HomeMy WebLinkAboutProduct Approval Metal RoofingRECEI, D JUN 14,2017 File Copy
9/15/2015 Florida Building Code Online
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
FL11651-R2
Revision
2014
Approved
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-7852
ray@gulfcoastsupply.com
Ray Bowen
ray@gulfcoastsupply.com
Category Roofing
Subcategory Aetal Roofing,
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Daniel S. Kuhn
PE-75519
Keystone Certifications, Inc.
04/12/2024
Locke Bowden
Validation Checklist - Hardcopy Received
FL11651 R2 COI Cert of Ind Kuhn Ena.odf
FL11651 R2 COI Letter of Name chanae.odf
Standard
Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL1897
2004
UL 580
2006
Sections from the Code
https://floridabuilding.orgtpr/pr app dM.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 1/5
9/15/2015
Florida Building Code Online
Product Approval Method
Method 1 Option D
Date Submitted 07/01/2015
Date Validated 07/10/2015
Date Pending FBC Approval 07/18/2015
Date Approved 08/18/2015
Summary of Products
Go to Page is 0 0 Page 1/ 2 0 0
FL # i Model, Number or Name Description
11651.1 1 0.032" Aluminum 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
11651.2 10.032" Aluminum Gulf Lok
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
psf @ 5 3/16" o.c. fastener spacing. Install per
manufacturers details. Not for use in HVHZ Zones.
0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R2 II 14FL11651 1 R2 0325vCrimo 15-
32Plvwood NonHVHZ.odf
FL11651 R2 II 14FL11651 1 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 1 R2 0325vCrimo 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R2 II 14FL11651 2 R2 032GulfLok 16 15-
32Plvwood NonHVHZ.pdf
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 2 R2 032GulfLok 16 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
111651.3 1 1" 24ga. Gulf Snap 11" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For use
in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 2 R2 Metal Roof Panel Detail.odf
FL11651 R2 II 14FL11651 3 R2 1 24GulfSnaD 17 15-
32Plvwood HVHZ..odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 3 R2 1 24GulfSnao 17 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.4 1 1" 249a. VersaLoc 11" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For use
in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 4 R2 24VersaLoc SR 16.5 15-
32Plvwood HVHZ..odf
FL11651 R2 II 14FL11651 4 R2 Metal Roof Panel Detail..odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 4 R2 24VersaLoc SR 16.5 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
111651.5 1 1" VersaLoc .032" Aluminum ( 1" VersaLoc .032" Aluminum over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-101.OPSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For use
in HVHZ Zones.
Installation Instructions
FL11651 R2 II 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..odf
FL11651 R2 II 14FL11651 5 R2 Metal Roof Panel Detail..odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R2 AE 14FL11651 5 R2 lin 032VersaLoc SR 16 15-
32Plvwood HVHZ..odf
https://floridabuilding.orgtpr/pr app df.aspx?param=wGEVXQwtDgsQFc5K%2rrrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d
215
9/15/2015
Florida Building Code Online
Created by Independent Third Party: Yes
11651.6
1.5" 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 6 R2 Metal Roof Panel Detail..Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
Evaluation Reports
per manufacturers detals. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 6 R2 1.5 24GulfSnao 16 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. VersaLoc
1.5" VersaLoc 24ga. 16" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 7 R2 1.5 24VersaLoc 16 IS -
32Plvwood HVHZ..Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 7 R2 Metal Roof Panel Dbtail..pdf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. For use
Evaluation Reports
in HVHZ Zones.
FL11651 R2 AE 14FL11651 7 R2 1.5 24VersaLoc 16 15-
32Plvwood HVHZ..odf
Created by Independent Third Party: Yes
11651.8
2" 24ga. MegaLoc
24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 8 R2 24MeaaLoc 18 15-
32Plvwood NonHVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 8 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-308.SPSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. Not for
Evaluation Reports
use in HVHZ Zones.
FL11651 R2 AE 14FL11651 8 R2 24MeaaLoc 18 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 9 R2 24GulfLok 16 15-
Approved for use outside HVHZ: Yes
32Plvwood NonHVHZ.pdf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 9 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
Created by Independent Third Party: Yes
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
Evaluation Reports
fastener spacing. -161 psf @ 5-1/8" fastener spacing.
