HomeMy WebLinkAboutBlower Door TestDate: 04 /16 tt 8 Contractor: Job Address: Construction: & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 , Fax 772-462-6443 - FSVENERGY CONSERVATION CODE R402.4.1.2 House Infiltration Test (Blower Door) Certification Prescriptive and Performance Method Permit #: i 7 C)G" 035 7 ew Construction — Complete House Infiltration Test Results CFM (50) = ZQ Volume = k �_ 1 _ 5 ACH (50) = CFM (56) x 60 / Volume = Passing results must be & ACH (50) or less �__►- 3'- 4s ( ) Existing —After Addition SLC Climate Zone 2 Test Date: -• L f 1 g Mech ica/ Ventilation required less than 3 ACH ( Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company _ (�� O D u � �� Jl / Company Name: ec_ Address: 1 7 IL''��( � �� ��C I e 'l I hereby certify that the above House Infiltratii results demonstrate compliance with FBC Energy Conservation requirements in ccorda ce with Sectign-R402.4.1.2 Climate Zone 2. Signature: Printed Name: Lice n se/Ce rtific Date: 4 LA It 16 145 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Permit #: 170& — `2 5 / Lot #: Contractor: Address: Construction: most Construction Test ❑ Rough -in Test 31 l2'->ws-rv� Ct I-, 4� '11�, �L 3""5 Test Conditions: n Date: �� ` 1S - 20l1 Floor Area (ft2): ' �Zy Time: 10 `. 3 awl Primary Location of Supply Ductwork Act" G Indoor Temperature (F): -72 ° Primary Location of Return Ductwork Outdoor Temperature (F): -7 4 Total Leakage Test (Outside) Duct Leakage: ❑ D ault all-m-P. Leak Free ❑ Proposed On = Test Pressure: r (Pa) Baseline Duct Pressure (optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: 2rfass ❑ Fail Installe Pa A. Al .6 .5 5L . Total Leakage (cfm): a Total Leakage per 100 sgft: 2- + CFM25 x 100 divided by the CFA = Duct Leakage CFM1100 sqft. Testing Company �p Company Name: �I L_(2_ Address: 9 ' ` G,%O `�--G �1 ��V l' e� F_L I hereby certify a above Duct Sealing Leakage results demonstrate compliance with 5'h Edition FBC Energy Conservation requirements in accordance with Section R 2. Signature: Printed Name: 6S\-,_)0 License/Certificate #: