HomeMy WebLinkAboutSet-Up Manual AddendumI SET=UP MANUAL ADDENDUM JA ;OBS HOMES N 600 PACKARD COURT SAFETY HARBOR, FLORIDA (727).726-1138 I NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. _ - - n il REV-01 /10 0 ALL HOMES SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C- contact the Department of Motor Vehicles 850-413-7600 1 NOTES: ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REOUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R-VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0, WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN 1 PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND, DUCT SUPPLY OR RETURN HOLING SSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/HOUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WILL. RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. APPROVED BY "15m INC NOTICE DRAWN BY: DATE: REV. LETTER: HOMES TNESE SPEonuTNxrs AND ORAflLNGS ARE C.L.Y. 5-30-95 CIAONAL. PROPRIETARY AND CONfWTIAL DRAWING TITLE. MATERIALS OF .IACOBSEN MANIXACTLIRINC P.O. BOX 368 W- 2" WATERLALS ARE PROWO TO THE EXTERIOR A/C DUCT SAFETY HARBOR. FLORIDA 34695 RECPQiT FOR SPECIFIC PJrM AND MOST BE DRAWING NUMBER - PHONE (813) 726-1138 IVT CMUNTIAL NO SEOIET n= OTNETS AD-AC-0001 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED.STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTROLLED AND MAY BE MANUALLY OPERATED. TO DIC_CONT1mUE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) APPROVED BY INOf .` r141NIC"'. "ClIfttW V�fl110 wrt SamMOM1p►tIWrOWtti NOTICE: DRAMH BY: C.L.Y DAIS: 9_28-95 REV. LETTER: JACOBSEN HOMES rAESE sKonunONS AND WWM AM B 01MI, ®RM KTART. AND 0WIDOMAL DRAMNG llM ARE PROMM 10 TIC P.O. BOX 368 MATERIALS OF JACO85EN MANUFACTUtwG W.H. VENT. SYS. „ SAFETY HARBOR. FLORIDA 34695 A(cpad Fat vccncs RRP= uD *AT K ORAYMG NUMBER:* PHONE (813) 726-1138 IVI COWIDDrnA AND SEm nm omoa AD-AC-0100 3 ADDENDUM MULTI —WIDE UNIT FLOOR FASTENING FLOOR JOIST 0.131' X 1 1 /2' MIN. 3/8' X 3 1/2- MIN. LAG INSTALLED SEE NAILS OR 7/16' X 16 GA. CHART FOR MAXIMUM SPACING, STAGGERED STAPLES PER TABLE: FROM SIDE TO SIDE AT AN APPROX. 45' ANGLE FROM VERTICAL. SEE DETAIL BELOW IF GAP EXISTS BETWEEN FLOORS. 0,016' X 1 1/2' MIN. STEEL STRAP ® 48 O.C. MAX. SPACING 1 4' TO 3 4' GAP WITH FASTENING INTO JOIST EACH SIDE OF CENTER LINE PER TABLE BELOW: FOR GAPS IN FLOOR SYSTEMS INSTALL WOW SHIM AT ALL LAG TO 1/f, INCREASE LAG LENGTH 1' LOCATIONS FOR LAG SCREW TO GO NDS01 AND FOR GAPS TO 3/4% INCREASE THROUGH AND TO KEEP CONNECTION (ALL ZONES) TIGHT. (SEE NOTE 2) LAG LENGTH 1 1/2'. (ALL DGKWRES) WD ID!E coxaK 3X X 3 1/i LAG SCREtr 30 GA. STRAP FASTM W/ 7/ii' X 19 GA. STAPLES We We DrosuR_E Lf+ORNL NL]j M OF FASTODS REOU 0 o.131' X 1 1/f NAILS 7/11r X 16 GA. SUIRES MAN" SPAS MAX•Lu11 SPACING .� IV DG 2 1/4' 0A 3 S 2 2 V 17• D.C. 1 71f = b' 4 7 If O.0 Y ox- 'C' 4 7 3 3 b• le ac 1 1/Y (M b• i e NQTTESo DIGNM APPiiOYAL• DAM NVIMAL• APPROVED BY I. 1' MK IDOUTXXI IS REQJRM ON STAPLES FOR YK 0.016' STRAP. Revised �^ Z ,0� 2. WW WINS 70 BE � FROM SPF p UK OR BETTER (r X 4' X GAP DOTAL WL S&I say 2a,2oo6 P11INC. OSB OR PLYil000 MAY BE USED F T Dun EQUALS GAP MDTH-4' X 4' OL 30rJohn C. DL an, p t,. 3. IW NAMA SDEVALL HWff. C . !�2 En H ring, :'!u FEDETTAL MANUFACTURED NONE CONSTRUCTION AND SAT ETY STANDARDS 4. � CTHLR DETAIS fiXl SEAIDIG fLGORS FOR AM lFLIiAR01l JACOBSEN HOMES r-m 9TWWASSM AG D11 WN= W °R"""" 81' M T DAM Q5-22-06 REV. LETiEk Cox 36aORI D�,L. TmT AM cmomwK w> Dr JAC01 1 MAHiA ASM We S" M„MW AN �n 10 x DRAW 11TLLb M FLOOR FASTENING ARS SAFETY HARBOR, na1roA 34e9s PHONE (813) 726-113a I�a>BTI Berns ROM NO rust K om cor onLL me ar Am oHn DRAW NUMM AD—FA-0001 ADDENDUM MULTI -WIDE UNIT WALL FASTENING ENDWALL ��N����Dee��SQ�01 iu TM: 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF EXTERIOR WALLS. .131N X 3 1/2' MIN. NAILS 8' O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE -NAILED). MARRIAGE LINE EN6 W APPROVAL DAPIA APPROVAL• APPROVED BY Revised S �b May 24,2006 John C. Doeden, Pl. INPIINC. K2 Engineering, Irla RONAL NA"ACTUNEO NDM CDNSTRUCT=AND SAFETY STANOANDS JMEJ FT JACOBSEN HOMES PA BOX M 1MN � DiAVO Aa rWWMIAR% MO garmu" L WTO U w i1 mm ~Acpj" u"� or M T "' 05-22-06 R~ LLFIUC B WANG 1111E M/W WALL FASTENING �3�1389SVTm�� wt marAmm AA[ P"0►Cea 10 m NO DRAwc 1uetPHO(e j i261 m �IXN � AD-FA-0010 5 ADDENDUM MULTI —WIDE ROOF FASTENING CENTER LINE OR MATING LINE OF TRIPLE WOE UNITS 30 -GA. GALV. STEEL STRIP01 SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING (SEE CHART ON AD—FA-0001 MAX SPACING). .30 GA. GALV. STEEL STRIP '6' X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET— UP MAN. OVER GAL STRIP. I (30 GA. GALV. STRIPS USED MAY BE KIND DEFLECTORS REMOVED FROM -LAG SCREW SET BACKS ROOF IN ORIGINAL CONDITION, FOR TRIPLE WADES EXCEPT FOR STAPLE HOLES.) FOR DOUBLE WI ES �\ PLAN VI 1 4' 2 3 4' 3/6' X 5' LAG SCREWS ..LAG SCREW ME BACKS TRIPLE WOE ROOF UNE� _ (2 1/4' SMOOTH SHANK) FOR DOUBLE WIRES INSTALL LAG SCREWS _ SEE CHART ON AD—FA-0001 .�/'— FOR TRIPLE KIDES AT A 45' ANGLE FOR MAXIMUM SPACING / STAGCEREO 2 1 4 2 3 4' 14'TO34'GAP ROOF PERIMETER RAILy I OR RIDGE BEAM (FOR ROM BEAMS SEE NOTE /4) CROSS—SECTION INSTALL WORD SHIu AT ALL LAGFOR CAPS IN ROOF SYSTEMS FOR GAPS TO 3/4', INCREASE LOCATIONS FOR LAG SCREW TO GO AND FOR TO 1 INCREASE LAG LENGTH TROUGH AND TO KEEP CONNECTION NDS01 LAGTLGFIT. c LENGTH 1 1/2'. (SEE NOTE 2)REF CALL. PG. (ALL ZONES) CROSS—SECTION iW//�!. C WA- 91.01- 91.07 (ALL EXPOSURES) NOTES: DIGNDA APPROVAL: DMIA APPROVAL• L 2 I/r' WL PDIERAAON INTO REOUwm HENBEB IS RE"a FOR LAG Spirit 2. TADD 2W 10 K IIF FROM SPF A UK OR KT7EPL APPROVED BY (Y X 6' X CAP wav NIL SIZE) (02 OR R7IFOOD NAY K USED IF 7HIWESS EQUALS GAP MD1 4' X 6- MR SZE) Z SEE OM OETALS FOR MUPLEiD1G ROOF NIEAEC7i0lL � / � vis AIyReed s , 2006 i24 4. *0 FWALLM A LAC SCREN KM A Ma ^ FRSi-ORAL LL 3/IF John C.1J08�, P �.ON INC. A aLARMCE NOSE 7HROM THE FIRST ROM KALL SEC% -ORiL A 1/,V HOLE 1HR000L ft K2 E.ngr7eernrg, Inc FEDERAL MAWFACTUAEO NOME RECE)IING RIDGE KAN FOR 7HE THREADED PM10 OF LAG W F f THESE DNS ARE CONSTRUCTION AND SAFETY STANDARDS FOR 31V LAG =REMIS MY. S We MAMM SEML HEIGHT. JACOBSEN HOMES THg SFiC711'JETNlo06A.DgGS1FGS Ni DRANN Elt M.T. DAZE 05-22-06 \I P.O. BOX 368 PRaNUNIT. AM od.>o wm 1ux;wu or Aams l �ACRF" � SM WATUM AK MAOM to THE DRAriHG 11LE M%W ROOF FASTENING SAFLs7Y HARBOR. FLORIDA 3{6115 PHONE (613) .728-1138 AE> mff F111 gum p rm No um K WT C"wax on =lET RON MEL CRATING HLIM ! AD-FA-0020 6 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIEW 29 GA. MIN. GALV. STEEL ROM CAP COVERING LENGTH OF ROOF (MIN. f OVERLAP AT SEAM) SECURED WITH #B X 7/16' HEAD X Y' FULLY THREADED SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB WUTHIN END ZONE) SEALER STRIP BETWEEN RIBS OR CLOSURE STRIP RUNNING ENTIRE LENGTH OF ROOF Ref: EX-13-0051 and AD-FA-0020 NDS01 (ALL ZONES) (AL- EXPOSURI!S) T-- CENTER OR MATING LINE I I .I 8 X 7/1r HEAD X 2' j L.LY THREADED SCREW (NO MORE THAN 12` O.C.) I I � I o a 1 1 1 8 m m 1 � 1 v 1 1 1 METAL ROOF PANELS STOP APP. -3' FROM CENTER LINE "k-30 GA. GALV. STEEL STRIP V X LENGTH OF ROOF (SEE AD-FA-0020) SECURED WITH 7/16' X 16 GA. STAPLES FIAT. PENETRATION INTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING) I. SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS APPROVED BY L STANDARD 7/16' O.S.B. (24/16 INDEX) ROOF SHEATHING. S. METAL PANELS ARE 29 GA. MIN. STEEL WITH 9' O.C. RIBS. V 7 IN S10,2008 I. SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND @�'0100.'r�ii, •� 7A1INepC. ME TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN rfoeuu MONAD SAFKANUFACrUREST g� �TIG consrnurnon ano saFEnr srnxo.aos ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) Lmnm Bpi D.M.T. 08-25-08 JACOBSEN HOMES ►MMAM AM GMAL rAnr. AM WFOOM OA V= ME METAL ROOF RIDGE CAP P.Q. 80X 368 MAISM W AACMM MAIW�ACIC�l6 W. 5M MA78AU ME POM A M SAFEW MAM P HO�(s13) ins-1i138 4605 WT oo mw Fm � °� AD-FA-0021 rA ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING \ (SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES NOTES: 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE t. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS PROVED BY REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). a1rJ t 5 {7iM Vw/K1lRmIQE INC . 71Ki� YO WCTY SU/OYtiy NOME. DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES nesE sKO11 7MS AND DRAWNCS ARE C.L.Y. 6-5-95 ■ CRIMAL PROPRIETARY: AND CCNROENTTAL DRAWING 11T1F P.O. BOX 368 MATERIALS CF JACOM UANAACMUC M/W ROOF SEALING „ SAFETY HARBOR. FLORIDA 34695 NC 20 MATERIALS ARE PROKO TO TNE PHONE (813) 726-1138 P cR TIAL �KOM 110 `o`n+'T>�B °RA"Nc NUMBER: AD—FA-0025 8 ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) 0 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES - HIGH SIDE 15# FELT UNDERLAYMENT _ MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) BY JUN 1 5 W5 INC JACOBSEN HOMES N°ncDRAWN BY: DALE: �V• �II>x TNESE sPEarTuna+s NO DruD wNcs ARE � C.L.Y. 6-5-95 CRIGNAT. PROPRIETARY, AND COWIDEMTIAI. DRAWING TITLE:- P.O. BOX 368 YATERIAES OF JACOWN YANR'ACIMIG M/W ROOF SEALING DIG WOli YATERLA S ARE PRONDED TO THE SAFETY HARBOR, FLORIDA 95 i WNO PAND DRAWWG NUMBER:PHON(813) 118 VTCOWIAL SEwnu� AD-FA-0026 9 SHIPPED LOOSE HEARTH EXTENSIONS HEARTH. TNSTAI f.AT10N• I. REMOVE ANY CARPET AND/OR PAD FROM UNDER THE HEARTH EXTENSION AREA 2 INSPECT THE METAL FLASHING IN THE HEARTH AREA TO INSURE THAT IT HAS BEEN INSTALLED (THIS FlASW MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FIREPLACE AND THE HEARTH). 