HomeMy WebLinkAboutProduct Approval,.' .
Florida Building Code Online
Page: 1 of 2
is
eas Home J Lop In I User Regmntlon • t(ail?pl I submit surcharge I stati 8 ogts, Publlotionss ' 'ets site nap I Chia l Search f
M Produet Approval
USER: Puhllt User
r or
1'tadrxt Aooroval Menu > Prod�nYer Aoolicatlnn .n-h > Aoolica Inn kt > Application Detail .
e FL # fL17147 Rl .
Application Type'Revision
Code Verslb'0 2014
Application Status " Approved
Comments
Archlved. 0
Product Manufacturer Huber. Engineered Woods LLC
Address/Phone%Email 10925 David Taylor Drive ,
Sulte:300
Charlotte, NC 28262
(704) S48-5442' '
kurt.koch@hubeccom
Authorized Signature Kurt Koch
kurt•koch@huber•com
Technical Representative Ken W. 1-fix
Address/Phone/Email 1446.Mwy 334
Commerce, GA 30530
(706) 336-3041.
ken.hix@huber.com
Quality Assurance Representative
Walker Campbell
Address/Phone/Email' " 1446 Hwy 334
Commerce, GA 30530
(704) 562-1053.
walker.cam pbeil@huber.com
Category Structural Components
Subcategory Products Introduced as a Result:of New Technology
Compliance Method Evaluation Report from a Product EvaluationEntity
Evaluation Entity ICC Evaluation Service,'LLC
Quality Assurance Entity ICC Evaluation Service
QualityAssurance Contract Expiration Date 10/01/2017 .
Velldeted. ey ICC Evaluatlon Service, LLC.
Certifipte of Independence EL17147' R1 Col. r rtln are of Ind pendence for Evaluation.odf
Referenced Standard and "Year (of Standard) Standard
Year.
ICC-Evaluatlon Service AC310 2015"
Equlvalence of Product Standards
Certified Sy
Approved'Evaluaiion Entity
EL17147 RI Ea riv A atn pd
Sectlons'from; the Code
Ne
https://www.floridabuildin :or r/ r a dtl.aS x? aram=wGEVX wtD vCo3EapiIlBd.:. 4/12/2017
g �P p PP_ P P Q g
Florida BuildingP
Code Online
..
of 2
. age:2
Product Approval Method' "
Method 1 Option C
Date Submitted
' OB/31j2015 .
Date. Valldate.d
09/16/2015 :'
DatePending FB
.0 A PProval
Date Approved ... 09j20/2015 . • ..
Suinma of Products
Model, Number or Name Desertpdon,
17147.1 ZIP System (R) Wall She ' ZIP System (R) Wall Sheathing
Umits of use
'Approved.6r use in HVHZ: No Instaation InstrueNons . .
•Approved for use outside HVHZ; Ye$ md-fitrild
R3 II 7iP Sneathlna inc�Impact3tesistant: No y: ICC Evaluation Service :LLC
Design Pressure: N/A y Ipdependent Third Pa
Evaluation Re
rtyj
Other: limited to structural as ects of panel �� P p EL17147 RI AF F,$$_1474 f21 Ddf
' • F1.17147 RSA SR1474 Ddf
.. Bads Next' .
COa17i GL�S,::'Z601 malr Sn nr seed T:i°^ha �'n-„d,:., Phone' � .. . .
"-0 -
The sate of norlda Is an AA/Mo employer. roovrtehe 7a°7.701? ire of Flnrlta: ;; Pdfma smtnm.n rv'ctaea -- _ ant
Under Florida law, email addresses are Public records. if You do not want your e-mail address refeased 1n'rus ' response mra public -records requewt, do net send
ction 5 mall to this sntlty. instead, -'-
section the office by phone or by tra'd tional mall. I! p
Section 455.275 1 ; Florlda. tubes,zed you have any quesdarw, please cont7ct 950.497.1395; *Pursuant to
. they have one. The emalls Provided may beeused!oroffiWi1ca licensees:
b on wlDl the Ocenseunder e 1ar 4S5cr e5, r Iuaddreroviidae are pub r r ent with a do rroaddress t wish tpM.
wI!ppN a personal address, please provide the Department with an email address which tan'be made available to the Public. To detememin.H you area Ilo t w is under
Chapter 455, F.5„ Please dick �•
Product Approval Accepts: .
®®®®
Credit Card:
Safe . :.
Q
https://www:floridabuilding:org/pr/pr apt) dt1.aspx?pararii=wGEVX wtDq_vCo3EapiIlBd..: 4%12%2017
ZIP System® Roof & Wall Sheathing
INSTALLATION MANUAL
Z�A system
. .. :.
_ noova w,ucsBe�nrrnra
CoMentS
FASTER. TIGHTER. ENERGY EFFICIENT.
02 ZIP System® Sheathing Installation: On Roofs
: 08 ZIP System® Roof. &Wall Sheathing:: Win dow
03 :ZIP System"' Tape. Installation -
installation Flanged Windows'&.Brick Mould Windows
Roof Panel. Seams
09 ZIP System® Roof & Wall Sheathing ", Window
.04 .ZIP SysteW' Tape. Installation =
Installation. Mould Windows (continued)
Roof Panel Seams:(continued
- )
10 •ZIP Systems Roof & Wall Sheathing -
05 Roof Coveting Installation Instructions
Penetration Openings
06. ZIP Systems Roof & Wall Sheathing Installation
11 ZIP Systems &Wall Sheathing
Installation Details
07 ZIP System" Tape lnstallation = Panel Seams
12 Zip System® Roof. &Wall Sheathing;
.installation Details (continued)
ATTENTION: This installation guide is•interided, to provide general
Information -for: designer and end user.: The following
ZIP. System Roof & Wall sheathing can be used with a range of exterior
r
guidelines:
will help you safely and properly install the ZIP System• Roof & Wall
wall sheathing. We urge you,and anyone installing
claddings and roof coverings.. Approved wall coverings include brick,
'vinyl, stone, wood fiber cement, wood and cedar shake's,'traditional hard
this product, to
read these guidelines to order to minimize any risk of safety hazards
coat stucco and specified drainabla EIFS applications, however it: is .
not recommended for
and to prevent voiding any applicable warranties. This manual is
a general Instaftotion guide and does.
