Loading...
HomeMy WebLinkAboutTruss Placement PlanA' .. W-0" .. 2l'-6" .. Products PlotID Net City Product Length Plies 11 9 16" BCI@ 4500s-1.8 18' 0" 1 J2 3 16" BCI@ 4500s-1.8 16' 0" 1 J3 10 16" BCI® 4500s-1.8 16'0" 1 J4 1 16" BCI@ 4500s-1.8 16' 0" 1 J5 1 16" BCIO 4500s-1.8 16' 0" 1 J6 3 16" BCI@ 4500s-1.8 4' 0" 1 J7 10 16" BCIO 6000s-1.8 21' 0" 1 J8 1 16" BCI® 6000s-1.8 20' 0" 1 J9 4 16" BCIO 6000s-1.8 20' 0" 1 BM1 2 1-3/4" x 16" VERSA-LAMO 2.0 3100 SP 20' 1 1/8" 2 Bk1 18 16" BCI@ 4500s-1.8 2' 0" 1 Bk2 4 16" BCI@ 4500s-1.8 1' 0" 1 Connector Summary PIotID Qty Manuf Product Skew Slope Hut 24 Simpson ITS1.81/16 Hu2 15 Simpson ITS2.37/16 - - Hu3 16 Simpson IUS1.81/16 STRONGBACKS REQUIRED DUE TO DEFLECTION DIFFERENTIAL (SEE STR13NGBACK LETTER IN ENG, PACK) FOR MAEMUO EBFECTVENESS. INSTALL STRONGBACKS BEFORE SHEETNG IS APPUED m TRUSSES H 5 PLUMB CU Reviewed for Co Compliance Universal Engineering g 12 ' Sciences REVIEWED pr Total Truss Quantity = 107. THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. 0 F- BY OTHERS GAP TYPICAL REFER TO EA PACK FOR CONNECTION. 12 D 1'-0 - 1�4 2'-0'. TYPICAL 7' SETBACK CORNERSET LABELING AND SPACING General Notes 1) All parallel chord trusses, flat trusses and flat girders have the top chord partially pointed green to be installed green side up. All hangers to be Simpson HUS26 unless otherwise 2) noted. All truss spacing is 24' O.C. unless otherwise 3) noted. Per Truss Plate Institute BCSI-Bl recommendation 4) permanent X-brocing should be placed at a maximum spacing 15' O.C. across the span, to be repeated at a maximum of 20' between each X-brace throughout the structure. Please refer to BCSI-81 for any additional bracing details. ROOF LOADING SCHEDULE TCLL = 20 PSF TCDL = 7 PSF BCLL = ' PSF BCDL = 10 PSF TOTAL = 9.2 PSF DURATION = 1.25 % WIND SPD/TYPE= 160 ENCLOSED BLDG EXPOSURE = C USAGE = RESIDENTIAL CAT II WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Tnus member design & conneaorplates are desiggnned for ASCE7-16 and maximmn forces &gym both oomponeDls and claddings and main wind force resisting systems. • These Trusses have been reviewed to tarty an. additional 1011 psf non-cancrmentbottom chord live load. FLOOR LOADING SCHEDUL TCLL = 40 PSF TCDL = 10 PSF BCDL = 5 PSF TOTAL = 55 PSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS OVER 5000$ AND UPLIFTS OVER 1000# ARE SHOWN ON ENGINEERING. WALL KEY eLOAD# DESCRIPTION INIT. DATE rLOAD# DESCRIPTION INIT. DATE RC. I I.— .1 z/2e/1B B1m BASE— LDB 7nD/zD R➢. Rm M., BL 4n2 a UNV & FURCH us V17/18 RKDI BALE LOAD L➢B 1i/20/20 RE01 BASE LOAD B1a VIVID RLN BASE LOAD LDB 12/t4/20 Rra1 BASE LOAD a/30/1B RF01 BASE LOAD LIB 1o/1248 So. BASE LOAD LOB 843/I9 RHCH BASE LOAD LOB Stuns MCI BASE LOAD GBV 01/23/20 RA1 BASE LOAD LDB 4117/2 - LOAD# DESCRIPTION INIT. DATE OV COPY 7BL RAN 160E roll 2/2B/1B CIA [HD DR➢ERS — B/16/18 OIB REV. RCS 1R. B/30/1H Cie RE—D CCKNECTOR INm LVL L➢B 10/12/IB CIC 1ES1CNrn PLR V/1-ALRT LOB B/13/19 Om REVS'➢ FACE KoUNT CNNCTRS L➢B 9/O/19 C1E REVISE➢ DANGERS GBV C1/23/20 01F CIIA220867 LBB 4/O/20 HANGER CHART dt,= HUS 26 (SIMPSON) \= HUS26-2 (SIMPSON) Labeled End Mark LE NOTE, no NOT CUT OR ALTER TRUSSES WITHOUT CD SENT OF THIS OFFICE. BACK CHARGES WILL NOT BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL BY OUR SERVICE DEPARTMENT AT CARPENTER CONTRACTORS OF AMA. INC. 877-293-9487 NOTE ALL BEARING WALLS NEED TO BE INSTALLED PRIOR TO SETTING TRUSSES LOAD# DESCRIPTION INIT. DATE RELABELED LDBI 7/111— Ota L. L➢B 11/20/2o am REv- RE'S L➢B 12/14/20 o1H REV 1. LABELS CBS 2/l1/2021 11H RELABLE —1 PFH 03USIVI1 0 CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE G. N.W. WINTER HAVEN FLORIDA 33680 PHONE: (800) 959-8806 FAX: (863) 294-2488 BUILDER DR HORTON—BREVARD CREEKSIDE EHB/ HAYDEN/ H FYJ/MODEL/ALT 7A5/320/4EHJH/01 (1-JOIST FLR SYSTEM) ALT DESC 10' X 8' COV. LAN. OTC LOT 64 BLOCK DESIGNER PAGE RAA 1 DATE 10 24 17 1 LAN 1. # 362326R LE 3 SA 16 "=1'