1 LOCATE THE HEATH EXTENSION (SHIPPED LOOSE N THE HOME) AND INSTALL FOLLDMNG THESE STEPS A. CAREFULLY PLACE THE HEARTH EXtMON N THE PROPER LOCATION N FRONT OF THE FIREPLACE ASSE 3X IL SECURE THE HEARTH EXIEN90N TO THE FLOOR W/ 4 18 r 2' WOOD SCREWY C. FILL THE AREA BETWEEN THE FACE OF THE FIREPLACE AND THE HEARTH EXTENSION WLTH A NON-COMBUSTABLE CAUUMG OR MORTAR. D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND TYP. HEARTH (MAY BE SHIPPED LOOSE) 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, TILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING APPROVAL• APPROVED BY .JW 2 8 t995 4DLMlmw1f#=mmm IN cawft=a#m&vm J AC 0 B S E N HOMES NOTLCE DRAWN BY:. DATE REV UTTER �� ��,7M ,,,,D DRAMwa ME C.L.Y. 6-16-95 r9s OffiGNAL. PROPRIETARY. Afro COHEWTK DRAWING TITLE P.O. Box 368 MATEMALS Of .IACOM MA "ACTL UC SHIP -LOOSE HEARTH SAFETY HARBOR, FLORIDA 34695 RIG R M MATERLALS ARE PRONDED TO THE PHONE (813) 726-1138 IVT CMMIK AND �S�y j� DRAWING NUMBER AD-FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A -I working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY QEV. INIIWA t 5 20 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDAHUS SET-UP MANUAL ADDENDUM AD-FS-0001-A 11 TRUSS SHEATHING APPROVED BY I '41� NP]INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STMDM DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW HINGED TRUSS - OUTLOOKERS TO PASS THROUGH. TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES rr , I , o", , 14 - /�x L SIDEWALL _ PENETRATIONS OF THE SHEATHING ON THE TRUSS(ES) FOR 7`1E OVERHANG OUTLOO M (PURUHS). ATTIC VENTALATION. OPENINGS IN TRUSS SHEATHING MAY BE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE TRUSS. (IB' X 14 1/2- MAXIMUM SINGLE OPENING SIZE IN TRUSS SHEATHING ;:•_`O MARRIAGE WALL 3/8' MIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SHEARWALLS (APPLICABLE TO ALL SHEARWALLS) 3/8' SHEATHING TO BE INSTALLED ON -SITE. WINOZONE III (I10 MPH) ALL EXPOSURES NOTES: ENGINEER APPROVAL: - DAPIA APPROVAL 1. 3/5' MIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16' X 1 1/2' X 1S CA- MIN. STAPLES 1 1/4' O.C. AT PANEL EDGES AND 3' D.C. Al ALL FRAMING MEMBERS. (NO GLUE REOUMM) APPROVED BY 0 r14 MAT E a tuva S N INC, K2 FEDERAL MANUFACTURED HOME �)�, CONSTRUCTION AND SAFETY STANDARDS Z9. JACOBSEN HOMES NOTICE: THESE sPEanunoNs AND alAwwcs ARE DRAWN BY: R.R. DATE 4-27-98 REV. LETTER: ■ „ P.O. BOX 368 ORIGINAL. PROPRIETARY. AND COWIOENDAL MATERIALS OF JACOBSEN MANUFACIURING DRAWING TITLE: SAFETY HARBOR. FLORIDA 34695 PHONE (BiJ) 726-1138 W. SIICH MATERIALS ARE PROWDED TO 1HE REPI�CNr rcR wfOfIiAL x KNIM Sr vE TRUSS SHEATHING —` DRAWING NUMBER: iAND o AD—HR-0001 12 HINGED ROOF DETAIL COMM OF VAMI TO RASE ROOF RW WIN Pmm ID SET-1P Pam l5 APPROX 22 to. al ma ROOF Sfm smmmlar WIH APART. UXAX IFIM P= trite 3r W 00 W ROOF KC11014 M AOD 1FWC WHN 2FWOFA911Ct:N1KRNM HINGED ROOF IN SHIPPING POSITION HINGED ROOF IN SET-UP POSITION NDS01 NOTES: 1. WAfi RAtU ROOF SECT O! N H RALSiD POMM WME S141 U H = NG POM KID Pas= HtU xKc POST TD WM it ^ 6 w j3 fm m POST TOP m •110ItT■MSOUDR3-tlYr am REF. CALC. PG. C-RF- 223.0 - 223.6 John C. Doecien, Pk. X2 EnlTir e*rmg, Inc )AM APPROVAL• APPROVED BY NilRevised Jun 06,2006 � INC. FFDFRAI YANIFArr NFD HOW CONS7RUCTION AND SAFETY S7ANOAMYS JACOBSEN HOMES lm > NO WAUM ME umm. M MMMY, ND COI.nNXM W11aMl GF �I YANFA00M mot BY. O.A. 06-02-06 A DRAl1NC MILE: HINGED ROOF DETAIL PA Box 36e LN UG 9= YATtAO AW FWAOM 10 lE DRAVW NIAIBER AD—HR-0002 SAFETY HARBOR FLO WA 34695 Oft la 94�fIG PRM NO UC K. gol ones a PHONE (813) 726-1136 m wT Omn L NO 13 HINGED ROOF DETAIL LWERLAYMENT TO BE GWED 3" MIN. ON BOTH SECIMS, OF HRNCE ROOF. FOR WIND ZONES 2 AND I RAISE EXTENDED SHINGLE AND UNDERLAYMENT k@- AND A MIN. 4 1/f 1NDTN OF ROOFING CEMENT TO TOP OF LAST SHINGLE ROW ON FIXECI ROOF SECTION. (M IS TO BE DONE BEFORE RAISING HINGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X fi X B' BLOCK BEHIND 2 X 6 - OVERHANG FASCIA BOARDS AND SECURE WITH 3-15 X 3' WOOD SCREWS EACH SIDE CF GAP. APPROVED BY 11110110.0 Revised N1 Nov 30,2006 INC. fEDERAI DANUFACNRED19011E . ODN6TRIILTIDN AMD SAFETY STANDARDS BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS 1NNDZONE 11 (110 MPH) ALL EXPOSURES MOTES: FNGlW APPROVAL-• DAPIA APPROVAL I. PACE RAM ROOF SECTICR N 11E RAISED P0970 BEFIX STIWONG HINGED KNG POSTS IIR) POSIIi@L John C. D09dM P-I. K2 End I• JACOBSEN HOMES ram �cF maa Am oa►Wm ME MAIM or D.T. °" 10-02-06 UL REV. lF1TER Mmn a+ • PRaP CM- AM aol WMX DRAW 117M . AR eox >se � � ID 7W HINGED ROOF DETAIL SAFETY HAR80R. FLORIDA 34693 MCMIT RR 3= RMPM AID AM K DRAW NUM6ER PHOHE (613) 726-1138 anDosmoQ"=aDior.Ras AD—HR-0003 14 SHINGLE AND UNDERLAYMENT APPLICATION ON HINGED SECTION INSTALL ON SITE 15# FELT WITH A 6- MIN. OVERLAP ONTO MAIN . ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 ONE-PIECE SHINGLE CONTINUE 15# FELT TO ROOF PEAK UNDERLAYMENT 0 2• MIN. OVERLAP (TYP.) o F N _'6' MIN. TAR AS SHOWN .(APPLIED ON SITE) I............ 1 :: SEE NOTE:.::::::. j r� r MR SEE DETAIL 'A' 1 I � SECURE FIRST ROW OF SHINGLE TO BE INSTALLED ON SITE WITH • 6 STAPLES (1' X 3/4" X 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTALLING THE 15j FELT AND SHINGLES. DETAIL -'A NOTES: 1. CEMENTING OF 15f FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2 FASTENING OF 15j FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) - . 0 3. EXTEND THE FIRST LAYER OF ON SITE 15# FELT ONTO THE FIXED ROOF A MR OF 6' AND UNDER THE LAST COURSE OF FACTORY INSTALLED SHINGLES F NEEDED TO MAINTAIN THE 6- MIN. OVERLAP ONTO THE FIXED ROOF. 4. INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS: AD-HR-ODD1 (WITH SPECIFIC END PANEL LA1f0U11 AD-HR-000Z AD-HR-000b, AND AD-HR-0004. cill JACOBSEN HOMES xoB NM MUM AK GNINAL PROPRETAR7. AR0 CoIFaDm MAIMS OF dAoaW MMWACRIM „ P.O. BOX 368 NC. KIM MAIMALS AK PRONGED 10 lE SAFETY NE(111HARBOR. FLORIDA 34695 K" MUM AM � � �� PHONE (a13) 726-1138 WINDZONE III (110 MPH) ALL EXPOSURES A PROVED BY Sep 12 INC. FEDE AL MANUFACTURED HOME MN RUCTION AND SAFETY STANDARDS M.T. 9-20-03 SHINGLE AND UNDERLAYMENT AD—HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4' SCREWS, 6-1/2' O.C. MAX DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 1/16" X 1 1/2" X 16 GA. STAPLES INTO EACH 15' O.C. RAFTER 'AND 3 1/2" O.C. MAX. INTO 2 X 4 RAIL. (TYPICAL BOTH SIDES) NDSOI NOTES: I. SEE AD-HR-0007 FOR INSTALLATION OF UNDERLAYMENT AND SWNGLES. SEE AD-HR-0002 FOR ASSEMBLY DETAILS. ALL YWNDZONI ALL EXPOSURES 20 PSF ROOF 10 PSF D.L CRC - 167.01 - 167.02 KER APPROVAL DAPA APPROVAL _ APPROVED BY Revised O� IN JtErl 09,2006 Jahn 0. uot�, f F.E. nlNC. FEDERAL MMNIFACFURED NOtlE CONSTRUCTNNI IND LFETY R�IIDtliDS ER."ring, ITEC: JACOBSEN HOMES mu wEer"Dws me MOWS me vm By O.A. I DATE: 06-06-06 REV. LEnE"` P.O. BOX 368 MONA- PRCFIKIART, AND CwmTw wasor itcom "A<," W- MW YAID U ARE PW ED 10 TIE DRAMG ARE: PEAK INSTALLATION DETAILS A SAFETY HARBOR., FLORIDA 34695 RECRO" PHONE (727) 726-1t38 rCR VECFr HNGQS AIID IRAs IE mr ooynolnu ANo SLOW Fam amn ORATANG IAl16ER AD—HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE . 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. INSTALL FIRST LAYER OF 151 FELT TO ROOF WITH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF OEC( AND/OR E)OSTING FELT AS SHOWN. NOTES: TOP COURSE(S) OF SHINGLES TO OVERLAP PEAK AS SHOWN. SHINGLE INSTALLATION SEE OTHER DETAILS FOR STE INSTALLED ROOF PEAK UNDERLAYMENT INSTALLATION INSTALL TOP LAYER OF 151 FELT TO ROOF MOTH A 6' MIN. WIDTH OF ROOF CEMENT Al EACH END TO ROOF DECK AND/OR EMSTING FELT AS SHOWN. IBY AUG 01204 INC. J AC O BS E N HOMES IH:SE sPcoPlu►NMDRAIN BY: DATE: REV. LETTER TRWS NO AMo oaA.lcs ARE M.T. 7-2$-04 = MAL PRWKTARI. NO CCWIMNnAL DRAWNG TITLE: _ „ P.O. BOX 368 YATMALS OF JACOM YANWACTLOIK SHMHGI.E/UNDERLAYIIENT INSTALLATION RIC 9" YAIMALS AK PROHMD TO 1K SAFETY HARBOR, FLORIDA 34695 MCF61 FOR 9i0AX PIAFM NO BAST of DRAMWG IARJBER: PHONE (727) 726-1138 IPI CaILDIIUL NO MET nKm O MM AD-HR-0007 ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT �- FASTEN TO FLOOR FRAMING MBAR W/ STAPLE OR NAIL BANDING STRAP 14RAPPED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. ODE OF NOT LESS THAN 1/4' PER FOOT MUST BE MAINTAINED TOWARD THE I OUTLET. WHERE THIS GRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8- 001"MAY BE USED WHEN A FULL SIZE CLEANOUT IS INSTALLED AT THE UPPER END. .. J VIEW OF DRAIN PIMP 1. PIPE CLEANER AND CLUE SHALL ALSO BE SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. 2. 48" O.C. MAX. SUPPORT SPACING. JACOBSEN HOMES DEsE 5KCIRAHO4 MO DRAW=ARE. Tice Dow BY. R.R. CAh 7-17-97 rsv. tETiQt: i d AAA FRM'Afir, Arm CofM'{AL DRAIM 1111F_ YAIOE.ALS OF VM& YANVACIYROC P.O. eex 36e n_ mm VIRAL$ Ara klov m la na PLUMBING SUPPORT SAFETY HARBOR, FLORIDA 34695 PUM FCR V=Fuvoo:T AM rust a uDRANNG NIMUL- PHONE (813) 725-1135 an coxrmma"lou nmv onus AD-PL-0001 18 I NOTES: OPEN PORCH RAILINGS) IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. PPROVED BY MAR V � INC. l HOME R STANQAPA JACOBSEN HOMES ntOTTce �»� T,T. UAIt �V• �I I&R: TNESE SPECIFTCAnoNs MO ORAIYNCS ARE M.T.3-30—OS ORIONAL. PROPRIETARY, AND CDNFTDENBAL DRAWING 71M _ P.O. BOX 368 INC. SUMMATERIALS N �,� �� OPEN PORCH RAILING(S) SAFETY HARBOR, FLORIDA 34695 RECIPIENT FOR SPECFIC PURPOSES ND MST BE DRAWING NUM: PHONE (727) 726—tt38 KEPT CONFWTK AND SECRET Fft OTIM AD—PO-0001 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST & ROOF), SOLAR TUBES AND PLUMBING 4 1- VENTS SEE AD-PR-7007 & 7009. MAX. ROOF SLOPE FOR ROOF DECKING DETAILS SEE AD-PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE FOR ROOFING DETAILS SEE AD-PR-7002 SEE AD-PR-7008 SHIP THIS SEC. LOOSE — — --(SITE INSTALLED) FOR OVERHANGS SEE AD-PR-7003. FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED \— FOR ROOF VENTING BOTH FACTORY —1 POLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD-PR-7005 & 7006 ON SITE PITCHED ROOF RAFTERS CENTER SECTION OF TRIPLE WIDE F TYPI -\L TRIPLE WIDE HOME REF. PG. IW-07-0011 WITF SITE INSTALLED PITCHED FOR FASTENING C ATER SECTION RAFTERS NOTES: DAM APPROVAL: APPROVED BY 010 Revised 25,2007 OctONp I INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOnCL DRAYN BY: DATE REV. LETTER: JACOBSEN HOMES Dm sKcwATIDNs AMD DRAYS m ARE O.A. 10-24-07 mocl OMMA4 PROPKTARY, AND coNmaiNnAL DRAVANG TITLE: P.O. BOX 368 MA MALS OF'AMM MANUFACROW ON SITE PITCHED ROOF DETAILS PC. SO MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 RECPEMT FOR SPEDFi6 PIRP O AND WST BE DRAVANG NUMBER: ® PHONE (727) 726-1138 KEPT CatfTDEMUUL AND SECRET M OTHERS AD-PR-7001 20 ROOF- TO ROOF ATTACHMENT SECURE SITE INSTALLED ROOF DECKING WITH 7/16' X 1 1/2' X 16 GA. STAPLES (12) EACH SIDE OF MARRIAGE LINE TO EACH 16' O.C. RAFTER. SEE DETAIL 'A' SEE NOTE 11 11' MIN. SITE INSTALLED DECKING OVERLAP FACTORY INSTALLED ROOF DECKING ING oodoop- SEE NOTE /2 18' MIN. MAY BE RIDGE BEAMSI DECKING NIp (SEE NOTE J4) I CROSS—SECTION REF. PG. RC-07-DO44 NDS01 1. SECURE EACH 16' O.C. RAFTER TO RAIL BELOW VNTH 2—/10 X 4 1/2' SCREWS AT EACH RAFTER END. SITE INSTALLED PITCHED RAFTER TO ALIGN WITH FACTORY INSTALLED RAFTER. (EA. SCREW TO HAVE 1 1/4' PENETRATION MIN.) 2. ATTACH MATE LINE RAFTER RAILS (OR RIDGE BEAUS) WITH AIO X 4 1/2' SCREAMS 9' QC. MAX. SPACING. SITE INSTALLED 7/16' MIN. ROOF DECKING SECURED MATH 7/16' X 1 1/2' X 16 GA. STAPLES. 2' O.C. MAX. TO EACH 16' QC. RAFTER. SITE INSTALLED RAFTER TO ALIGN WITH FACTORY INSTALLED RAFTER BELOW. FACTORY INSTALLED RAFTER (CENTER SECTION) C-FS3 - 88.01 3. SEE AD—FA-0020 FOR CAP TREATMENT BETMAEN SECTIONS. I .;ohn C. boeaon. R6. JACOBSEN HOMES Mao „ P.O. Box 30 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 K2 EngkmerkV. Inc. NOTTCAL 1 CRATM at ,NESE �ranva AIE7 W.,rks ME a.orr..29o.s,.r.. wo mnoo�29 a DRA1Mfi TITL: wlowus Cr .rcnEeg29 wiur�clue11c ROf Mc sm VATDE;11S AM PRo►am to >H KOM Rl KaC MUD MI IM Ei DRAWNG NI M evr eawrlrw so smatr llm owc 1RNOZONE'0 ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. DAPIA APPROVAL: APPROVED BY NIHINC. 2006 FE0E29u runs�aullH 11029E COIISTRUCr10N •110 sNEW STANDAMS O.A. 1 06-02-05 )F TO ROOF ATTACHMENT A AD—PR-7002 21 RAFTER TOP END ZONE RAFTER./OVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OLIMOKER 19' O.C. MAX BETWEEN OUTLOOKERS -/ oc ""� 2 X 6 OVERHANG FASCIA THIS TRUSS NSWED ON SITE BOTTOM CHORD 160' DOUBLED END ZONE RAFTERS TYP. 16' O.C. 19.0 Alq 0 48.0 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .131' X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT. AND . MIN. (3) .131' X 3' NAILS FASTENING FASCIA NJTO END OF NAILING BLOCK 2 X 6 OUTLOOKER 19' O.C. MAX BETWEEN OUTLOOKERS ALL OUTLOOKERS SHOWN ARE 2 x 6 SPF 13 FLAT SEE CHART FOR FASTENING OUTLOOKER TO TOP CHORD -MULIIPLE TRUSSES FASTENED TOGETHER W/MIN..131' X 3' NAILS OR MIN. 7/16' X 2 1/2' X 15 GA. STAPLES 16' O.C. MA10MUM INTO TOP k BOTTOM CHORDS ONLY. 2 X 6 FASCIA FASTENED TO OUIL.00KER —/ %-- 2 X 6 OVERHANG FASCIA W/Ii9N. (s) 7/16' x 21/2' x is GA. END ZONE ASSEMBLY NoIE: STAPLES OR MIN. (3) .131' X- 3' NAILS (SHIPPED ASSEMBLED FOR SITE INSTALLATION) OULOOK s TO BE SECURED 10 EACH TYPICAL AT ALL CENTER BRACES 1rBlss Of 1}E DOUBLE TRUSSES LOCATED ( ) IN 1HE ENOZONE PER FASTENER CHART. -t S G E TRUSS ONLY T REQ'D OUTSDE OF i6' iYP. ili TYP. 3 FT. AREA EXTRA TRUSS MAY BE PLACED ON E11HER SDE I NDSO1 1. ALL TRUSSES LOCATED WITHIN 36' OF THE END OF THE R SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTT M PER AD-PR-7002. TYP. OUTLOOKER FASTENING: FASTENERS: OUARM. . FilETRAim J31 PD NAIL 5 1 1/f 15 GA. -STAPLE B 1' #8 SCREW 2 1' (INCL TB') OUILDONER FASTOM MAY BE IMAM MANDZONE 111 FROM TOP CHORD DOW IF PEIETRAI N ALL EXPOSURES B WHAINED. (110 MPH) 20 PSF ROOF 10 PSF D.L. C-RC-197.01-197.02 '--177-1e09, .John C. Doeden,'Rk. .K2 Englnae,, ing,- Inc, APPROVED BY ON Feb 05,2008 INC. FEDERAL 11ANI1FACI1IRED MOPE CDNSTRUGTION AND SAFETY STANDARDS JACOBSEN HOMES Man P.O. BOX 368 11E5ESPEG,.',.TlcA1DDRA..AK 0RR1m PKPR umT ND UMFE um YATOM DF .UICOm MNl11F'ACO1�6 IN U`"""`ff` O.A. °"" 1-29-08. RD 1tnM A DRAWING TITLE: END ZONE RAPIER OVERFFANG ASSEMBLY SAFEW HARBOR. FLORIDA 34695 PHONE (727) 726-1138 mw WT omfowm = mm Tit011 am DRAWING NufAlT� AD—PR-7003 22 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16" ON CENTER TRIPLE WIDE CENTER SECTION PEAK AK � - — - -� -I - SITE INSTALLED DECIONG ON PITCHED NO BLOCKING REQUIRED TRUSS SECTION k REMAINDER OF AT CONTINUOUS PANEL BOTH OUTSIDE SECTIONS (2 FULL ROWS OF SHEATH% SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE TRIPLE WOE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES H I �MANUF. INSTALLED DECKING TO HERE MIN. WIDTH PER SEA NG REQUREAIENT APA RATED ROOF DECKING (OR EQUAL) 9 v WINDZONE Al ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF O.L NOTM 1. 1/e MAXIMUM GAP AND 1/16" MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES. APPROVED BY 2. ROOF DECKING MATERIAL TO BE 7/16" APA RATED ROOF (24/0 Revised o0o SPAN RATED) DECKING (EQUAL OR BETTER). ,Jo n C. DO: R Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THEEflCLI ic•:i;i;, !EiCi. AiNC. SAME DECKING PATTERN. FEDERAL ■ANUFACfURED HOPE 4. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1 /2" X 15 CANSTRUCfION AND SAFELY STANDARDS GA. STAPLES AT 30 O/C EDGES AND FIELD NOTIC& DRAW BY DAIS REV. IJam! JACOBSEN HOMES 1NF� 11Dm me D Nm O.A.to-24-0� 000ML F My AM DRAYIING 111M P.O. eox 368 YATi1 is DT AMMSEN MANUFACRFM ON SITE PITCHED ROOF DECKING INST. 01-orm Nc SUCH MA70M Ni Pr#A n 10 RE SAFETY HARBOR. R-ORIOA 34895 FZPW F5t SPMc 11IfRW NO MUST K DRA11M1G FiIYBFR PHONE (727) 726-1138 WT aD1iIiMiHIL� No S m fro Omm AD-PR-7004 23 SITE INSTALLED PITCHED ROOF VENTING TYP. 50 SO. IN. ROOF VENTS (SEE AD-PR-7006 FOR QUANTITIES) TYP. 100 SQ. IN. CUTOUTS FOR VENTILATION OF ROOF SECTION (SEE AD-PR-7006 FOR QUANTITIES) FLAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION J / CEILING PANEL CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: SITE INSTALLED CENTER SECTION OF ROOF OVED BY rIRevised Oct 25,2007 NC. MANUFACTURED HOME CTION AND SAFETY STANDARDS NOTICE: DRAWN BY: ANC D O.A.uAlt: 10-24-07 Ner. LL"rX ❑ ❑ JACOBS EN HOMES THESE SKaMATION� ymGS A�A ORIO UC RNOPNCSM, AND CONFiUFNM DRAWING TITLE: MATERIALS OF JACOM MANUFACTURING ❑„ P.O. BOX 368 W, SUQi M ATERLUS ARE PROVED ID nRE SITE INSTALLED PITCHED ROOF VENTS SAFETY HARBOR, FLORIDA 34695 RECKNT FOR SKOFX ROM AND MAi BE DRAWING NUMBER, ❑❑❑❑ PHONE (727) 726-1138 KEPT CONFMTi41 AND SECRET FROM OTHM& AD—PR-7005 24 ROOF VENTING MARRIAGE WALLS I I TYP. too SQ K CUTOUTS FOR a_f V61tATO OF ROOF SICIION (SEE DWI FOR REPAMENTS) 100 SA. IN. CUTOUT VENT HOLES R N SECTION REQUIRED IN FLAT ROOF (1601 X SECTION LENGT)t LUToul HOLES 0 TO 15'-6' 1 15'-6• TO 31'-3' 2 31'-3' TO 46 -10' 3 46'-Ur TO 6 -6' 4 62'-6 TO Ge-Gr 5 I I MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I I MARRIAGE WALLS / LOW _VENT LOW VENT a-lp •SO SO. IN. VENTS REQUIRED 3 HIGH VENT IN SITE INSTAUED TRUSS SECTION ---r— CENTER LINE OF CENTER SECTION (m) : KCID7 IP161c mm rat I to. tort I0 31'-I M3�& 4 - 10 fi-i ii to iS- ar AMY= 10 POWAK WHIS TYP. 50 SO. N ROOF VENTS LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: PROVED BY JUN 1 4 1 INC AL MANUFACTURED H061E RUCTION AND SAFETY STANDARDS NOTT M DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES MNSKCFC1TM NO NMI100AK R.R. 01-22-04 000WL. PROPRCTA". AM OWMIRK DRAWING 11TLE: _ P.O. 80X 368 MAMMS or AMCCM ~ACRMC ROOF VENTING 0t 9" MAMIMS AW PRDWW 10 1K SAFETY HARBOR. FLORIDA 34695 Wrott FOI SKM ftal [S AIO PSI K DRAWING NULEIER• PHONE (727) 726-1138 Ivy cwto zk me WWI nm OHM AD-PR-7006 I I MARRIAGE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED I I MARRIAGE WALLS / LOW _VENT LOW VENT a-lp •SO SO. IN. VENTS REQUIRED 3 HIGH VENT IN SITE INSTAUED TRUSS SECTION ---r— CENTER LINE OF CENTER SECTION (m) : KCID7 IP161c mm rat I to. tort I0 31'-I M3�& 4 - 10 fi-i ii to iS- ar AMY= 10 POWAK WHIS TYP. 50 SO. N ROOF VENTS LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: PROVED BY JUN 1 4 1 INC AL MANUFACTURED H061E RUCTION AND SAFETY STANDARDS NOTT M DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES MNSKCFC1TM NO NMI100AK R.R. 01-22-04 000WL. PROPRCTA". AM OWMIRK DRAWING 11TLE: _ P.O. 80X 368 MAMMS or AMCCM ~ACRMC ROOF VENTING 0t 9" MAMIMS AW PRDWW 10 1K SAFETY HARBOR. FLORIDA 34695 Wrott FOI SKM ftal [S AIO PSI K DRAWING NULEIER• PHONE (727) 726-1138 Ivy cwto zk me WWI nm OHM AD-PR-7006 ar AMY= 10 POWAK WHIS TYP. 50 SO. N ROOF VENTS LOW VENT (SEE CHART FOR REOUREMENTS) LOW VENT MARRIAGE WALLS SITE INSTALLED CENTER SECTION OF ROOF. DAM APPROVAL: PROVED BY JUN 1 4 1 INC AL MANUFACTURED H061E RUCTION AND SAFETY STANDARDS NOTT M DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES MNSKCFC1TM NO NMI100AK R.R. 01-22-04 000WL. PROPRCTA". AM OWMIRK DRAWING 11TLE: _ P.O. 80X 368 MAMMS or AMCCM ~ACRMC ROOF VENTING 0t 9" MAMIMS AW PRDWW 10 1K SAFETY HARBOR. FLORIDA 34695 Wrott FOI SKM ftal [S AIO PSI K DRAWING NULEIER• PHONE (727) 726-1138 Ivy cwto zk me WWI nm OHM AD-PR-7006 PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE SITE INSTALLED FLEX DUCT/ SITE INSTALLED VENT CAP (SEE DETAIL 'A') SITE INSTALLED CENTER ,SECTION OF ROOF EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING FACTORY INSTALLED CENTER SECTION OF ROOF TYP. CONNECTION TO VENT FAN, SOLAR TUBE, OR EXTEND TO RANGE HOOD MARRIAGE WALLS EXTEND PIPE 3' ABOVE SHEATHING PLUMBING VENT (FACTORY INSTALLED) CEILING PANEL MARRIAGE WALLS SITE INSTALLED PLUMBING VENT PIPE (EXTEND 3- ABOVE ROOF) (SEE DETAIL 'B') FACTORY INSTALLED FLAT CENTER SECTION VENT CAP (OR SOLAR CAP) EXHAUST DUCT SPLIT AND FASTENED TO ROOF DECKING OR BACKER WITH MIN. 4- 81) NAILS IN LIEU OF FASTENING DUCT TO VENT CAP. SITE INSTALLED FLEX DUCT .y SHEET METAL SCREW 0-*-FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE (SITE INSTALLED) COUPLER Fq,A�(SITE INSTALLED) VENT PIPE 0-o-(FACTORY INSTALLED) DETAIL ' B' NOTES: tCONSTRUIlON 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS. BY Z SEE OTHER DETAILS FORROOF FLASHING INSTALLATION. 3. EXHAUST HOLE CUT DUCTIN MAYOF DBE RU . THROUGH EITHER A SOUARE OR ROUNDJUN4. RANGE AND BATH/AIR OUAUTY FLEX DUCTS TO BE SPLICED WITH ALUMINUM TAPE AS SHOWN IN THE DETAIL ABOVE. S. SECURE SITE INSTALLED PLUMBING VENT PIPE IN70 COUPLER WITH IN . APPROVED GLUE. D HOME ETY STANDARDS NO.nCE DRAWN BY: DAIS REV. LETTER: JACOBSEN HOMES THESESPEOMT06AMDRAMMsARE R.R. 01-23-04 COMM- PROPKIA", lulu WF10EMTYIL DRAWING TITLE _ M P.O. BOX 368 YATER1ALs a Y11NI1FACTPITCHED ROOF EXTENDED VENTS .Ic. sva rr<roass AREE PaovoED TO THE n[ SAFETY HARBOR. FLORIDA 34695 RECIMIT TOR S[CIIC RIIPM SO NMI K DRAWING NUMBER: PHONE (727) 726-1138 KEPT CMgEMIK AM SECRET "ONER& AD-PR-7007 26 SITE INSTALLED, SHINGLE AND UNDERLAYMENT FIELD INSTALLED 150 FELT MIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT 9111 A 6' MIN. OVERLAP AND A MIN. 6' WIDTH OF ROOF CEMENT. 150 FELT TO HAVE A 6' MIN. OVERLAP 15j FELT ALSO CEMENTED WITH A 6' WIDTH AROUND AND A MIN, 6' WIDTH OF ROOF CEMENT ALL PENETRATIONS OF THE UNDERLAYMENT AND THIS ALSO APPLIES TO ENDLAP SEAMS. PERIMETER OF ROOF. I -1 r r' -1 r 1 r -1 r--II ~ FIELD INST&M ROIi SHEATHING (lYP•) I 6' WIDTH OF ROOF CEMENT WHEN LEDu I f 11 I OPTIONAL 15f FELT IS INSTAL. us r� � t OP110NAL LAYER OF 15E FELT Ls r I ONE-PIECE SHINQE UNDER/11NEM ROOF SHFARK (TYP.) THIS ROW OF SHINGLES TO BE FIELD INSTALLED AFTER THE UNDERLAYMENT HAS BEEN INSTALLED. THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DECIONG FOR UNDERLAYMENT OVER LAP OF 6' MIRMUM. TO TO 3' 3' a FASTENING DETAIL WINDZONE t (110 MPH) ALL EXPOSURES NOTES: uwjwscn rrrRurn; unrn, wrrnvr,uZ 1. CEMENTING OF OPTIONAL 15/ FELT IS NOT REQUIRED IN ANY AREA APPROVED BY EXCEPT WHERE NOTED. Revised 2. FASTENING OF OPTIONAL 15f FELT IS NOT REQUIRED. (FASTENERS APPLIED �RE Oct 29,2007 ARE JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) �Oh7 I✓Q^�dvn� INC. 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS K2 F-ng:i ic-04ig, Ina, NSTRDERK MONMANUAND SAFE note NSTRUCf1DN AND SAFETY STANDARDS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. JACOBSEN HOMES "°MI n� �1G11t>t15 Alo DRIINNS ME ORAWN 9Y: O.A. OAIE 10-24-07 R,�►.IETTER: OR ox. PROPR umx AN0 CD]ii mm MAXIMS OF wwxlnm DRAIM TITIfi: SH?I U AND UNDE%ArmOT A P.O. e0X ma Pt 9NA MATERKS ARE PROM TO m SITE IWALLED SAFETY 95 I1RAwrr� NUH P ONE ( ) 72266-D 138 IMP�`t°1fmR T U MID FUN O m+� AD-PR-7008 ol TYPICAL FLASHING INSTALLATION ROOFING TAR UNDER NAILING FLANGE AT ALL FASTENERS TYPICAL SHINGLE ROOF " h/ ROOFING TAR APPLIED OVER TYPICAL FIELD INSTALLED RAFTER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. .105" X 1' MINIMUM ROOFING NAILS OR .113" X 1' MINIMUM NAILS MAY OPTIONAL SHINGLES MAY BE APPLIED TO BE USED IN LIEU OF STAPLES FOR FASTENING FLASHING TO ROOF. COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA WITH ROOF— ING MASTIC (TAR). OPT. SOLAR TUBE INSTALLATION TYPICAL SHINGLE ROOF SOLAR TUBE DOME, WITH NAILER FLANGE, SECURED TO ROOF, ON TOP OF UNDERLAYMENT, AND TOP OF FLANGE UNDER SHINGLES. NTH BOTTOM OF FLANGE OVER SHINGLES (BOTTOM FLANGE MAY BE COVER WITH SHINGLE TABS SECURED WITH AN APPROVED CAULK). TUBE SUPPLIED BY SOLAR TUBE MAN. NOTES: DAPIA APPROVAL: 1. ROOF FLANGE FASTENED TO SHINGLE ROOF WITH RAIN. 1- X T- X 16 GA. APPROVED BY STAPLES 6" O.C. (SHINGLES APPLIED UNDER LOWER END OF FLANGE). INC. FEDE ALMANUFACTUREDHOME Cotis RUCTION AND SAFETYSTAI•EIARDS JACOBSEN HOMES Nonce T►csc SPECl1GTKiMS AID oRAWNGS ARE DRAWN BY: M. T. DALE 02-04-04 REV. LETTER DRAWING TITLE- UKK4 , MWKIART: AND COII10ENRq ,I P.O. BOX 368 rAURLILS Or JKOBS I MANUrACTUFACTYP. IIG SUCH YATERULS ARE PROVDm TO 1IE FLASHING INSTALLATION SAFETY HARBOR, FLORIDA 34695 RECPEMI FOR SPCOIC PWPOSES AW MIST K DRAWNG NWKR: 171 PHONE (013) 726-1138 IXPT CpW1DEMIX AM SECREI RIOT OILERS AD-PR-7009 28 ADDENDUM GENERAL 'NOTES / TIE-DOW"NS NOTES: 1. FRAME TIE —DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE —DOWNS ARE REOUIRED IN ADDITION TO THE FRAME TlE—DOWNS. 3, VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE—LOW'NS WHEN A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING. W -L ANCHCfcS ARE NOT INSTALLED AT THE ANGLES) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE ;NSTALLED IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME TIE —DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SUPPLIED BY OTHERS). 5. VERTICAL TIE STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HOMES FOR ATTACHMENT OF VERTICAL TIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF THE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH A MIN. OF 0.30 OZ. OF ZINC COATING PER SQUARE FOOT OF STEEL ri DESIGN BASED ON 95 1/2' I —BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0' (82' I —BEAM SPACING IS ACCEPTABLE FOR 10' WADE SECTIONS OF MULTI —WIDE UNITS W/ 9T SIDEWAL.L HEIGHT ONLY). 9. LONGITUDINAL DES SHALL BE INSTALLED ON THE INSIDE OF EACH I —BEAM AT THE CROSS —MEMBER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 1 AND 16. 10. FRAME TIE —DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN I —BEAM (AS SHOWN ON TIP. CROSS—SECTION DETA4S) AND SHALL COME OFF THE TOP FLANGE OF THE I —BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO THEIR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL TIE AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION R0 TYPE OF SOIL IN WO THE ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST If ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROHDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES. 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. 15. ALL GROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER. VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXMUM OF TWO LONGITUDINAL TIE —DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS —MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE —DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS — MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE —DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS —MEMBER TO WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE AFPROPRIATE TABLES FOR THE REQUIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE —DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET—UP MANUAL AND ADDENDUM FOR BLOCKLNG P,EQUiRELIENTS. ALL BLOCKING DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES OT S' "wnux rTUT i THESE NOTES AND DETAILS ARE APPLICABLE FOR WIND ZONE II AND/OR WIND ZONE III. THEY — ENE8703571 ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' = .� AND EXPOSURE V. SEE APPROPRIATE TABLES FOR SPECIFIC INFORMATION ON EACH. •.TAI¢ NOTIO+ JACOBSEN HOMES •'�4,p TT THESE SPELIT1CA110115 AND DRAwNLS ARE OHEOINAL. PROPRIETARY, AHD CONTMTVL EIRAMIN ,. P.O. BOX 368 MATERIALS OF ,IACOBSEN YNWAC1LRINC SAFETY HARBOR, FLORIDA 34695 HNC SNT MATERIALS ARE PRONDED To THE REH,pDlT (OR SPECIFIC RFPO45 NO IE151 BE DRAWN PHONE (813) 726-1138 KEPT COWIDEE)IM AND SECRET TRW OTHERS C.L.Y. E D BY /a, JM 1 5 T INC. OHM ffnnq&m REV. LETTEA 5-19-95 TD-GENERAL NOTES A AD-TD-0001 29 ADDENDUM NORMAL TIE -DOWN SPACING TABLES Ott & 1 ZONE II & III/EXP. C & D Z j LONGITUDINAL TIE -DOWN SPACING TABLE \r' MIN. WIND ZONE II WIND ZONE ill V FLOOR SIN• On ANCHOR MIN. OTY. ANCHOR WIDTH EA END O AN. EA. END OF ANGJ EA. gCTION YIN. B EA SECTION MIN. B �4 20'-0' 2 36' 2 45' 1 24'-0" 2 46' 2 60' 25'-42 50' 1 3 38' 26'-8' 2 54' 3 41 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN MAX VAND ZONE n WIND ZONE III FLOOR EAVE Del.. NERD ANCHOR HEAD ANCHOR ANGLE SPACING DEL ANGLE SPACINGANCHOR WIDTH OVERHANG LOAD 20'-0' 12" 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 24'-O' .12' 8'-0' 3150# 40'-50' 6'-8' 3150# 40'-50' 25'-4' 12' 8'-O' 31501 40'-50' 6'-8' 31501 40'-50' 26'-8' 12' 8'-0' 31501 40'-50' 6'-8' 3150 40'-50' LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WAND ZONE III Y. ANCHORMINOTANCHOR FLOOR Ek END ANGLE EA. END OF ANGLE WDTMEASECTION vim. B EASECXN MIN. B 20'-0' 2 50' 2 68 24'-0' 2 70' 3 50 25'-4' 3 45' 3 60' 3 60 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WAND ZONE II WAND ZONE Hf FLOOR EAVE DBL HEAD ANCHOR ANGLE SPACING �- HEAD ,WOO ANGLE WIDTH OVERHANG SPACINGG LOAD LOAD 20'-0" 12" 5'-4' 31501 40'-45' 4'-0' 3150j 40'-50' 24 -0' 12' S'_4' 3150e 40'-50' 4'-0" 3150# 40'-50' 25-4' 12' -4' 31501 40'-50' 4'-0' 31501 40'-50' 26'-8' 12' S'-4' 31501 40'-5O' ,w 111111IT '-0' 31501 40'-50' ENGNEER �i�� DAPIA APPROVAL• NOTES: `� 1. SEE AD_TD-DOOI FOR ADDITIONAL REQUIREMENTS. ;;�'G No.RFO'!L PPROVED BYE 2. SEE AD-M-0011 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS _ ENE8 5 TABULATED AB04E. --, ,�••. .� � fE7ENlWwIf�C1URIDN7E O I A+ . • G\ �.� ous+u�ono sArm swa+IDe NOTICE: 1CR1M:1!! •• DATE: REV. LETTER: AT JACOBSEN HOMES THESE snanCONs AND DRAwNCS ARE C.L.Y. 5-30-95 ■ MONAL. PROPWETARY• AND CONnDENTLAL DRAWING TITLE: MATERIALS OF JACOBSEN UANORM. SPACING TABLES A P.O. BOX 368UFACTURIHG „ INC.NCSUCH YATERULS ARE MmD D TO THE SAFETY HARBOR. FLORIDA 34695 RECIPIENT FCR sPEcFX PUvasES u0 WJST BE DRAWING NUMBER PHONE (813) 726-1138 PUT CO16Mnk Alm SECRET FROM OTHERS AD—TD-0010 30 ADDENDUM ALTERNATE TIE -DOWN SPACING TABLES l o ZONE Il & III/EXP. C LONGITUDINAL TIE -DOWN SPACING TABLE MIN. VEND ZONE u W1ND ZONE III (v. RM WL 0. EA. ANIM AN. lK on FA Dm OF AN o M6lE WIDTH SEC IN EA. sDCTnIt IDI. a EA. SDCA011 YN. e lif 23'-4' 2 54' 3 40' �0 24'-0' 2 54 3 40' 25-4` 2 w 3 44' 26'-8' 3 38' 3 48' 4T 4 41' (SEE NOTE 14 FOR ANCFIOR ANGLES) VERTICAL TIE-DOW / FRAME TIE-DOW SPACING TABLE MIN, MAX WIND ZONE II WIND ZONE @I SPAM W mom ma SPAl7NG n ANM AM EAYE IILOO OVE(WANG 294 12' 54 3150E 40=45' 5-4' 3150f 351-C 24'-0' 12' 5-4' 3150E 417-W 6-4' 3150E 35'-40' 254 12' 51-4' 3150E 40'-4S 5'-4' 3150f• 3.7-C 12' T 4' 3150E 40'--45' 5'-4' 3150E 35-40' 12' T 4' 315Df W-45' 5'-C 3150f 351-C (SEE NOTE #4 FOR ANCHOR ANGLES) Oaeee916iit!!!!�°0 C.• DoF, °O�9 v • No 45484 '• v. ze• J - O `° o O t 8TA�._ �' �m REF. CALC. ..A C-TD - 215.01 - 215.20 OR I �� S • •....... .,1E9 e °°01ssONAI- ,`eo NOTE$.. FN0M APPROVAL: DW Al"DWAL: 1 SEH AD-TD-COOT FOR ADDHIONAL BEQIMMOITSI APPROVED BY 2. g:E AD-1D-0011.1 FOR YA)OIGRI PER HM73 REOM FOR THE I= un 16,2009 PJIN TAIIAATED ABM THIS PAGE APPUCABLE TO DOUBLE UB ONLY. N1 C 3. TE-DOLMi DESRi1 ON . 4. ma ANOHat ANGLE SHOWN IN THE OW ABOVE CANNOT BE ACHIEVED, FEDERAL YANUFAGTDRfO NOSE CONSi1 UMON AND SAFETY STANDARDS 06TALLFD AN APPROVED STAMM PLATE JACOBSEN HOMES 1M5�� DRAM PX DRAVN BY.. T. DATE 06-04-09 REV IETRR oRA G "ALTERNATE SPACING TABLES MA°UM s Of c — P.O. BOX 361 SAFETY HARBOR, FLORIDA 34695 W. = VAIERL S ARE FRDM 10 TIE RD W FM SPEC RUM AID US 9DRAWIG MKT Floats MWK MAKIt AD-TD-0010.1 PHONE (813) 726-1136 ITT COMM ND 31 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM FIGURE 1.0 SEE FIGURE 2.0 FOR ALTERNATE TIE-DOIFN IMOD FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE TIE-DOW .YE A SEE NOTE 5 FOR MAXI0 HWT NOTES: EHaREER`�RPRw\ovAE QQ�-Oi�''�,� .,QgE�►},(�'�1�Y4-•BV 1. SEE AD-TD-0010 FOR SPACING TABLES. N� iFiV V CU i 2 SEE AD-TD 0010 FOR WARTY OF LONCITUOIAL ME -DOWN STRAPS REWIRED. • •Q' •• 3. SEE OTHER DUALS FOR BLW014G (PIER) QUANTITY AND OTHER REOUG2EIAENTS. _ ENE8703571 INC4. SEE AD-TD-0001 FOR ADDIRONAL REQUIREMENTS. - 1 W 5. ZONE 2/DPOSURE 'G: 60' MAMMUM HEIGHT $ d AlIL1�lAlOSAFE7TiTNpR ZONE 2/EWMRE *0': 44' MA)MM HEIGHT :'pO••• / 7 P • a� REF. CALCS ZONE 3/EXPOSURE *e' 40' MAXMUM HEIGHT �ii • . p�_.