,use with adhesively attached EIFS. Approved roof
covedngs include asphalt -fiberglass shingles, rrietal tiles and panels, day and
not cover every Installation..
condition. Proper installation shall 'be deemed to mean' 'the most
restrictive: requirement specified
concrete tiles, slate and slate -type shingles and wood shakes and shingles.
Follow ail cladding and root covering manufacturer's installation instructions.
by Huber Engineered Woods (fit -Ili),
local building code, engineer 'or architect. of. record. or other authority .
having jurisdiction.; You are fully and solely
. ZIP. System Roof &; Wall she 'can be used on buildings of Type
responsible for all safety
requirements:arfd'cdde compliance. For additional information contact
lit (Roof Applications ONLY) and Type V constriction and construction
permitted under the IRC:
Huber Engineered Woods LLC:
.
ZIP System• Roof & Wall Sheathing Safety Guidelines
- Follow all OSHA regulations and any other
ZIP System* Roof &Wall Sheathing includes:
ZIP
- System sheathing panels with built-in moisture barrier with preprinted
Safety guidelines and safety
practices during installation and construction:
fastening and tape guides
- Use approvedsatetybettsand/orham essasorotherfallprotectionequipment
;ZIP System tape
- Install ZIP System panels and tape only in dry conditions and on dry: surfaces.
Do
Storage and Handling
not install in.ratn, snow; frost or otherslippery conditions.
- Wear rubber -soled or other high -traction footwear while:installing ZIP System
Set paneistack on three supports (stickers) to keep off.the9round:
Outdoors, cover panels,loosely. with waterproof protective
sheathing in a root application. Do not wearfooiweai with wom soles or heels.
Ensure .the roofing surface Is tree fro* ''oil, chemicals, cools,
material.
Anchor covers on top of the stack, but keep away from sides and bottom
to assure good circulation:
sawdust, dirt;
electric cords, air hoses, clothing and anything else that r0ght: create a
�ppin9 hazard.
air
In high moisfure,envlronments, cut, banding on the panel stack to prevent
- Install temporarytoe:boards along the ZIP System sheathing roof surface:
edge damage:
Zip System* Roof &Walt Sheathing Notes and Limitations::
What Is ZIP System• Roof & WaILSheathing?
= Do not use. on roofs with slopes less than2/M
ZIP System Roof &Wall sheathing.is code recognized as a wood 'structural
panel, roofing undedayrr(ent (ICC-ES ESP-100);
- Do not use abutted against general stone or masonry without pnviding:a
minimum of gap. .
water -resistive barrier
and air barrier. (ICC-Es ESR-1474). ZIP System Roof & Wall sheathin
l ZI1/2"P
Do not install ZIP System .tape in temperatures less Than 20°: F
has a _built-ln moisture bamer• that lets You sly g
y y good-bye: to building paper
or hou,'iaps on the walls and.felt paper an the
ZIP System products are not recommended for manufactured housing
applications that are built under a federal building code administered by
roof.• Simply install the
panels, taps the seams, and you.have a structural wall sheathing; Water:
the U,S.:Departriment of Housing and Urban.Development (HUD),
resistive barrier and, air barrier or a structural roof sheathing and roofing
undedayment all from one product.
Do.not use panel edge clips (H-Clips) W!.WZIP System Roof & Wall sheathing'
Without expressed Written approval from Huber Engineered. Woods."
Do not use ZIP System -tape to permanently seat around circular roof
projections (plumbing vents, pipe's, curved walls, etc.)
Contents (continued)
Wall coverings:
ZIP System Roof & Wall_ sheathing :should be covered with the finished
roof. covering or exterior cladding within ISO days of installation.
Finished roof and exterior cladding products should be installed per
the manutacturer's.fristaliation instructions,
Per the recommendation of the Western Red. Ceder Lumber Association
and tFle.U.S. Forest Products Laboratory, wood siding should be primed
before installation.
= When original roofing or claddings are removed and replaced an existing ZIP
System sheathing,' the roof or wall should tie coveted with an additional
roofing.underlayment or water resistive barrier prior to installation of the
.new finished roofing or cladding.
Note: In cladding systems requiring multiple layers of water -resistive barriers,
like traditional hard -coat stucco, ZIP System efreathirig Is intended Doty to:
replace the first layer.
Wet Blown Cellulose trieuIWdn
In addition to following manufacturer installation Instructions, we recommend.
a maximum moisture content of the cellulose of less than 25% measured at
the inside surface of the ZIP System panel before closing the wall cavity.
Secondary. Coatings
Do not apply secondary coatings or treatments*to ZIP System Roof fl, Wall
sheafhingpanels:with the exception of the following:
HEW approved fire resistant: coatings. Fire resistant coatings must be
tested and approved by-HEW:for use with ZIP System panels.
Field applied water solUbfe borate insecticide or fungicide. treatments
applied:to the non overlay side .of the panel. See technical tip, "Tell' ite
Treatmentson ZIP System Roof & Wall Sheathing." on zlpsystem:com for
more Information.
Permeable laminated radiant' barrier foil or -paint For a radiant barrier foil or
coating to be considered permeable, it must have an applied perneance of
five perms or greater as tested by.the:ASTM E 96 wet cup standard. Fora
radiant foil, the permeance evaluation would include any adhesive and/or
backer used to laminate a -foil: For a radiant pairit/coatirig, the perrneance
evaluation should be conducted at the applied thickness of the pafnUcoating.
