HomeMy WebLinkAboutCarport Installation PlanA J TABLE 1 BOW/RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS; AND POSTS OR GIRTS WIND ULTIMATE NOMINAL POST/ RAFTER . (INCHES) EXPOSURE WIND SPEED WIND: SPEED SPACING INTERIOR END CATEGORY MR1 (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 115 TO 150 89 TO 116 5.0 6 6 B C, r D 151 TO 180 117 TO 139 4.0 6 6 NOTES: 1. Specifications applicable to 26 gauge metal panels fastened directly to 12 or 14 gauge steel tube bow,frames. 2. Fasteners consist.of 1/4"-14X1"self-drilling screws with control seal washer. 3. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). Spacing requirements for other roof heightsand../or slopes may vary. APPROVED PRODUCTS LIST APPROVAL PRODUCT CATEGORY SUB CATEGORY MANUFACTURER No. & DATE STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL207:17.1 26 Gauge -AG Panel 10/13/16 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL20727.1 26 Gauge AG Panel 10/13/16 EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL179916.3 Series 402-14 09/07/15 EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1 Model 203 05/31 /15 WINDOWS SINGLE HUNG POCAHONTAS ALUMINUM COMPANY, INC. FL12940.2 Model 100 VS 01/06/16 METAL CARPORT INSTALLATION PLANS AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS FOR CONSTRUCTION IN THE STATE OF FLORIDA PREPARED FOR: CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 PREPARED BY.• BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 CONCRETE FOUNDATION DESIGN RECOMMENDATIONS: CONCRETE. SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF. 2500 PSI AT 28 DAYS. COVER OVER REINFORCING STEEL FOR FOUNDATIONS, MINIMUM CONCRETE COVER OVER REINFROCING BARS SHALL BE: 3 INCHES IN FOUNDATIONS WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH_ OR EXPOSED TO THE EARTH OR - WEATHER AND 1-1/2 INCHES ELSEWHERE. REINFORCING STEEL: THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. GALVANIZATION: METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO THE WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS; BOLTS AND NAILS EXPOSED DIRECTLY TO THE WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. -GENERAL NOTES: 1. THESE PLANS PERTAIN -ONLY TO THE STRUCTURE, INCLUDING MAIN WIND. FORCE RESISTING, SYSTEM, COMPONENTS AND CLADDING, AND BASE, RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. t 3. 4. 5. CONCEALED FASTENERS OR ATTACHME r• ; ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. THESE STRUCTURES ARE DESIGNED AS UTILITY/STORAGE BUILDINGS CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 1700 m ?e, ALL STEEL TUBING SHALL BE 50 KSI STEEL. ST. LUCIE COL..TY DL7LDLNG DIVISIO` FASTEN METAL ROOF AND WALL PANELS TO FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" O.C. AVERAGE. RE' VIEWED FOR COML,4u / REVIEWED BY ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. DATE 0 ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. PLANS Aft PER.IUT MUST BE KEPT O;N JOBOR NO INSPECTION WILL BE ltkDE. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST AND ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETF SLAR CONSTRUCTION- 8• CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9• POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE FIFTH EDITION (2014) (FBC FE 2014) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC FE 2014 - BUILDING. THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN: PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE,. FIFTH EDITION (2014): THE_PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. _"LtII)11111/��,, ;y�1 //llllll�� CAROLINA CARP BECHTOL ENGINEERING "^^ RR AND TESTINGMir, Ina. iasiamw GWMDW& 9WRONDirk AND VAWd&S hsmo PONMM �m�.mNm-wmn w.mms.� _TB r_S, INC. SHEET 1 OF 4 26 GA GALVANIZED METAL ROOF PANELS FASTENED TO RAFTER WITH #12-14 x 314' SDF's WITH CONTROL SEAL WASHER. (SEE TABLE 1 FOR FASTENER SPACING) 12 3 7"Q - 4 6 3 3 BOX EAVE OPTION U ' 1 5 3 SIDE EXTENSION 24' 16 GA ILCHANNEL BRACE ~ • FASTENED TO RAFTER WITH =U' (2)#12-14 x 3/4' SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) . INISH GRADE 1 B 3 MONOLITHIC SLAB FOUNDATION OR TOP OF H 4 CONCRETE o 1 2 f 3 CONTINUOUS CONCRETE SLAB (OPEN CARPORTS ONLY) .. 3 30'-0' MAX. RAFTER SPAN 3 ANCHORSNOT,REQUIREDWTTH TYPICAL BOW RAFTER SECTION . CONC-SLAB CONSTRUCE 3TION._ I EE DETAIL 1 OR 2\SHEQF.4). of TD Scale 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTER WITH , #12-14 x 3X SDF's WITH CONTROL SEAL WASHER 12 . (SEE TABLE.I FOR FASTENER SPACING) 3 45' y6' 4 3 E� ALL WEB \,*.WELD CONNECTIONS, ALL SIDES BOTH SIDES " ' 6 BOX EAVE OPTION 3 "5 SID.E.ExTENSION 3 FINISH GRADE 1 6 3. MONOLITHIC SLAB FOUNDATION OR TOP OF a CONCRETE 2 3 CONTINUOUS CONCRETE SLAB (OPEN CARPORTS ONLY) 3 0'-0' MAX. RAFTER SPAN 3 TRUSSED BOW. SECTION - - ANCHORS NOT REQUIRED WITH Not To Scale - CONCRETE SLAB CONSTRUCTION. (SEE:DETAIL 1 OR Z SHEET 3 OF 4) 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTER FRAME WITH #12-14x 314' Son WITH CONTROL SEAL WASHER (SEE TABLE 7, FOR FASTENER SPACING) �•; 5. 3 J 4 g 3. 3 BOX EAVE OPTION a LEAN-TO RAFTER SET 3 BELOW TOP OF LEG (BOW FRAME OR BOX EAVE) B . 9. MONOLITHIC SLAB FOUNDATION B b 4 3 2 4 2 CONTINUOUS CONCRETE SLAB N 3 (OPEN CARPORTS ONLY) _ 3 14'-0' MAX. SPA 30'-W MAXIMUM 3 RAFTER SPAN 3 ANCHORS NOT REQUIRED WITH CONCRETE SLAB CONSTRUCTION. (SEE DETAIL 1 OR Z SHEET 3 OF 4) TYPICAL SIDE/LEAN-TO EXTENTION SECTION Not To Scale (BOW FRAME LEAN-TO TO BOXE EAVE RAFTER) 6' TYP. -- DEPENDS ON NUMBER AND SPACING OF BOWS SEE TABLE 1 SHEET'IOF4 Ll OPTIONAL 26 GA R-PANEL