load subject to demand factor 45500 First 10000 watts at 100% 10000 Remaining watts at 40% 14200 Total A/C load 11765 LOAD CALCULATION IS BASED ON A#C NON -COINCIDENT LOAD Total Connected Load Watts 35965 Total Amps (watts / 240 volts) 149.9 NOTE. I. ELECTRICAL PLAN SHALL BE USED FOR ELECTRICAL FIXTURE COUNT AND GENERAL LOCATION AS REQUIRED BE FLORIDA BUfLDING CODE AND DESIGNATED IN VALUE IN NEC Ism AMP ELECTRICAL RISER NOT TO SCALE. GENERAL NOTES: A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR TTH EDITION (2020). LOCAL CODES, AND ALL LOCAL POWER COMPANY REQUIREMENTS. B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS NOTED OTHERWISE. POWER COMPANY TRANSFORMER GRADE PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - ELECTRICAL SERVICE. PROVIDE 3 "1 COPPER (Cu) IN 1-1/2'' DIA SCHEDULE SO PVC CONDUIT OR PROVIDE 3 1'2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE S0 PvC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. figNaviewed for C ode Compliance Unive al Engineering rip PROVIDE 3112/0 CU, THWN + 1% CU IN 2' CONDUIT OR 3 04/0 AL, THWN + 1% CU IN 2' CONDUIT OR 2/0 AL. S.E.R. (CONDUIT TO TERMINATE ABOVE SOFFIT O OVERHANG.) COMBINATION SERVICE DISCONNECT SWITCH AND M ELECTRIC METER IN NEMA 3R ENCLOSURE 150A/2P MCB TELEPHONE SERVICE ENTRANCE EQUIPMENT INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS 150 AMP P/240 VOLT I PHASE MLO PANEL CABLE TELEVISION SERVICE ENTRANCE EQUIPMENT 1 •4 CU SERVICE GROUND CONNECTED TO CONCRETE ENCASED FOOTER STEEL PER ELECTRICAL PROVISIONS O= THE FBCR TrH EDITION (2020), 5/611 DIA X $ FT Li�NG COPPER GLAD GROUND ROD 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F 04 U W O F V W A F A ti SVBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR ELECTRICAL PLAN 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 DATE: : 10/28/21 DATE: SCALE: 1/4 "=1' — 0" SHEET El ELECTRICAL LEGEND SYMBOL DEFINITION NOTES —� 125V OUTLET 20 AMP SINGLE POLE 110V OUTLET 110V OUTLET 1/2 OF OUTLET WIRED ���J// TD SWITCH GFI 110V OUTLET EQUIPED W/GRND FAUL INTERUPTER(TAMPER M515TANT TYPE) 220V OUTLET (4) WIRE CONNECTION WP EXT. WATERPROOF GRO� LT GPI OUTLET I SWITCH SWITCH 3-WAY OPER. lt4 SWITCH 4-WAY OPER. WALL MOUNTED LIGHT CEILING LIGHT ® LED CLG LIGHT O V� LED VAPOR PROOF LIGHT vp VAPOR PROOF - �; / LIGHT ORECE66ED CAN VENT. FAN I CR I PER $R FT. VENT. FAN W/LIGHT I CRI PER e'a FT. VANITY LIGHT FIXTURE (SPEC'S T50 SY SUILDER) 4'X2' FLUORESCENT LIGHT 2-SULB WRAP AROUND (RECESSED) 450- FLUORESCENT 2-SULS WRAP ® LIGHT AROUND (SURFACE MN-rd 21FLUORESCENT 4'F-LUORE$CENT 1 4' TRACK LIGHT r�-�- LS PANEL METER O$�. SMOKE DETECTOR W1 HARDWIRE WALL MOUNTED BATT. BACK-UP $.D 5MOKE DETECTOR W/ HARDWIRE ® cJ/CO CARBON MONOXID SMOKE DETECTOR BATT. SACK -UP WJ HARDWIRE INTER -CONNECTED CdMBO SHALL 5E A DISTANCE OF NOT LESS THEN 4' FROM WALL -- PENDANT LIGHT NATURAL GAS OUTLET TELEPHONE JACK WH WATER HEATER IGNITION SOURCE TO 5E ELEVATED DISCONNECT A/C AIR CONDITIONING TO � UNO. SEE ON DISCONNECT T44I6 SHEET TV TELEVISION JACK CEILING 5Ox REQUIRED OJ-50X TO 5E SUPPORTED IN ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION n CEILING SOX REQUIRED TO 5E SUPPORTED IN CEILING FAWLIGHT ACCORDANCE W/ 50X MARKED AS SUCH FOR INSPECTION 24'INCANDESCENT LIGHT STRIP n 36" INCANDESCENT LIGHT STRIP n�nnnnnn 48" INCANDESCENT LIGHT STRIP �= FLOOP LIGHT OPT. SECURITY KP KEYPAD FE P.S. PUSH-5UTTON FOR CHIMES a--+ U55 PORT • LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO BE VERIFIED m HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF F5CR 1TH EDITION (2020) 4 NEC 210.12 2011 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GFI ® ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS Or - SECTION 1" 115013 F5CR 1tH EDITION (2020). • LAUNDRY ROOM AND DISHWASHER RECEPTACLE $HALL 5E GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL 5E NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF FBCR 1TH ED (2020). • ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 1TH ED (2020). • ALL LAMPS SHALL BE SELECTED BY VJILDEP 15% OF LIGHTING MUST BE ENERGY EFFIrIENT TYPE FER FB.C. ENERGY CONSERVATION (RESIDEI ITIAL ENERGY EFFICIENCY) 2020. lth EDITION R404.1 p I I— — — — — — — — — — — — — — — — — — — — — — — — — /-----------\ U(g CoJ �I LED LIGHTING DOUBLE LAV. (BATH "3 LED LIGHTING DOUBLE LAV. BATH 01 93 ROWOWed for Code Compliance Universal Engineering Sciences 2194 HWY A1A, SUITE :301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a bd es i gngrou p. c,D m AA #: 0003325 F W W U W a V W A h A II SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 0432L 201 101R1 MODELa 4-EHB "2605.-HAYDEN" GARAGE SWING: LEFT PAGE: �7T� SEiCO1VD FLOOR ELECTRICAL PLAN 160 MIPH EXP. C ARCMTECT- STATE OF FLORIDA PRINT 10 28 21 DATE: /- / SCALE: 1/4 l'— 0" SHEET 1712 2' VTR KITCHEN SINK Ill/ AUTO VENT 2' m'�.�7-- 2- Feld R@lqe C ZY for C 06.0 AUniyagg i6ncq Scienc gas in9 LAv 11 rj-1/2'�-2' 2 3' lly, TUS 3' 2' 2' VTR4k we 1-1/2' LA 2 LAv 2'� Swu)R "'I s� 3• 1 3' 3' CO TO M.aIN PLUMBING RISER DIAGRAM NOTE: PLUMBING LAYOUT PLAN IS INTENDED FOR LOCATING PLUMBING FIXTURES ONLY 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937' PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W W U W 0 F 0. U W A A ti SUSDIV. LOT: CREEKSIDE PHASE 2 L0T #101 PROJECT# 04321.201 101R1 MODET : 4EHB "2605—HAYE)EN" GARAGE SWING: LEFT PAGE: FIRST FLOOR PLUMBING PLAN 160 MPH EXP. C loommommARC® STATE: OF FLORI®A NOV 1 6 2021 MICHAE:L C. ANDERSON AR- NO 17305 PRINT DATE: 10 28 21 SCALE: 1/4"=1'-0" SHEET TD 1 [puftomaaOnrce Scier" Mng L-_-____-._---------------J 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 h W L U W O F U W A h A FF SUBDIV. ee LOT: CR',EEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: ,4EHB "2605- HAYDEN" GARAGE SWI]STG: LEFT PAGE: SECOND FLOOR PL'UMBING :PLAN 160 MPH EXID. C ARCHITECT: STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 PRINT 10/ 28/21 DATE: SCALE: 1/4"=V-01 PER FLR PLAN 1/2' CLG_ 1/2' DRYWALL SECURE BT. — I=LATE TO SLAB W/ 10d MASONRY NAIL 0 32' O.C. MAX 0'-01 FIN. FLIP, 7l/d TP CI AT= 2X4 WOOD STUDS 024' O.G. M 1S8 PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2x4, WHERE SPACED NOT MORE THAN Iro' O.C. OR, NOT LESS THAN 2x�o, WHERE SPACED NOT MORE THAN 24" O.C. TYP. INT. WALL (NO N- BRG. SCALE: 3/4' --1 FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 905.1.1. ROOF SHEATHING: THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FLR. I-0, TYP. 5/6' GYPSUM BI OR 1/2' HIGH STRENGTH CLG. BOARD � 3 5/8, OR 5 3/8" 1/2' DRYWALL TOP CHANNEL (25 GA.) 3 5/8' OR 5 3/8' METAL STUDS 24' O.C. 1/2' DRYWALL 20 GA METAL TO BE INSTALLED IN WALLS 3 5/8" OR RECEIVING UPPER/ 5 3/8" LOWER CABINETS BOTTOM AND TUB/SHOWER 25 CHANNEL GA. METAL TO BE (25 GA.) INSTALLED IN ALL SECURED OTHER WALLS. STUDS TO CONC TO BE SPACED 16' FLOOR W/ O.C. AT 2ND FLOOR 3/4' i'AF < WALLS ADJACENT TO TO WOOD STAIR WELLS AND FLOOR W/ BATHROOM WALLS W/ 1/4' WOOD TILE FINISH SCREW WOOD BASEBOARD--� SEE ENERGY CODE FORMS INSULATION R-VALUES REFERENCE STRUCTURAL PER ELEVATION __�—R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES r-- SPECIFICATIONS REFERENCE STRUCTURAL 1x2 P.T. FURRING — STRIPS A 24' O.G. d 8' CMU ' 1/2' GYP. WL. BD.- c: WOOD BASE a ° n W/ WINDOW OPENING ri 1—STORY FINISH FLOOR TYP. INT. WALL METAL STUDS 1A (NON- BRIG.) nv SCALE: i/2'=I'-O" FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR S05.11, ROOF SHEATHING THICKNESS AS PER SHEET SNi. SECURED PER FASTENER SCHEDULE STRUCTURAL PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT 5" DiA. SLEEVE, DO NOT CUT BOND BEAM SOLID GROUT W/ (D- 05 (2) COURSE 2A)PIPE THROUGH BOND BEAM D1 SCALE: 3/4'=V-0" 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FLR ROOF SHEATHING THICKNESS IS ° ENGINEERED PER ASCE 1-16 IN d ° ACCORDANCE WITH FBCR 2020 ITH EDITION, SECTION R301.1.3 AND 1609.5.1. n TYP. WALL SECTION L NO OPENING NOTE: METHOD TO BE USED FOR THE 1-STORY T4TP BLOCK WALL INSTALLATION OF ROOF UNDERLAYMENT IN ACCORDANCE WITH FBCR 905.1.1.1 OF THE FBCR 2020 ITH EDITION 15 *4 WHICH USES (2) TWO LAYERS OF ASTM D226 TYPE II OR ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT. FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER F15CR'505.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT WALL SHEATHING THICKNESS AS PER SHEET SNI. SECURE PER FASTENER SCHEDULE ON SHEET SNi PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS CAW.K AND SEAL GAS LINE NOT CUT 1 k PVC SLEEVE FOR GAS LM BOND 4MIu. Co. BARS WC= BM6 ti a '4: 2B GAS LINE THRU BLOCK D1 SCALE, 1/2'.I'-O' --2X4 SPF 24' O.C. MAX.--� SECURE W/ (2) 12d NAILS 6 EA. END 2x BLOCKING BETWEEN TRUSSES -PER STRUCTURAL DETAILS -- STIFFBACK AT ALL UPRIGHTS — PER STRUCTURAL DETAILS g 4x. PRE-ENG WD. TRUSS zH PER ELEVATION CONT. 2x RAT RUN SECURED PER STRUCTURAL DETAILS ` SEE ENERGY CODE FORMS FOR - INSULATION R-VALUES PER ELEVATION 5/8' GYPSUM BOARD OR 1/2, HIGH STRENGTH CLG. BOARD 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0" FIN. FLR. .: 81CMU d ° ° a A W WINDOW OPENING R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS m 24' O.G. 1/2' GYP, WL. BD. WOOD BASE 1/2' THICK, 2 COAT - PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY GALV. STEEL L TRACK BRACKETS FASTENED TO WOOD JAM PER PRODUCT GALV.STEEL— APPROVAL REQ VERTICAL TRACK BY MAUR FASTENED TO TRACK BRACKETS W/ PRODUCT APPROVAL. REO. CORNER BEAD a, alu SEE STRUCTURAL FOR REINFORCEMENT 2x& P.T. WP ATTACHED TO PILL CELL AS PER PRODUCT APPROVAL Ma SEALANT 4 HACKER ROD WEATHER STRIP MOULDNG ALL AROUND (BY POOR MAMR) OVERHEAD DOOR BY OTHERS 3 ) GARAGE DOOR JAMBS D1 SCALE: 1 1/2"=11-0' FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 905.1.1, ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE MTL. DRiP EDGE Ax. 2x FASCIA PER "ee!%d ELEVATIONS �niva'�P11a1°de VENTED SOFFIT S`s"na `--WALL SHEATHING THICKNESS AS PER - SHEET SNi. SECURE PER FASTENER SCHEDULE '' ON SHEET SNI. a PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS CMU _ 0'-0' FIN. FLR. ROOF SHEATHING THICKNESS 15 ° ENGINEERED PER ASCE -1-16 IN °., ACCORDANCE WITH FBCR 2020 ITH EDITION, SECTION R301.1.3 AND 1609.5.1. n TYP. WALL SECTION U NO FOPENING NOTE: METHOD TO BE USED FOR THE 1-STORY GABLE BLOCK WALL INSTALLATION OF ROOF SCALE: 3/4'-1'-0' UNDERLAYMENT IN ACCORDANCE WITH FBCR 905.1.1.1 OF THE FBCR 2020 -ITH EDITION IS *4 WHICH USES (2) TWO LAYERS OF ASTM 0226 TYPE 11 OR ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT. Note: WALL FENESTRATION FLASHING PER FBCR 103A - Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the Wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 111. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant Complying with AAMA SOO or ASTM C-920 Class 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, A=4MA 612, or other aF,proved standard as appropriate for the type of sealant. Fluid-ap�:�lied membranes u.54d as flashing in exterior walls shall comply with AAMA -114. The flashing` shall extend to tho surface of the exterior wall finish. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-8023591 www.abdesigngroup.co AA #: 0003325 J W U w 0 F U 4 A FF ST-TBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. C RECT- STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305NIMMOMMMIF J PRINT DATE- 10 28 21 FSCAT 1/4"=1'-0" SHEET DI FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 1305.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE PRE-ENG WD.IRUSS 24' O.C. MAX. METAL DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED - SOFFIT REFERENCE - STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL IX2 FIRE -STOP 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP N 0 a> w /w d) z O E- 4 W ❑a O > fy FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR W5.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE P PRE-ENG WD.TRUSS- EVATION 24' O.G. MAX. METAL DRIP EDGE- BATT INSULATION REFER TO ENERGY CALGS FOR VALUES 2x FASCIA PER- 5/8' GYPSUM BOARD ELEVATIONS OR 1/2' HIGH STRENGTH CLG. BOARD VENTED — 1x2 FIRE -STOP SOFFIT -R-4.1 INSUL. REFERENCE - WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS STRUCTURAL 3/4' T t G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE PER LEVATION OILFER LEVAt10N STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD i PER YELEVATION R-4.1 INSUL. IX2 FIRE -STOP I WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS Q 24' O.C. 8' CMU 1/2' GYP, WL. BD. WOOD BASE GRpf�E ' LINE a .. d x W/ WINDOW OPENING 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY Ix2 FIRE -STOP ATT INSULATION jRI-4,1 EFER TO ENERGY ALGS FOR VALUES ' . ii.011 o.N. TYP.R /8' GYPSUM BOARD 1/2, HIGH STRENGTH LG. BOARD '2 FIRE -STOP INSUL. O > UMre� iak V" a C W S�o W na ti 3/4' T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING SCHEDULE z �0 a> w A m ER LEVATION PER LEVATION 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD Ix2 P.T. FURRING STRIPS ai 24' O.G. 8' CMU a+ 1/2' GYP. WL. BD. WOOD BASE G - d. . n. a m. ''O d G WITHOUT WINDOW OPENING 2-STORY FIRST FLOOR BLOCK SECOND FLOOR BLOCK SCALE: 3/4'=V-0' 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 J F w w 0 F U A F A SUBDIV. 8a LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL : 4EHB "2605— HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 2128 DATE: 10 / / SCALE: 1/4"=1'-0" Ix4 P.T. OR 5/4'X4' MIN. SECURE THRU FRAME 4 EXTEND 1-1/4' INTO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1-1/4' WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING TOP: 2X6 P.T. ® CENTER OF DOOR HEADER SECURED W/ (U 1/2' X 8' J-BOLT W/ 4' MIN. EMBEDMENT W/ 2' X 2' X I/8' WASHER 4 NUT OR W/ (2) 1/2' X 8' ANCHOR 15OLT5 W/ 4' MIN. EMBEDMENT W/ 2' X 2' X 1/8' WASHER 4 NUT - 0 0 TO BLK W/ 0 1/4' TAPCONS ❑m 1 1/2' EMBED., 8' O.C., 4' END DIST., 1 1/2' EDGE DIST. 0 0 2X6 GARAGE DOOR BUCK SECURED W/ (5) 1/2' X 8' J-BOLT OR ANCHOR BOLTS, W/ 4' MIN. EMBEDMENT, W/ 2- X 2' X 1/8' WASHER 4 NUT. (1) WITHIN 8' OF TOP, (1) WITHIN 8' OF THE BTM, (3)EVENLY SPACED. ❑O NOTES: ALL ANCHORS SHALL BE IN ACCORDANCE TO MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR I)BUCK ATTACHMENT D3 eCALE: 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS_ NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3/4" OR +5/4" (� Qll TO BLOCK +3/4" OR +5/4" 2X4: CM SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE _I45 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6: SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 IS' O.G. MAX SPACING. 2X8: SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 IS' O.G. MAX SPACING, 8' CMU 1/2' DRYWALL P P.T.. NAILER I --I /- DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +1 1/2" ( LI QI'P TO BLOCK +1 i/2" 2X4: cm SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6: CECI SECURE TO BLOCK W/(2) 3/16' TAPCON5 (MIN. SPANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4-) WITHIN 8' OF EACH END 4 IS' O.C. MAX SPACING. 2X8: Emm SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. — 8' CMU 1/2, DRYWALL I'X4' P.T. NAILER Q l- 1/16' O.S.B. X 4' MIN. DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +1 15/16" CWNDO'W TO BLOCK +1 15 16" 2X4: cm SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE _I45 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/40) WITHIN 8' OF EACH END 4 IS' O.C. MAX SPACING. 2X(b: SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X5: SECURE TO BLOCK W/(2) 3/16' TAPCON5 (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN S' OF EACH END 4 IS' O.C. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3/16' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK. 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS_ NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +2 1/4" @A OW TO BLOCK +2 1/4" 2X4: C&I SECURE TO BLOCK W/3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 IS' O.C. MAX SPACING. 2X6: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE _145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X8: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH To 2X PER MANUFACTURES DETAILS_ NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB �TO BLOCK +3" T `1, 1 ItlN lel 9 Yi 1 � Sl tl 19\ 1� +�'9 2X4: CM SECURE TO BLOCK W/ 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X6: CM SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X8: t� SECURE TO BLOCK WK2) I/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 8' CMU 1/2' DRYWALL 1'X4' P.T. NAILER -I/f6' OSB. X 4' MIN. l- DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3 7/16" �NDOVP TO BLOCK +3 7/16" 2X4: ® 2X4: CM SECURE TO BLOCK W/ SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 HEAD SIZE MIN. EMBEDMENT 1 1/4') .300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH WITHIN 8' OF EACH END 4 18' O_C, MAX END 4 IS' O.C. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE SPACING. NOTE: STRUCTURAL 2X MUST BE 2X6: CEM ON OUTSIDE 4 SECURED 2X6: cim ON OUTSIDE < SECURED SECURE TO BLOCK THROUGH NON-STRUCTURAL 3/16° TAPGON MIN. I-1/4' SECURE 70 BLOCK THROUGH NON-STRUCTURAL TAPCONS (MIN. SHA (MIN. SHANK SIZE EMBEDMENT INTO BLOCK W/(2) 1/4' TAPCONS (MIN. 3/16' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK. .145 MIN. HEAD SIZE 300 SHANK SIZE .145 MIN. MIN. EMBEDMENT 1 1/49 HEAD SIZE 300 MIN. 8' OF EACH END S° CMU EMBEDMENT I 1/49WITHIN 8' CMU 4 18' O.G. MAX SPACING_ 1/2' DRYWALL WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING, 1/2' DRYWALL 2X8: ® SECURE TO BLOCK I'X4' P.T. NAILER 2X8: CJ ❑ I'X4' SECURE TO BLOCK P.T. NAILER W/(2) 3/16' TAPCONS (MIN. SHANK SIZE DOOR CASING W/(2) 1/4' TAPCONS I' P.T. X 4' MIN. .145 MIN. HEAD SIZE (MIN. SHANK SIZE .145 .300 MIN, EMBEDMENT 1 1141) 2ND 2X SECURE TO STRUCTURAL MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 DOOR CASING WITHIN S' OF EACH END MEMBER W/(2A2d WITHIN 8' WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. OF EACH END 4 6' TO 8' O.G. MAX 4 IS, O.C. MAX SPACING, DOOR JAMB OR WINDOW DOOR JAMB OR WINDOW ATTACH TO 2X PER ATTACH TO 2X PER NOTE: SHIM AS NEEDED TO PLUMB MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO MANUFACTURES DETAILS. PLUt'1B JAMB (DO NOT EXCEED 1/4') JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3" DOOR JAMB TO BLOCK +3 3/4" F (ll FlIN1 DOW TO BLOCK +3 3/4'° Re"1 wed %r Uni�a°�AOfarn�,ade Scle^ems -."'9. I = I. PER CODE AND MANUFACTURER'S REQUIEREMENT 2X BUCKING FOR THE FRONT IN SWING DOOR5t INSIDE FACE IF 2X BUCKING SHALL BE INSTALLED FLUSH WITH INSIDE FACE OF DRYWALL. REFER TO MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION AND BUCK REQUIREMENTS, BUCK DETAILS SHOWN HERE ARE OPTIONS TO ACHIEVE MANUFACTURER'S R.O. REQUIREMENTS. FASTENING OF WINDOWS AND DOORS WHERE 1X BUCK IS INSTALLED REQUIRES THE FRAME TO BE FASTENED DIRECTLY INTO MASONRY. M crlu i' DRYWALL IX FURRING `-RIP 2XIO TO DOOR 8-1/81W FRAMING HOLD FLUSH TO INTERIOR FACE OF DRYWALL ENTRY DOOR BUCK VIREMi�'NTS — 2194 H"fY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 SURDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJE'C;T# 04321.201 101R1 MODEL: 4EHB 2605-- HAYDEN" GARAGE SWING: LEFT PAGE: ®� DETAILS 16-0 MPH EXP. C ARCHITECT. STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NIO 17305 DAET 10/28/21 SCAM: 1/4"=1'-0" 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W vii V W h V co N Q F A F ti SVHDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. I ARCHITECT- STATE OF FLORIDA NOV 1 6 2021 ma-ML1d. AbERSON AR NO 17305 PRINT 10 28 21 DATE: / / SCALE: 1/4"=V-0" SHEET WAI DRAINAGE PLANE (WRB LAYER *I, STUCCO WRAP) WRB LAVER #2 (FORTIFIBER BUILDING PAPER) METAL LATH STUCCO WOOD OR -1/16" ZIP WALL SHEATHING X—X—X—X 0 SELF-ADHESIVE FLASHING — — — — NOTE: METAL LATH: LATH TO BE PER SECTION R-103.1.1 / ASTM C-841-14a, MIN. 2.5 LBS. PER ,5a, YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) FINISH 6" SELF ADHESIVE OVER TOP 4 SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT TOP 4 SIDES BUILDING PAPER OVER 'QUICK FLASH' PIPE THROUGH— HROUGH / WALL 1\ 6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDING PAPER UNDER 'QUICK FLASH' NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES EVENT PENETRATION SCALE: N.T.S. ELEC. METEF VERIFY LO STUCCO SCRATCH COAT 4 1 COAT OF PAINT U1/5ACK- ROLL PRIOR TO ELEC. METER INSTALLATION O \_ ELEC. METER FIELD VERIFY LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM At CTI 7R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES :;0 SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COM50 OR METER CAN AND DISCONNECT ELECTRICAL CONDUIT PENETRATION lAro' ZIP SHEATHING SYSTEM (INSTALLED PER MANUR SPECS.) OR WOOD SHEATHING -WRB LAYER "I, STUCCO WRAP -WRB LAYER 02, FORTIF15ER BUILDING PAPER METAL LATH WOOD +. 