ZIP System Roof and Wati shaath'otg replaces aNy the 8rstiayerin.multLundedaymentsystems
Edge support is not required by code with 112 (32/i6 span rated)'and 5M (4WO span rated) performance category sheathing if the (ram ng does ncl exceed 24' c.c.
and the. total Wad does not exceed 93 list for 1/2 and 156 psf for 5M performance dategodes. This is based on U180 deflecilon cr texts Iw total load.
ZIP -System? Hoof & Wall Sheathing installation Manual
02
ZIPS— stem® Sheathing.lnstallation on Roofs
Overview: ZIP System Roof &Wall sheathing is composed of ZIP System. panels and ZIP System sear,
panels should be f: sealing tape. ZIP System° Roof B Wall Sheathingfully installed before . the seam sealing tape Is applied; In
the ZIP
generl;
on the roof to the highest It is at the iliscretian of the installer whether to apply tape from the
System roof sheathing panels should be installed from the lowest point.
down
sections of. the roof and working down will minimize foot.traffic'on the tape. The following'
top or from the bottom up.; However, working from'the:hlgliest
Installation steps
are.presented as g6ldelines.and s general outline of
the installation prgce$9. These are manufacturer Installation recommendations -please visit zipsystem.com for a.library of flashing and'tnstallation details. You are
fully and solely responsible for all safety requirements: Good
construction and s' afety_ practices should be followed et all times.
1::
-
[Step
Ensure that the panel surface is•dry and clean of any'nails; sawdust, or
other debris.Or protrusions prior to installing of walking on the panels.
After ensuring -compliance with all OSHA and, local code safety
guidelines, install ZIP System sheathing panels with the moisture
barrier surface facing outside.:The long edge (81) should be oriented
perpendiculavto the framing members, and panels should be installed
with the 4' edge; seams staggered a minlmum of 24'.
1/8' spacing between square edges of all adjacent panels is recommended,
in accordance with industry standards for wood sheathing: (Tongue &
Groove panels are designed. to. self -space and do not require manual
V Panel Edges 4' Panel Edges
spacing on the e1'edges.)
US. ifir
.
The unique edge prole is Maintain 1/6' space
designed to accommodate. where V edges:mee:.
Incremental panel Unique edge profile is on
expansion'and does not V adges only.
iequire Manuel gapping
along ifie W edges,
ep
ure that ZIP System panels span at least three framing members and
FSWAZ
aming member supports the entireW edge of the panels.
ten the'ZIPSystem Roof & Wekl'sheathing panel to the framing
b
Members with code approved. fasteners spaced' at the appropriate
edge and intermediate spacin6.-It is the responsibility of the.general
contractor to verify proper fastener type and spacing prior to installation.
- Apply the fasteners 3/8' from the panel ends and. comers.
- An ideal installation would be. where fastener heads are flush with the
panel surface. However, due to variations in materials anal limitations
on equipment, this may be difficult to achieve in some situations. It
Is not required to tape over overdriven fasteners unless the fastener
head creates a hole through the entire panel.ihickness. Please see::
the.techNcaitip; "Overdriven. Fasteners in ZIP System Root and Wall
Sheathing," for more information.
step 3.
Install temporary toe boards as necessary,wheri'applying the ZIP System
sheathing panels up, the slope of the roof planes.:
03.
ZIP System" Tape. installation - Roof'.Panel Seams
APPIY ZIP System Pape utter all ZIP System Roof & Wall sheathing panels, are fully fastened to roof -framing members. only ZIP System tape should be used to
seal the seams of ZIP System panels. Ensure that the panel surfaces are dry and free of any nails; sawdust and other debris, or protrusions. Avoid stepping.
an; tape in high temperature environments. ZIP System tape: is'a contact tape that requires pressure for an adequate seat:
r
p 1.
Apply ZIP System tape.to every vertical andh6iliontai panel seam. It is
t the discretion of the Installer whether to apply tapefrom the top down
r from the bottom up. However; *oNng.from,the highest sections of
he roof and working down will minimize foot traffic on the tape.
Ensure that the tape is centered over these'am within +/-112" to provide
adequate coverage and to ensure that wrinkles in the tape are minimized.
- Ensure that tape lengths are continuous across the B' horizontal edge
of the panels. I} splices are unavoidable, create an overlapping splice
of at least 3. Apply moderate pressure onto the surface of the tape, to:
ensure a secure'bbnd between. the panel and'the tape.
Use ZIP System tape gyn. gr tape:roller to apply pressure to the tape
and smooth out any.wrinkles:
Take special,car'e to remove any voids.andlor trapped air at splice .
areas and F4oints.
Step 2
For valley areas of framing, we recommend you use 6° wide ZIP System
tape. This tape is wider than panel seam tape and Is designed to give you
optimal protection in valley areas.
Starting from the bottom and working your way up; apply one continuous .
Piece of 6' tape so that the center of the tape is over the valley seam. ,
Use the tape gun or tape roller to apply pressure to the tape to ensure
proper contact with the panel and to eliminate any wrinkles that might
have occurred in the tape. Take special care to seat tape completely
into the valley.
Note:
-. It Is. Important to pay.extra attention to valley taping, as water is
directed toward the valleys during rain events.,
Self -adhering ice, and water barriers, may be required by code. ZIP .:
System tape is not considered a replicemetii.for self -adhering ice
and water barriers. Therefore; when self•adhering ice and water
barriers are required, they should be Installed in addition to ZIP
System tape
Step 3.
..
N 6' ZIP System tape is not available, use two continuous pieces.of 3.75'
ZIP System panel seam tape over the entire length of the valley seam,
overlapping.the places on the valley seam by at least 1 ".
Starting from the bottom, Install the first piece of; tape overlapping the . .
valley seam' by atleast 1'... -
F
- Use the tape gun or tape roller to apply pressure to.the.tape to ensure
proper contact with the panel and to eliminate any wrinkles that might
have occurred In the tape.
Apply the second piece of tape, overlapping the first piece in the valley..
... I
seam: by 1'.
Repeat use of the tape gun or roller to make sure the tape•is adequately
adhered and Vghtiy pressed into the valley seam.
Note:
It is important to pay extra 'attention to valley taping as water i-a
directed toward the valleys during rain events.
- Self -adhering too and water barriers may -be requlredby node. ZIP
System tape is:not considered a replacement for self-adhering.ice.
and water barriers. Therefore, when self -adhering ice and water
barriers are required; they. should be installed in addition to ZIP r overlap
System tape.
To. provide temporary weather protection to roofMali intersections
of dormers or'other wood -sheathed projections, apply 2" of the tape
width up: vertical projection from where it intersects with the roof.
The remaining tape 'wldth can.be adhered to the ZIP System roof
sheathing panels.
Use the tape. gun or tape roller to apply pressure to the tape and smooth
out any wrinkles;
to 5.
Install ZIP System tape over hips and ridges by centering the tape over::
the peak seam: Apply tape in sufficient length to completely extend the
fengih of the hip or ddge.
Starting from.the lowest point of the hip and working up, press tape Into
place keeping tape centered over the hip. Apply moderate pressure oil
onto the surface of.ttie tape to ensure a secure:bond between the panel
and ilia tape.
-: Cut ridge tape as required for, ventilation prior to installing ridge Vent.
Step 6: .
Tape
toe board nail holes: once the toe boards are removed, working
from the highest toe boards to the lowest.
Second piece
of tape
05
Roof, Covering Installation Instructions . .
ZIP System Root: & Illfall sheathing is a code recognized sheathing and underlayment and is approved for: use.with the following root coverings:
Asphalt -fiberglass Shingles
- .Metal Roofs (shingles and panels)
—Clay Tile
- Concrete Tile
- Slate and Slate -type Shingles
Wood Shingles
- Wood'Shakes
tlVhen installing roof coverings, tallow applicable codes and mariutacturers.suggested- Instructions. Some roof coverings require a slip-sheet.in addition to
convenfional underiaytnenL Where slip -sheets are:required, they should be Installed over ZIP System sheathing panels.
Note:. Visit zipsystem:com for.updates.and installation details.
Asphalt -fiberglass Shingles
Apply asphalt shingles directly to ZIP'System sheathing: For roofs with a.slope of.2/12 or greater but less than 4/12,, additional undedayment:may be required.
Install asphalt -fiberglass 'shingles according to applicable codes and manufacturers (nstallafion instructions.
Metal Roof Coverings
Metal roof coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installatlon Instructions and appiicable
codes are followed.•
Fasteners used to; secure the ZIP System Roof'& Will sheathing panels to.supporting framing must be compatible with the specific metal roof covering
used.. Galvanized fasteners shotl be used with galvanized roof coverings' aluminum -zinc coated fasteners shall be used with aluminum -fine coated roof
coverings and 300 series stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types.
In addition, metal roof flashing shall also be made of a material compatible with the speaiffc metal roof covering used. Apply slopes of 3/12 ometal shingles on roofs with
rgreater.
Clay and Conceete Tile Roof Coverings
Z1P System Roof & Wail sheathing, is Intended to replace the first Layer in a two -layer or multi -layer underlayment system. 'When installing clay: or
concrete tile roof coverings, follow the installation. recommendations of FRSA/TRI.0732b Install file roofs according to applicable codes and manufacturer's
installation instructions. .
Slate and Slate-typethingles
Apply slate and slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to -applicable codes and manufacturers
installation instructions.
Wood Shingles
ZIP System- Roof'& Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of underlayment
may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater.: Install 'wood shingles according :to
applicable codes and manutacture-es.installation instructions.
Wood Shakes
ZIP System Roof&: Wall sheathing is intended toreplace the first layer of underlayment required by the IBC and/or the IRC. Additional layers of underlayment
may be required by code depending on the local climate. ZiP System roof sheathing is not to be construed as a replacement for interlayment. Apply wood
;shakes on roofs with slopes 'of 4/12 or'greater. Install wood shakes according to applicable codes and manufacturer's installation instructions.
ZIP System' Roof & Wall Sheathing Installation Manual
06
ZIP System® Sheathing Installation on. Walls
Overview: ZIP.System Roof &Wall sheathing is composed of ZIP System'patiels and ZIP System seani:sealing tape. ZIP System® Roof' & Wall Sheathing
panels should tie fully installed before the seats sealing tape- is applied. The following. installation steps are presented as a general outline of the installation
process::These are manufacturer installation recommendations _ please visit zipsystem.com •ftsr a library r presented Installation details. You are sully and'
solely responsible for all safety requirements. Good construction and safetypractices should.be: followed at all times: .
Step1. Install ZIP. System Roof & Will Sheathing. panels, positioned
with the water-resistlyp barrier facing outside: Ths.panels may
be Installed with: the long :side of the panel oriented: either
horizontally-or.vertically to the framing members. Walls that are'
designed to resist lateral shear forces :and sheathed with wood..
str]ctural Panels typically require solid framing or blocking. behind
all panel edges. _If oriented horizontally, block horizontal joints if
wall is designed for bracing or as a shear wall. .. .
1/8' sPebing between square edges of -all adjacent panels is
recommended -in accordance with industry standards for wood
Sheathing installation.