•''�� ��� ZONE 3/EIPOSURE V: %" MAMIUM HEIGHT JAC O BS E N HOMES THESE SPECNICA771ONS °" T �` DATE. REV. LErrER AND DRAVOWS ARE C.L.Y. 3-27-95 ORIGNAL PROPMETAFM AND MOIDENTIN. DRAWING TITLE' rDpF P.O. BOX 368 MA70UM OF JACOM MANIFACTUtMIG FIGURES 1.0 AND 1.1 HG SUCH MATERIALS ARE PRQNDED TO THE SAFETY HARBOR. FLORIDA 34695 FUPENT Fat SUFE RFPM AND MUST K DRAWING NUMBER: PHONE (813) 726-1138 WT CONFWUOL AND SE ET FRW OTNEM AD-TD-0011 32 ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS FIGURE 1.0 TYPICAL CROSS SECTION I I MOWING TIEDOWNS• FLaaa TTF: mm ma (a NGTE 08) MOM MIRE (sfE KIM 18) FIGURE 1.1 MaM FI M ON 95 ilf I—SM ems #0 95' M SMAU) e ee�peCacDO s®� 0 NOTES: APPROVED BY 1. SEE AD-1D-0010.1 FOR SPACING TABLES 2 SEE AD-TD-0010.1 FOR QUAILITY OF IONGII= TIE-OOL6L STRAPS REOIARED, 1SEE OTHER DETAILS FOR BIACIONG (PIER) QUANTITY AND OTHER REQUIREMENTS sim 16,2009 INC. 4. SEE AD-TD-0001 FOR ADDIRONAL REQUIREMENTS FEDEWN. KOLFACRWD HOME 5. ZONE 2/E10OSIJRE OR : 670 MA)MIJN MW CONSTRUCnON AND SMTYSTANMNDS ZONE 3/EIQ MK V: 58' MUM HWIT 6. µtEN ANCHOR ANU SHON ON AD-TD-0010.1 CANNOT BE ACf8M REF. CAMS: INSTALL AN APPROVED STARLM PLATE. GTD- 215.01 - 215.20 NOTIC& DRAWN BY: DALE MY. ie I M JACOBSEN HOMES 7Nw7m Aw mAwm Am M.T. 06-04—os MM ROPEETMRY, AID OONImO= DRAWING TILE' NATR U OF d ZMM HANUFAC ING FIGURES 1.0 AND 1.1 P.O. BOX 368 ¢IG SUCH YATIR= ARE MOM TO 71E SAFETY HARM, PHONE ) 726-1DA 1138 95 mm I'm gm WT CMWAL AM MU OI G�mBtsE. DRAWLNi NUMBER: AD—TD-0011.1 00 12-2 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR uw.OTY. ANCNOR MIN.OTY. MOOR WIDTH EA. END Of EA. END OF ANGLE V EcncN A � IN. MIN. a EA SEcncN MIN. e 12'-0' 2 43' 2 55' 13'-4' 2 50' 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANDiOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 8'-0, 31501 40'-50' 6'-8' 3150# 40'-50' 13'-4' 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WND ZONE III . FLOOR OTT. ANCHOR YIN ANCHOR WIDTH k E EA. END OF DOTY.O EA. END Or EA SECTION IN. YIN. 6 EA SECTION MIGLE N. MIN. A 12'-0' 2 64' 3 47' 12'-0* 3 37' 4 33' 14 3 42' 3 55' 4 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL. HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANOHOR ANGLE FLOOR WIDTH EAVE OVERHANG 6' 5'-4' 31501 40'-45' 4'-0* 3150-1 40'-50' 13'-4' 6' 5'-4' 315011 40'-50' 4'-0' 3150 40'-50' NOTES: ENQNEER% �•'// D DAPIA APPROVAL* 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS.•''�gT APPROVED BYE. Z SEE AD-TD-0013 FOR WXLIUM PIER HEIGHTS REOUWED FOR THE LOADS No. ' 5 rAelllaTED Aso�E ENE8703571 — 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIXINALL NOT FRONT OR REAR. * ' NIP INC 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS ►ITH 95 1/2' �. STATE F ? � � �,FA tC SII�:7p1AOSA1{IYSWGfLO I -BEAM SPACING 96' MAXIMUM 9DEWALL HEIGHT AND 6' MAX WW SIDE OVERHANG (6' OVERHANG MAX EACH SIDE Of UNIT). •�`,; ' �/`/� i��� �+ •'•....... (� ``� JACOBSEN HOMES NOTICE: �Ah!! HI nam sECIFICAT*is AND ORAMNM Aw �C 11LLd ' C.L.Y. DATE: 5-30-95 REV. LETTER: P.O. BOX 368 m OiDONAL. PROPKUAY. AND OONnO(NTWL MATERIALS OF JACOBSEN MAWFACTLRING INC. S" MAXFMS ARE PROWED TO THESAFETY DRAWING TITLE: NORM. SPACING TABLES FLORIDA118 CP "FWD OP�PP DRAWING NUMBER: PHONER(613) . KEFT U FKU OTSh� AD-TD-0012 34 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM FIGURE 1.2 SO FIGURE 2.0 FOR ALTERNATE TIE-DOW iMD ;vim ANGLE FIGURE 1.3 SEE MUM 7.0 FOR ALTERNATE TIE--DDiN MWID SEE NOTE 5 FOR UA= HOf4HT ENaNEER omboll os: ' DAPIA APPROVAL ��`� C. DOF 1. SEE Ao-TD-0012 FOR SPACING TABLES AND NOTES ��• O -,� APPROVED BY,, 2. SEE AD-TD-DD12 FOR QUANITY OF LONGITUDIAL TIE -DOWN STRAPS REWIRED. �O; ��G`STEgF . �� •� 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REOUREIIENTS. Q` N0. O0 JAN •i I EN 870357 - 4. SEE AD-TD-0001 FOR ADDITIONAL REQUREUENTS = = IA I� 5. ZONE 2/EXP=RE 'C': 30' MAXIMUM HEIGHT - - I v ZONE 2/EXPOSURE '0•: 48' MAXIMUM HEIGHT A ^ OF rwcwar+n�fciu�iaE ZONE 3/EXPOSURE •C•: 28• MAXIWUU HEIGHT :• �� •�� '�110M"1D a A ZONE 3/EI(POSURE '0': 60' MAXIMUM HEIGHT ��i!`••• DiA� ' �� `�` NOMCR i� •N l� Ar DATE REV. LETTER: THE%sKancATI0Ns Am oRAldrb "qll TLC,`% C.L.Y. 5-19-95 JACOBSEN HOMES OMMAL. PROPRIETARY. AND OMFUNT1AL DRAWING RTLE „ P.O. BOX 368 MATQtIAIs OF .MC1)M MANUFAC1U 0 FIGURES 1.2 AND 1.3 ARE PRM(D 70 DIE - A SAFETY HARBOR, FLORIDA 34695 Of FGR 9M PUSS NO WET K DRAWING MJMBER: PHONE (813) 726-1138 IVT CWKNTK AND MM FROM 0MR& AD—TD-0013 35 ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS MAX PER AD-ID-WIO IME mx w-IU-wlO iAaL rLX w-W-wiu MILL ruc w-iu-wIu 1� FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS -SECTIONS) NOTES: Q�' ��STER' •:c�,L 1. SEE AD-TD-0010 FOR SPACING TABLES •' F� N 0 • F� ' 2. SEE AD-TD-oo10 FOR OUARTY OF LONGITLINAL TIE-DOAN STRAPS REWIRED. ENE3703571 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REOU MENTS. _ �6'_ 4. SEE AD-TD-0001 FOR ADDITIONALREQIAREUENTS. JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 ,,,,, A LTT0°� NOTICE: DRAWN BY. C.L.Y THESE SPEonCATICNS AND DRANNCS ARE ORIIANAL. PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE.• MATERIALS OF JACCBSEN MANUFACTURING INC. SUCH MATERIALS ARC PROM D TO THE RECIPIENT FCR SPECFIC P,PP00 AND (LUST BE DRAWING NUMBER OUT CONFIDENTIAL AND SECIV FROM OTHM DAPIA APPROVAL, APPROVED BYE ocoppla- � � 5 INC, FEMM YAMfI MM NME W'6TFWCHN0SffTT5PM= DATE: 5-19-95 REV. LETTER: FIGURE 2.0 A AD—TD-0014 36 ADDENDUM ALTERNATE TIE -DOWN SYSTEM(S) ALTERNATE LONGITUDINAL TIE -DOWN INSTALLATION METHODS SIDE VIEW OF MAIN FRAN_ TI_-DOWN STRAP SCE OTHER DETALS FOR RE -DOWN STRAP SPECIFICATIONS. APPROVED ANCHOR WELDED TO WAIN I -BEAN (SEE OTHER aEW3 SEE AD-TD-0200 FOR FOR WELONG) 70 BE INSTALLED RADIUS CLIP DETALS AT K FACTORY. (REQUIRED THIS LOCATION). (MIN. 31501 WGRANG (D"SIGN] LOAD AVD 47251 ULTIMATE LOAD.) o° GROUND ANCHOR SEES OTHER DETALS FOR SIZE, ANGLE AND OTHER INSTALLATION NOTES FIG URE 2.1 SOLID HEADER (CROSSUEll8ER) 3* X 3/4' (i 1/2) FRONT VIEW . MUST T BE LOCATED CUT INTO HEADER CAT FOR STRAP ATTACWEIIT. WiMUSTHIN S' OF MAIN (FACTORY CUT) CHASSIS !-BEAK F� SEE AD-ID-0200 FOR j .SEE AD-M-C200 FOR RADIUS CLIP DEMLS (REQUIRED THISTIOCATION). I (REQUIRED THIS LOCATCN). —1 5'MAX. TIE -DOWN MAP SEE OTHER DETAILS SIDE VIEW FOR TE-DOWN STRAP SPECMCATWS. GROUND ANCI,OR' o SEE OTHER DETAILS FOR SIZE, ° ANGLE TWO OTHER MiSTAL ATION NO =5. ;% FIGURE 2.2 NOTES: L%gRU.R APPROVAU::1e1. .' y DAP:A APPROVAL" = E NEER 772I. SEE AD-TD-0010 FOR SPACING TABLES 2. SEE AD-TD-OOIO FOR OUANITY OF LONG17UOIAL TIE -DOWN STRAPS RLDJ:RED. I SEE OTHER DETAILS FOR BLOCKING (PER) QUANTITY AND OTr1ER REWREAIENTS. „ �i� • �f r (� •; H. SEE AD-TD-0001 FOR ADDRANAL REWRENENTS AL �rrrr,lN1„1,Vr„� - AKCHOR BRACKET AND TL-COM DD ICES ARE CERTIFIED BY OTTERS JACOBSEN HOMES -� T�OSAN3 TrTi3 S4CGFICA`OHS AN] CRAfIl,OS AfiC C.L.Y. OA i�. 6-13-55 FEV. rmR: FORA71L. nCURES 2.1 & 2.2 W-4AL FRL- TART. AN] CDJUN U1t MAMULS o dAcoegX mm"AtTuitic P.o. aox 36B NG SUCH MAMMS An rM1o►ITEO TO Tw UVIBM* AD— TD-0015 SAFETY HARBOR.FLORIDA 34695 maRoa ra s[au rjwm #a MAY E Oita PHGVE (813) 725-113E earl MnZi lk NO MOU — 37 ' LONGITUDINAL STRAP ATTACHMENT TYPICAL FRAME I -BEAM CATOR BEAN CLAMP, MANUFACURED BY TIE -DOWN ENGINEERING, PART 159011 (SEE MANUFACTURER'S INSTRUCTIONS FOR COMPLETE INSTALLATION DETAILS) TYPICAL LONGITUDINAL ANCHDR STRAP (FIELD INSTALLED) NOTES: ; DAPIA APPROVAL I. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS AF PROVED BY 2. ALL -STRAPS TO BE TYPE 1, FINISH 8, GRADE 1 STEEL STRAPPING, 1 1/4" WIDE ow 00T4ft", AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTPROFESSIONAL ERED JUN 15 . m ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. ' N C. FEDE AL MANUFACTURED HONlE CON RUCTION AND SAFETY STMDARCS N�m •JACOBSEN BIOMES THESE SPECIFICATIONSANDDRAWINGS ARE DRAWN BY: M. T PATE; 6-12-01 REV UTTER. CRIGINAL, PROPRIETARY, AND CONFIDENnAL DRAWING TITLE: — P.O. BOX 368•MATERIALS OF JACOBSEN MAlNUFACMINC SAFETY HARBOR. FLORIDA 34695 INc SUCH NAMMALS ARE MOMDED 10 THE LONGITUDINAL STRAP ATTACHMENT RECIRENT FOR 9W PURPOSES AND MUSE BE DRAWING NUMBER: PHONE (727) 726-1136 FET R:ORRDOMAL AND SLQ0 FROM OTHERS. AD- TD-'0016 38 ADDENDUM S�''' �.z OFFSET UNIT TIE -DOWN SPACING TABLES ZONE II & III/EXP. C& D c � I LONGITUDINAL TIE -DOWN SPACING TABLE F+1 MIN. WIND ZONE II 1MND ZONE III A. D Y.O EA. 0' ANCHOR ANGLE AU1 D Y.O EA, END 1O! MGM ANGLE ANGLE FLOOR O WIDTH SEC EA SECTION NRL a EA. SECTION NQL e 10'-0' 2 44' 2 56' 12'-0' 2 57' 3 42' 13'-4' 1 3 1 38' 3 50' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBI ANCHOR ANGLE SPACING DBOADLL ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG 10'-0" 12" 4'-0' 31501 40'-50' 4'-0* 31501 40'-50' 12'-0" 12" 4'-0' 3DO01 40'-50' 4'-0. 31501 40'-50' 13'-4" 12' 5'-3' 31501 40'-50' 4'-0' 30001 40'-50' LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE it WIND ZONE III Wa• OTT. EA. END OF ANCHOR ANGLE MIN. OTT. EA. END IF ANCHOR ANGLE FLOOR O v WIDTH Eti sEcnoN w+. a Eti s,:cTIDN ulK e 10'-0' 2 64' 3 46' 12'-0' 3 50' 3 68' 13'-4' 3 58' 4 48' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE, MIN. MAX. WIND ZONE II WAND ZONE III SPACING HE oa HEM ANCHOR ANGLE SPACING DBI. ► EAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 10'—O" 12' 4'-0' 31501 40'-50' 2'-8" 31501 40'-50' 12'-0" 12' 4'-0' 3100g 40'-50' 2'-8- 31501 40'-50' 13'-4" 12" 4'-0' 3065,9 40'-50' 2'-8" 3000j 40'-50' ENGlNW"VAb ll A NOTES: F� jfkt5V'�D BY 1. OFFSET SECTION 161TH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDWALL OF ,•' G\S T �tj ,, ,� •Q� �'' C� •'•_ REVISED THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE UNE DN ACCORDANCE THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE TO: S;�P 0 9 1 WI iH THE TABLES ABOVE ; \ BE TIED DOWN IN ACCORDANCE WITH THE NORMAL SPACING TABLES (AD-TD-DO10). ; ► 2. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS. �4,r;'•,in9(g6r.•' INC. HOME FED J. SEE AD FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULAlEO F. ,•�L'�1A1�• .• ��`�� • ����� '�G�`��� CO RAL MANUFACTURED STRUCTION AND SAFETY STAND ABOVE �j's .... • JACOBSEN HOMES NOTICE: DAIS REV. LETTER: xSE SKanCATMS Afro DRAWNGS ARE R.R. 8-27-96 vOrJATO AND DRAWING nTLE:OFFSET B MATMA N Y NUFACMIC MATERIALS TO SPACING TABLES P.o. BOX 368 SAFETY HARBOR, FLORIDA 34695 AT RIALS A TKE DIG. SU01 MATERIALS ARE FRONDED i0 IHI OMM REOP01 RR 7ECIIC FlAWM AND VAT BE DRAWING NUMDER CROP OD(1K AD—TO-0020 PHONE (613) 726-1138 PVT C*VMNnX No SECRET DS. 39 ADDENDUM, OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE TIE -DOWN METHOD TYP. CROSS SECTION(S) SHOWING TIEDOWNS SEE NOTE 5 FOR MAXDNu NEIIIIT Alof ANGLE FIGURE 3.1 SEE FIGURE 6.0 FOR ALTERNATE TIE-DOVN METHOD NOTES: 1. SEE AD-TD-0020 FOR SPACING TABLES (OFFSET SECTION ONLY). 2. SEE AD-TD-0020 FOR OUANITY OF LONGITUDIAL TIE-DOVIN STRAPS REQUIRED. (OFFSET SECTION ONLY) 3. SEE OTHER DETAILS FOR BLOCIANG (PIER) QUANTITY AND 01HER REQUIREMENTS. 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. 5. ZONE 2/EXPOSURE 'C': 44' MAXIMUM HEIGHT ZONE 2/EXPOSURE 'D': 24' MAXIMUM HEIGHT (32' 0 24' WIDE MIN.) ZONE 3/EXPOSURE 'C': 32' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'D': 32' MAXIMUM HEIGHT (44' 0 24' EDE MIN.) [TABLES ON AD-M-M MIDI APPLY TO TUPSE STANDARD MlITI-W E SECAONS OF THE UNIT -SEE NOTE 1, AD-TD-0020.] TYP. FLOOR SYSTEM--7 ANCIFOR ARCLE TYP. FIGURE 3.2 1F9tldItE'g.!lNBQ�� ALTERNA7E 17E-DOWN METHOD Om • O �i� DAPIA APPROVAL• p • G\STE,q O APPROVED No. `� - OVED BYE • ENE8707NTf 4INC 3571 - r �((� '•����c� ``��� CGNSi�MIG7�N0�S1ff1T FE=THE$ JACOBSEN HOMES x°TIc Si'EC1FlCAnops AND DRAIMNGS ARE DRAWN BY: C.L.Y. DATE 5-11-95 REV. LETTER: P.O. BOX 368 ORIGINAL, PROPRIETARY, AND CONFIDENRAL MATETtIALS OF JACOBSEN MANUFACTURING DRAWING TITLE FIG. 3.0, 3.1 & 3.2 SASTY HARBOR, F7261D1384695 IK SUMNATERIALS ARE PROMDED TO THE C HM DRAWING NUMBER HONE (813) KWT CFI AM SECT rMM AD-TD-0021 40 ADDENDUM ALTERNATE OFFSET UNIT TIE-DOtitiN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE—GOAy SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION ,111111111111,//� NOTES `Fj� � OV • i. �i��OAPIA APPROVAL• I. SEE AD-iD-0020 FOR SPAC_4 , TAKES (OFFSET SECTION ONLY). ` O �P% IN oER�O . APPROVED BY 2. SEE AD-TD-0020 FOR QUAN17Y OF LCNG17UDIAL TIE-DOBH STRAPS REOIRRED. � L (OFFSET SECTION ONLY) = NE8703571 5 3. SEE OTHER DETAILS FOR &00r-.4G (PIER) OUANTITY AND OTHER REOUIRElQHTS.:_ ' 4. SEE AD-1D-0001 FOR ADDIMNAL REQUIREMENTS T TV.: Q I N G °,���,.�f14 *A �aN�..•� ,. (001RIC�4�MOWi11ei1K•11otawammmAomw q JACOBSEN HOMES No"cr "" TMESF s�onunoNs ANo oRNts ARE AU Ulf. C.L.1. DATE: 5- 11-95 RU LEnut P.O. 90X 368 SAFETY HAP-:R, FLORIDA 34695 PHONE (813) 726-1138 MUNI Im MAXIMS ARE PROGIEC1-1. PRM TO AND CCNIIDENIYL MATERIALS OF JACOOSDI uAKrACwug w- 01DIE RIC1 W FOR 9'(Crt RRFCSB me MAT ec 1®T Chilo PX NO MOV 1K11 OTC& /—` . „ DRAwwG not AG. 4.0 DRAW NG NUMBER AD—TD-0022 41 R ADDENDUM C��gS s ALTERNATE UNIT TIE-DOIM SPACING TABLE it ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE E+' MIN. WIND ZONE 11 WIND ZONE III NK OTY. FLOOR YIN. OTI EA. ENO Cf ANCHOR ANGLE EA. END O ANCHOR ANGLE WIDTH EA SECTION YIN. A EA SECTION YIN. D 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 1 254 1 2 50' 1 2 67' 30. VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING ffA D OAD ANCHOR ANGLE SPACING DErL HEAD LOAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG 20'-0' 12' 4'-0' 36701 20' 4'-0' 3900# 20' 24'-0' 12' 4'-0' 37001 20' 4'-0' 3950# 20' 25'-4' 12' 6'-8' 40001 15' 4'-0' 3950# 22' 26'-8' 12' 6'-8' 39501 28' 4'-0' 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE nl G\ FLOOR ION. OTT. EA. END ON ANCHOR ANANGLEEA. UK OTY. END OF ANCHOR E WIDTH Ell SECTION UK EA. SECTION uKIN. D 20'-0' 2 50' N/A N/A 24'-0' 2 70' N/A N/A 25'-4' 3 42' N/A N/A 26'-8' N/A N/A N/A N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHORANGLE FLOOR EAVE OVERHANG Low 20'-0' 12' 4'-0' 40001 20' N/A N/A N/A 24'-0' 12' 4'-0' 40001 24' N/A N/A N/A 25'-4' 12' 4'—O' 40001 26' N/A N/A N/A 26'-8' 12' 4'-0' 40001 27' , ,,,,, , N/A N/A N/A NOTES: ENCI?gf •APP�'�DO.//�j rlG\ DAPIA APPROVAL' I. SIT AD-16-0001 FOR ADDITIONAL REQUIREMENTS ^0- _ 2 SEE AD-TD-0031 FOR MAXIMUM PIER HEIGHT REQUIRED FOR THE LOADS TABULATED ENES703571 ': = ;-� --• ? ABOVE: 3. 20 WOES -82' MAXIMUM I -BEAM SPACING ONLY. 4. 4' MAXIMUM INSET TO ANCHOR HEADS (SEE AD-TD-0031). �.� >.� '• 11/" \ . - . JACOBSEN HOMES NOT1Cl: nr TNEsE snanc�Tm AND DRAwNEs ARE e9RAwNN' C.L.Y. DATE. 6-13-95 REV. LETTER: DRAI'ANG TIM ALT. SPACING TABLES OEONAL PRWKIARY, AND OONn0E RAL MATERIALS OF JACOBSEN MMWACARNG P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 INC 91DI MATERIALS ARE PROVIDED TO PiE REaPmIT rcR spccne tir+P m Ab wAT m ORAMNG NUMBER: AD— TD-0030 PHONE.(813) 726-1138 UT cowm n4 No SE00 FEW ones 42 ��p�pg5 �000� ALTERNATE TYPICAL CROSS SECTION SHOWING TTEDOWNS ADDENDUM TIE DOWN SYSTEM(S) $ NOTE 4 FOR MAWN HDmT 4' MAX J FIGURE 5.0 SEE FIGURE Ll FOR RECOMMED 'TIE-DOT,1 1BMD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIFrDOWN COh'FTGURITION A STYLE CREST PRODUCTS MODEL 57SH (TYPE 21 AUGER ANCHOR ills{ A DESIGN IDAD (iOREING LOID) RATING OF 4,000 POUNDS AND AN ULTIMATE LOAD RATING OF SADO POUNDS UU57 BE USED. AN EQUIYILAHT ANCHOR MEETIRG THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN 11EU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN I. SEE AD-TD-0001 FOR ADDITIONAL P.EOUIREMENTS. ALL WIND 20NES AND IN BOTH EXPOSURE 'C' AND EXPOSURE V. HOWEVER. BY INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' 1-BEAN THE YAK 2. SEE OTHER DETAILS FOR BLOCIGHG (PIER) OUAINRTY AND OTHER REOUIREMENTS. HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 5.0 SEE ALTERNATE LE -DOWN SPACING TABLES (AD-TD-0030). RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. 4. ZONE 2/EXPOSURE 'C': 3TC MAXI-LIM HEIGHT EHCtNET7i,APPROVALy1.- ��,. OAPIA APPROVAL ZONE 2/EXPOSURE b': 27: MAW.JM HEIGHT ��` N VL ''iS� ZONE 3/EXPOSURE'C': 30' MAXILfJM HEIGHT1STE ZONE 3/EXPOSURE 'D': THIS APPLICATION ��� IS NOT APPLICABLE. �= ��C N0� r 1 7 1 JACOBSEN HOMES NOTICE "' I"' THESE SPEGnrAnON5 AND DR AAE ' ORAWN BY: C.L.Y. DATE 6-13-95 REV. LETTER: m P.O. BOX 368 OMOINAL. PROPMETARY, AND CON►10f TK MATERIALS OF JACOBSEN MATAI►ACnJPoNG DRAWING TITLE FIG. 5.0 SAFETY HARBOR., FLORIDA 34695 PHONE (813) 726-1138 Dr SUCH MATERALS ARE PROWLED 70 THE RE�Oft ►OR SPECFIC PJNSES AND WST LIE DRAWING NUMBER IOPr CWMna AND 100-AMM OTHERS AD-TD-0031 43 �E bN°`',"�ADDENDUM Q�s � U \•tp pIM J ALT. OFFSET UNIT TIE -DOWN SPACING TABLES 6 ZONE II & III/EYP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE LIEN. WIND ZONE II WIND ZONE III FLOOR D� MN• OTY. EA. END OF EA SECTION ANCHOR ANGLE MIN. 0 WIN. OTY. EA. END OF EA. SECTIGN ANCHOR ANGLE MIN. 0 S ` 20'-0' N/A N/A N/A N/A 24'-0 2 42' 2 53' 254 2 45' 2 58' 26'-8' 2 48' 3 3-7° VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPAONG DOHEAD LOAD ANCHOR ANGLE SPACING DBL READ LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 4'-0' 40001 20'-30' 4'-0' 4DOO# 20-30' 25'-4' 12' 4'-0' 40DOI 20'-30' 4'-0' 4000# 20'-30' 26'-8' 12' 4'-0' 40001 20'-30' •4'-0' 4000f 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN. OTY. ANCHOR UK OTY. ANCHOR FLOOR WIDTH END OF Am EA. END OF ANGLE EA SECTION EA. YN. 0 EA. SECTION MIN. 0 20'-0' N/A N/A N/A N/A 2 60' 3 45' 2 1 66' 3 48' 3 1 41' 3 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' S-8' 40001 20'-30' 2'-8' 4DO0# 20'-30' 25-4' 12' 1 4'-p' 40001 25•-30' 3'-2' 40001 1.5=30' 26'-8' 12' 4'-0- 40DOI 25'-30' S-2' 4000# 25'-30' NOTES: ENGINEER �ffii1Sl2NNINI/N/A�� DAPIA APPROVAL 1. OFFSET SECTION MTN THE MARRIAGE LINE WALL EXTE1iM BEYOND THE ENDWALL OF �,�`��� C •Do�0��APPROVED BY THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE LINE IN ACCORDANCE ` ,O •Q'�'G� RFo F2- TMTH THE TABLES ABOVE THE soEWAu SIDE AND THE ADJACENT sECTION(S) ARE TO BE 71ED DOW IN ACCORDANCE TATH THE ALT. SPACING TABLES (AD-TD-0030). No. E 1=E% ^r ' 4 - INC, 2. SEE AD-7D-0001 FOR ADDITIONAL REOOBLEMENTS. 3. SE-TD-0033 FOR mauve PIER HOGHT REOU1RED cT v..•..L AILll SWCMM FOR THE LOADS TABULATED � C JACOBSEN HOMES THESE SPEGFHi1TION5 AND DRAMNf.S ��IK't npAIJ 1%%%I,,``�� Kt C.L.Y. DATE: 5-30-95 REV. lET1ER DRAMNG TITIi ALT. SPACING TABLES P.O. BOX 368 mafANAL, PROPIGETARY. AND CDIVWT4L MATERIALS OF JACOMNUFACTUtIHC BSi11 SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 WC. MO MATERALS ARE PROMO TO M R EMW FOR SPEOr t PJMO NO "I K PUT CWWT4t AM SEC CT FROM OHM DRAWNG NUMBER: AD- TD-0032 M \CAT\ON \S Na SEES i ADDENDUM \N\S �1p `ol �E.A�c� J ALTERNATE TIE —DOWN SYSTEM sloop TYP. CROSS SECTION(S) SHOWING TIEDOWNS MME M21 FIGURE 6.0 SEE FIGURE 3.1 FOR RECOMMENDED TIE -DOWN METHOD SEE NONE 5 FOR YAXW" 11DQR [TA B CH AD-ID-M Qp M APPLY TO NM STANDARD IALTI-Ml SiCUS OF THE UIBT -SEE NOTE 1. AD-TD-ML) TIP. BOOR SYSTW— ANCHOR ANOLE TIP. MOM MOLE FIGURE 6.1 SEE FIGURE 12 FOR RECOMMENDED TIE -DON MEXHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THER USING THIS TIE-DOTN 07IGURATIOH A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2)), AUGER ANCHOR THEN A DESIGN LOAD (TOLKM LOAD) RATING OF 4,000 PCURS AND AN ULTIMATE LOAD RATING OF 6,ODO POUNDS MUST BE USED. AN EQNRVI.AHT 0CHOR MEETDIG THE ABOVE SPECIFICATIONS WE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: 1. SEE AD-TD-OOD1 FOR ADDITIONAL REQUIREMENTS. 2. SEE OTHER DETAILS FOR BLODONG (PIER) QUANTITY AND OTHER REQUIREMENTS. 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE-DOYM SPACING TABLES (AD-TD-0020). 4. FOR FIGURE LI SEE NORMAL ME -DOWN SPACING TABLES (AD-TD-0010). (ALSO SEE AD-TD-0020 AND AD-m-0021) 5. ZONE 2/EXPOSURE 'C': 32' MAXIMUM HEIGHT ZONE 2/EXPOSURE 'D': 24' MAXIMUM HEIGHT ZONE 31EVOSURE 'C': 24' MAXIMUM HEIGHT ZONE 3/E*OSURE 'D': 28' MAXIMUM HEIGHT THE ALTERNATE TIE -DOWN METHODS SHOW ABOVE ARE ACCEPTABLE FOR USE N ALL WWD ZONES AND N BOTH EXPOSURE 'C' AND EXPOSURE 'D'. HOWEVER. BY INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TE-DOWNS. C. DOF No.9Fo �2 STA OE PROVED BY NIPINC5 :wisc:a v� wrns•�+ovTaW ANO ORA JACOBSEN HOMES rN°TICNr A��"NTTqk%,%`C.I..Y. °ATE` 5-30-95 `V'`�' THESE SPECn1CAT1pN5 WlN4i RE MO,NAL. PROPRIETARY. AND COPOUNILAL DRAWING TITLi YATENIALS OF JACOBSEN YANLFAC ratiG Mop SAFETY BOX LPL: SOOT MATERULS ARE P*OV ED TO THE FIG. 6.0 & 6.1 SAFETY HARBOR FLORIDAI 34695 . RECaPENT FOR PECSY PY61 35 APO KAT BE DRAWING NUMBER: PHONE (813) 726-1138 WEPT ca wn4L AID SEQta nldl ormm AO-TO-0033 45 ADDENDUM ALTERNATE TIE -DOWN SPACING TABLES ZONE lI&III/E.U.C&D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. W'ND ZONE II WAND ZONE III ANCHOR UK OTY. ANCHOR V S�rY` FLOOR W.N. OTY. EA END Of AN. EA. END OF ANGLE WIDTH EA SECTION YIN. B EA SECTION YIN. B 12'-0' 2 43' 2 13'-4" 2 50' 2 68' 68' �40 1 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE trAN MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD A4CIOR ANG,E SPACING HEAD LOAD ANCHOR ANGLE FLOOR SAVE WIDTH OVERHANG Low 12'-0' 6" 4'-0" 37501 20' 4'-0' 39001 22' 1 6" 1 5-4' 38501 25' 1 5'-4' 3960# 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WAND ZONE II WAND ZONE III FLOOR CITY. EA END OF ANCHOR ANfiF MIN. CITY. EA. ANCHOR ANGLE r WIDTH FA SECTION YIN. B EA SECTION YIN. B O� 12'-0' 2 64' 3 47' 12'-0" 3 37' 4 33' 13'-4- 3 42' 3 55' 13'-4'j:::::4= 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPSPACINGDELH - W ANCHOR ANG.E SPACING D LOAEL D ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG Low 12'-0" 6' 4'-0' 39501 25' 2'-8' 39300 20' 6" 1 4'-0" 39601 25' 1 2'-8' 4000# 30' IS-4' THIS ALTERNATE APPLICATION REQUIRES,,,,000 POUND ANCHORS ENO`11 Lt% PRqaL. O� �4��i' DAPIA APPROVAL NOTES, O 1. SEE AD-TD-000l FOR ADDITIONAL REWHREllENTS ���0?� GN No RFO ? APPROVED BY 2. SEE AO-7D-0036 FOR MAXWLIM PIER HEIGHTS REONRED FOR THE LOADS _ ENS 3703571 _ TABULATED ABOVE _ _ j" 5 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR.NIP INC, '' �+ 9 6 s�• 9 ' 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS W17H 95 1/2' :� Qom,•., //4VD1 N • r�� `: mao~`icraAwsweTTtwov� � BEAM SIDEWALL AND6' ►HA)ODUM SIDE • • �```��� II-BEAM�1111 EIGHTOF G (6I' OVERHANG MAX.UM 1Vt'sS/..1.... EACH SIDE: A NOTICE •TTT (A4vn -.• C.L.Y. DAlE 5-30-95 REV. LETTER JACOBSEN HOMES TNESE SP£�TH� AND IUW0 A OKn aaaNA. PROMUARt AND C0NrKiTM1 AYING TIT TABLES JACOBEN M NUFACTURING ALT. SPACING / i MATERIALS OF P.O. BOX 368 NG SUCH MATffdA S ARE PRONGED TO THE. O,%ppSAFETY HARBOR. FLORIDA 34695 KOPOT Fat IPECAC PtFtPOSHS NOWST K DRAWING NUMBER PHONE (813) 726-1138 PUT wNWR& NO SE00110 OrfUM AD—TD-0040 46 �000� Vkq ADDENDUM ALTERNATE TIE —DOWN SYSTEM TYPICAL CROSS SECTION SHOWING TIEDOWNS ANGLE ANGLE FIGURE 7.0 SEE FIGURE L3 FOR RECOMMENDED TIE-DDTN M=D IMPORTANT NOTICE: SEE NOTE 4 FOR MAXIMUM HEIGHT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS rILENI USING MS TIE-W" CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2), AUGER ANCHOR TIM A DESIGN WAD (TTORKING LADID) RATING OF 4,ODO POUNDS AND AN ULTDIATE LOAD RATING OF 6,000 POUNDS MUST BE USED. AN EQUIVE,AAT ANCHOR MEETING THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIKU OF THE STYLE CREST PRODUCTS ANMR NOTES: 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REIA)IRELIENTS. 3. FOR F1'G URE 7.0 SEE ALTERNATE IIE-DOWN SPACING TABLES (AD-TD-0035). 4. ZONE 2/EXPOSURE 'C': 38' MAXIMUM HIDGHT ZONE 2/EXPOSURE O': 28' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C% 28' MAXIMUM H0GHT ZONE 3/EXPOSURE 'D': 28' MAXIMUM HEIGHT 5. SEE AD-TD-OD35 FOR ADDITIONAL NOTES JACOBSEN HOMES „ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 THE ALTERNATE TIE-DONN METHODS SHIDVM ABOVE ARE ACCEPTABLE FOR USE IN ALL 1BND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE V, HOWEVER, BY INSTALLING THE FRAME TIE-DONN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLNC FRAME TIE-DONNS �O ►STEO�� i Q��,A •., F No. NO71CK" '11111111 jRtffi% ` THESE SPECRIICATLONS AND DRANIO ARE C.L.Y. ORIGINAL, PROPRETAIIY, AND CONITODRIAL DRAMWG TITLL. MATLAIALS OF.IACCIM MANLFACUM NG M MAIERWS ARE PROYM TO THE IECPtNT FCR SPECf1C RFPOYS ND M7S1 � DRAMWG NUMBER ,OPT CON WTVL AND SECRET n= OTMM APPROVED BY IN A' `5 INC Ft..-. .....:.;. m bg ca,.....,v. w wuntvcvs DATE 5-30-95 REV. LEM FIG. 7.0 A AD-TD-0041 47 ADDENDUM MISC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. SEE DETAIL 'B' SEE DETAIL DETAIL 'A' IUCKLE WITH 31501 Y MINIMUM (DESIGN LOAD) DETAIL 1 B' NOTES:. 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT AT BEAM -OTHER METHODS THAT ARE CERTIFIED TO MEET THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). L -BEAM LL DOWN TIGHT TO OUND ANCHOR INSTALL RADIUS CLIP (SEE AD-TD-0200) OR L R DEVICE TO CT STRAP AT ALL CORNERS. DETAIL 1C' THIS TYPE OF PROTECTION MAY BE USED FOR PRO`T;q,3pNiIAT LONGITUDINAL TIE CONNECTIONS ALSO. Q N0. o 910334 •• STATE OF.: IE D AND D OTHER' APPROVED EY lor 00 P 6:11' ON p itm.- fMM 10 AW S*Ul5UATURED M NOV 2 4 1998 LJONEI JACOBSEN HOMES NOTICE 1NESE SPEC6ICATIONs AND WAWNCS ARE aaCINAL, PROPR[TARY, AND CONF1 UMAL DRAWN BY: M.T. DAl 11-18-98 REV. LETTF DRAVANG TITLE: P.O. BOX 368 YATERALS OF JACOBSEN MANUFACTUPLNO MISC. TIE -DOWN B SAFETY HARBOR, 'FLORIDA 34695 REST FOR SPECFIC PURPOSES AND uml BE DRAWING NUMBER: PHONE (813) 726-1138 IVT COFMTK AND SECRET FROM OMS. AD-TD-0050 48 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR WIDTH WL CITY. Ek END OF A047R ANGLE UK OTY. Ell OF SECTION SEC MCHO ANGLE 11PLDH e EA. SECTION UK Ell 3 401 3 25 l�yo VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DRL ►E1J LO)a A4 t ME SPACING DBL KA DBLANCHOR ARE 30'-8' 6' 6'-9' 31501 41-46 5-5- 31501 44-49 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE u WIND ZONE III �i FLOOR A. GTE ANCHOR uuI CITY. ANO+E WIDTH Ell END OF EA. OF O EA SECTION ill. WI. B EA. SECTION SEC K YRL B 30'-8' 4 42 4 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE 0 WIND ZONE IQ FLOOR WIDTH EAVE OVERHANG SPAONG DBL W'AD LOAD AN0i0R ANtEf SPACING DBL HEAD LOAD ANCHOR ANGLE 30'-8' 6' 4'-6' 31501 46-50 4'-0' 3150E 49-52 VANDWNE III (110 MPH) 20 PSF ROOF 10 PSF D.L. y�� W. CALLS. G 4/4 - 14,01- 4, NOTES: 0. ... `Y�.'Q DAPu APPRovAL;..,MAR 0 C, Cy: •�GISTER� •�� I. SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS �� � • Q No. o ••. APPROVED BY 2. SEE AD-M-0071 FOR MAXIMUM PIER HEIGHTS REOUIRED FOR THE LOADS 910334 = •� TABULATED ABOVE oeo = -^� STATE OF' = INC. '.�i�'• D ;' rtOFNarrwrcMMraoNo�E I eoapm JACOBSEN HOMES Tww- sKancA='AND W,,,, m w Arrt1 BY: M.T. DATE 2_8-99 REV. LETTM P.O. BOX 368 ORCHAL. PROPRIETARY. AND MOSmiAL. DRAMANG TITLE: MATERIALS OF JACDBSEIM MWXACIUMINO NORM. SPACING TABLES \I SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 ING SUOM YATMALS ARE PROVWD 10 IF[ K MENT FOR SKCM PtRPOSES AM IAIST BE DRAMING NUMBER: IVI CORIDDMTUL AND SE00 MOM orem AO-TO-0070 �C° 49 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING 11E—DOWN SPACINGS •,• �.rw....ac rcn . lu_vry iwu r" PLrW_wru MILL YU( W-lu-mu Imu PER AD-TD-0010 UME MAX FIGURE 10.0 SEE FIGURE 20 FOR ALTERNATE IX -DOWN IO HOD TYPICAL CROSS SECTION SHOWING TIEDOWNS TYP• FLOCR SM10i7 7r• � / .—CHASSIS 3 SEE NOTE 5 FOR MAX31UM HMO N I1T.1n ANGLE ANCHOR ANGLE SET ANDN WA FIGURE 10.1 SEE FIGURE 50 FOR ALTERNATE =-DOTN METHOD WINNONE III (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES: tKN ER ' v �'�.� DAMA APPROVAL. 1. SEE AD-TD-0070 fOR SPACNG TABLES ��f',. G\ _; : No. APPROVED BY 2. SEE AD-70-0070 FOR OUANITY OF LONGITUUTAL TIE-00RN STRAPS MUM.910334 :_ awe ' * E 3. SEE OTHER DETAILS FOR BLOCKNG (PIER) QUANTITYS AND OTHER REWREMENTe 4. SEE FELL ADDENDUM FOR ADDITIONAL REOLIMOTS. �.-o =. STATE CF . lo4j: -N 5. ZONE 2 XPOSURE 'C'. MAXIMUM HEIGHT 56' y 9Q �'•. / C -,; ��• HD PA P C'• INC. ZONE 2% XPOsm V- 40' MAWLIM HEIGHT ZONE 3/DPOSIRE V: 56' MAMMUM HEIGHT • 1 .• ' '4� •' � MOW �wwr�rr oos�n ZONE 3/E)POSIRE V.- 40' MAMMUM HEIGHT s �/►�� HOMES NOTICE' TFESE SPECFlCATIOIIS AND DRA Ma ARE DRA M.T. DAIS 3-1-99 REV. LETTER: LICACI P.O. BOX 368 MMKIL PRWK7ARY• AND co►, MTK MATMALS OF MCOBSEN MAMIFACTURNC DRAWING TITLE: FIGURES 10.0 AND 10.1 „ SAFETY HARBOR. FLORIDA NG WM MATERINS ARE PROVM TO M DRAWING Ml11BER: 7-1 8 KEPT eft NO �r FROM MM4695 AD—TD-0071 50 ADDENDUM. NORMAL TIE-DOW N SPACING TABLES ZONE II & III/EXP. C & D i LONGITUDINAL TIE -DOWN SPACING TABLE (1� MIN. WIND ZONE d WIND ZONE UI FLOOR WIDTH UK OTY. EA DID OF EA. SECTION ANCHOR ANGLE UK 0 uDL CITY. EA. DO OF EA. SECTION ANCHOR ANGLE UK 6 O� 154 3 45 3 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DBL WA LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE 154 6' EACH SIDE 6'-10' 3ml 40-46 5,-6' 3150/ 42-47 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE Il WIND ZONE III FLOOR Ua• OTT. ANCHOR HUL CITY. ANCHOR \ WIDTH Ell END OF ANGLE EA, DO OF ANGLE ^ O v �\ EA SECTION MIN. 9 EA SECTION WL 9 15'-4' 3 30 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND Z(X4E 0 WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DLOHEAD ANCHOR Mai SPACING D HE ANCHOR ANGLE 15-4' 6' EACH SIDE 4'-6' 3150f 42-50 4'-0- 31501 44-50 VANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALCS. c, w —%2. OI — -72 , 1`/j . ,,,IrITnN NOTES: ONGIIgR 0V r, DAM APPROVAL:MM 6 1. SEE FULL ADDENDUM FOR ADDITIONAL REOUIREUENTS. � \STER F�! �,, `�`� �Q N'- ro '•. APPROVED BY No. 2. SEE AD-1D-0073 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LORDS TABULATED �_ 910334 ABOVE 3.. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. •. Ce 4. ABOVE TABLES APPLY TO 184' FLOOR WIDTHS WITH 95 1/2' I -BEAM SPACING, 96' MAMMUM S47EWALL HEIGHT AND 6' MA)OMUM SIDE -o . STATE cc, 444 ; . P; ''��•• 0 NN.`�` ��'• INC. _ I v oa pypLufffg x*m OVERHANG (6' OVERHANG MAX EACH SIDE OF UNIT). ' is rb JACOBSEN HOMES NOTI NIr THESE SPEQnCATIONS AND MATMCS ARE It BY: DATE. REV. LETTER: M.T. 2-8-99 ® P.O. Box 36a CRONAL PROPRIETARY, AND C@f10ENnAL MATERIALS OF 1ACOBSEN MANUFACTURING DRAWING TITLE: . NORM. SPACING TABLES „ SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 B+C Sllol uAtpIIAtS ARE PROMOED TO TIE RCME NT FCR !P[ rIC PUIPMS AD WAY BE ►APT mnDENTUL AND SECRET rROU Orro DRAWWC NUMBER- AD-TO-0072 �n 51 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS MAX PER AD-TD-0012 TABLE PER All-TD-0012 TABLE PER AD-TD-0012 TABLE PER AD-W-MZ TABLE PEx AD-10-MZ IIAEU MAL TYPICAL CROSS SECTION SHOWING -TIEDOWNS FIGURE 10, 2 SEE FIGURE ZO FOR ALTERNATE TEE-DOIN UMD s SEE NOTE 5 FOR MA N HEIGHT N ARM OF HOME (TIP.) FIGURE 10.3 SEE FIGURE 7.0 FOR ALTERNATE I E-DOWN WWD NOTES: 1. SEE AD-M-0072 FOR SPACING TABLES AND NOTES. Z SEE AD-M-0072 FOR IUAHRTY OF LONGTUDIAL ' E-DOWN STRAPS NEOURED. 3. SEE OTHER DETAILS FOR BLOCKING (PER) OUANTITY AND OTHER REOLI MENTS. 4. SEE FULL ADDEIDLN FOR ADDITIONAL REQUIREMENTS. 5. ZONE 2/E1POSLIfE 'C': 56' MAXIMUM HEIGHT ZONE 2/D(POSLRE V: 56' MAXIMUM HEIGHT ZONE 3/01POSIIRE 'C: 56' MAXIMUM HEIGHT ZONE 3/EXa'OSLIRE V.- 56' MAXIMUM HEIGHT JACOBSEN HOMES El „ P.O. BOX 360 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 CALCS ..�„IN,IIRIIL.. i .6%STER le - 910334 -� STATE CF NOTICE:- THESE SPEanCATIONS AND uu ARE ORIMIAI. PROPRIETARY. AND CCNFIDENTIAL MATERIALS OF JACOBSEN MANUFACRA4INO W_ 9" MATERALS ARE PROW= TO THE RE(aMT FOR SPECIM RtT 1M AND M= BE MR OONiIEUM I AND SEOREI FROM OTNM DAPIA WINDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L APPROVED BY 0 oor IN 14 NC. REM VA.IRICNMI®IIDIE �AIpOUIYTNIi7FtaOMN� loo= V4 DAIS: M.T. 3-1-99 FIGURES 10.2 AND .10.3 L. AD-TD-0073 ADDENDUMVCJ AR�s 0 OFFSET UNIT TIE DOWN SPACING TABLES. 1 11� ZONE II & III/EXP. C & D 11 �, LONGITUDINAL TIE —DOWN SPACING TABLE MIN, WIND ZONE I WIND ZONE M V FLOOR MIL QTY. ANCHOR WIL QTY. ANOW �G MOM FA END OF ANGLE EA.END OF ANGLE FASEC1IOt1 LPL a sw EA. swim Iwe 4T 3 61' 13'-4' 2 54' 3 41' 15-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE W SPAfIIG HOD ANC110ft ANGLE SPACING �LOAD� ANOiOtt ANGLE WIDTH OVERHANG EAVE 12'-0' '12' T-0' 31501 4T 4'-0• 31501 39' IS-4' 12' 5-0' 3150# 41' 4'4' 3000# 40' 15-4' 12' 5-0' 31501 43' 4'4 300011 4T LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE NI FLOOR NIL OTT. ANCHOR MIK OTT. Rm"CmH A OF EOF ANGU O EA SECnN uIL e U SEn MIN.s 12'-0' 4 45' 4 60' 13'-4' 1 3 45' 3 60' 3 45' 3- 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE . MIN. MAX. WID ZONE I WND ZONE II Spas ML HEAD LOAD ANCHOR AM SPACING oBIL HEAD LOAD ANQRiIt ANGLE FLOOR WIDTH EAVE OVERHANG 12'—V 12' 4'-0' 31501 40' S-0' 30001 3r 13'-4' 12' 4'-0' 30651 41' S-0' 3000# 3T 15-4' 12' 4'-0' 3001 43' 3'-0' 3000# 41' NOTES: C*tZ5. C- SL - 16 �Of— �6 ,12, ENGINEER A,L__9068141rp , Nff. CALCS.(C- Cl- 17"G - v• DO4C,•�a► / 7� O$ 1. OFFSET SECTION WIN THE MARRIAGE LINE WALL EXTENDING BEYOND TIE ENDWALL OF THE ADJACENT SECTION MUST BE TIED DOM AT THE MANAGE LYRE IN ACCORDANCE .�`���`� �..'