Loading...
HomeMy WebLinkAboutFL40264 METAL SALES 5V3111122, 7:49 AM Florida Building Code Online i,u tgk Business& ProfessionalRegulation BCIs Home I Log In 1 User Registration Hot Topics I Submit Surcharge Stats & Facts Publications contact Us BCIS Site Map links 5earch bo ■*"-" Product ApprovalIUSER: Public User Product Approval Menu > Product ar Applicatior Search > AppGcatian List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL40264 New 2020 Approved Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 (502) 855-4300 dstermer@metalsales.us.com David Stermer dsterme r@ meta Isa I es. us, corn Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Bala Sockalingam Evaluation Report Florida License PE-62240 Quality Assurance Entity Keystone Ceruflcations, Inc. Quality Assurance Contract Expiration Bate 12/27/2026 Validated By Yoosef Lavi, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections From the Code FL402 4 RO CQ1 ertifi a Independence.{Ldf Standard TAS 125 UL 1897 UL 580 Year 2003 2012 2006 https:llwww.floridabuilding.orgiprlpr_app_dtt,ar,px?param=wGEVXQwtDgvzydBM6Lrr-PIXErslgBLxArRTr-rudl3rrjOkgeUK3SCw%3d%3d 1/3 3/11/22, 7.49 AM Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL* I Model, Number or Name 40264.1 j5V-Chmp 11/24/2021 11/29/2021 12/05/2021 02/08/2022 Description Min. 26 ga., 24" wide through fastened roof panel over min. 15/32" thick plywood deck or 7/16" thick OSB with fasteners through panel rib. Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO II Eva] uaLion Repo 2516 1,pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-183.5 Evaluation Reports Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c. FL40264 RO AE EvaluationReps rtC2516 1.pdf and 183.5 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes 40264.2 Aluminum Image II 16" wide, nom 0.032" thick aluminum concealed fastener roof j panel over min 19/32" thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 R,O, II EvaluationReportC2516 2.pdf Approved for use outside HVHZ; Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-173.8 Evaluation Reports Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c., F 40264 RO AE EvaluationReRQqC 516 2.W 107.4 psf at fastener spacing of 6" o.c. and 173.8 psf at Created by Independent Third Party: Yes fastener spacing of 6" o.c, with support strap & adhesive. 40264.3 I Aluminum Vertical Seam Nom. 0.032" thick, 16" wide, aluminum standing seam roof panel over min. 15/32" thick plywood deck or 7/16" thick OSB Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO II EvaluationReportC2516 3.pdf Approved for use outside HVHZ; Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design pressure: +N/A/-97,1 Evaluation Reports Other: Uplift load of 41,6 psf at clip spacing of 36" o.c., 71.0 FL40264 RO AE Eva] uationRepgdf2516 3.pdf psf at clip spacing of 12" o.c. and 97.1 psf at clip spacing of 12" Created by Independent Third Party: Yes o.c. with sidelap adhesive. 40264.4 Aluminum Vertical Seam Nom. 0,032" thick, 16" wide, aluminum standing seam roof panel over min, 19/32" thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No 171-402 4 RO II v luati Rep_or[C2516 4.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-162 Evaluation Reports Other: Uplift load of 41.6 psf at clip spacing of 36" o,c,, 100.2 FL40264 R0 AE Fvaluationgyp2rtC2516 4.pdf psf at clip spacing of 12" o.c. and 162.0 psf at clip spacing of Created by Independent Third Party: Yes 12" o.c. with support strap & adhesive. 40264.5 Image II Min. 26 ga., 16" wide concealed fastened roof panel over min. 15/32" thick plywood deck or 7/16" thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO II _Eva lualionReportC2516 5.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116 Evaluation Reports Other: Uplift load of 20.8 psf at fastener spacing of 24" o.c., L4_0264 RO AE ,EvaivationRep Cart 512 6 5.ndf 63.5 psf at fastener spacing of 6" o.c., 86,6 psf at fastener Created by Independent Third Party: Yes spacing of 6" o.c. with sidelap adhesive and 116 psf at fastener spacing of 6" o.c. with support strap & adhesive. 