8 P Edges 4, Pa
V and V
' anetEd Pane{Ed Edges
9 nelEdgee
VW
71
The unique edge profile is Maintain 1/8• space Wljgr ' Maintain 1/a' space
to
designed to accommoda B' panel edges meet 4' where 4' edges meet, ;
incremental panel. panel edges., Unique edge Unique edge. profile is on
expansion and does not profile does not provide Wedge only.'
require manual gapping . : the tun 118' recommended
abng the 8' edges.• space m this siNatlon'
Step 2. Fasten the; panels to the framing members; with code approved
fasteners. Space fasteners 6' 0.6. along supported edges and 12'
O.C. at intermediate'supports, unless otherwise specified by;local
code or designer of record; it is the responsibility of ttie general
contractor to verii I
• yproperfastener type and spacing prior to
installation: Apply the fasteners 3i6';from•the ends and corners. 1ri
An ideal tn6ta9ation would be where fastener heads are flush with:
the panel surface.. However, due to variations in materials and
iimitations on equlpmertt, this may be difficult to:acbi - : inaame
situations: It is not required to tape over overdriven fasteners
unless.the fastener head creates'a hole through the entire panel
thickness, Please see the technical tip 'Overdriven:Fasteners'in •
-Zip System Roof -and. Wall- Sheathing," on iipsystem.com for
more information.:
07
ZIPSystem'" Tape Installation - Wall Panel. Seams
Apply 21P System tape after all ZIP System Roof & Will 'sheathingpanels are fully fastened to wall-framin§'members. Only ZIP System tape should be used
to seal the seams of ZIP System panels. Ensure that the dry
panel surface is and free. of, sawdust and dirt prior to taping. ZIP. system tape is a contact
tape that requires pressure for. an adequate seal. a
Step 1. Tape:all seams using ZIP System: tape: Ensure that the tape..
is centered over. the -seam within +/• i/2"" to, provide adequate
coverage and that wrinkles in tape are minimal.
Use the ZIP. System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles.
Step 2. Wherever tagespiices occur at a horizontal or vertical seam, create.
'
an ovedappirig splice of-at.least 3".
At T-joints, the tapap Is Gas should overlap by st least t Apply
moderate pressure onto the surface of tfie Is, to ensure a secure
bond between the panel and the tape:
Use the ZIP System tape gun or roller to apply pressure to the tape
and smooth out any wrinkles.'
Take special care to remove any voids an trapped air at spice
areas and T-Joints.
Step. 3.. Tape inside and outside comer seams.
Inside comer sewn
. Qufslde comersedm
Note:3ape.over any areas of the panel or tape that are damaged during construction. .
ZIP System® Roof & Wall Sheathing Installation Manual
O�
ZIP System - Window installation DlscL mER:ThefollowingstepsrepresentaGeneraloverviewfortheProperinstallatfon'olftdowflashing.Pleasedatertdcoriauft
the installation insbut:dorns of your window manufacturer as well as code requiremehls In your judsdictfon far lull tnatailatioir'details;
Flanged Windows
1. Fasten the ZIP System, sheathing'
to the wood frame and : tnstali
ZIP System tape to all wall pane!
seams,- as.:detailed in sections
02 and 03:
2. ZIP System:tape may be used as pan flashing if
Installed in accordance with flanged window
installation details posted on zipsystem.com.
Other, adhesive -based flashing tapes (must meet i -
ICC-ES Acceptance. Criteria for Flashing Materials
(AC148)) maybe used as pan flashing if installed
per ASTM 2112=07. Apply the flashing to cover
the bottom of the opening,:overhanging onto the
sheathing by at least.2' and extending a minimum
of 6° up each.jafrib.
3. Apply sealant around inside face of motinting
flange. Sealant must .be gapped. at the sill
to permit drainage. Install and level. window per ` }
manufacturer's installation itistriictions. Verify.
sealant compatibility with window manufacturer.
When using ZIP System tape as pan flashing,
butyl, 100% silicone oh polyurethane sealants
are acceptable. Do not use:latex or. other water -
based sealants:
4. Cut two pieces :of ZIP System tape or another
adhesive -backed flashing tape: (must meet ICC-
ES Acceptance Criteria tar 41ashing Materials
(AC148)) and apply to each of*the window jamb
flanges, ensuring .the jamb flashings .ovedap the.
sill flashing,
Once.the tape is in place, use the tape gun or roller f
to seat the flashing to the sheathing.
5. Cut a fength. of ZIP System.fape'or another
adhesive -backed flashing tape :(must meet ICC-
ES Acceptance Criteria. for Flashfrig Materials
(AC148)) and apply to the header, ensuring that
the.flashing overlaps the jamb flashings.•
Once the tape is in place, use the tape gun or roller
to seal the flashing to the. sheathing. '
*00 NOT tape bodorii flange.
6. From the interior,_appiy low-oressure polyurethane
foam (for windows) between the rough opening
and the Window frame. (Caulk sealant compatible ? -
with thd.sill flashing may be used. at.the.sill .if the
opening between the sill flashing and window �S
is too narrow to allow the use of low-pressure j
polyurethane foam.)
When .using ZIP System tape, :butyl, 100%
silicone or polyurethane sealants are acceptable.
Do not use IateX sealants with ZIP System tape, ff-
using another flashing tape, follow the. flashing
manufacturer's recommendation In selecting a
sealant -compatible. with that flashing.
Brick Mould Windows
1. Fasten the ZIP System sheathing
to the wood frame and install
ZIP System tape to all wall panel
seams, as detailed in sections
OR and 03.
1
2. If recommended by the window
manufacturer, cut a strip of wood
to function:as a back dam at the
sill. The wood strip should. have % €
a length equal to the width of the ¢
rough opening and a height and,,
width of at least 1/2". Position the
block, at thk inside edge of the
window name.
ZIP System -Window Installation DISCLAIMER: The tollowingstepsrepresentageneral 'd erviewfortheproperlristapatlonolw(ndowfisshing,pleasedeferldeonsuft
the InstelleUon'insWctlons of your window menufaeturer as well as cede requirements in your jurisdiction for full Installation details
Brick Mould -Windows (continued)
3. ZIP System tape maybe used as;pan flashing if "
Installed In accordance. with brick mould window
'Installation details posted on' zipsystem:com.
Other adhesive -based flashing tapes .(must meet
1CC-ES Acceptance Criteria for Flashing Materials
(A6148)) may be used as pan flashing if Installed
per ASTM 2112.07. Appiy:the. flashing to cover
the bottom of the opening, overhanging onto the
sheathing by:at least 2' and extending a minimum
.of 6' up each jamb.