7/a' TEXTURED CONSTRUCTION = :FINISH A WOOD a' CMU FASTEN TO WOOD STRUCTURAL MEMBER ®'I' O.C. MAX Ye' TO 12' MID -WALL WEEP SCREED 6' WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY BEFORE APPLYING FINISH + MASONRY 7B HORIZONTAL WEEP SCREED (FRAME TO BLOCK NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WR5 LAYER #1, CUT OPENING IN STUCCO WRAP APPROVED HOUSEWRAP FOR BOX INSTALLATION f\ CUT 'X' INTO STUCCO WRAP J MEMBRANE FLASHING WRB LAYER MI, APPLY SELF -ADHERING WOOD SHEATHING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER 01 APPROVED HOUSEWRAP BELOW CUT SUCH THAT NO MEMBRANE ENTERS BOX, APPLY TO FACE EDGE APPLY E-Z BEAD OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS &TP 1 APPLY 60 MIN GRADE 'O' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP &TP #3 .T E P ;*2m Rooewgd for code Unlvarsal Engineering Sciences WRB LAYER *1, STUCCO WRAP SELF -ADHERING MEMBRANE FLASHING WRE3 LAYER 4r2, FORTIFIBER BUILDING PAPER ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH 5T P #5 5T E P I*ro ELECTRICAL RECEPTACLE 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH; 321-802-3591 www.abdesigngroup.com AA #: 0003325 w U W 0 0. v to A F A x SvsDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321,201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHrrECT: STATE OF FLORIDA - NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 10 28 21 I)ATE: / / SCALE: 1/4"=1'-0" SKEET WA2 DRAINAGE F'LANE (WRP LA,rER 1*11 STUCCO WRAP) 11WR5 LA1r'ER. *12 (1=0RTIF15ER — — — — — 5UILDING PAFER) METAL LATH X X X X STUCCO WOOD OR i/1ro" ZIP WALL SHEATHING SELF-ADHESIVE FLASHINC- lk 2 1/2" k a CORNER SEAD (1=A6TENER 8 SFACING a i" O-C.) CMu 1/2" TNICK, 2 COAT CEMENT FLA6TER AFFL[ED DIRECTLY' TO MASONR°I' GgReviewed for code Universal E�nce Sc end neerinp 2194 HWY A1A, SUITE 301 INDIAN HARBOUR' BEACH, FLORIDA 32937 PH: 321-802 3591 www.abdesigngroup.com AA #: 0003325 F W U W 0 F 0. Cat w q F Q F a F DIV. & LOT: REEKSMEPHASE 2 LOT #101 ECT# 21.201 101R1 EL:4EHF3 5- HAYDEN" GARAGE Si1]14G LEFT PAGE: WAL ASSEM DETAI 160 MPH E ARCHrrECT: STATE OF FLORIDA NOV a F. 2021 MMAEL C. ANDERSON AR NO 173,05 DATIE: 10/28/21 41CALE: 1/4"=V-0" SHEET v "m 2x6 SUB -SAND W/l "x4" NOTCH -s END, WRAPPED IN PEEL 4 STICK DRIP EDGE I/S" TEXTURED FINISH e WOOD 1/2' TEXTURED FINISH e CMU I� I� I� I� I � I � METAL FASCIA \� WRAP Ys" FROM STUCCO, 1" FROM WOOD WALL \� EXTERIOR WALL (FRAME OR CMU) \� NOTE: NOTCH FOR 2X�o N, SUB BAND ONLY \ / ( )ELEVATION- METAL FASCIA WRAP 2X6 SUM BAND —ROOF KICK OUT REMOVED FOR CLARITY -ROOF DECK (BEYOND) DRIP EDGE, 1" OFF WALL IVNOT INTO STUCCO) 11/8" TEXTURED FINISH a / WOOD, 1/2" TEXTURED i i FINISH 6 CMU 1,,, 2x(o SUB -BAND W/1"x4" NOTCH a END, WRAPPED IN PEEL 4 STICK METAL FASCIA WRAP I' OFF WOOD WALL. SUB BAND 2" ° OFF WOOD WALL 1/8' TEXTURED FINISH im WOOD, 1/2' TEXTURED FIN15H 0 CMU METAL LATH WOOD SHEATHING OR CMU WRB LAYER 01, STUCCO WRAP (FRAME ONLY) WRS LAYER 02, FORTIF15ER BUILDING PAPER (FRAME ONLY) ROOFING CEMENT DRIP EDGE METAL KICK OUT x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x -.- x x x x x x x x x x x x x x X X x x X x x X x x X x x x x X X x x X x x X x x X x x x x ' x x x x x x x x x x x x x ,. �' .' NOTE - IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES PRE-ENG'D TRUSS TO BE CUT a WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4 "x4' - m' SCABBED TO TRUSS W/126 NAILS 6"-S' O.G. MAX. 2x SUB -SAND W/lY"x4" NOTCH -a END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL ® WALL SVB BAND DETAIL @ WALL W/KICK- OUT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/l2"x4" NOTCH 6 END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY p RCNVW^d for Code comgionm um "I nm FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4." ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/ly"x4" NOTCH a END, WRAPPED IN PEEL 8 STICK *ROOF CEMENT 6 ROOF EDGE OMITTED FOR CLARITY 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F w IN U w 0 a a w a F A h SUHDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 UODET : 4EHB 112605- HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB -BAND 160 MPH EXP. C ARCHrrECT STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 ""+" 1 DATE: 10 28 21 SCALE: 1/4"=1'-0" a c Lr 11Q'_R" 27'-10" 10'-0.1 1'-10" 4" T-4" '-4" FM-12X18 `r . F — -1. 10 ro ro N I 4" CONC. w lui- I N q SLAB a w o OD 00 LL I J (L I LL U' OD OD CD to 3 I = M' �--4 -----1— —FM-16x18 —--—� 164" 11'-8" 10'-0" cla lcq oq oa w l C)xX N to n I OF coY0TO�P LL b SLABCD J N I wU N O N w V 11'-10" T-5" v 20'-5"LL @ s 1'1 CW-12x12 — — x 1 11 — 8 i 1.1 1.1 o F-2 x24 ii n A SI , o M CWC-12x12— n o LL Z co `e) _ _ wil O O ��� o V'v �4" iV = 11 LL O (I U2N iOD .N' VC UP TO2NDFLOOR I Uil@J 11 N 3'-6" CHASE (FIELD VERIFY I a ii L C)EXACT LOCATION) 8 r n Lu w ' 5 1.1 I ii w io O 3'0. d �~ in 9' 4, 2, 8, 9' 0„ 9.3, 915„X cl)O I N X 1 014" tV N 1.1 TOP OF SLABCL w e D m IU #3 TRANSFER STEEL @ 24" O.C. MAX 2 bD I ,., N I N c 0 OL U-" FIN. ELEV. co I FIN. CONC. SLAB col io Ig I I 11 x m LL u_ 1 4 4 FMC- 16x18 _ — ——FM=16x18 _ Ell i IE 1.1 2' 10" 16'-0" 1.1 2'-1 1'_03'-5"� - T-11" 9'-8" I M H � L� — — FM-1 — — — — — — _f 3 1/2" 0 v 4" CONC. w " cx v o E SLAB o- Lu O EL I io El FM-12x18op cr C?—_ N 20'-4" '-4" 5'-4" '-4" 10'-01. '4' 21'-8" 18'-0" 39'-8" FOUNDATION PLAN SCALE: 1/4" = V-0" FOUNDATION NOTES 1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR COMPACTING REQUIREMENTS. 2. TOP OF FINISHED SLAB SHALL BE+-0'-0". 3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 4, REFERENCE ELEVATION +-0'-0", SEE SURVEY PLOT FOR NAVD. 5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: PROVIDE 1/2" FELT PAPER AT THE JOINT. 7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL DRAWINGS. 8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. 9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS AND WITH THE MANUFACTURES SPECIFICATIONS. 10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. 11.81NDICATES #5 BAR, 13INDICATES #6 BAR,ONDICATES #7 BAR VERTICAL REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900 HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. 12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = 30", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. 13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED OTHERWISE. 14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS 15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 402/602-16, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION SHALL BE IN ACCORDANCE WITH TMS 402/602-16, USING: F'm = 2,000 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. 16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 3 OF SLAB SUPPORTED 3'-0" O/C MAX. SEE PLAN FOR WWM SIZE. INSPECTOR NOTE: 1. STRUCTURE WAS DESIGNED BASED ON THE 2020 FLORIDA RESIDENTIAL BUILDING CODE, RESIDENTIAL, 7th EDITION EDRevwmed for Code Sciences SLAB SCHEDULE SLAB THICKNESS REINF. REMARKS 6x6 W1.4xW1.4 OVER GENERAL 3 1/2" 6 MIL VAPOR COMPACTED FILL BARRIER FOOTING RSCHEDULE OUDOOEG EACH WAY. PROVIDE CORNER BARS SAME SIZE QUANTITYBARS MARK WIDTH LENGTH THICKNESS BOTTOM REINF. TOP REINF. T.O.F. SHORT LONG FM-12x18 12" CONTINUOUS 18" - (2) #5's _ (+)0'-0" FM-16x18 16" CONTINUOUS 18" - (2) #5's _ (+)o"_o" FM-20xl8 20" CONTINUOUS 18" - (2) #5's - (+)0"-0" FMC-1608 16" CONTINUOUS 18" - (2) #5's - VARIES CW-12x12 12" SEE PLAN 12" - (2) #5's - (+)op'_o" CWC-12x12 12" SEE PLAN 12" - (2) #5's - VARIES F-24x24 24" 24" 12" (2) #5's (2) #5's _ (+)0"-0" TE-1 8" SEE PLAN 8" (1) #5's 0„-4„ NOTE: WELDED WIRE MESH & VERTICAL REBAR NOT SHOWN FOR CLARITY SECURE A/C SIMPSON UJB #3 TRANSFER STEEL @ 24" O.C. MAX ON 1 1/2" STRAP TO UNIT ROLL STRAP CHAIRS @ FOUNDATION SLAB & WIRE TIED CONC. W/ TO CONTINUOUS FOOTER STEEL (2)-3/1(o'X2' OR EQUAL a q. TAP -CONS EACH COMER OF UNIT CONC. SECURE STRAP TO ° ° TOP OF SLAB SLAB UNITS UJ/ (2) "Sxl 1/4 SHT MTL SCREWS L-A SUPPORT#3W/11/2"CHAIRSA/C CONNECTION . TO PAD DETAIL- ) TRANSFER STEEL INSTALLATION SCALE: 3/4"=T-0" 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti W U W 0 F a v W A F Q svaDly eo LOT: CREEKSIDE PHASE 2 LOT #101 PROJECTS: 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: FOUNDATION PLAN 160 MPH EXP. C ARCHITECT. STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 EXT. PORCHCH SLAB W/ 1/2" ISOLATION / JOINT (WHERE I APPLICABLE) z (V I' a STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU WALL SEE SLAB SCHEDULE -4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" EXTERIOR MONO -FOOTING BOLLARD LAP TOP PLATE A MIN. OF 48" AND NAIL W/ 16d COMMON NAILS, 2-ROWS, 4" O/C BTM. LAP TO OCCUR OVER STUD 2x4 OR 2x6 WOOD BEARING - WALL W/ SYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE BTM. PLATE TO BE PT. PROVIDE DBL. TOP PLATE TOP OF SLAB SCALE: 3/4"=1'-0" 0 M - i O EXT. PORCHSLAB? W/ 1/2" ISOLATION / JOINT (WHERE APPLICABLE) z w K STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU WALL +- 0,-0, TOP OF SLAB L-SEE SLAB SCHEDULE TOP -4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY EXTERIOR MON @ GARAGE OOTING SCALE: 3/4"=1'-0" w w NEW REINF. BAR m SECURED W/ 2- PART 2" CAPPED a 3 I EPDXY. MIN. EMBED 8", LINO GALVANIZED PIPE J d W/FLANGE @ BASE i FOLLOW ALL MANF. y a SPECIFICATIONS FOR ZED I USE AND z PREPARATION OF 4„ HOLE. SECURE FLANGE TO SLAB W/(4) 1/4" X 2 1/4" p TAPCONS `°' coC'QzO P + SCALE: 3/4"=1'-0" VERIFY HEIGHT OF WALL W/ PLAN 7:iiPI F00 U. 11E*10114Rcc SECURE BT. PLATE TO SLAB W/10d MASONRY NAIL 12" O/C STAGGERED. ADDITIONAL METAL CONNECTORS NOT REQUIRED WHEN NO UPLIFT IS PRESENT. -SEE SLAB SCHEDULE � a M M I d a a d a. SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY INTERIOR FOUNDATION WOOD WALL SCALE:3/4"=1'-0" (NO UPLIFT) 4" CHAMFER (I -STORY) 6" CHAMFER (2-STORY) ADDING BAR TO MONOLITHIC FOUNDATION SCALE: 3/4"=1'-U" POURED LINTEL CONT. (TYP.) �0,, 8" CMU FILLED CELL (TYP.) .u+ 2X WALL FRAMING •• 1/2" DIA. SIMPSON STB2 BOLTS 5" MINIMUM EMBEDMENT INTO GROUTED CELL, 4" FROM ENDS AND 16" O.C. VERTICALLY MAX INTERIOR FRAME BRG WALL TO BLOCK WALL CONNECTION SCALE: 3/4"=1'-0" EXT. PORCH SLAB W/ 1/2" ISOLATION JOINT (WHERE APPLICABLE) 6" PVC CHASE — THRU FOOTING 30" MIN. EACH WAY MONOLITHIC FOOTING ° ° • ��. .. p P OO v. ° D�� v r P . :FM v . 