40264.6 Image II Min. 26 ga., 16" wide concealed fastener roof panel over min. 19/32" thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO IT Fvalu tionReportC2516 6.pdr Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design pressure: +N/A/-139.1 Evaluation Reports Other: Uplift load of 84.3 psf La fastener spacing of 24", 102.7 FL40264 RO AE EvaluationReportC2516 6.pdf Created by Independent Third Party: Yes https://www.floridabuilding.org/prfpr_app_dti-aspx?param=wGEVXQwtDgvzydBM6LrrP1XErslgBLxArRTCrudl3rfjOkgeUK3SCw%3d%3d 2/3 3111122, 7:49 AM Florida Building Code Online psf @ fastener spacing of 6" and 139.1 psf @ fastener spacing of 6" with 3/8" bead adhesive in sidelap 40264.7 Vertical Seam Max. 16" wide, min. 24 ga. standing seam roof panel over min, 15/32" thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO II EvaluationReportC2516 7,pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/ -top Evaluation Reports Other: Uplift load of 30.0 psf at clip spacing of 48" o.c., 73.0 FL40264 RO AE EvaluationReportC2516 7.pdf psf at clip spacing of 24" o.c., 114.3 psf at clip spacing of 8" Created by Independent Third Party: Yes o.c. and 200.0 psf at clip spacing of 12" o.c. with support strap & adhesive. 40264.8 Vertical Seam Max. 18" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL40264 RO II Eva luationReportQY 16 8.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-105 Evaluation Reports Other: Uplift load of 36.6 psf at clip spacing of 48" o.c., 82.5 F 4 RO AE Fv IuationR Cpq,rl_ 2516 8.pdf psf at clip spacing of 12" o.c. and 105,0 psf at clip spacing of Created by Independent Third Party: Yes 12" o.c. with sidelap adhesive. Sack f4ext Contact Us :: 2601 Blair Stone Road,_ Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cop-0ctht20o7-2013 State of F€orida.:: Privacy Statement :: Accessibility statemert :: Refund Statement Under Florida law, email addresses are pub€ic records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139s. *pursuant to Section 155.275(l), Florida statutes, effective October 1, 2012, licensees ffcensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click her, Product Approval Accepts: 71 17J WR eCheck Credit Card Safe https://www,floridabuilding.org/pr/pr app_dti-aspx?param=wGEVXQwtDgvzydBM6l.rcP1XErsigBLxArRTCrud13rrjjOkgeUK3SCw%3d%3d 3/3 EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 7TH EDITION (2020) FLORIDA PRODUCT APPROVAL FL 40264.1 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX. (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Load Span Table (1 Page) Report No. C2516-1 Date: 11.23.2021 .......... /,. V °' No Z?=40 ` '. STATE OF FL 40264.1 C2516-1 11.23.2021 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or ruin. 1/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws at 6" o.c. (Minimum) in the plywood field and edges. Designed as per FBC 2020. New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 30.0 psf at fastener spacing of 36" o.c. (Factor of Safety = 2) 183.5 psf at fastener spacing of 6" o.c. Fastener .Pattern: Type: #10-14 hex head wood screws with sealed washer_ Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8" and installed as per Metal Sales current installation procedure. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4, At panel ends 6" o.c. across panel width At intermediate 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-12 `Uplift Tests for Roof Covering Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress FL 40264.1 C2516-1 11.23,2021 Page 3 of 3 design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & 1897 Test Reports Farabaugh Engineering and Testing Inc. Project No. T243-21, Reporting Date 9/21/202t g z�z J a d Lit L LJ Lo lyI k R. J 0 W W Ln y 1 1 oosti—sss--zos zozOm (-'4 `311minoi ooF JAns `Is ok H1nos 9b9 dW0 0Ni8ni0vAnNvr4 saws 1v13w Sl-99L�Sy8 �%Yi LSbS-L64-BL6 3NOHd 7 311fIS '3AY 9N1$NYj N BLLL 'd "()-Hd 'MVIMIT030S YiVB stwim my l3Wd dAINO-A9 Lno6 Z ~o�Q W J q - IS- � Q V�op �� W D = W z O cp W O XZ-7 0 LU c� U x�odlU�zO o a N �QaC9z=�� Q W z ,, a O n z W W W- IL V f� H No=IL W 9 2 O w �znmod�v' 7 W W O n It o w�0—w,u-'�o Z „ o ¢cUiS Wow aoO,�w¢O F U U O Z w S r.N z urz rz,�a wzin o�¢z bU� Ii Ntn��Z�" O Z fn W [7 o��Od »i.�ia oo��ZOWow� U mQWpw�� ~c9 WLnn w4�Op_ �Ztr err rr fl Z�-`-JCS w"_-W-- 2 c�000WwcszWJ9��oQ lrwMw4wW Q w��F�u7�d4Qmrr�siC Ov Z Y U _ U_ T C�jaU a4 O M �C-4I "- oxr�j U[V E0p3 _Ln� wtna zt,� I J � w � Q ~ LU Li 0 Q � Woo w � � z w � wQo z gam = o � W Z Zoo z J t'z W Z zoo oz z zo DE5c) ?o �¢ zo wap w� z�Z w a �z Wo METAL SALES MANUFACTURING CORPORATION 5V-Crimp Uplift Loads (Min, 26 ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psf) Coverage width: 24" Panel Fasteners #10-14 hex head wood screws with sealed washer 6 183.5 9 122.3 12 91.8 15 73.4 18 612 21 52.4 24 45.9 -v 40.8 36.7 27 30 33 33.4 36 30.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 40264.1 and Metal Sales current installation procedure. I Three or more spans condition. 1216 N Lansing Ave.. Suite C Tulsa, Ok 74106 918 492 5992 No €i224 J t 1. -z?,, 2O`2� Bala Sockalingam, Ph.D.. P.E. FL 62240