4. For vertical jambs, cut ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing ,Materials
(AC148)) and apply to each of the window Jambs: .
Ensure that they cover the entire inside of the rough
opening as well as overlap onto the sheathing by
at least 2'. Flashing shall also :extend above the
rough opening, .such _that it will pro)ect 1' beyond °
the exterior trim of the window.
Once the tape is in place, use the tape gun or roller
to:seal the flashing to the sheathing.
8.. Applysealant to Jambs and header allowing for
dralnage, at the sill in accordance with window
manufacturer's. installation instructions. When
using ZIP'System.tape, use a butyl, pclyurethane
or. 100% silicone sealant Do not use latex or
.other .water -based sealants with ZIP System
tape. When using another fiashirig'tape, follow the
flashing manufao-hirer's recommendations in
selecting a sealant compatible with, that fleshing:
6.Install_and level window pe'r manufacturer's
installation instructions.
7. Cut a piece of rigid head flashing so that when
installed, it is flush with the edges of the exterior
moulding of the window. Apply a bead of sealant
to the back and. bottom surface of the rigid
head flashing, .Use sealant recommended. by the
flashing manufacturer.
8. Secure the rigid head flashing to ZIP System
wall sheathing,
S. Cut a Length of ZIP System tape or another
ac1fiesiv&backbd flashing tape (must meet IMES
Acceptance Criteria for Flashing Materials (AC148))
and apply to the rigid head flashing, ensuring �- ~
that the adhesive -backed flashing overlaps the
Jamb flashings
Once the tape is implace, use the tape gun or roller
to seal the flashing to the sheathing.
10: From the interior, apply IorwrPressure polyurethane.
foam (for windows) between the rough opening and
the window frame. (Caulk sealant compatible with
the sill clashing may be used at the slfl if the opening
between the sill flashing and_window is too narrow
to allow the use of low-pressure polyurethane foam.)
F:
When using ZIP System tape, butyl,100%silicone a I
or polyurethane sealants are acceptable. Do not
use -latex or, other 'Water -based sealants with ZIP
System tape. If using another flashing tape, follow
the flashing manufacturer's 'recommendation In
selecting a sealant compatible with that flashing.
�oclY
bP aYTIr+:YiwAi7+V:.lnf8lo
•LVp00,LNLT,0IEETAl
V&Mlil6V i3C.�4bFMp�p11
F.WELSppTy IAApSy
WipdEp OL6�Eo�E00E4
>7pyYTTEu4 TAPENNSTNlm
W�p�J� WTP ST61F/LA
I(iiASAI OT..
l4 ftHATALLT
t4VCNAT ALL TJ09Ra
WTTALLJ]POL'STEW TN'EItTMl
WTEPIORfd9,EA9 —�
FA6LENZPTISao WNl
- SHEAnH MRELKITff.D6{
. .
S�PESiGk �RECC110�ILOGIL
'
WALL'ASSEMSIY .. .. ...
ZIP SYSTEMD WAII SHEATHING
WOOD OR LT. GA METAL STUDS -
1134NCH GAP RECOMMENDED AT
PANEL EDGES UNLESS -
OTHERWISEPROVIDEDBY . . .. -
NACHOMOPROFILEDEDGES' f- <• .
a
INSTALL ZIPAY
ADHESIVE D,l rE _GOR ^ �;
(ARIST
MEET AC142) IN SEQUENCE FROM
BOTTOM, SINES, THEN TOP TO
ENSURE SHINGLE LAP OF ADHESIVE
BACKEp FLASHING ,
ZIPSYSTEMmTAPE
OVERALLJOINTS IN
WALL SHEATHING).
OVERLAP TAPE A MINIMUM OF
.14NCH AT ALL T.JOINTS
USE FLANGED ELECTRICAL.
BOXES OR MEMBRANE FLASHING
TO PROMOE FLANGES FOR : -
ELECTRICAL BOXES
1i
WALEMBLY :.. .. .. ..
P.M
MD WALL SHEA__
WOOD OR LT. QA, METAL STUDS
114 NCH GAP RECOMMENDED AT
PANEL EDGES UNLESS -
.OTHERWISEPROVBTEOBY
MACHINED PROFILED EDGES
INSTALL ZIP SYSTFMSTAPE OR
:. ADHESNE BACKEOFLASHINbIMUST
MEET AC740)WSEOIIENCE FROM
BOTTOM, SIDES' THEN TOP TO
ENSURE SHINGLE LAP OF AOHESIVB
BACKED FLASNRNG
LP SYSTEMDTAPE IINSTALLFO
OVER ALL JOINTS W ZIP SYSTEMS
WALLSHEATKNGI.
OVERLAPTAPEA MINIMUM OF
I4NCHATALLT,WINTS
USE FLANGED VENT HOODS
'wAu;AstEieLr (INSTALLED I rIBERCENENr 60WO .
CADONGMANUF OROANCE:. .
CLADONOIONRECCMUMA
ZIPSYS FUIS AULSHkATMUG NsI
ZOQD ORLT.WAl1ETALS UDS..
' NV 00 OR LT. 00. PETAL STUDS
1"CHO.WRECOMALEKEOAT � ..
PANEL COWS UNLESS
OIHLAN75EPRW1aPDSY `\ -
IIACHB1E17PAOFBFDEOCE+ S
WI
ZP SYSTEMS TAPE (NSTALSEO '.
OVER ALL JONTS W LPyYmEiie'
WALLSHEATHN% .. ... )`\ :fµ�, ?•p
u R.A
OVERLAPTAPEA UMVMDF ..\\ •�� �
INCH ATALLT.)pJTS
IAVNCH OAP RECOMMEN=AT.
PANEL F➢GE�UNtESs
OTMERWTSEPROV®EU BY
MACHPIEDPROFAEO EDGES
FASTEN'Z P SYSTEMS WALL. . .
