Loading...
HomeMy WebLinkAboutDrawingSTAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) ANCHOR WITH #B SOUD COPPER `— BOND WIRE WITH APPROVED CLAMPS 98 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS NICHE ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST CONFORM TO THE 2011 N.E.C. AND APPLICABLE LOCAL CODES W/P G.F.I. WATER PROOF G.F.I. MUST NOT BE MORE THAN 20' FROM POOL EDGE AND NOT WITHIN 6' OF POOL EDGE a N.E.C. 2011 SEC. 880.22(3) .i 12 V LIGHT TRANSFORMER W/P DISCONNECT POOL TIMER W/S.T. TOGGLE -SWITCH O N.E.C. APPROVED 1' PVC CONDUIT 3-112 IN 1/2' CONDUIT OPTIONAL 2ND LIGHT JUNCTION-BOX(S) MIN OF B' A80VE POOL DECK POOL DECK wi..Jl'Li�ti ELECTRICAL DETAIL NOTE: ALL ELECTRICAL WORK SHALL CONFORM TO N.E.C. 2011 SEC. 880 File Copy JON a � 201 PEPU-An-ragG1 St. Lucie Counf!, FL 1-#8 SOLID BARE COPPER 18'MIN-24'MAX CONT. PERIMETER BOND WIRE WITH APPROVED CLAMPS 4' TO 6' BELOW SUB -GRADE BOND TO ENTIRE EQUIPMENT ALL-INGROUND PERIMETER POOLS 1-#8 SOLID BARE COPPER BOND WIRE WITH APPROVED CLAMPS 0 (4) SIDES OF GUNITE POOLS BOND TO POOL STEEL EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTION OF THE N.E.C. 2011 SEC. 680.26