SIDE OR END PANELS SEE TABLE 1. SHEET1OF4 SEE TABLE 1 SHEET 1OF4 26 G0. R-PANEL ROOFING SEE TABLE 1 SHEET IOF4 6' 6' s^ ANCHORS NOT B REQUIRED WITH GROUND ANCHORS aQ EACH END CONCRETE SLAB 2. SHEET OIL RAFTER POST AND EVERY OTHER. (SEEDETAIL10R 2, SHEEf30F 4) SIDE ELEVATION INTERIOR RAFTER POST LOCATION Not To Scale (SEE DETAIL 3, SHEET 3 OF 4) MAX f MAX I MAX I MAX OR SWINGING END WALL OPENING_ Not To Scale GABLED OPEN END WALL SECTION Not To Scale :E TABLE 1, SHEET 1 OF 4 TS HEADER 26 GA GALVANIZED METAL SIDE PANELS. SECURE WALL. PANELS TO RAFTER POSTS AND END POSTS_WRH #12-14 x 3/4' SELF-DRIL_UNG " SCREWS W/ CONTROL SEAL WASHER (SEE TABLE 1 FOR FASTENER SPACING) TS POST r GROUND POST g END POST LOCATIONS (SEE SHEET 3) ANCHORS NOT REQUIRED WITH CONCRETE SLAB CONSTRUCTION. (SEE DETAIL 1 OR 2. SHEET 3 OF 4) 26.GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTER WITH #12-14 x 3l4' SDFs WITH CONTROL SEAL WASHER (SEE TABLE 1 FOR FASTENER SPACING). 1, SHEET 1 OF 4 ALVANIZED / OOF PANELS BOX EAVE OPTION UVCIVILL LCMU IN VAKIt=A" DEPENDS ON NUMBER AND SPACING OF BOWS 4 2 4 OPENING FOR ROLL -UP OR SWINGING DOOR WRIT STRUCTURAL HEADER MA%IMUM CLEAR SPAN -lz-0v T_ 4 OPENING FOR SWINGING DOOR BETWEEN POSTS (N4nSh.Uni). _ s' a 6' E DOWN .ENGINEERING, 30' LONG WITH 5/8' ROD. AND DBL 4' HELIX EYE ANCHOR (SEE DETAIL 3. SHEET 3 OF 4) SIDE OPENINGS Not To Scale MAX I MAX I MAX I MAX I KM 'I MAX ANCHORS NOT REQUIRED WITH CONCRETE SLAB CONSTRUCTION. (SEE DETAIL t OR 2, SHEET 3OF 4) iEE TABLE I. SHEET 1 OF rZ6 GA. GALVANIZED METAL ROOF:PANELS ENDWALL POST 6 GA. GALVANIZED METAL SIDE PANELS ROUND ANCHORS @ EACH END 6 4 RAFTER POST AND EVERY OTHER 4 4 END POST LOCATION ANCHORS NOT REQUIRED WITH (SEE DETAIL 3 ON SHEET 3 OF 4) CONCRETE SLAB'CONSTRUCTION. (SEE DETAIL 10R 2, SHEET 30F 4) END WALL SECTION Not To Scale NOTE: 14 GA FRAMING IS 2-1/2" x 2-1/2' TUBE STEEL (TS). 12 GA FRAMING IS 2-1/4' x 2-1/4- TS. NIPPLES ARE 2-1/4' x 2-1/4' 14 GATS FOR 14 GA FRAMING. NIPPLES ARE Tx 2' 12 GA TS FOR 12 GA FRAMING. ✓1 BECHTOL Ely6BECHTOL 1D�� G, INCG, INC. a 605 WEST 9 MONOLITHIC SLAB FOUNDATION B 2 4 3 CONTINUOUS CONCRETE SLAB (OPEN CARPORTS ONLY) 14'-0- MAX. SPA ANCHORS NOT REQUIRED WITH CONCRETE SLAB CONSTRUCTION. (SEE DETAIL 1.OR Z SHEET 3 OF 4) "x 30' WITH DBL 4' HELIX WITHIN B' OF EACH RAFTER WITH EXTENSIONS (SEE DETAIL 3, SHEET 3 OF 4) TYPICAL FREESTANDING LEAN-TO Not To Scale DELAND, FLO}iID Zd p • • • • Certificate • bn 2 Afk -�-�s' Thomas !I♦jt�l • 1 FloridaFlorida L�. 38538 j 138538 � 7f STATE Op •: ��/v S•••'��ORIDR II CAROLINA CARPORTS, INC. AV BECHTOL ENGINEERING s AND TESTING, ilia —V ;.B : 170Q1 NX)NSDLTIN GWTM 1r WARa WINrA4 AW WTOMS TOM EWNMM `°Na00°°'°� APflOF�TB. 