SHEATHWGASREWWED BY
OESIONER4WRECO
2
0
OR LOGIL
BLODINGCOOE ... ..
WALL ASSEMBLY
BRICK VENEER -
\••
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING. CODE)
,
ZIP SYSTEM® WALL SHEATHING
••
WOOD OR LT. GA METAL STUDS;
NI
TOP EpGE OF FLASHING TAPED
WITH ZIP SYSTEM® TAPE OR
�
ADHESIVE BACKED:FLASHING.
(MUSTMEETAC148)
.CODE APPROVED BASE
FLASHING'
WEEP'HOLES (AS PRESCRIBED
BY LOCAL BUILDING CODE)
WALL ASSEMBLY
BNICK.VENEER
AIRSPACE (AS PRESCRIBED BY
LOCAL SUILDMG CODE)
ZIP SYSTEM* WALL SHEATHING '
WODD,CR LT. C.A. METAL STUDS . .
'iBWCiI OAPRE rEND EDAT
PAIiEI. EDGES UNLESS
OTHERWISE PROVIDED BY
MACHINED PROFILED EDGES
AP SYSTEMS TAPE (INSTALLED •� `
OVER ALL JOINTS IN Z P SYSTEMS
WALL'SHEATKN%
. b.
OVERLAPTAPEA MNIMULOF
L-INCH AT ALLTJOINT6� '
1184MCH GAP RECOMMENDED AT '
PANEL EDGES UNLESS
OTHERWISE PRO%MED BY
MACHINED PROFILED EDGES
an.
FASTER ZIP SYSTEMS WALL
SHEATHINGASREGUIREDBY .
bESIGNER-0FiiECORD OR LOCAL.
BLnLDwo cooE
WALL ASSEMBLY
BRICKBRICK ENVE ENE
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING'CODE)
ZIP SYSTEM®WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE'OF FLASHING TAPED
WITH ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AC148)
CODE APPROVED FLASHING--�
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE)
STEEL LINTEL I
INSTALL WINDOW IN
ACCORDANCE WITH DETAILS
24A-24D OR.25A-251) ..
WALL BEYOND
WALL ASSEM6LY
CODE APPROVED CLADDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S,
INSTALLATION -RECOMMENDATIONS) -
EXTERIOR RIGID INSULATION
DRAINAGE PLANE:(MIN. Ye")
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING:WITH ZIP SYSTEMS
TAPE OR ADHESIVE- BACKED. ,
FLASHING. (MUST MEETACI4Q);'
CODE APPROVED FLASHuur,
WALL BEYOND
BACKDAM PER -WINDOW
MANUFACTURER'S INSTALLATION
RECOMMENDATIONS:: . .
INSTALL -CODE -RECOGNIZED
SILOPAN FLASHING IN ROUGH
OPENING PRIOR TO WINDOW
INSTALLATION.
TOP EDGE OF FLASHING TAPED'
WITH ZIP SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
. (MUSTMEETAC148) :. ...
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE)
CODE -APPROVED. FLASHING
WALL ASSEMBLY
BRICK VENEER.
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING CODE)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
FOUNDATION
wove: ror optimal air leakage reduction, all uMeped'edges of the panels can be caulked, gasketed or sealed with a weatherstripping material.
'"'�*; �, `' � �' . � fi �°;,��k.��,»,'"` �•`'«tL+$c� � �;'x. � 'x i., a„ ,tr ,rz�� "a•`=t� y t,,p "t, k�„r`c ``t+`�"� °�C�«+� x �..
n�rW '»'4 'p,- �„k`xy .' `°�6."^x�.rrf,x"" ,•«�' "'`w'j
y ^v 'l A•.y k,:., I f+ wtT9T+JC Cy �t4 � �1 X 5, '"'„ A Y' � eL - t '.
" s., . :' + „y 1-r¢ xi eqm J1learn '� � � -�' � *v�r �, i' � °p` `X••„, �" a �'
� _ > ?t., � r.� y� � s � {tom �,+��� `(� �. v� k ;a• t ¢ A3 4""f '' �+ � tk F�. s•A`*
�"'i''�"_}�f` � � yy + .� � �' ;�"; +srs ' � �..;t�}� �';��,'rx,+.s"'wt'^a°��'��+r,.�+a�-"`� sue"' +w"�r..�`` "` i �rJ� { �•.7''i
��:`��" ; '�• k; ,%.' # �, •r.1"i ` „eft ^3`:0 � f wf = p« a�� �}*` ,Y'^. u'sz 14* ,...""ttt`�,�" t h� + t . »..
Or. t s� W '� .. �. '�• +yT"W4 ��+�'*� •a W "`,`,,,^'f r Y M `. _ x 'dw
.Al t y" •+�`' A; 1 ,ih ^. *� »��^.. R r'r..�.rd. s�"� a s w {,"V
- t� • . ' '* �_. �,�;* �`.. ; �`.a xt :'E '�" �, � T"�'i�• b «� t ,� ;y„ ,y. z»�,?� +. # +mow,
+ + .+ '% f'k '.. e p � !ax« n « .*. c $ x„,t"'r}"�'�, r,'i# 's s f*• +� «s,'.+ rr
;afk., r S. h. "' t ♦,'""'` s�-a",.�d�x4'+o 4 y�'' •a+• `*" Ez
Y y r 1 �{° r �*,. � a xa+j4r.. s �� �r� r � xa � r � �� iF ?T'• �` '��`�"»; ,, r., N ��� �
¢ r t � u 3.. � ;x.�,j✓`,. ,.4r �. s" a r "'`a_Z.y ry .s r �r"�dY Vx� 'v "�".' ! �x"�• !F .e ° � C A, '"' b x 'I' � :#'�C, '• # %N .? :i s y c r y s` 9 Ext' t raf > ny,
z;,Vi
y �� ,. � t. ^, ."+'" ��w 4E r ass* X N � 3 � rt � "• r 4 "° x '�Yt"•4" +ti�� $ F «�'��tm� „� P'�r; :� a .' �L k •' �•r r �
7R x� � 4 � . f .i ♦E � ♦ r... at)'`�x„ �• w
V �arR
wP r" 4 &
A'
�«4' y. ,. #- rc �w `� °'y�"•}^:.✓° `'� CpA��«rc "uy� :T«'"�'^' �;"w�5+�s �:*
T< i
«
l"vIV •. ', �. -j ��„ � �ri � .1�aF ,� rk ax �,,, �.� �^",- i��� ; �j aL�, j,� � g , Y�., � �;a r
ikKi
,y+x"4=It
si .. a '� ,� ry, a ° ', !t �'"• x" zyT. x"1 sf ,y. x „�' �('�}�a ew4,; r ��'s P" T s � "xi+< � « x'"� s ,. # w
vt
ik
�S4 n` ",,±` + ,y - � '�.p" �... � � ti+�B;'"'�YL t°'� t•'° b K�'"� ,fir i j.r �^ { � x :. � rJ.,"�
r .
k
'b ^' +, a x `'r� w " � t "R � ro • 2� t ' �..Tt �" ", a r d�F > ,' "` ¢•x ��
, x ,
ZIP :SYSTEM® SHEATHING WITH -HARD COAT STUCCO AT:
:.
BLOCK FOUNDATION WALL- OPTION A
H-2
TRADITIONAL HARD -COAT STUCCO -
INSTALLED IN ACCORDANCE WITH THE
LATH
MANUFACTURER'S OR THE'PORTLAND'
;:".•. CEMENT ASSC. (PCA)
RECOMMENDATIONS WITH THE MOST
RESTRICTIVE CONTROLLUNG,
ONE LAYER OF WATER -RESISTIVE
VAPOR -PERMEABLE BARRIER '
WITH A PERFORMANCE AT LEAST
_
EQUIVALENT TO GRADE D
BUILDING PAPER.
r
ZIP SYSTEM® SHEATHING-
....;. :...
.. . . TOP EDGE OF WEEP SCREED
.:..:.
TAPED TO WALL SHEATHING' '
WITH ZIP SYSTEM® TAPE OR
.:.+ •• .:
ADHE$(VE BACKED FLASHING.
(MUST 'MEET AAMA 711 OR
WOOD OR LT. GA.
METAL STUDS
ADHESIVE SACKED MEMBRANE
:'BRIDGE FLASHING CENTERED '
OVER TRANSITION JOINT (ZIP
~
SYSTEM TAPE MAYBE USED AS
o
o
THE BRIDGE FLASHING)
"
0
CODE-APPROVED
WEEP SCREED AT
BASE OF WALL
-
... VERTICAL AND HORIZONTAL
CONTROL JOINTSAS'NEEDED•
'
- DESIGNER -OF -RECORD TO
SPECIFY TYPE Ahb LOCATION:
MASONRY BLOCK WALL
-ZIP SYSTEM® SHEATHING IS APPROVED TO REPLACE.ONLYTHE
FIRST LAYER OF A TWO -LAYER UNDERLAYMENT SYSTEM.
• . :: DRAWING: NOT TO SCALE
N
• 6'P5yS&�TM : .
Sales Office:. 909250avid Taylor Drive
o
SHEATHING&TAPE
Suite 300: Charlotte; NC 2826.2
IIR
ENGINEERED
o
Telephone:-800.933.9220-www.zipsystem,cam
'IUB�I�
WOODS
ese constructio etails are provided t0-assist.in'the instal aeon o I -, ystem product s) an "may no every situation. Manufacturer accepts no reonsibit apply to
splity or liability for the
use- these or other Construction details.
Y TEM® SHEATHING WITWHARD COAT STUCCO AT
:
BLOCK FOUNDATION. WALL -OPTION A H. 2.
WALL ASSEMBLY . .
TRADITIONAL HARD -COAT STUCCO
METAL LATH
ONE LAYER WATER-RES. BARRIER
ZIP SYSTEM® SHEATHING'
W60D OR LT. GA. METAL STUDS '
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITN'ZIP.SYSTEM® TAPE OR
'ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711.OR'
AC148)
CODE -APPROVED WEEP
SCREED AT BASE OF WALL .
ADHESIVE BACKED MEMBRANE
:BRIDGE FLASHING CENTERED OVER .
TRANSITION JOINT (Z1P SYSTEM.. /
TAPE MAY BE USED AS THE BRIDGE
FLASHING) .
MASONRY BLOCK WALL
LATH
TOP EDGE OF WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP
SYSTEM® TAPE OR ADHESIVE BACKED \
FLASHING.:(MUST MEET AAMA 7'1:1 OR �• : '
AC148)
TRADITIONAL HARD-COATSTUCCO \
:INSTALLED IN ACCORDANCE WITH THE \
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC. (PCA)
RECOMMENDATIONS WITH THE MOST
RESTRICTIVE CONTROLLLING. 1
j
ONE. LAYER: OF WATER -RESISTIVE ..
VAPOR -PERMEABLE BARRIER -WITH A
PERFORMANCE AT, LEAST EQUIVALENT
TO GRADE D BUILDING PAPER.
'CODE=APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT (ZIP SYSTEM
TAPE.MAY BE USED AS THE BRIDGE
FLASHING)
MASONRY BLOCK WALL
'ZIP. SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER,UNDERLAYIAEN7`jQSI #qT TO SCALE
CY : Sales Office: David Taylor Drive
N
Suite 300- Charlotte, NC.28262 . VE GINEERED
SHEATHING & TAPE Ju ODDS
Telephone::800.933.9220 - www.zipsystem,com
These construct on etails are provided to assist in the instal ation o IP ystem products an Imay'!n!otapply,to
every situation. Manufacturer accepts no responsibility or liability for the. use of these or other construction details.