OCEAN HARBOR SOUTH CONDOMINIUMS
4200 NORTH HWY A1A – SOUTH BLDG – BLDG. B
THRESHOLD INSPECTION REPORT
SLC BUILDING PERMIT NUMBER: 2106-0288
PROJECT NAME: Ocean Harbor South – Bldg. B DATE: March 16, 2022
CLIENT: Elliott Merrill Community Mgmt. LOCATION: Ft. Pierce, FL
CONTRACTOR: Structure-Con PROJECT MGR: Khris McConnell
INSPECTED BY: Todd Rhoten WEATHER: Sunny
WORK INSPECTED:
Units 409 & 609
OBSERVATIONS:
Unit 409
• (6) PT cables have been locked off and new cable sections have been spliced at the north balcony edge.
• (2) #4 bursting bars behind the PT cables have been replaced.
• All exposed reinforcing bars have been power tool cleaned and coated with the approved corrosion inhibitor.
• Form boards for the first pour are in progress.
Unit 609
• (1) PT cable at the north edge has been re-stressed and the post pocket is ready for repair.
• The surface spall under SGD the has been repaired and concrete has been placed.
• The SGD has been reinstalled and the temporary wall has been removed.
RECOMMENDATIONS:
Unit 409
• Place concrete at the balcony edge, leaving the PT cable splice coupler and lock off plate exposed.
• Allow the concrete to cure a minimum of 72 hours prior to re-stressing the cables.
• Remove the remaining abandoned core mounted railing posts at the north and west balcony edges.
Unit 609
• Grout PT pocket solid with high strength non-shrink grout.
______________________________ _________________________________
Michael Lue, P.E. Todd Rhoten
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 21-145B Report No. 4
Client:
Building Official:
Contractor:
File
Mr. Gene Ross- Elliott Merrill
SLC Building Department
Mr. Bob Stark-Structure-Con
Mr. Khris McConnell-Structure Con
Page 2 of 3
Pic 1 – 09 stack
Northwest elevation
Pic 2 – Unit 409
North balcony edge removed and PT cables locked off.
Pic 3 – Unit 409
PT cable lock off and new splice.
M L Engineering Inc.
Consulting Engineers
Threshold Inspector
2030 37th Avenue
Vero Beach, Florida 32960
Phone: (772) 569-1257
Fax: (772) 569-4041
www.mlengineeringinc.com
Project No. 21-145B Report No. 4
Client:
Building Official:
Contractor:
File
Mr. Gene Ross- Elliott Merrill
SLC Building Department
Mr. Bob Stark-Structure-Con
Mr. Khris McConnell-Structure Con
Page 3 of 3
Pic 4 – Unit 409
Abandoned core mounted railing post
Pic 5 – Unit 609
PT pocket
Pic 6 – Unit 609
SGD reinstalled