FL11651 R2 AE 14FL11651 9 R2 24GulfLok 16 15-
32Plvwood NonHVHZ.Ddf
Install per manufacturers details. Not for use in HVHZ
Zones.
Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins
over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 10 R2 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 10 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
Created by Independent Third Party: Yes
details. Not for use in HVHZ Zones.
Evaluation Reports
FL11651 R2 AE 14FL11651 10 R2 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.11
24 Ga. Gulf Seam
24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 11 R2 24GulfSeam 18 IS -
32Plvwood NonHVHZ.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 11 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
Created by Independent Third Party: Yes
o.c. clip spacing. Install per manufacturers details. Not for
Evaluation Reports
use in HVHZ Zones.
FL11651 R2 AE 14FL11651 11 R2 24GulfSeam IS 15-
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.12
26 Ga. 5V Crimp
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
https:/Moridabuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDgsQFc5K%2fFrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 3/5
9/15/2015
Florida Building Code Online
541
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 12 R2 265vCrimo 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 12 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
Created by Independent Third Party: Yes
@ 6" o.c. fastener spacing. Install per manufacturers
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FUI651 12 R2 265vCrimo 15-
32Plvwood HVHZ.odf
Created by Independent Third Party: Yes
1651,13_ t
_26 Ga. 5V Crimp -
26�Ga.-5V Grimp,over..15/32x Plywood ' f
Limits of Use
Installation Instructions -�
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL11651 R2 II 14FL11651 13 R2 265vCrimo 15-
32Plvwood NonHVHZ.odf
Impact Resistant: N/A
FL11651 R2 II 14FL11651 13 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf
Created by Independent Third Party: Yes
@ 16" o.c. fastener pattern. Install per manufacturers
Evaluation Reports
details. Not for use in HVHZ Zones.
FL11651 R2 AE 14FL11651 13 R2 265vCrimo 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 14 R2 265vCrimD 1x4 15-
32Plvwood NonHVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 14 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
Created by Independent Third Party: Yes
@ 6" o.c. fastener spacing. Install per manufacturers
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 14 R2 265vCrimo 1x4 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 15 R2 26GulfLok 16 15
32Plvwood HVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 15 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Created by Independent Third Party: Yes
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener
Evaluation Reports
spacing. Install per manufacturers details. For use in HVHZ
FL11651 R2 AE 14FL11651 15 R2 26GulfLok 16 15-
32Plvwood HVHZ.Ddf
Zones.
Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 14FL11651 16 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75
Created by Independent Third Party: Yes
psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
Evaluation Reports
spacing. Install per manufacturers details. Not for use In
FL11651 R2 AE 14FL11651 16 R2 26GulfLok 16 15-
32Plvwood NonHVHZ.Ddf
HVHZ Zones.
Created by Independent Third Party: Yes
11651.17
26 Ga. GulfPBR
26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 17 R2 26GuIfPBR 15-32Plvwood NonHVHZ.Ddf
FL11651 R2 II 17 R2 Metal Roof Panel Detail.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf
Evaluation Reports
@ 12" o.c. fastener pattern. Install per manufacturer
FL11651 R2 AE 17 R2 26GulfPBR 15-
details. Not for use in HVHZ
32Plvwood NonHVHZ.Ddf
Created by Independent Third Party: Yes
11651.18
26 Ga. GulfPBR
26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 18 R2 26GulfPBR 1x4 15-
32Plvwood HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL11651 R2 II 18 R2 Metal Roof Panel Detail.odf
Design Pressure: +N/A/-151.7PSF
Verified By: Dan Kuhn, P.E. 75519
https://fioridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 4/5
9/15/2015
Florida Building Code Online
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
For use in HVHZ Zones
FL11651 R2 AE 14FL11651 18 R2 26GulfPBR lx4 15-
32Plywood HVHZ.Ddf
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R2 II 14FL11651 19 R2 26GulfPBR 15-
Approved for use outside HVHZ: Yes
32Plvwood HVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 19 R2 Metal Roof Panel Detail.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf
Created by Independent Third Party: Yes
@ 12" o.c. fastener spacing. Install per manufacturer's
Evaluation Reports
details. For use in HVHZ Zones.