1 CORNER BARS, SAME SIZE AS LARGER BAR l I IN FOUNDATION WITH 30" LEG EACH P ° WAY AT ALL CHANGES IN DIRECTIONS ' p SO THAT THE STEEL REINF. IS CONTINUOUS MATCH AMOUNT OF CONTINUOUS BARS CONTINUOUS STEEL MONOLITHIC %. FOOTING REINFORCEMENT SEE SCHEDULE N WHEN TRANSITIONS ARE MADE FROM FOUNDATIONS HAVING DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEAST NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), LINO MONOLITHIC FOUNDATION CORNER BARS DETAIL SCALE: 3/4"=1'-0" STEEL REINFORCING IN GROUTED z ' CELL SEE PLAN FOR SIZE AND � SPACING REQUIREMENTS w mw U � J o� - z 8" CMU WALL n g a. a v e SEE SLAB SCHEDULE 4" CHAMFER (1STORY) o. 6" CHAMFER (2-STORY) • z ° MATCH STEEL g REINFORCEMENT PER SCHEDULE SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY OF; BAR SIZE 48 BAR DIA. #3 18' #4 24" #5 30" #6 36" #7 42" CURB FOR MASONRY UNITS SET AT ELEV: 0'-01, RECESS AROUND GARAGE DOOR OPENING LAP TOP PLATE A MIN. OF 48" AND NAIL W/ 16d COMMON NAILS, 2-ROWS, 4" O/C BTM. LAP TO OCCUR OVER STUD 2x4 OR 2x6 WOOD BEARING - WALL W/ SYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE BTM. PLATE TO BE PT. PROVIDE DBL. TOP PLATE PVC CHASE THRU FOOTING 12 SCALE: 3/4"=1'-0" rn w E SCALE: 3/4"=1'-0" VERIFY HEIGHT OF WALL W/ PLAN PROVIDE BLOCKING SECURE BT. PLATE TO SLAB W/10d MASONRY NAIL 12" O/C STAGGERED ADDITIONAL METAL CONNECTORS NOT REQUIRED WHEN NO UPLIFT IS PRESENT. -SEE SLAB SCHEDULE Reviewed for Code Compliance Universal Engineering Sciences SEE SCHEDULE �— FOR WxD, BAR SIZE AND BAR QUANTITY INTERIOR CURB FOUNDATION WOOD WALL SCALE: 3/4"=T-0" (NO UPLIFT) IYI/11 VI I V ILLL REINFORCEMENT PER SCHEDULE NG 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W W U W 0 F ri Ci W W A F A ti SUBDIV & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA MICI L1 d. Z ERSON AR NO 17305 PRINT 10 28 21 DATE- // SCLE: 1/4"=1'-0" SHEET S I . 1 A 9 a FIRST FLOOR DOWEL PLAN SCALE: 114" = 1'-0" NEI" a (V N Reviewed for Code Compliance Universal Engineering scenom 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.a bd esigngrou p„com AA #: 0003325 h W U W ri 0 F ri) Ud W A h A h SU33DIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODELc 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR DOWEL PL14N L160 MPH EXP. C ARCHITECT, STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 DATE:: 10 21 DATE: /28 /' SCALE: 1/4"=1'-0" SHEET S1.2 d .e e °d e TIE VERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK GROUTED BOND BEAM d. e d.c HORIZONTAL/VERTICAL REINFORCING SCALE: 3/4"=1'-0" VARIES PER ELEV. CLEAN OUT REQUIRED FOR INSPECTION 0'-0" FIN. FLR. TIE VERTICAL REBAR TO HORIZONTAL REBAR W/10" HOOK BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" NEW REINF. BAR SECURED W/2-PART EPDXY. MIN. EMBED 6", UNO FOLLOW ALL MANF. SPECIFICATIONS FOR USE AND PREPARATION OF HOLE. u CoQQ�°: n n �d A. d .Q ° d ° ed e' d STEEL REINF. OF BOND. BEAM ADDING BAR TO 4 BOND BEAM SCALE: 3/4"=1'-0" Z4 z N OFFSET METHOD EXT. PORCH SLAB W/ 1/2" ISOLATION JOINT (WHERE APPLICABLE) 6" PVC CHASE — THRU FOOTING HORIZONTAL/VERTICAL REINFORCING SCALE: 3/4"=1'-0" CONTINUOUS METHOD STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU WALL SEE SLAB SCHEDULE e 4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) ° MATCH STEEL REINFORCEMENT PER SCHEDULE SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" TOP OF SLAB BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" PVC CHASE THRU FOOTING 5 #5 BARS REINFORCEMENT PER SCHEDULE CMU UNIT DIMENSIONS ARE NOMINAL SIZES MASONRY SYMBOLS 01[el SiUALL: J/4"=T-U Reviewed tot Code r ,ompliance Universal ring 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.a bdesigngrou p.com AA #: 0003325 Fes. W w w O F U W A Q 'r SUHDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL• 4EHB "2605—HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. lc ARCHITECT- STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON L AR NO 17305 J PRINT 10 28 21 DATE: SCALE: 1/4"=1'-0" SHEET S1. 2 A FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. HEADER SCHEDULE MARK SIZE & DESCRIPTION REMARK 1O (2) 2X8 BEAM SCHEDULE ENZOM INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL/T.O.A. = TOP OF ARCH / T.O.S = TOP OF SLAB ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION fc (psi) SIZE' ZE REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING BB1 MASONRY 3000 8x16 — (1) #5 (1) #5 N/A — GROUTED SOLID BB2 MASONRY 3000 8x8 — (1) #5 — N/A — GROUTED SOLID SEE SHEET S2.2A FOR SAFE LOAD TABLES I IIUMIVD 8F16/1T/1M/OB ■ 8F16/1T/OM/OB 8F16/1T/OM/OB ♦ ■ ��m�omm��mm��mm��m�����mme FIRST FLOOR LIFT BEAM PLAN SCALE: 1/4" = 1'-0" figReweuW for Cade unloonao I � isnce 04Ineenng scio z =:ae; ic4y.:.�ripS 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W 12 U W 0 F a U W W A F A SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR LIFT BEAM PLAN AND NOTES 160 MPH EXP. C ARCHITECT STATE OF FLORIDA NOV 1 6 2621 MICHAEL C. ANDERSON AR NO 17305 PRINT 10 28 21 DATE: / / SCALE: 1/4"=1'— 0" SHEET S 2 #5 CORNER BAR W/ 30" LAP FOR EACH COURSE OF BOND BEAM VERTICAL REBAR W/ 10" HOOK 30" TYPICAL #5 BAR IN BOND BEAM OPEN FACE SHELL SO AS TO ALLOW BENT BAR TO BE PLACED IN UPPER AND LOWER BOND BEAM CORNER REINFORCING OF BOND BEAM SCALE: 3/4"=V-0" SINGLE BOND BEAM AT HIGHER ELEVATION SINGLE BOND BEAM AT LOWER ELEVATION 70, 0 #5 MIN. REQUIRED IN EACH CELL HOOKED IN TOP BOND BEAM W/ STANDARD ACI HOOK #5 BAR BENT AS SHOWN CORNER BARS 3 AT CORNER STEP SCALE: 3/4"=1'-0" NOTES TO THE INSPECTOR/CONTRACTOR 1. PLACE LINTEL ACROSS TOP OF OPENING. 2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL. 3. PLACE MASONRY UNITS AS REQUIRED TO ACHIEVE THE REQUIRED BEARING PLACE STEEL HEIGHT. OF REINFORCING (L2) 4. THE LAST COURSE WILL BE A BOND BEAM WITH (1) #5 BAR CONTINUOUS AROUND AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT THEN THE LAST y / TWO COURSES ARE BOND BEAMS WITH A #5 BAR IN EACH COURSE. /5. SHOULD THE DOUBLE BOND BEAM COINCIDE WITH A LINTEL THE BOTTOM / COURSE OF BOND BEAM IS OMITTED AND A LINTEL IS PLACED. THE STEEL REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUOUS THROUGH THE / TOP OF THE LINTEL. 6. UNO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN 16" DEEP. / PgS�F�P 8x16 DBL. BOND — 2 P� BEAM W/ (1) #5 BAR �\p�� EACH COURSE 8x8 BOND BEAM - TOP OF W/ (1) #5 BAR \ :y P4 BOND BEAM T FOR F = FILLED W/GROUT I �\pt�O U = UNFILLED NOMINAL # OF #5'S, IN 2ND BOND WIDTH BEAM COURSE 16-1 T/1 M/OB Q�EF NOMINAL—�� e" HEIGHT # OF #5'S, TOP IT IS THIS ENGINEER'S INTENT BOND BEAM COURSE THAT XFXX - 1T/1 M/OB INDICATES A DOUBLE BOND BEAM 14'r, #5'S, BOTTOM AND XFXX - 1T/OM/OB INDICATES A SINGLE BOND BEAM PLACED IN LINTEL IT IS THIS ENGINEER'S INTENT AND XUXX - 1T/1 M/OB INDICATES A DOUBLE BOND BEAM ABOVE UNFILLED LINTEL AND XUXX - 1T/OM/OB INDICATES A SINGLE BOND BEAM ABOVE UNFILLED LINTEL WINDC PRE -CAST WINDOW SILL TYPICAL MASONRY WINDOW SILL CONSTRUCTION SINGLE #5 CORNER BAR, 30x30 TURNED UP OR TURNED DOWN INTO STEEL REINF. OF FILLED CELL BOND. BEAM PROVIDE #5 BAR AT EACH SIDE STEEL REINF. OF OF ELEVATION BOND.BEAM CHANGE CHANGE IN ('�,_�ELEVATION OF BOND BEAM GROUT SOLID FROM — LINTEL TO TOP OF BOND BEAM, IF FILLED LINTEL. 8x8 PRE -CAST CONCRETE — LINTEL W/ (1) #5 BAR (L2) LENGTH OF BAR � WIDTH OF OPENING -2" OR 8x8 PRE -CAST CONCRETE LINTEL, W/O STEEL (L1) REFER TO PLAN FOR LOCATIONS OF OPENING dp Sa TYP. 8"x16" BOND BEAM OF OPENING SEE NOTE 5 = - MASONRY BEAM DESIGNATION WOOD SECTION FASIENERSPACING de =2" MIN, 2 4" MAX So = 2 t" MIN, 9" MAX (2) s, =12'' MIN, 2 }" MAX ed = t" MIN, 2 2' MAX de =2" MIN, 2 y" MAX 5o = 2 y" MIN, 9" MAX (2' s, =1 2" MIN, 2 2" MAX* ed = 4" MIN, 2 2" MAX de =2" MIN, 2 y" MAX so = 2 y" MIN, 9" MAX (2)2d s, =1 2" MIN, 2 2" MAX* ed = J" MIN, 2 2" MAX *MUST HAVE 2 OR MORE LONGITUDINAL ROWS OF NAILS Reviewed for Code Compliance Universal Engi us s NOTE: • ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES OF THE COLUMN • ALL NAILS PENETRATE ALL LAMINATIONS AND AT LEAST 1 4" OF THE THICKNESS OF THE OUTERMOST LAMINATION WHERE: de = END DISTANCE so = SPACING BETWEEN ADJACENT FASTENERS IN A ROW s, = SPACING BETWEEN ROWS OF FASTENERS ed = EDGE DISTANCE DOUBLE STUD W/ 10d NAIL ATTACHMENT SCALE: N.T.S. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 Cam. W V W O F a V 4 F A SUHDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4E I "2605— HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 160 MPH EXP. I ARCHITECT STATE OF FLORIDA NOV 16 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 10 28 21 [DATE; SC ALE: 1 /4"=1' — 0" SHEET S 2•1A "L TT'S C CRETE" / "CAST-C ET " / "QUALITY" SAFE LOAD TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT SAFE PLF LOAD SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH 8U8 8/8-OB /16-1T/OB /20-1T/OB /24-1T/OB 8-1T/OB 32-9T/OB �(PE LENGTH 8/8 PLAIN 8/8 SOLID -- __ TYPE LENGTH �_ �-- 8/8-1T 8/16-1T 8/201T 8/24-1T 8/28-1T 8/32-9T 8/8-18 /16-1T/1B 0-1T/16 4-1T/1B /28-1T/1B 2-1T/1B 8/8-2T 8/162T 8/202T 8/242T 8/28-2T 8/32-2T 3'-6" PRECAST 1436 952 3114 4217 5321 6426 7531 " 3'6 PRECAST 689 1024 3'-6i" PRECAST 1569 3524 4394 5263 6132 7001 2465 6113 6385 7708 9031 10000 1569 3524 4394 5263 6132 7001 4'-0" PRECAST 1065 700 2305 3125 3945 4765 5587 4'-0" PRECAST 514 763 4°-0" PRECAST 1363 3060 3815 4570 5325 6079 1961 6113 7192 6524 7627 8751 1363 3060 U15 4570 5325 W79 4'-6" PRECAST $19 533 1770 2400 3033 3666 4300 4°-6" PRECAST 398 591 4'-6" PRECAST 1207 2582 3375 4043 4711 5379 1625 5743 7547 6752 6541 7565 1207 2707 3375 4043 47'11 5379 514" PRECAST 931 1247 1999 2560 3123 3686 4249 5° -4" PRECAST 411 411 " -4 ' 5PRECAST 1016 1806 2374 2944 3513 4084 1319 4460 7196 7342 5780 6259 1016 2276 2838 3399 3961 4084 5'-10" PRECAST 817 1024 1631 2090 2549 3009 3470 T-10" PRECAST 340 339 5'-10" PRECAST 909 1499 1971 2443 2915 3387 1161 3693 5877 6036 6648 5776 929 2080 2593 3107 3620 4133 61-6" PRECAST 692 1139 3227 3031 3707 4383 5061 61-6" PRECAST 410 721 V-6" PRECAST 835 1201 1578 1965 1 2332 2709 1139 3227 4598 7054 10000 8825 835 1868 2329 2790 3251 3712 T$" PRECAST 570 938 2498 2206 2698 3191 3685 7 -6" PRECAST 303 534 7 -6" PRECAST 716 900 1181 1462 1743 2025 938 2498 3408 4864 70 67 64,72 727 1624 2025 2426 2827 3228 9'-4" PRECAST 428 633 1593 2204 2481 2818 2621 9140 PRECAST 192 384 9'-4" PRECAST 454 586 767 948 1129 1310 639 1674 2298 3081 4099 4899 572 1318 1643 1969 2164 2519 101-6" PRECAST 388 487 1247 1767 1904 2163 2028 10,-6" PRECAST 151 301 10'-6" PRECAST 356 468 612 755 899 1042 550 1407 1897 2781 3222 3784 504 1180 1472 1763 1710 1989 11,40 PRECAST 330 5" 1312 1742 2252 2868 3630 1114" PRECAST 132 417 11'-4" PRECAST 430 406 530 653 777 872 644 1312 1742 2252 2868 3662 466 1042 1372 1643 1470 1710 12'-0" PRECAST 308 507 1210 1596 2048 2586 3191 12'-0" PRECAST 111 370 _ 12°-0" PRECAST 383 383 366 366 476 587 698 783 507 1210 1596 2048 2586 3171 1300 1560 1394 1476 13'-4" PRECAST 270 433 1045 1365 1732 2157 2535 � " 13 -4 PRECAST 82 298 131 411 PRECAST 308 303 303 393 484 575 645 414 1045 1365 1732 2316 2605 398 1057 1312 1071 1203 14'-0" PRECAST 254 388 978 1272 1606 1988 2279 ° " 14 -0 PRECAST 71 293 14'-l�11 PRECAST 279 278 360 443 526 609 390 978 1272 1606 1950 2389 378 717 961 1192 975 1133 14'-8" PRESTRESSED N.R. NR NR NR NR NR NR 14'-8" PRESTRESSED N.R. 283 14-8 '" PRESTRESSED 239 422 506 626 746 865 458 1079 1429 1824 2277 2712 246 