HomeMy WebLinkAboutProduct Review AffidavitAddress! QoQLA 6DDj,�./�{7 �� Product Review Affidavit (White or Bronze aluminum) LOT # �) Product Approval Product Opening Design Product Rated Manufacturer Model # Glass Type Method of Attachment Number Pressure Design Pressure Opaque single door 1/4" concrete screw 6" edge distance @ head, 4" edge distance @ jamb, 4" each side of transom centerline to FL20461.17-RS with transom (+36) / (-47) (+47) / (-47) Therma-Tru Smooth Star N/A bucking. Tapcon spacing @ 15" o/c max. @ head and jamb. Min. embedment of all anchors to be 1 1/4" For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to F'� �,-J Y60) MI Window and achive a 1 1/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation FL17499.2-R8 SH Window (+ l i / (-60) 185 SH Non Impact details.For anchoring through frame into masonry / concrete use 3/16" tapcons with sufficient length to achive Doors a 11/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation details. For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to SH Window (Integral MI Window and achive a 13/8" minimum embed. Locate anchors as shown in installation details.For anchoring through frame FL15353.2-RS Mulled (+38) / (-48) (+48.1 / (-48.1) Doors 5764 Non Impact into masonry /concrete use 1/4" ELCO ultracon tapcons with sufficient length to achive a 1 1/4" minimum embed. w/ 1" min. edge distance. Locate anchors as shown in installation details. For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 1 1/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation FL15349.1-R14 Fixed Window +38 ( ) / (-48) +60 ( ) / (-60) MI Window and 185 PW Non Impact details.For anchoring through frame into masonry /concrete use 3/16" tapcons with sufficient length to achive Doors ail/4" minimum embed. Into substrate w/ min 21/2" edge distance. Locate anchors as shown in installation details. For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 13/8" minimum embed. Into substrate. Locate anchors as shown in elevations and installation FL15332.2-R6 SlidingMI Glass Door (+33 ) / (-41) (+48.2) / (-48.2) Window and Series 420 Non Impact details.For anchoring through frame into masonry/ concrete use 3/16" tapcons with sufficient length to achive Doors Aluminum SGD a 1 1/4" minimum embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors as shown in installation details. FL16107.3-1113 Double Garage Door (+29) / (-35) (+36) / (-42) Clopay 16.2x7 73 W6 N/A 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C 3/8" Simpson Titen heavy duty screw anchor with 1 1/8" OD washer into grout filled CMU with min. emben of FL8248.11-R20 Double Garage Door (+29) (-35) / (+34.4) / (-38.3) Wayne Dalton 8024 2 3/4", min. edge distance of 4" and min. end distance of 4". Max fastener spacing of 20". 3/8" dia. X 3" long (Alt) lag screws with 1" OD washers with a 19/32" thread penetration into seasoned dry wood supporting structure. Double Garage Door Series 170-175, 3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb and bracket location. 2 F1.14170.7-1314 (Alt) (+29) / (-35) (+34.4) / (-38.3) Overhead 177, 3/4" min edge distance. 180-185, 187 Use galvanized (zinc coated) roofing nails,11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, FL30310.1-R3 Roof IKO Cambridge - N/A approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is flush with, but not cutting into shingle surface. FL15216.1-R8 Underlayment Interwrap RhinoRoof U20 N/A Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 Y" annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the roll FL5259.1-R31 Underlayment (alt) Polyglass USA Polystick IRXE N/A Self adhesive FL17322.1-R7 Underlayment (alt) Atlas Roofing WeatherMaster N/A Self adhesive Corp 100 FL34546.1 Underlayment (alt) - - Owens Corning Shield Granulated N/A Self adhesive FL27076.16-R1 Underlayment (alt) APOC Weather Armor N/A Self adhesive SB-1 FL15272.1-R3 Soffit +31.6, -38.8 (+157) / (-46.1) PlyGem Veriform Install per manufacturers recommended requirements. FL15272.1-R3 Soffit (a It) +31.6, -38.8 (+75) / (-75) Alside T2 Install per manufacturers recommended requirements. F1.3792.5-1114 Off Ridge Vent Lomanco 770D N/A Install per manufacturers recommended requirements. FL19567.2-R2 Off Ridge Vent (alt) Millinium Metals MMI N/A Install per manufacturers recommended requirements. 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in concrete / masonry, 2 1/2" FL16293-R3 Hurricane Panels Less (+47) / (-53) Hurricane Storm 24 GAGE N/A min. edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. than 6' span panel MFG. 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in concrete / masonry, 2 1/2" FL16293-113 Hurricane Panels 6' (+45) / (-50) Hurricane Storm 24 GAGE N/A min. edge distance, 12" o/c max. spacing. Can be headed screw or all thread but with wing nuts. span or more panel MFG. FL17147.2-R5 Zip System Sheathing Huber Wall Sheathing N/A Install per manufacturers recommended requirements. FL13192.1-R6 Lap siding James Hardie Cemplank N/A Install per manufacturers recommended requirements. FL1392.1-R7 I I Joists (2 story only) Boise Cascade BCI N/A Install per manufacturers recommended requirements.