FL11651 R2 AE 14FL11651 19 R2 26GulfPBR IS-
32Plvwood HVHZ.Ddf
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
26 Ga. GulfPBR over lx4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R2 II 20 R2 26GulfPBR lx4 15-
Approved for use outside HVHZ: Yes
3.2Plvwood NOnHVHZ.Ddf
Impact Resistant: N/A
FL11651 R2 II 20 R2 Metal Roof Panel Detail.Ddf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
Created by Independent Third Party: Yes
@ 12" fastener spacing. Install per manufacturer's details.
Evaluation Reports
Not for use in HVHZ Zones
FL11651 R2 AE 20 R2 26GulfPBR 1x4 15-
32Plvwood NonHVHZ.odf
Created by Independent Third Party: Yes
Go to Page 0 0 Pagel/ 20 0
Back Next
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click bere .
Product Approval Accepts:
Cred t�,,Arri
hftps://floridabuilding.orgipr/pr_app dti.aspx?param=wGEVXQwtDgsQFc5K%2ffrZeCSHgw99R5wgNNppMyNezj3512E8POQwgA%3d%3d 515
Product Evaluation Report
GULF COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. SV Crimp Roof Panel over 15132" Plywood
Florida Product Approval #11651.13 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61 G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Gulf Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 W %111111,"
Newberry, FL 32669 �.%` P�•11EL S, k1-40
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation, Report Pages 1 - 5
N -
* ' o. 75519 •
STATE OF '
�'�s;0JVAL EN��•`�
0il0i
2015
' 'I*
. Zi. `_ -
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description:
5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened
roof panel with fasteners in the panel flat over minimum 15/32" plywood decking.
Non Structural application.
Panel Material/Standards:
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s):
Thickness: 0.018" Minimum
Width: 24" Coverage
Rib Height: 3/s" Major Rib
Panel Fastener:
#9-15x1.5" with sealing washing in the flat of the panel or approved equal,
1/a" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description:
Minimum 15/3z" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures:
FL# 11651.13 R2 91UNE 15, 2015
Table "A"
Fastener Pattern 12"-12" 9.5"-2"-9.5"
Design Pressure includes a Safety Factor = 2.0.
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 - Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 117-0053T-05.& 117-0331T-08
2. Certificate of Independence
By Dan Kuhn, RE. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Organization # ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
Section 1507.4.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
FL# 11651.13 R2 • JUNE 15, 2015
Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL# 11651.13 R2 • JUNE 15, 2015
ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 15/32" Plywood
120
130
140 150
16-_ 170 180
WIIND
FASTENER
SUBSTRATE
SPEED
Penetration)
(MIN. 15/32")
ON CENTER
ON CENTER
ON CENTER ON CENTER
k�CENTER ONON CENTER ON CENTER
SPACING
SPACING
SPACING SPACING
SPACING SPACING SPACING
ZONE 2
#9-15x1.5"
Plywood
16" TYPE 1
16" TYPE 1
16" TYPE 1 16" TYPE 1
16" TYPE`7� 16" TYPE 1 16" TYPE 1
r-.• sa
1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. A" PENETRATION.
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0
PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN.15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2014
ZONE 2 ZONE 3 f
>Z-
_...-...... _............ - ...-- ..........RIDGEZONE1-------------
Note: Dimension (a) is defined as 10% of the minimum width of the building or
a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
less than either 4% of the minimum width of the building or 3 feet.
ZONE 2 GABLE ROOF
--__------------------ a
I I
I
j RIDGE
- -- - - - - - a
+---------------------+ a
I
ZONE 1
I I
�..._\..... . . . ..... ..... ..... _ ... ..... ..... ..... ..... ..... .._ .. .... ..... ..... ..... ..... ..... ...... ...I ..
"-ZONE 3 '-SAVE
FL# 11651.13 R2 0 JUNE 15, 2015
TYPE I FASTENER PATTERN
(1) #9-15 x 1-1/2" HWH w/Sealing Washer
1211 1211-
At Panel Lap
TYPE 2 FASTENER PATTERN
(1) #9-15 x 1-1/2" HWH w/Sealing Washer