663 980 1237 1474 1715 15'-4" PRESTRESSED N.R. NR NR NR NR NR NR 15-4" PRESTRESSED N.R. 252 15'-��" PRESTRESSED 224 387 464 574 684 793 412 1014 1340 1703 2118 2513 230 616 908 1134 1353 1572 17'-4" PRESTRESSED N.R. NR NR NR NR NR NR 17'-4" PRESTRESSED N.R. 183 17'-4°' PRESTRESSED 187 326 365 1 451 587 680 300 856 1121 1413 1739 2047 192 506 720 501 1135 1312 19'-4" PRESTRESSED N.R. NR NR NR NR NR NR 19'-4" PRESTRESSED N.R. 148 191411 PRESTRESSED 162 266 348 430 513 595 235 736 959 1200 1467 1716 166 429 623 803 950 1098 21'-4" PRESTRESSED N.R. NR NR NR NR NR NR 21'4" PRESTRESSED N.R. 125 21'-4" PRESTRESSED 142 219 308 381 454 527 180 598 833 1038 1168 1468 142 373 537 690 816 943 22'-0" PRESTRESSED N.R. NR NR NR NR NR NR 22°-O" PRESTRESSED N.R. 116 _ 22'-0" PRESTRESSED 137 226 290 359 428 497 165 550 784 992 1203 1381 137 358 513 659 779_1 900 24°-0" PRESTRESSED N.R. NR NR NR NR NR NR 24'-0® PRESTRESSED N.R. 91 24'-0°' PRESTRESSED 124 174 245 302 360 418 129 450 654 824 1014 1147 124 319 455 581 687 1 793 - ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY (QUALITY 2018 EDITION, LOTT'S MAY 2015 EDITION - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE AND CASTCRETE MAY 2015 EDITION. - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE DIVISION ACCEPTANCE #: 19-0130.13 5 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH(, FLORIDA 32937 PH: 321-802-3591 www.a bdesigngroup.corri AA #: 0003325 v w O a A h q SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT## 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SJEXP. LEF PAGE: SAFE L TABL 160 MPH ARCHITECT. STATE OF FLORIDA NOV 1 & 2021 MICHAEL C. ANDERSON, L AR NO 17305 PRINT 10 28 21 DATE: / / SCALE: 1/4 =1'- 0" FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 WI 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. m TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2A BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. COLUMN SCHEDULE SIZE & BASE PLATE OR REMARK DESCRIPTION REINFORCEMENT LMARK 4X6 (3 %"x5 %z'") SYP. HTT4 W/5/8" DIA x 5° 5/S3.lA PT., WOOD POST EXP. BOLT r----------I FIRE DRAFT STOP L---------I 3/4" SUB FLOOR �_ 2X4 NAILER {� I FOR DRAFT PRE-ENG. JLL_ STOP FLR. TRUSS ELEV. VIEW ill PRE-ENG. FLR. JOISTS �t I 3/4" PLYWOOD 1� 1 DRAFT STOP �I PRE-ENG. FLR. JOISTS II 1 2X4 NAILER FOR DRAFT STOP 3/4" PLYWOOD DRAFT STOP PLAN VIEW DRAFT STOP DETAILS t-J -%J r `-1 -_�v� CALN_t CJ1L 1A L2G3.1 _Lu 9AJ1331� -- II It ItIt II II II II II II II II II II II II II it II I II it II II II II II it II II II II II II II II II II II �� I I 11 I I I I I I 11 II II tl II II II 11 11 II II II II II II it II �� II II II II ii II II II II II u u n u u u n n It n I I I II II2� J9 Ih 11 J2° II I II II II II J3 II II II II II 11 II II II p II II II II II It II 11 11 II II II II II it II II II II II II 21x4 WOOD WAL'LW/ II II II II II II it II II II 1 t n I I I I n 11 a SYP. NO.2 II STUDS II 2x4 WOW/ OD II / . o \ II II II II II II it II 12 O.C. II II IISYP NO.2 II II II II II II n itn II II I I n 11 ° D1 II n t STUDS @ 11 It L II II II II II I I 12" Q.C.11 2X6 WOOD BM1 II II WALL W/ DBL. iJ6 — — — -- — — — STUD UNDER II IIII 4 `° � J4 EACH JOIST t� _ F- I 11 II �� n 11 III .1 III III 4 DBLSTUD — II 2X4 WOOD PROVIDE DRAFTSTOPPING WALL W/ DBL. L i 11 II STUD UNDER tl It 4 ALONG THIS TRUSS AS TO II EACH JOIST II II .1 11 LIMIT AREA TO 1000 S.F. II II PER FBCR 302.12 II „ n II II II n � (I I �L J7 II II II (I J = = PRE -FABRICATED FLOORI JOISTS @ W O.C. II II II II II II II II I �1 I1 n n n n II n Co.. Il II II ii II it II u n n u n II n u n n II II II II II II II II \JMEG I II II II II II II it II II II G1 It 11 5 II II II II II I II It It II 11 y I _1l___11��_�_�= II 10, CJ3EI I II ii II II II �p -I - - It u u n u 11 I -------------- EJ6E FIRST FLOOR FRAMING PLAN 1/4" = 4 BM1 TO CMU WALL W/ SIMPSON LGUM46SDS W/ (4) 3//9 x C TrfEN HD ANCHORS AND (4) Y4' x 2)? SDS SCREWS TO BM7 rMTAR I CAE 0 Reviewed for code Unive g ngln* ing 91 nu»e 194 HWY A1A, SUITE 301 NDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.a bd esigngrou p.com AA #: 0003325 F W U W 0 F rJ W A F A ti sUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR FRAMING PLAN 160 MPH EXP. C ARCHrrECT: STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 P RINT 10/ 28/ 21 DATE: SCALE: 1/4"=1'-O" S"EET S3 ENGINEERED WOOD TRUSSE PLYWOOD SHEATHING, SEE @ 24" O/C, SUBMIT SHOP "ROOFANALL/FLOOR DRAWINGS FOR REVIEW SHEATHING AND APPROVAL FASTENER SCHEDULE" # 1100 UPLIFT SIMPSON (1) SIMPSON HETA16 TRUSS ANCHOR WITH 1„ PLYWOOD SHEATHING, SEE (1) SIMPSON HETA16 HTSM20 W/10 10d TO (9) 10d x 1 z NAILS TO TRUSS "ROOF/WALUFLOOR TRUSS ANCHOR WITH NOTE: A PT SYP #2 2" x 4", TRUSS AND H 1/4" x 2 1/4" 3-(2) SIMPSON HETA16 TRUSS ANCHOR WITH SHEATHING 1 TITEN 2 ANCHORS TO (12) 16d x 1 2" NAILS TO TRUSS FASTENER SCHEDULE" (9) 10d x 1 z NAILS TO 6", 8" x 4'-0" MAY BE ADDED CONT POURED LINTEL DBL STRAP, 1 EACH SIDE WRAPS UP AND GIRDER. PROVIDE 5" W/ 10d NAILS, 2 ROWS, 3" MINIMUM CONCRETE O/C TO FACILITATE ONE OVER TRUSS (NOT SHOWN) # 1900 UPLIFT (2) SIMPSON EMBEDMENT. USED IN ADDITIONAL PLY MAX. TO C-(1) SIMPSON LGT2 GIRDER TIEDOWN WITH NOTE: APT SYP #2 2" x 4", CONJUNCTION WITH ACCOMMODATE GIRDER OPPOSITE INSTALLED ON PRE-ENG TRUSS (16) 10d x 3 4" NAILS TO GIRDER AND 6", 8" x 4'-0" MAY BE ADDED OPPOSITE FACES OF (2) SIMPSON HETA16 TRUSS ANCHORS HEAVY UPLIFT TIEDOWN REQUIREMENTS. BLOCK WALL W/1010d TO W/ 10d NAILS, 2 ROWS, 3" CONNECTOR WITH (12) 16d x 3 2" NAILS TO GIRDER O/C TO FACILITATE ONE TRUSS AND (4) 1/4" x 2 1/4" ADDITIONAL PLY MAX. TO TITEN 2 ANCHORS TO CONTINUOUS BOND BEAM 1x2, 2x WOOD FASCIA ACCOMMODATE TRUSS A-(1) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN CONT POURED LINTEL SEE ARCHITECTURAL ANCHOR REQUIREMENTS. ; WITH(4)$' x 5" TITEN HD TO CMU AND (12) SDS 2x SECURED W/ (3) 16d 4 x 2 2 TO GIRDER GALV. COMMON NAILS. ENGINEERED WOOD B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH lx2 SECURED W/ 10d TRUSSES @ 24" O/C, 1x2, 2x WOOD FASCIA (2) z" x 5" TITEN HD TO CMU AND (18) SDS 4" x GALV. COMMON NAILS a SUBMIT SHOP DRAWINGS SEE ARCHITECTURAL 3" TO GIRDER 12" O/C FOR REVIEW 2x SECURED W/ (3) 16d C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH AND APPROVAL GALV. COMMON NAILS. (2) z" x 5"TITEN HD TO CMU AND (18) SDS 4" x 3" lx2 SECURED W/ 10d MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN) GALV. COMMON NAILS BEAM ENSURE THAT CELLS ARE GROUTED MASONRY BOND BEAM 12" O/C SEE SCHEDULE SOLID, 8" EACH WAY OF BOLTS SEE SCHEDULE TITEN 2 ANCHORS MIN. A ALLOWABLE UPLIFT = U:1810 LBS, L:770 LBS (1 PLY) A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) 2" COVER & 2" APART B ALLOWABLE UPLIFT = U:2365 LBS, L:1430 LBS (2 OR 3 PLY) B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) REPAIR OF MULTIPLE MISPLACED EMBEDDED TRUSS ANCHOR TYPICAL TRUSS/ TYPICAL ROOF 3 SCALE:3/4"=1'-0" 1 a 1 b 1 c GIRDER CONNECTOR(S) SCALE:3/4"=1'-O" 2a 2b 2c SCALE:3/4"=1'-0' GIRDER CONNECTOR(S) I i 3/4" T & G SUBFLOOR GLUED AND SCREWED AS PER SCHEDULE LSTA12 20 GAUGE W/ 10dxl/2 HDG COMMON NAILS. @ EACH END TOTAL OF 10 PER ELEVATION (2) 2X4 No.2 SYP DIAG. 2x4 BLOCKING BETWEEN BRACE W/ (3) 12d @ EA. TRUSSES WHERE TRUSS (DIAG. BRACE TO X-BRACING IS PRESENT AT COVER 5 TRUSSES) 4'-0" O.C. (AT SHEATHING 6'-0" MAX (Wl1 X4) 0'-0" TO 30'-0" (1) "X" BRACE SEAMS) OR 10--0" MAX (W/2X4) 30'-l" TO 60'-0 (3) "X" BRACE SECURE 2x PT. PLATE LVL/I-JOIST WITH �— V (1) "X" BRACE @ CENTER7 BACKER BLOCK (2) "X" BRACE DIVIDED EQUALLY AN HO W/ L W/ PER ELEVATION FROM CENTER TO END. ANCHOR BOLT W/IG 1x4 DIAGONAL WASHER SET IN HIGH PRE-ENG 1-JOIST BTM. CHORD SEE WOOD FASCIA, STRENGTH EPDXY 6" SECURE I -JOIST TO TOP PLATE MIN. EMBED. AT 32" OC 5/8" GYPSUM BOARD OR 1/2" HIGH BRACING, SEE w/ (2) 12d TOENAILS N W PLAN FOR LOCATION SECURE GABLE TO 2x8 STRENGTH CLG. BOARD MAY NOT BE PRE-ENG GABLE TRUSS DOUBLE TOP PLATE � y I REQUIRED O C. MAX PLATE W/ 12d's 8" STIFFBACK (AS PER TRUSS ENG) CONT. 2X4 SECURED W/ 2x4 OR 2x6 WOOD BEARING BTM. CHORD OF (2) 10d's @ EACH TRUSS WALL W/ SYP No 2 STUDS SEET MIN.HTT" MB A.B. WITH WOOD ROOF TRUSSES TO BE INSTALLED @ PLANS FOR SPACING. SINGLE MIN. 7" EMBEDMENT 10'-0" O.C. MAX. BTM. PLATE TO BE PT. PROVIDE BLOCKING TO SLAB & T 16d x ut PROVIDE DBL. TOP PLATE 1/2" GYP, WL. BD. POST NAILS T I POST., POST TO SIT DIRECTLY ON SLAB '< SEE SCHEDULE FOR SERIES BACKER BLOCK iHMESS 4500 3/4" WOOD PANELS 6000 (2) 1/2" WOOD PANELS 60 (2) 1/2" WOOD PANELS 90 2xLUMBER SERIES BACKER BLOCK THICIOEESS 4500 3/4" WOOD PANELS 6000 (2) 1/2" WOOD PANELS 60 (2) 1/2" WOOD PANELS 90 2x LUMBER BOND BEAM REQ. SECURE BT. PLATE TO ,a SLAB W/10d MASONRY NAIL a< <" HevdtorCafe 12" O/C STAGGERED. e ° ° lx4 BTM. CHORD BRACING 6'-0" O/C END WALL OR OTHER CompBance ADDITIONAL METAL ° " _ a" MAX., OR 2X4 BTM. CHORD BRACING END TYPE CONDITION, IF (lmv"al Engineenng CONNECTORS NOT n .� 1! ° ' �" " " a. 10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN Sciences REQUIRED WHEN NO ". e° COMMON NAILS AT EACH CHORD UPLIFT IS PRESENT. INTERSECTION TYP. LVL/1IVOOD POST CONNECTIONS BTM. CHORD BRACING BLOCK WALL W/ GABLE END 5 SCALE: 3/4"=1'-0" 6 SCALE: 3/4"=1'-0" 7 SCALE: 3/4"=1'-0" d . a PRE-ENG D TRUSS 4 I -JOIST CONNECTION @ L.B.W. 24" 24" MAX. w/ W OIST < 8" END SCALE: 3/4"=1'-0" (N O UPLIFT) MAX. SPACING 8"w/I-JOIST TRUSS BRG. OR BTM. END OF SHEATHING TYP. TYP. YP. PACING SEE FRAMING PLAN END MAX MAX MAX LEDGER BD. e • e 2" 1LT EXP. (2) 2X8LEDGE BOARD R w FROM LEDGER 3/4"BOLT/J- THE USE OF ALTERNATE MATERIALS MAY BE NOTCH DEPTH 1/4 D BOLT/J-BOLT W!2" LEDGER BOARD EDGE LEDGER BOARD TO BOLT/J-BOLT W/2" WITHTO EUSEDIJOIST1. BE USED WITH I -JOIST MIN, EMBED. (TYP) HOLE EDGE>5/8" WASHER .(TYP) BOL BE EXP" USED SO LONG AS THEY CONFORM TO THE MIN. EMBED. (TYP) BOLTS/J-BOLTS ARE PLACED INTO GROUTED CELLS, TALL FOLLOWING HOLE DIAMETER AROUND BOLT. FRONT 2. SPLICE OF FRONT AND REAR LEDGER < 2/5 D SGL. STUD LEDGER SHOULD LAP AMIN OF 1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS OUTER 1/3OF z q_0 z SPAN ONLY °' 3. ALL BOLTS TO HAVE WASHERS 00 A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS A - SIMPSON IUS1.81/16 G < 1400 LBS, U < 70 LBS W/ (2) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. a. EXP. BOLTS/J-BOLTS SHOULD (z) 2x12 EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES — HOLE EDGE >5/8" EMBED (14) 10d GALV. COMMON NAILS TO HEADER FL#17241 NOT BE ANY CLOSER THAN 6" SYP PT \I .: AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND B - SIMPSON IUS2.37/16 G < 1400 LBS, U < 70 LBS W/ (2) 3/4"WEDGE-BOLT/J-BOLT, 5" MIN. w E O/C. 00 Z ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE - EMBED (14) 10d GALV. COMMON NAILS TO HEADER FL#17241 5. ONLY LEDGER IN DIRECT THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO C - SIMPSON MIU3.56/16 G < 2900 LBS, U < 210 LBS W/ (4) 3/4"WEDGE-BOLT/J-BOLT, 5" MIN. (2) 2X8 CONTACT (REAR LEDGER) WITH REARFl, AND EMBED (24) 16d GALV. COMMON NAILS TO HEADER AND (2) 10dxl-1/2" GALV, NAILS TO JOIST SYP PT CMU REQUIRED TO BE P.T. LEDGER FORCES ALL AT HHE SAME TIME. FLOOR TRUSSES NOT EXPOSEDITO WIND ARE 2 FL#17241 D - SIMPSON HHUS7.25/10 G < 4140 LBS, U < 1610 LBS W/ (8) 3/4"WEDGE-BOLT/J-BOLT, 5" MIN. EMBED (16) 16d GALV. COMMON NAILS TO HEADER AND (10) 16d GALV. NAILS TO JOIST BTM. HOLE DIAMETER FL#25749 PLATE < 3/5`D DBL. STUD E - SIMPSON MIU4.75/16 G < 3455 LBS, U < 210 LBS W/ (8) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. EMBED 16d GALV. COMMON NAILS TO HEADER AND (2) 10dxl-1/2" GALV. NAILS TO JOIST FL#17241 SUBJECT TO F1 AND F2 FORCES. WOOD LEDGER STUD NOTCHING ATTACHMENT DETAIL ALTERNATE MATERIALS 10 I -JOIST WOOD LEDGER DETAIL 11 SCALE 3/4"=1'-0" AND BORING LIMITS SCALE:3/4"=1'-0" SCALE 3/4"=1'-0" FLOOR JOIST LEDGER SCHEDULE MARK SIZE BOLT SIZE ENDSPAGNG CEOMSPAGNG A DOUBLE SYP 2x8 1/2" 8" MAX. 24" O/C MAX. B DOUBLE SYP 2x12 (2) 3/4" 8" MAX. 24" O/C MAX. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 PIZ, W 01 U W O F U w q A FF ti • � i + I J SVBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT 04321.201 101R1 MODEL 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS (I —JOIST) 160 MPH EXP. C ARCHITECT STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 10 28 21 SCALE: 1/4"=1'-0" SHEET S3. IA SIMPSON H6 W/ (8)8d COMMON NAILS 2x STUDS SIMPSON H6 W/ (8) 8d EACH END COMMON NAILS, EACH END EVERY STUD OR ON EACH END OF "BUNDLE" OF STUDS = REFER TO NAILING II} PLYWOOD FLOOR SCHEDULE ON SHEET SHEATHING REFER TO NAILING NI lilllfll SN1 FOR FASTENER TYPE AND SIZE 8" CMU WALL SCHEDULE ON SHEET LREINF �I 2 ' REINF PER PLAN SN1 FOR FASTENER 8" CMU WALL DBL. 2X8 SYP #2 LEDGER. TYPE AND SIZE PER PLAN SEE BOLT SCHEDULE, PER ELEVATION 3/4" 10/S3.1A. '3i4" PER ELEVATION $ �' N SCREW PATTERN �Ia�r/ 7­1LL 3 r SCREW PATTERN WO= p I -JOIST (SEE I VO z lull �Ua FRAMING PLAN) � 0x N 0 a PER ELEVATION m N C^w PER ELEVATION Z (2) 2x4 P.T. W/ MASONRY NAILS DBL 2X12 SYP #2 LEDGER. SEE 24" MAX. I -JOIST (SEE 2x4 P.T. CEILING FRAMING PLAN) @ 12" O.C. BOLT SCHEDULE, 10/S3.1A. NAILER W/ MASONRY NAILS SIMPSON SPH4/SPH6 BTM. @ 12" O.C. I -JOIST LVL PLATE STRAPS W/ 10d x 1 lX2 FIRE -STOP 1/2"HDGNAILS SECTION DETAIL 1X2FIR E-STOP SECTION DETAIL WALL / FLOOR FRAMING, AT I -JOISTS PERPENDICULAR AT I -JOISTS PARALLEL I -JOIST PARALLEL TO WALL TO EXTERIOR WALL TO EXTERIOR WALL 2 SCALE: 3/4"=1'-0" SCALE:3/4"=1'-0" SCALE:3/4"=1'-0" PRE-ENG GABLE TRUSS 2x4 BLOCKING BETWEEN TRUSSES STRAP TRUSS TO PL. —A PRE-ENG fOr AT FIRST TWO BAYS 4'-0" O.C. (AT SHEATHING SEAMS) 8 PRE-ENG'D WOOD SEE SCHED. BELOW ROOF TRUSS Unfv"I Cede (BLOCKING NOT SHOWN FOR CLARITY) (TYP) @ 24" O.C. Scierr"e�ing MAXSS a 2X4 DIAGONAL BTM. CHORD PER ELEVATION BRACING. SEE PLAN FOR FOR STRAPPING LOCATION �.yg,„ VERIFY PRE-ENG ROOF TRUSS SECURE 2x6 PT. PLATE TO BLK "' '' W/ TRUSS PLAN TRUSS TO TOP PLATE 5/8" GYPSUM BOARD OR 1/2" HIGH W/ 1/2" DIA. ANCHOR BOLT W/ 2" A -SIMPSON MTS12 STRENGTH CLG. BOARD 44/46 SYP NO.2 WASHER SET IN HIGH U < 990 LBS W/ (14) 10d SECURE TRUSS TO TOP PLATE w/ (2) WOOD POST TO STRENGTH EPDXY 6" MIN. GALV. NAILS. 16d TOENAILS SLAB. SEE EMBED, AT 32" OC MAX. B - (2) SIMPSON MTS12 DOUBLE TOP PLATE SCHEDULE SECURE GABLE TO 2x8 P.T. U < 1420 LBS W/ (14) 10d BELOW FOR PLATE W/ 12d's 8" O.C. MAX GALV. NAILS EA. STRAP 2x4 OR 2x6 WOOD BEARING CONNECTION WALL W/ SYP No 2 STUDS SEE FL#17239 PLANS FOR SPACING. SINGLE CONC POURED BTM. PLATE TO BE PT. LINTEL COURSE PROVIDE DBL. TOP PLATE 0 PROVIDE BLOCKING SIMPSON SPH4 OR SPH6 BTM 1/2" GYP. WL. BD. + AND TOP PLATE ANCHORS W/ 10d x 1 1/2" COMMON NAILS SECURE BT. PLATE TO SLAB W/ CONT. 2x4 SECURED W/ (2) 10d's @ EACH FILL ALL HOLES, DO NOT USE 10dx3" 1/2"x9" WEDGE ANCHOR W/ 2' WASHER SET IN HIGH STRENGTH TRUSS/VVOOD POST CONNECTIONS TRUSS TO BE INSTALLED @ 10'-0" O.C. MAX. EPDXY 5-1/2" EMBED. MIN. @ 16" 10a 10b 10c OC MAX. GABLE END BRACING W/ PRE-ENG GABLE TRUSS @CMU WALL as ° . TRUSS TO POST CONNECTION SCALE: 3/4"=1'-0" Q °`b A - SIMPSON MTS-12 U < 990 LBS W/ (14) 10d GALV. NAILS. 0 t B - SIMPSON HTS-20 U < 1310 LBS W/ (20) 10d GALV. NAILS. a. C - 2-PLY-SIMPSON VGT/HDU4 U < 4565 LBS VGT TO TRUSS W/ (16) 1/4"x3"SDS, (1) 5/8"° A.T.R. TO HDU4 AND (10) 1/4" X 2 1/2" SDS TO POST TRUSS CONNECTION @ L.B.W. SLAB 9a gb POST TO CONNECTION SCALE: 3/4"=1'-0" A&B - SIMPSON ABU44Z POST BASE <U:1,900 13:5,660 W/ 5/8 DIA. x 6" EXP. BOLT SIMPSON ABU46Z POST BASE <U:2,300 G:1()335 W/ 5/8 DIA. x 6" EXP. BOLT C - SIMPSON HTT5 POST ON SLAB <U:4,565 W/ 5/8" A.B. WITH MIN. 7" EMBEDMENT TO SLAB & (26) 16d x 2-1/2" NAIi_S TO POST. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 9 W U W 0 h �4 V A F A E4 SVBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL 4EHB " 2605— HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS (I —JOIST) 160 MPH EXP. C ARCHITECT - STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 10 28 21 SCALE: 1/4"=1'-0" SHEET S 3. 1� SIDE VIEW VTCR SPACING (1) AT EA, PRE-ENGINEERL.v VALLEY TRUSS CONNECTION SCALE N.1.5. Reviewed for code Compliance Universal Engineenng Snlerm 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 h W W F G W A h A E: ti S'C7HDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT 04321.201 101R1 MODEL: 4EHE "2605- HAYDEN" GARAGE S WING: LEFT PAGE: DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 rJMJLJN A 2128 DATE: 10 / / SCALE: 1/41=1'-0" SHEET �oI I fcU19cW SECOND FLOOR DECK PLAN SCALE: 1/4" = V-0" Reviewedfor Code Universal Ergnewft Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti W v W 0 ti �0. v Q F A C: ti SUHDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN2 GARAGE SWING: LEFT PAQE: SECOND FLOOR DECK PLAN 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA Nov 1 6 2021 WHAEL C. ANDERSON AR NO 17305 ]PRINT // 10 28 21 D SCALE: 1/4"=1'— 0" SHEET S A a'. �.' N woumolmo Into go -no yommy 0) N 2194 HWY A1A, SUITE J301INDIAN HARBOUR BEAFLORIDA 32937 PH: 321-802-359]www.abdesigngroup. AA #: 0003325 F W W U W O F U W A A (r ti RevewedfOr Co de Compliance . SUBDIV. 8e LOT : universal Engineering Sciences CREEKSIDE PHASE 2 LOT #101 PROJECT{# 04321.201 101R1 MODEL: 4EHB "2605— HAYDEN" GARAGE SWING: LEFT PAGE: SECOND FLOOR DOWEL PLAN 160 MPH ESP. C ARCHITECT STATE OF FLORIIA MICH49L 8'&EFSON AR NO 17305 PRINT 28 10 21 DATE: / /' SCALE: 1/4"=1'-01 t FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILLALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDERACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. HEADER SCHEDULE MARK 8r SIZE DESCRIPTION REMARK 1� (2) 2X8 BEAM SCHEDULE INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL / T.O.A. = TOP OF ARCH / T.O.S = TOP OF SLAB ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION (PSI) VVxHSIZE REINFORCEMENT STIRRUPS REMARKS BTM, TOP MID SIZE SPACING B81 MASONRY 3000 8xl6 — (1) #5 (1) #5 N/A — GROUTED SOLID [—BB-21 MASONRY 1 3000 1 8x8 — (1) #5 — N/A — GROUTED SOLID SEE SHEET S5.1 A FOR SAFE LOAD TABLES p 1 1 1 ♦ 81`16-1T/0MlOB 8F16-lT/OM/OB 8F16-lT/0M/0B ♦♦ 1 2 I 1 0 1 F_ 1 ♦♦ 1 I GT 1 ♦, � 1 `♦ 1 U.N.O. PROVIDE BB2 WHERE I 1 1 ROOF TRUSSES BEAR, ♦, �� 1 1 TOP OF WALL EL 18'-8" 1 1 ♦ � 1 1 ,♦ � 1 400 � �♦ i i � ` 1 1 1 ♦ ♦ 1 1 1 1 ♦ ♦ 1 ♦% ♦♦ 1 GT `♦ ,♦ ,♦ 1 > ♦ `♦ `� 1 400 1 I GT ♦ ` ♦, 1 b 4 , ♦`♦ ♦,♦ ♦♦♦ ' j 8F16-lT/OM/OB 1 1 ♦♦ 1 ♦ -------=11 Ir 1�1 1 1 I8F16-lT/OM/OB 8F16-1T/OM/0B 8F16-lT/0M/0B♦♦♦ 1 � � 1 L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -- SECOND FLOOR LIFT BEAM PLAN SCALE: 1/4" = 1'-0" INSwaim RewewedforCode CoPnpllence Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti W U W 0 F R V 4 F A ti SX;BDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #101 MODEL: 4EHB "2605- HAYDEN" SWING: LEFT PAGE: SECOND FLOOR LIFT BEAM PLAN 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 10 28 21 SCALE: 1/4"=1'-0" SHEET S 5 - I - "LOTT'S CONCRETE" / "CAST-CRETE" / "QUALITY" SAFE LOAD TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS T SAFE LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT SAFE PLF LOAD SAFE LOAD -POUNDS PER LINEAR FOOT TYPE LENGTH SUS 8/8-0B /16-1T/OB 20-1T/OB /241T/OB 8-1T/OB 32-1T/OB TYPE LENGTH 8�8 PLAIN 8�8 SOLID TYPE LENGTH 8/8-1T 8/16-1T 8/20-1T 8/241T 8/28-1T 8/32-1T 8/8-1B 116-1T/1B 0-1T/1B 4-1T/16 28-1T/1B 32-1T/1B 8/8-2T 8/16-2T 8/20-2T 8/24-2T 8/28-2T 8/32-2'T 3'-6" PRECAST 1436 952 3114 4217 5321 6426 7531 3'$" PRECAST 689 1024 3'-6" PRECAST 1569 3524 4394 5263 6132 7001 2465 6113 6385 7708 9031 10000 1569 3524 4394 5263 6132 7001 4'-0" PRECAST 1065 700 2305 3125 3945 4765 5587 4,-0" PRECAST 514 763 4'-0" PRECAST 1363 3060 3815 4570 5325 6079 1961 6113 7192 6524 7627 8751 1363 3060 3816 4570 5325 6079 41-6" PRECAST 819 533 1770 2400 3033 3s66 4300 4 -6" PRECAST 398 591 4 -6" PRECAST 1207 2582 3375 4043 4711 5379 1625 5743 7547 6752 6541 7565 1207 2707 3375 4043 4711 5379 5'-4" PRECAST 931 1247 1999 2560 3123 3686 4249 5'-4" PRECAST 411 411 5'-4" PRECAST 1016 1806 2374 2944 3513 4084 1319 4460 7196 7342 5780 6259 1016 2276 2838 3399 3961 4084 5°-10" PRECAST $17 1024 1631 2090 2549 3009 3470 5'-10" PRECAST 340 339 5"-10" PRECAST 909 1499 1971 2443 2915 3387 1161 3693 5877 6036 6548 5776 929 2080 2593 3107 3620 4133 6'-6" PRECAST 692 1139 3227 3031 3707 4383 5061 6'-6" PRECAST 410 721 6"$" PRECAST 835 1201 1578 1955 2332 2709 1139 3227 4598 7054 10000 8825 835 1868 2329 2790 3251 3712 T-6" PRECAST 570 938 2498 2205 2698 3191 3685 7'-6" PRECAST 303 534 T-6" PRECAST 716 900 1181 1462 1743 2025 938 2498 3408 4864 7067 6472 727 1624 2.025 2426 2827 3228 91-4" PRECAST 428 633 1593 2204 2481 2818 2621 914" PRECAST 192 384 91-4" PRECAST 464 586 767 948 1129 1310 639 1674 2298 3081 4099 4899 572 1318 1643 1969 2164 2519 10 -6" PRECAST 388 487 1247 1767 1904 2163 2028 10, -6" PRECAST 151 3®1 10 -6" PRECAST 356 468 755 899 1042 550 1407 1897 2781 3222 3784 504 1180 _612 1472 1763 1710 1989 11'-4" PRECAST 330 5" 1312 1742 2252 2868 3630 11'-4" PRECAST 132 417 11'-4" PRECAST 430 406 530 653 777 872 544 1312 1742 2252 2868 3652 466 1042 1372 1643 1470 1710 12'-0" PRECAST 308 507 1210 1596 2048 2586 3191 12'-0" PRECAST 111 370 12'-0" PRECAST 383 366 476 587 698 783 507 1210 1596 2048 2586 3171 440 940 1300 1560 1314 1476 13'-4" PRECAST 270 433 1045 1365 1732 2157 2535 13'-4" PRECAST 