'SHEET 2OF4 i v q II a "x MINIMUM 5" EXPANSION ANCHOR SASE RAIL WITHIN 6" OF EACH W POSTS ALONG SIDES OR INSIDE ER END WALL POST ALONG END IONS IINIMUM MINIMUM 2-1/2" EMBEDMENT MONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 #5's CONTINUOUS — INSTALL 1/2"x MINIMUM 5" EXPANSION ANCHOR THROUGH BASE RAIL WITHIN.6" OF EACH 24" 16 GA U-CHANNEL BRACE (5.' TO 7' POST) RAFTER POST ALONG SIDES AND INSIDE TS BOW RAFTER 48' 16 GA U-CHANNEL BRACE (8' TO 14' POST) EVERY OTHER END: WALL POST ALONG END BRACE ANGLE SHALL BE MIN. 45' WALL SECTIONS NO SCREWS TO MAX. 60" FROM HORIZONTAL REQUIRED MIN. 6" IN BOW BEND 5" - NIPPLE TO 3/16" RAFTER MINIMUM 2-1/2" EMBEDMENT 416 GA U-CHANNEL BRACE (V TO 7' POST) 48' 16 GA U-CHANNEL BRACE (V TO 14' POST) 0-1 /2" 1/2• BRACE ANGLE SHALL BE MIN. 45• - I TO MAX. 60• FROM HORIZONTAL / MINIMUM 4"J 6" . 3' 3• 6" LONG TS NIPPLE SECURE RAFTER AND POST TO CONTINUOUS 4" CONCRETE PAVEMENT NIPPLE WITH (4) #12-14 x 3/4" TS RAFTER POST SELF -DRILLING FASTENERS TS RAFTER 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 z 3/4" SDF's RAFTER POST CONCRETE BASE RAIL ANCHORAGE 2 CONCRETE BASE RAIL ANCHORAGE BOW RAFTER/POST DETAIL . �� BOX,EAVE RAFTER/P.OST DETAIL t Not To Scat (OPTIONAL - OPEN CARPORTS ONLY) L Not To Scale (OPTIONAL) `• �� Not To Sple NtTtale DRILL 5/8" HOLE THROUGH THE 2" AWASHERS BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2" DIAMETER �TS CONTINUOUS THROUGH -BOLT BASE RAIL DRILL 5/8 HOLE THROUGH THE : . BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2° DIAMETER THROUGH43OLT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE\ 2"WASHERS \ TS CONTINUOUS BASE RAIL I I EYE ANCHOR U MINIMUM 4° U 518".ROD 30' LONG WITH DBL 4" HELIX CONTINUOUS 4" CONCRETE PAVEMENT EYE ANCHOR 5/8" ROD 30" LONG WITH DBL4"HELD( BASE RAIL ANC 3 Not To Scale ALTERNATE CONCRETE BASE RAIL ANCHORAGE Not To Scale (WHERE SLAB IS TOO NARROW TO USE CONCRETE EXPANSION ANCHOR BOLTS) TS RAFTER POST, 2"x4" 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDPs, 2 ON POST, 2 ON RAFTER - TS LEAN-TO RAFTER \ �\ GAF FOR \• � 14 GA FRAMING 2"x2"x2" 16 GA ANGLE CLIP 16 GAUGE U-CHANNEL BRACE SECURE TO POST AND FASTENED TO THE POST AND RAFTER WITH (Al) #12-14 x 3/4" RAFTER WITH (2) #12-14 x 3/4" SDF'S SDF's, 2 ON RAFTER, AT EACH END (4 PER BRACE) — 2 ON POST BRACE SECTION POST / LEAN-TO RAFTER CONN. DETAIL Not To Scale 0 Not To Scale NIPPLE TO \ 3/16" RAFTER . / 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12A4 x 3/4" SDF-s, 24" 16 GA U-CHANNEL BRACE (V TO 7' POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60" FROM HORIZONTAL 6" LONG TS NIPPLE SECURE WITH (4)'#12-14 x 3/4" SDFs RAFTER POST SIDE EXTENSION �� RAFTER/POST DETAIL � Not To Scale 1-1/2.18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. . GA. METAL ROOF PANEL TS RAFTER ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale 1-1/2" x 1-1/2" x 2".16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 314" SDFs 2 ON TOP, 2 ON SIDE TS RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND. GABLE RAIL WITH (4) *12-14 x 3)4" SDFs, 2 ON TOP, 2 ON BOTTOM TS GABLE RAIL GABLE RAIL TO RAFTER :POST &2�tNECTION DETAIL NOTE: 14 GA FRAMING IS 2-1/2" x 2-1/2" TUBE STEEL (TS). 12 GA FRAMING IS 2-1/4" is 2-1/4- TS. NIPPLES ARE 2-1/4' x 2-1/4" 14 GA TS FOR 14 GA FRAMING. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING. •. fi to •.••,� ArE p /1�0 ' • A'••. NIPPLE TO DBL. HDR. RAFTER POST 5 NIPPLE ACH WITH ' LONG TS NIPPLE c 3/4' 1/6- SECURE WITH (4) #12-14 x 3/4' LING FASTENERS SELF -DRILLING FASTENERS POST RAFTER POST/DBL. HEADER DETAIL Not To Scale 2'x2"x2" 16 GA ANGLE CLIP SECURE TO. POST AND RAFTER WITH (4) #12-14 x 3/4' SDF's, (2) ON BOTTOM, (2).0N SIDE END POST 5 END POST/RAFTER CONN. DETAIL Not To Scale #12-14 x 3/4" SDF @ 12" O.C. 3A. ROLL -UP DOOR GUIDE TO POST CONNECTION DETAIL Not To Scale CURTAIN: 26 GA. galvanized steel with baked on epoxy primer & polyester top coat LE TS HEADER NIPPLE TO DBL. HDR. 2 RAFTER POST/HEADER DETAIL Not To Scale TS RAFTER POST - "x 1-1/2'x2'16 GACLIP LE SECURE TO T AND BASE RAIL 1 (4) #12-14 x 3/4" SDFs; N TOP, (2) ON SIDE ITS CONTINUOUS BASE RAIL 6 END POST/BASE .RAIL CONN. Not To Scale POST TS NONSTRUCTURAL HEADER I I SWINGING DOOR I I (Size varies, see plan) II I II I II I II I II II Q I TS POST II 6" LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4- SELF-DRILLING. FASTENERS - /_TS POST TS CONTINUOUS BASE RAIL 3/16' NIPPLE TO BASE RAIL RAFTER POST/BASE B�tTo�S!cale_ RAIL CONNECTION DETAIL TS POST c 2' 16 GA ANGLE CLIP E TO POST AND TOP OF R, OR BOTTOM.OF WINDOW RT WITH (4) #'12-14 x 9 4" SDF's TOP OR BOTTOM, (2) ON SIDE TS NON-STRUCTURAL HEADER TS WINDOW RAIL (OR GIRT FOR VERTICAL SIDING OPTION) NON-STRUCTURAL HEADER, WINDOW r1 RAIL, OR GIRT TO POST CONN. DETAIL Not To Scale TE O A SECTION Not To Scale #12-14 x 3/4" SDF @ 12" O.C. TS TRUSSED RAFTER CHORD, J OR NONSTRUCTURAL HEADER TS END POST OR DOOR/ WINDOW FRAME POST Al 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST (EACH SIDE) TS BASEIWINDOW RAIL OR AND RAFTER CHORDIRAIL WITH NONSTRUCTURAL HEADER (4)1/4'x1' SDF's, (2) ON TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR 4 NON-STRUCTURAL HEADER CONK DETAIL Not To Scale NIPPLE TO BASE RAIL 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x3/4" SDF's TS RAFTER POST CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL Not To Scale NOTE: 14 GA FRAMING IS 2-1/2" x 2-1/Y TUBE STEEL (m). 12 GA FRAMING IS 2-1/4" x 2AW TS. NIPPLES ARE 2-1/4' x 2-1/4' 14 GA TS FOR. 14 GA FRAMING. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING. EXTERIOR b �'• STATE OF . �� ���iC�COR10P.••i_ SSIiIAI A1.�G� C