82 298 13'-4" PRECAST 308 303 393 484 575 645 414 1045 1365 1732 2316 2605 396 780 1057 1312 1071 1203 14'-0" PRECAST 254 388 978 1272 1606 1988 2279 14'-0" PRECAST 71 293 14'-0" PRECAST 279 278 360 443 526 609 390 978 1272 1606 1950 2389 378 717 961 1192 975 1133 14'$" PRESTRESSED N.R. NR NR NR NR NR NR 14'-8" PRESTRESSED N.R. 283 14'-8" PRESTRESSED 239 422 506 626 746 865 ,� 1079 9429 1824 2277 2712 246 663 980 1237 1474 1715 15'-4" PRESTRESSED N.R. NR NR NR NR NR NR 15'4" PRESTRESSED N.R. 252 15'-4" PRESTRESSED 224 387 464 574 684 793 412 1014 1340 1703 2118 2513 230 616 908 1134 1353 1672 17'-4" PRESTRESSED N.R. NR NR NR NR NR NR 17,4" PRESTRESSED N.R. 183 -4 17'" PRESTRESSED 187 326 365 451 587 680 300 856 1121 1413 1739 2047 192 506 720 501 1135 1312 19'-4" PRESTRESSED N.R. NR NR NR NR NR NR 19'4" PRESTRESSED N.R. 148 19'-4" PRESTRESSED 162 266 348 430 513 595 235 736 959 1200 1467 1716 166 429 623 803 950 1098 21-4" PRESTRESSED N.R. NR NR NR NR NR NR 21'-4" PRESTRESSED N.R. 125 21'-4° PRESTRESSED 142 219 308 381 464 527 180 598 833 1038 1168 1468 142 373 537 690 816 943 22'-0" PRESTRESSED N.R. NR NR NR NR NR NR 229-0" PRESTRESSED N.R. 116 221-0" PRESTRESSED 137 226 290 359 428 497 165 550 784 992 1203 1381 137 358 513 659 779 900 24'-0" PRESTRESSED N.R. NR NR NR NR NR NR 241-0" PRESTRESSED N.R. 91 24'-0" PRESTRESSED 124 174 245 302 360 418 129 450 654 824 1014 1147 124 319 455 581 687 793 - ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY QUALITY 2018 EDITION, LOTTS MAY 2015 EDITION - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE AND CASTCRETE MAY 2015 EDITION. - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE DIVISION ACCEPTANCE #-. 19-0130.13 ROvkwed For Code Univ Sc ei X` nces 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 w w U w co w q F A SUBDIV. LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: SAFE LOAD TABLES 160 MPH EXP. C ARCHITECT - STATE OF FLORIDA NOV 1 6 2021 MICHAEL C. ANDERSON AR NO 17305 r"&411 ` DATE: 10 28 21 i SCALE: 1/4"=1'-0"' SxEET S5. 1//�� A FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HOG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2" HOG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HOG NAILS, FILLALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILT[ X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. 14. BOTTOM CHORD BRACING, DIAGONAL BRACING AND GABLE END BRACING SHOWN ON THE FRAMING PLANS AND DETAIL ARE DRAWN AS A DIAGRAMMATIC PURPOSES FOR MINIMUM SPANS AND MAXIMUM SPACING. THESE DRAWINGS ARE INTENDED AS A GUIDELINE FOR CONSTRUCTION AND DO NOT NECESSARILY REFLECT ALL ACTUAL CONDITIONS THAT MAY ARISE IN THE FIELD. FIELD CONSTRUCTION SHOULD CLOSELY PARALLEL THE BRACING DIAGRAMS WITHIN THESE MINIMUM AND MAXIMUM TOLERANCES. ADJUSTMENTS IN THE FIELD ARE ACCEPTABLE FOR FIELD CONDITIONS SUCH AS INTERFERENCES WITH TRUSS WEBBING, SHEETING ETC. IN SITUATIONS WHERE THE DIAGRAMS LOCATION AND ACTUAL TRUSS WEBBING CONDITIONS CONFLICT, THE CONTRACTOR SHALL PLACE THE DIAGONAL BRAE ADJACENT TO THE TRUSS WEB AS CONDITIONS ALLOW. TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. GIRDER/TRUSS I TRUSSES W/2X4 W/2X6 BOTTOM BOTTOM CHORD CHORD 2x4 SCAB NAILED TO n /� \— DIAGONAL END JACK TRUSS BOTTOM DIY/yJ\I� gRACING/BOTTOM CHORD W/MIN (4) 10d CHORD BRACING NHERE APPLICABLE NAILS FOR EACH CHORD CONNECTION DISSIMILAR BOTTOM CHORD BRACING ® END TRUSSES W/2X4 BOTTOM CHORD GIRDER/TRUSS W/2X6 BOTTOM CHORD DIAGONAL OT/-2x4 SCAB NAILED TO TRUSS BRACING/BOTTOM I/IL�I Ilrl/rl/'171��IY`il TRUSS BOTTOM CHOR CHORD BRACING W/MIN (4) 10d NAILS FOR EACH CHORD CONNECTION \ DISSIMILAR BOTTOM CHORD BRACING ® MID RUN a a a ve91Reviewed for Code uniCompliance s� Engineering aa a -- • _ II 11 11 11 11 11 11 11 11 11 11 11 11 II = II II II II II II II II II II II II II II II II TRUSSES W/2X4 II II I) II II (I II II II II II II I) II BOTTOM CHORD CJ = II II II II II II II II II II II II II II 1 C ti�A MG �W 3.1 A7 DIAGONAL 6 BRACING/BOTTOM IA5 I 1 I CHORD BRACING CONNECTOR SCHEDULE CONTROL DATE: 01/21/2021 MiTek USP SIMPSON MiTek USP SIMPSON DES. UPLIFT GRAVITY DES, UPLIFT GRAVITY FASTENER FASTENER HTA 16-I8 1625 META-16 1450 LE) 10d X 11/2" 1-PLY, (7) 16d 2-PLY, EMBED 4" (8) 10d x 11/2" 1-PLY, (6) 16d 2-PLY, EMBED 4" (2) HTA 16-18 2430 (2) META-16 1985 (12) 10d x 11/2" 1-PLY, EMBED 4" (10) 106 x 11/2" 1-PLY, EMBED 4" HTA 16 1870 HETA-16 1810 (10) 10d X 11/2", (8) 16d 2-PLY, EMBED 4" (9) 10d x 1112" 1-PLY, (8) 16d 2-PLY, EMBED 4" HTA 20 1870 HETA-20 1810 (10) 10d x 11/2", (8) 16d 2-PLY, EMBED 4" (9) 10d x 11/2" 1-PLY, (8) 16d 2-PLY, EMBED 4" (2) HTA 20 2430 (2) HETA-20 2035 (12) 10d x 11/2", 1-PLY, EMBED 4" (10) 10d x 11/2" I -PLY, EMBED 4" 2500 (10) 16d 2-PLY, EMBED 4" (12) 16d 2-PLY, EMBED 4" 2 LUGT-2 1655 LGT-2 1885 BLK (5) 1/4"x 3" Wedge-Bolt+Anchors, WOOD (16) 10d (7) - 114" x 21/4" TITEN, WOOD (16) 16d LUGT-3 3380 LGT3-SD52.5 3480 CONC (4) 3/8' X 5" Wedge-Bolt+Anchors, WOOD (12) WS25 (12) SDS 1/4"x3" TO GIRDER, (4) 3/8" x 5" TITEN HD TO WALL DHTA-20 2430 DETAL-20 2480 (16) - 10d x 1 1/2, 1 PLY ALTERNATE USE OF (2) HTA-20 ACCEPTABLE (18) - 10d x 11/2, 1 PLY ALTERNATE USE OF (2) HETA-20 ACCEPTABLE MUGT15+ 3945 MGT+ 3965 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (22)10d TO WOOD) (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (22) 10d TO WOOD H UGT2+ 9575 HGT-2+ 10690 WOOD (8) 10d, MASONRY (2) 3/4" A.T.R (2) 3/4" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (16) 10d TO WOOD H UGT3+ 9860 HGT-3+ 10690 WOOD (8) 10d, MASONRY (2) 3/4" A.T.R (2) 3/4" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (16)10d TO WOOD LPTA 1510 PARALLEL TO WALL 1470 PERPENDICULAR TO WALL LTA2 1210 PARALLEL TO WALL 1210 PERPEN DI CULAi TO WALL (10)I0dx 11/2" (10)10dx 1-1/2" MUGT15 3945 VGT 4940 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (4) 10d TOP/(6) 10d FACE/(12) 10d BACK OF TRUSS (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (16)SOS 1/4"x3" HUGT 9575 (2) VGT 7185 (2) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (8) 10d (2) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (32) SDS 1/4"x3" MTW 12 965 MTS-12 990 (14) 10d x 1112", (14)10d (14) IOd X 11/2" HTW 16 1355 HTS-16 1310 (16)10d X 11/2", (16) 10d (16)10d X 11/2" HTW 20 1355 HTS-20 1310 (24) 10d X 11/2", (20) 10d (24) 10d X 11/2" HTW 24 1355 HTS-24 1310 (24) 10d X 11/2", (20) 10d (24) 10d x 11/2" LSTA 12- 930 LSTA-12++ 925M(26) 10) 10d (10) 10d LSTA 18++ 1235 LSTA-18 ++ 123514)l0d (14)10d MSTA-18 ++ 1310 MSTA-18++ 131514) l0d (14) 10d MSTA-24++ 1640 MSTA-24++ 164018) 10d (18) 10d MSTA-30++ 2065 MSTA30++ 205022) SOd (22) 10d MSTA-36++ 2065 MSTA-36++ 205010d (26) 10d KSTI236 2765 MSTI-36 380036) 10d X 1 1/2" (36) SOd X 11/2" KTSI248 5105 MSTI-48 5070 (48) 10d X 11/2" (48) 10d X 11/2" LFTA6 980 H6 1055 (16) 8d x 11/2", (16) 8d) (8) Ed TO PLATES, (8) Ed TO STUDS 5PT4 875 SP4 825 (6) 10d TO STUDS (6) 10d TO PLATE (6) 10d x 11/2" TO STUDS MP34 525 IN Fl @ 160% A34 430 (4) 8d x 11/2" TO BEAM, (4) 8d x 11/2" TO POST. (4) Ed x 1 1/2" TO BEAM, (4) 8d x 1 1/2" TO POST, HHCP2 680 HCP2 590 (10) 10d x 1 1/2" TO TRUSS, (10) 10d X 1 1/2" TO PLATE (12) 10d X 1112" RT16A 1020 H10A 1040 (9)10d x 11/2"TO TRUSS, (8) lOd X 11/2" TO PLATE (18) 10d X 11/2" MUGT15 & PHD4A 4175 VGT& HDU4 4940 (28)10d TO TRUSS, (10) WS3 WOOD SCREWS TO POST W/ 5/8" THREADED ROD (16)-SDS 1/4"x3" TO WOOD, (10)-SDS 1/4"x21/2" W/ THREADED ROD, (2) NUTS/WASHER/2 PLY MUGT15 & PHD4A 4175 VGT& HD7B 4940 (28) IOd TO TRUSS, (10) WS3 WOOD SCREWS TO POST W/ 5/8" THREADED ROD (16)-SDS 1/4"x3" TO WOOD, (3)-3/4" STUD BOLTS W/ THREADED ROD, (2) NUTS/WASHER/2PLY PAU44 2535 6775 ABU 44Z 2300 7750 Ili 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC., (12) 16d TO WOOD (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED.) IN CONC., (12)16d TO WOOD PAU66 2455 16005 ABU 66Z 2190 18205 (L) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC., (12)16d TO WOOD (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED.) IN CONC., (12)16d TO WOOD LTS19+++ 1205 LTT19— 1310 (1 ) 3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONIC., (8)10d TO WOOD (1) 3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED.) IN CONC., (8)10d TO WOOD LTS20B +++ 1100 LTT20B+++ 1500 1 (1) 3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONIC., (10)10dx 1-1/2 TO WOOD (1) 1/2" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED.) IN CONC., (10)10d TO WOOD HTT45 4160 HTT4 4455 (1) 5/8' A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED) IN CONC., (18) 16d X21/2" (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED,) IN CONIC., (26) 16dX Z 1/2" HTT45 5005 HTT5 5090 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED) IN CONC., (26) 16d X2112" (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED,) IN CONIC., (26) 16dX 21/2" UPHD11+ 14395 H SDQ11-SDS 11810 (i) 1" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 10" EMBED) IN CONIC., (24) W53 WOOD SCREWS (1) 1" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 10" EMBED.) IN CONIC., (24) SDS Y." x 2%" WOOD SCREWS PHD5A 6525 HD7B 6645 (115/8" A.B. IN HIGH STRENGTH EPDXY, (MIN 7" EMBED) IN CONC. (14) WS3 WOOD SCREWS (1) 7/8" A.B. IN HIGH STRENGTH EPDXY, (MI N. 7" EMBED.) IN CONIC., (3) 3/4" STUD BOLTS TO WOOD TOX8 7870 (1) 7/8" A.B. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC. (3) 7/8" STUD BOLTSTO WOOD NFM35X12U 2580 7130 MBHA MBHA1.25 3475 5330 f 1) 1/2"' 1-BOLT W MIN 6' MYNA BOLTSLTW INS EMBED &NOT LESSTHAN 4" FROM EDGE OF CONIC W/3/4"DIA ITW RAMSET/REDHEAD OR OR EQ W/MIN 5"EMBED INSTALLED IN FACE. (14)10d AT101ST III 3/4"A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 6.75" EMBEDMENT) IN C.M.U. TOP, (1)3/4" A.T.R IN HIGH STRENGTH EPDXY, (MIN. 6.75" EMBEDMENT) IN C.M.U. FACE, (18) 10d TO BEAM HUS4121F 3615 2710(100%) HUSC412 (WOOD) 3435 2635(100%) (10) 16d TO HEADER, (10)16d TO WOOD (10)16d TO HEADER, (10)16d TO WOOD 3325(125%) 3220(125%) 1ID410IF (CMU) 1110 3010 HUC410 (CMU) 1800 4500 (18)1/4"" x 3"" WS3 SCREWS, (10) 10d TO "TAPPER+, (10) IOd TO WOOD WOOD. USP (20) 3/16 " (18) 1/4 x 2-3/4.. TITEN 19 PER FLANGE) TO CMU, (10) 10d TO WOOD: HD210-21F (CMU) 1950 3080 HUC210-2 (CMU) 1800 4500 (18) 1/4"" x 3"" W53 SCREWS, (10) 10d TO WOOD. USP (20) 3/16"" TAPPER+, (SO) lOd TO WOOD (18) 1/4" x 2-3/4" TITEN (9 PER FLANGE) TO CMU, (10) IOd TO WOOD: HD210-31F (CMU) 2795 5015 HUC210-3 (CMU) 1800 4500 (.18) 1/4"" x 3"" W53 SCREWS, (10) 10d TO WOOD. USP (20) 3/16"" TAPPER+, (10) 10d TO WOOD (18) 1/4 x 2-3/4" TITEN (9 PER FLANGE) TO CMU, (10) 10d TO WOOD: LGUM26-2 2125 6065 LGUM26-2-SD 1430 5595 Q4)3/8"X4"Wedge-Bolt+ Anchors, WOOD (4) W53 WOODSCREWS (4)3/8 x4 TITEN HD ANCHORS (2 PER FI%NGF)TO CMU, (4)1/4X 2-1/2 SDS SCREWSTOWOOD IA3 I I I I I PRE -FABRICATED I ZOOF A2 TRUSSES @ 24" O.C. TYP) = A RIDGE _ _ _=41= # / - A3 - - 22"X307'__7 - I I ATTIC I I I A4 IkCCESS L _ I I I I I T 1 h N ,/��� ROOF FRAMING PLAN SCALE: 1/4" = V-0" CJ1 CJ3 0 t` CA CJ1 i[6 � U O O m o N O @ LL O Z zFj O � Qm O � K O x O 1A .11 O U O O o m o � N OUa ILL Q Z Z Q °m O O 1C O n 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0011 00 F W v W 0 0. A F A SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT# 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: ROOF FRAMING PLAN AND NOTES 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA i NOV 1 6 2021 WCHAEL C.'ANDERSON AR NO 17305 PRINT 10 28 21 DATE: / / SCALE: 1/4$'=1'-0" SHEET S 6 GABLE -END HIP ROOF ROOF WIND DESIGN PRESSURES NET (GROSS) ASCE 7-16 ZONE 1 = 58.00 PSF (68.00) ZONE 3 =66.50 PSF (76.50) ZONE 2e = 66.50 PSF (76.50) ZONE 3e = 76.60 PSF (86.60) ZONE 2n = 76.60 PSF (86.60) ZONE 3r = 91.70 PSF (101.70) ZONE 2r = 76.60 PSF (86.60) "A"= 4'-0" END ZONE DISTANCE BASIC WIND SPEED: 160 MPH EXPOSURE CATEGORY: "C" RISK CATAGORY: II APPLICABLE INTERNAL PRESSURE COEFFICIENT: +/- 0.18 ROOF DIAPHRAGM FOR ASPHALT SHINGLE ROOF, USE MIN 19/32" STRUCTURAL SHEATHING EXP 1 (40/20), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE MIN. 19/32" STRUCTURAL SHEATHING EXP 1 (40/20).(SEE TABLE FOR FIELD AND EDGE SPACING) SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 10d RING SHANK GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE END. ROOF/ WALL/ FLOOR SHEATHING_ FASTENER SCHEDULE NAIL REQUIREMENTS SIZE HEAD LENGTH DIA. TENSILE STIR. SHANK ASTM 10d RING SHANK, 2 1/2" 0.131 F1667 SCREW SHANK 170,000 RING RINGS RSRS-03 Sd RING SHANK, 2 3/8" 0.113 PER I PER NCH) SRS 01 RSRS SCREW SHANK 8d RING SHANK, PNEUMATIC 2 3/8" 0.113 F1667 RSRS-01 SCREW -NAILS EXTERIOR SHEATHING USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & ✓ BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SEE DETAIL. ROOF SHEATHING ATTACHEMENT SPACING ZONE 1: 10d NAILS @ 4" O.C. ON EDGE AND 6" O.C. IN FIELD ZONE 2e, 2n, 2r: 10d NAILS @ 4" O.C. ON EDGE AND 4" O.C. INFIELD ZONE 3,3e, 3r: 10d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED AND ADHERES TO ASCE 7-16 8d RING SHANK GUN NAILS @ 4" O.C. TOP & BOTTOM EDGES „ • J Z z Y z Lu LL. = ZO Z EE 00 =(o I NINL3 RAFTER OR TRUSS ROOF SHEATHING (0 _ z F 00 m BUILDING LENGTH ROOF SHEATHING LAYOUT AND ENDWALL BRACING FOR GABLE END FRAMING NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @ 16"O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING @ 16" O.C. FIRST 4 BAYS W/ (2)12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS 2/ BLOCKING PER NAILING SCHEDULE C10d RINGSHANK GUN NAILS SEE "ROOF SHEATHING ATTACHMENT' TABLE FOR PELD SPACING FOR STRUCTURAL (—#8'2" DECK STREWS @ 6"-9" O.C. MAX @ EQGES & 12" ).C. MAX IN FIELD. UNTIJREADED SHANK TO E)TEND BEYOND THICKNESS OF SUB -FLOOR IHEATHING rYP. 3/4" T&G SUB -FLOOD [ECKING GLUED TO ALL EXPOSED MEMBERS GENERAL NOTES: ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C30IC33M. MAXIMUM AGGREGATE SIZE SHALL BE 3/4", WOOD: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS, APPLICABLE BUILDING CODE STANDARDS: FBC-R 2020, 7th EDITION ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 314". ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, TMS 402/602-16 AISI SPECIFICATION FOR THE DESIGN OF PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONS DRAWINGS. SEAMS LAPPED 61NCHES AND SEALED WITH ADHESIVE TAPE. PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND FORM -WORK: CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347 LATEST W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT EDITION,"RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. CONTAINS MORE THAN'/z" OF HEARTWOOD. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT EXCLUSIONS FROM THESE PLANS: MINIMUM NAILING PER FBCR 2020, 7th EDITION. SEE NAILING SCHEDULE ON PLANS. TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS OF THE WORK. ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL.DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. SYP #2. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS WELDED WIRE MESH: AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, WELDED WIRE MESH, SHALL BE ASTM A1064/A1064M, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE WOOD TRUSSES: TEMPORARY BRACING, GUYS OR TIE -DOWNS. ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE SUPPORTED WITH 2" CHAIRS SPACED 3'-0" OC, EACH WAY. TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0,036" AND BE MANUFACTURED FROM STEEL TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A615A615M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615 MEETING THE REQUIREMENTS OF ASTM A4461A446M, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE DESIGN LOADS: W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS, DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "BCSI LATEST EDITION" AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf REVIEW. WOOD TRUSSES. 20 psf TOP CHORD -non-concurrent TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" 10 psf BTM CHORD -non-concurrent #5 BAR - 30" #7 BAR - 42" TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION. INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI/ASCE 7 88: 1990. psf TOP CHORD psf TOP CHORD (7 (1 (7 psf w/ASPHALT SHINGLES) (10 psf w/ No GYPCRETE) ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 10 psf BTM CHORD 5 psf BTM CHORD THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH DEAD LOAD TO RESIST WIND UPLIFT: 10psf MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAVINGS FOR ALTERNATE CONNECTION DETAILS AT WALL. TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. BALCONY LIVE LOAD 60 psf STAIRS LIVE LOAD 40 psf RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS, DOWEL ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING WIND: DEAD LOAD SPEED =160 MPH 3- SECOND GUST INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL (ASCE 7-16 (FBC R2020) EXPOSURE C, RISK CATEGORY II) LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WITH LIMITED DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE STORAGE: 20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR) WITHOUT THE APPROVAL OF THE ENGINEER. STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50psf, PASSENGER PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: MASONRY: PLAN SHOWING COMPONENT LAYOUT, SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE LICENSED PROFESSIONAL ENGINEER. SHOP DRAWING REVIEW: "SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE MASONRY STANDARDS JOINT COMMITTEE. PROVIDED BY THE TRUSS ENGINEER. COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE fm = 2000 PSI. BLOCK SHALL BE PLACED USING OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ALL TRUSS TO TRUSS CONNECTIONS. OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN, THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION WRITING BY THE ARCHITECT. TO CONSOLIDATE GROUT. FOUNDATION/ SITE PREPARATION: TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF THE SHALL BE 318" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557, TREAT ALL CELLS TO BE FILLED. SOIL FOR TERMITE PROTECTION. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY REINFORCING. SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE Reviewed far Code GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE Universal EngeemV MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL STRUCTURAL STEEL: Sciences BE MADE BY THE GEO-TECH. ENGINEER. THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE CONCRETE: SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, 9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, STRUCTURAL STEEL SHALL BE ASTM CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: A36/A36M, Fy = 36 ksi FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM A500/A500M, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S, Fy = 2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. 3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB. ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO OTHER BOLTS SHALL BE ASTM F3125IF3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5"+/- PRIOR TO THE ADDITION OF PLASTICIZER. SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 318 AND ASTM C94IC94M OR MEASURING, MIXING, TRANSPORTING, ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE WITH THE ABOVE. REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): B. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER: 1-1/2" FOR #5 AND SMALLER 2" FOR #6 AND LARGER C. FOR CONCRETE NOT EXPOSED TO WEATHER 3/4" FOR SLABS, WALLS AND JOISTS 1-112" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS FASTENER SCHEDULE WINDOW AND DOOR BUCK FASTENERS FASTENER APPLICATION SIZE TYPE SPACING REMARKS APPLICATION SIZE TYPE SPACING REMARKS ix2 PT FURRING TO CASE HARDENED COIL 8" O/C GARAGE DOOR BUCK 1/4" DIA. TAPCON MASONRY 8 0/C 1 1/2" EMBED., 4" END DIST., MASONRY / CONC. NAIL 1 1/2" LONG. TO MASONRY/CONC. NO WASHER FASTENER 1 1/2" EDGE DIST. SGD, AL. EDOORS CASE HARDENED COIL 9" WINDOW/DOOR/ FASTENED GARAGE DOOR BUCK 3/8" DIA. OR " 0/C (3/" DIA) 1/2" DIA EXPANSION BOLT 4" EMBED., END DIST., RED INTO MASONRY/GONG 1x PT, SEEE NOTE 6 NAIL 1 1/2" LONG. STAGGERED TO MASONRY/GONG. 24 24" O/C (1/22" DIA) 3" EDGEE DIST. w/ WASHER WINDOWBUCK CASE HARDENED COIL 91,O/C WINDOW/DOOR/FASTENED METAL STRAP TO CONTACT THIS ENGINEER FOR SPACING 1x PT, SEE NOTE NAIL 11/2"LONG. STAGGERED INTO MASONRY/CONC. MASONRY/CONC. REQUIREMENTS EXT. SWING DOOR (2) 3/16"DIA TAPCON" 18" O/C 1 1/2" EMBED, 8" END. BUCK 2x PT, SEE NOTE 6 NO WASHER FASTNER DIST., 1 1/2" EDGE DIST. 2x PT WINDOW BUCK 0.138° PAF x 21/8" 9" 0/C 4" END. DIST, 1 1/2" PT TO STEEL COL., SEE W/ WASHER STAGGERED EDGE DIST. NOTE 6 NOTES 1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED 4. PAF SHALL BE HILT] X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE 6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. Ix MEMBERS ARE NAILED AND 2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 IIIIIM i' I SLJHDIV. 8t LOT: CREEKSIDE PHASE 2 LOT #101 PROJECT## 04321.201 101R1 MODEL: 4EHB "2605-HAYDEN" LSK IN ARAa G: EFT P PAGE: TAILS H EXFI C NOV ? 6 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE 102821 / ✓ SCALE: 1 /4" =1' — 0" SHEET TYR EXT. SHEATHING ATTACHMENT