`��-r1F1�gT �'�D :�y�, G BY WITH THE TABLES AB01E. TIE SIDEWALL SIDE AND TIE ADJACENT SEC110N(S) ARE TO ; BE TIED DOWN N ACCORDANCE N IH THE NORMAL SPAONG TABLES (SEE AD-71)-0010 • JUN FOR 12'-V ! 13'-4' WIDE$ AND AD-1D-0070 FOR t5-4' HIDES} 2 SEE AD-1D-0001 FOR ADDITIONAL REW EMENTS. J. SEE AD-TD-0081 MU11 FOR MA10PER HEIGHT REQUIRED FOR THE LOADS TABU . C� •. Q • ••: SORIUP:•• INC. 1 vLATLD ABOyE ��4'.•�1 EEIMLIVIANUFAIMIRED HOME JACOBSEN HOMES rem SECrlcNTM &WW w '�' + : _ os`' •T• ` DA>E: 6-8-04 im m"' ` P.O. sox ass� ,. . emu• MWIMMY A"M MA Tfi M OF dR MI MMUF K NI,� „HE m DBAWNG TIRE - OFFSET SPACING TABLES DFIANNG NLlYBIA AD—�—D080 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 ffam FOR 9 M PIAr06£S WT CMEOMM No SUM 53 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ WSET SECTION) SHOWWNG TIE -DOWN SPACINGS FIGURE 11.0 SPOT F1lxlRiN 4.0 Nit aLi US 711-WO 1D;1'BOD TYP. CROSS SECTIONS) SHOWING TOOWNS SE NDIE 5 FOR 000 0 I60R [TAB Of AD-m-ONO mm APPLY 10 Im SRAIOARD mml1 _ 0E SEEw OF INE WT -SEE NOW % AD-ID-OOSD.] M FLOOR SYS0-7 r F—kwu A A� 1 R 1 F-- ANm ma �6�. Syr-�-4�G• FIGURE 11.1 sic RM 6.1 MR AMM M-DO11N So NOTES: I. SEE 0-M-0080 FOR SPMW TAKES (OFFSET SECMiN ONLY 2. SEE AD-W-OOSO FOR OLI MTY OF LOWWOUL TE-DOMM STRAPS REMO. (OFFSET SECTION ONLY) l SEE OTHER DEFALS FOR OLW N1G (PER) OIlANI Y MID OTHER REOIAREMfTITS, 4. SEE AD-TD-0001 FOR ADMIONAL REOINREMFNTS. 5 ZONE- 2/01PORK 'C: 48- WMA IEFCHT ZONE 2AVOSIIRE V: 40' MAMM NEIONT-36- FOR 12'-O' WIDE UMTS ZONE 3/E7�OSlLtE V- 41r MAMLIM HEIGHT ZONE 3/ExPo6l1RE V: 40' MAXIMUM HENGIIT TIP. ANm mu-4 R �fF. c4<<• FIGURE 11.2-g° �,'9;08� jj M ALMi1ts =-WIN IMWD [ `� 4 DAPIA APPROVAL• Ise �~ '•.t , atFi�'•�'do PPROVED BY •G 0.004548 JUN 11 20 INC. i p� • P .�� a1 ERAL NUFACTURED HDb1E e•�'••' {i1�•. `1 RUCTIONAND PFMSTANDARDS JACOBSEN HOMES P.O. eox 3sa NOTICIk 't' ;R � SPEECFMTM AM ORAYM AM awahx, PROPRETARN, Arco CORF MIM MAM&S OF JACOM WlAFACRAUNG : ARA"w. M.T. DATE 6--8-04 REV. lEffER DRAWWG TIM FIG. 11.0, 11.1 & 11.2 MAWNS ARE W_ stray alOMD ID J-� SAFETY HARBOR, FLOMDA 34695 IT3>PEIIT FIN Sa'EliIB MOSM NO W 6E DAYN NLNM: PHONE (727) 726-1138 wr mfEwx AID SECAFT FROM Olm AD—TD-0081 F;d ADDENDUM ALTERNATE 'OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OfFSET SECTION) SHOWING TIE —DOWN SPACINGS FIGURE 12.0 SEE FIGURES 11.1 AND 11..2 FOR NOTES: 1. SEE AD-TD-DOBO FOR SPACING TABLES (OFFSET SECTION ONLY 2. SEE AD-TD-DOOD FOR OUANITY OF LONGITUDIAL TIE-DOBN STRAPS REQUIRED. (OFFSET SECTION ONLY) 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REQUIREMENTS. 4. SEE AD-TO-ODOT FOR ADDITIONAL REOUIRENEN75. 910334 -0 . STATE Of SEE C�ICGS, �G, �- s�- I6 •oi - 16: ��- -SECTION :P.f.F.i NJUFN T IAM, H•OM.: JACOBSEN HOMES THESE SPEOT1CAn0ONSEAO DRAMNCS ARE DRAWN BY: R R DATE: 5-9-01 REv. LETTER: ORMAL PMXTARY. AM ODIi1o01RAL DRAWING TITLE: P.O. BOX 368 MAXIMS OF JACOB5ET1 MANIICAC1U M FIG. 12.0 SAFETY HARBOR, FLORIDA 34695 n Nt NAsKax10W ARE PsEs AmDEV To 1H[ PHONE (727) 726-1138 PUT COW VAA�o�SEaRET FROM OTHM �A WNG � AD—TD-0082 ADDENDUM GVRts 108" HIGH SIDEWALL TIE -DOWN SPA IUG TABLES stt 0 101 1 ZONE II & III/EXP. C & LONGIT INAL TIE -DOWN SPACING TABLE WW ZONE I WIND ZONE N FLOOR MK Of. AFFm A OTC mom t V01H . END OF MU EL OF mai SET:T101 IeL 0 EA SECDON MK 0 26'-8' 3 42' 3 53' 52' 4 45' VERTICAL TIE -DOWN / FRAME TIE -DOWN i SPACING TABLE WN. MAX. WIND ZONE I WM ZONE N YWDTTHH EAIVE OVERHANG SPAW DEL D LOA A14M AWU SPOC °�� ANOIGR ME 26'-8' 6' W-8' 31501 40'--50' 64 3150f 4(r 50' 30'-8' 6' 6'-8' 31501 40'-50' 5-4- 3154 40'-50' LONGITUbINAL TIE -DOWN SPACING TABLE MIN.. WIt4p ZONE I WAND ZONE N FLOOR cTY Do, OF rs%Ecm AWN AFIRE WL OTC EA00 ff AFFDHOIT AM WIDTH WL 0 EA SEMN Ill 0 26'-Ir 4 41' 4 57 W-8' 4 51' 1 4 70' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE N FLOOR YADTH OVERHANG SPAIM Lm MI01011 NHiE SPAONG � ANIXR MQr 26'-8' 6' 5-4' 31501 40'-50' 4'-0' 31501 40'-45' 30'-8' 6' 54 31501 40'-50' 4'-0' 31501 40 -45' VWNDZONE RI (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALM NOTES: a • Il:.. ..•.: ;_ •�`j�F'� . DAPIA APPROVAL: 1. SEE RAL ADOOIIIII FOR ADDIROTIAL REOWRELENM �. �� G� 4p.. .,3 APPROVED BY ` 1 N0. 0045484 2 SEE AD-TD-M FOR MAYMN M HOOHTS WMI ED FOR TIE LOADS TADll O ABOVE --rNTO �, • sf INIC. �r��'��+ ••....••• ���' FEDERAL MANUFACTUREDH�OME RFu �jG Ef i CONSTRUCTION AND SAFSTD NDARU5 j�. i ."t``• t JUL 2 7 ?W4 JACOBSEN HOMES NOTICE: DRAIN ME C►TIM AM WA>MM AK BTF M.T. DATE: 07-20-04 REV. LETTETT: TITLE: 108' HIM SIDEWAIL SPAaNG TABLES P.O. BOX 368 01MIK• MWFKTMX AM aoWRmrl& DRANK YA1 US W ACWS " UWAC IMM WC SM WWAN1 NE FWW= A TIE SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 FIEWW Fat VIXIC FEW O93 NO ON E DRANK WT car MR& NO MU FFM DIM .40 N l� AD—TD—OW3 56 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS TYPICAL CROSS SECTION I I SHOWING iIEDOWNS aooR MON mu SET MON WA FIGURE 10.0 FIGURE 10.1 TIP. G11115-1El� _cwm Ili SEE NOW S FIX ,r HAWN HIIOff MQU MGLE--J WWZONE M (110 MPH) 20 PSF ROOF 10 PSF D.L. NOTES: v__ —no — 1. SEE A1I-11ID-W FM SPAM TAM� �. G��'►Y�F • • APPROVED BY 2. SEE Ao-lo-6oa3 FM OUANITY OF Ldi4MM X-OOHMH STRAPS MOM � •' 3. SEE OTHER DETAILS FOR LLOWQ (pa) oumnTr AND om REwi aE m 4. SEE RILL AODIMN FOR ADDITIONAL REOLIFEW34M QQ S. ZGHE 2/bPORK V: 36' MAMMUM HEIGHT Rf ~ INC. �. ZONE 2 V: 2T MAXHAAI HEIGHT " ' , Q' 1 ZONE a/b V- 3a' MAXIMI HEIGHT '�OAS►• ���� FEDERAL MANUFACTURED HOME ZONE 3/E�OSlHRE V- 32' MAXIM! HEIGHT C •••'••.•••:•• CONSTRLICTIONAND SAFEHYSTANDARUS E ALL SPECFD IONS ARE BASED ON 2O• ROOF ANGLE MAIL t ` JACOBSEN HOMES > mm me , M.T. 0A1E 07-20-04 HaE,► ` GMAL PROPM IY, NO OMMMIL MAWS 7IW-,i P.O. Box 3se ' AMMS W PAN= MWACRIM FIGURES 10.0 AND 10.1 W. go MI111 M NEH: MOM 10 m SAFETY HARBOR. FLORDA 34695 I nni FIR 9EM 1OF= NO EM K DRAWING N AI PHONE (72� 726-1138 ITT oo�mnK No �ac1 FROM o1�e1�s AD—TD-0084 w ADDENDUM 108" HIGH SIDEWALL TIE -DOWN SPACING TABLES ZONE II & III/EXP.. C & D �0 0 LONGITUDINAL TIE -DOWN SPACING TABLE t (�� MN. WIND ZONE 1 IND ZONE 19 V FLOOR WL OTY. Ate m yx am lY ca WIDTH EX END OF .. AM U N OF MOLE O EA SLtT1011 MR 0 U $ 001 VK B 13'-4' 2 24'-0' :. VERTICAL TIE -DOWN FRAME TIE -DOWN SPACING TABLE - RN. MAX WIND ZONE I WIND ZONE 11 1T A10NOVINUG EAVE SPAM MIL LOAD moo ME SPAM Deice AMU= ANOE 49' S'-4' 3150 45' 24'-0' 6' 6'-8' . 3150 49' S'=4' 3150 45' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE III FLOOR YOL OTT. AHOY WL 4TL moo WIDTH E END or ANfiE EA. DO OF EA SEC°01 MIL' Q EA 5ECD01 VOLv Yl 1 2S-4' 3 48' 4 43' 24'-O' 3 V 4 -45' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE WIL MAX WIND ZON% 1 w ZONE II VAOTTHH OVEiIIiANG SPAM LIN ANm AHOE SPADN6 LOAD AMIXII Mu 31501. 47* 4'-0' 31 43' 24'-0' 6' 5-4' 31501 47' 4'-0' 3150 43' 108' MAX SIDEWALL HEIGHT M1NE)ZONE R/lR (110 MPH) 20 PSF ROOF IO PSF O.L. RFF. CALCi ,`i�ia�rrsrrSlo" NOTES, "`=0 �� O ....... F. '�•4 DAPIA APPROVAL: APPROVED BY 1. SEEM ADMIGUY FOR ADDIAOHAL REOIXUAIDIM G�'`; ^`,,✓ +, ON 2 SEE AD FOR YAIG1AI11 PIER HENi{i5 REQUIRED FOR THE LO .'� TABULATED ABOVE H=. '1�t ' Dea 13,2006 . b INC: FEMM � JACOBSEN HOMES iIESYbPEORCANXIGAMM400AM' elfR.R. °A 11-28-06 REV. LEnK- P.O. Box Sea 1XIMIAL MOTH L AID OQs10EMM ►ummt w p4mm MAMWXRWK IC slot YAMILS Nt H040 TO TKL DuwxG lltLl 108' HIGH SIDEWALL SPAaNG TABLES SAFELY BOR, FLORIDA 34695 vc HAR(%.) 7zs-naa WPM I R Jmu PUwV0.5Es quo Mar K NVT oar AM SOO ma VKK DRAW4 MJMBER: A0-TO-0085 58 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION . SHOWING BE -DOWN SPACINGS. FIGURE 10.0' - TYPICAL CROSS SECTION I I II .. SHOVIING IIEDWIS TV. It= SWEII-7 I 11P. QOSS-1Q� SET MOO a iiIIIIIIIIII®m s STF Tat[ 3 FM L KmW HEIHT ANDICR ANGLE of AFFROG SIABUIER i HSDLLM MIN ANORd1 rN1 mmm INHDM N.M. FIGURE 10.1 �20 ROOF 10 PSF D.L �s.-- - 'S h. NOTES: �►' . t1 rdi� �+� APPROVAL: 1. SEE AD-TO-M tort SPAM TAMES �•(:'T._ %r ..*� APPROVED BY i SEE AD-?D-M FOR OUNI IT Of LUHOTLOAL IE-DDMN STRAPS REOUIED. 3. SEE OTHER DETAILS FOR OLD= (PEA) QUANTITY AND OTHER REOUfAEYEHTi . FJJ. L+� ` ON4. SEE FU.L ADDEIM FOR ADDITIONAL REOlAHEYOITS ; • : P11N eC23,2006 ZONE :/DPSK V.:r YAmN mwa : 1 a C C. ZONEJ/E>v'OSUR T: 44"-MAIOLIAI NOWT - : •nl - FeWOU ■YIrIFAC1U11EOHOME 2011E J/WOSiJRE V. 3r MAIIMUp HEIGHT {�P '1(` ,� Tan onos+wMSTumAaos 6. ALL S9EcncAras ARE BASER ON 20' ROOF AHQE MAIL AHD W YAl • D,�. •' `y SIDEWALL HEIDIIL +�iC�i• �``� Roll t"ItUt DATE Rr% DI im JACOBSEN HOMES 1� OUNMAK R.R. 11-28-06 O WA. PRW"UA EL ACID DPAtEI1 - DRAWIC IIU' \% P.O. eox 36e MAlO1WS OF "c°`g'1 """'FA"1""` FIGURES 100 AND 10.1 NC 41Or HAMW ARE M ON= TO 1K SAFETY HARBOR, FLORIDA 34693 Kmmr Im v me r AmM AM =9 K DIAIM MAasER: n PHONE (727) 726-1135 our OWMIAL .o =amim obm AD —gyp— 0086 59 ADDENDUM (108 �IDE1kALLP) �q NORMAL TIO—DOWN SPAC�INC TABLES �.`�. 'N-0°131 ZONE it & III/EXP. C & D l O�V �l LONGITUDINAL TIE —DOWN SPACING TABLE Vi FLOOR TH 04*0 zONE a 00 ZONE m wt ii EIp a sEM* AIpE• 11i1 a EA S CF 1A SECIta ' kk 6 12`-0` 2 53' 3 40' 13 -4` 1 3 37' 3 46" 3 45' 4 49 VERTICAL TIE —DOWN / FRAME TIE —DOWN PPAC1N0 TABLE VN FLOOR ODTH VAX. EAVE OVMA4G VJD ZONE n #p ZONE Ili SPA* VAX w AIp10k MOE• SPA* VAX m AhOW Alp O 12'-0' Ir EACH SIDE 5'-4' 72` 3Y TO 41Y 3$' 45' 13'-4' j V EACH SIDE I 5-4' 80` 35' TO 40' 5-4` 42' 45 154 1 a EACH SIDE 5'-4' 80` 40' 54 46' 45' LONdPPUDINAL TIE-- DOWN SPACING TABLE ok FLOOR 9i10TH ZONE II ft ZONE In VkoTT.W, FA SEftor ilil e DTY u OF ixCT1* kw e 3 44' 4 40' 13'-4% 3 52' 4 45' 4 44' 4 56' VORTICAL TIE —DOWN / FRAME TIE— DOWN ¢PACINU TABLE FLOOR OOTH VAX EAVE OVERHANG 00 ZONE 1 ZONE III SPA* VAX P8 AhM AhM* VA* CAPER AIjOo Ate' 12.-0r 13'-4' 6 EACH SIDE 6 EACH SIDE 4'-0' 4'-O' 72` 72` 37' 40' 4'-O' 4'-0' 34' 38, 40' TO 45' 40' TO 45' 15-4' I V EACH SIDE 4'-0' 80 40' 4'-0' 42' 40' 10 45' • NOTE: 1hHEN ANCHOR ANGLE FROM VERTICAL CANNOT BED ACHIEVED. ADD APPROVED STABILIZER PLATE. (SEE NOTE y5 FOR HOMES SET IN FLORIDA) NO W 1, SEE Flu ADDEfy W FOR ADDITIONAL REWKYEWS 2 TARE BASSO DN ANOM *0W)(G LOAD a.11501 Alp DW;OW TIE TO oPPOgTE eeA11 a VAX EAVE OWMANG REFERS TO OVERHANG AT SDE*ALL NOT FRONT OR REAR. AI1BB0Oyy�� 1A81E5 APPLY TO 1N`�1�160. AND 184' FLDOR *el,m•s� �TH 99 l/2 4. I-eEAI� SPA': IOB U'AWUW SOEWALL HDG HT AND 6' iAAX�UI� OVERHANG (6' 0► *G W EACH. 9DE OF Ti KA WE S STA%gER PLATES ARE REWIPED ON S+DE*ALL ANOM AND LoWTuDNk ANCHORS SET N FLO WA, SEE DWY RHIE 15c, EFFECTIVE VA" 2% 1999 EN AL• ` ^ rr DANA APPROVAL; �w°� (� `;��` .��;:/ APPROVED BY ii.. `� _.� rtar 25,2008 �� N PINc. ." FEOEwu. YANUFACIx11ED MOMS ' coxsnwcnoxnnosnFErvsT�xonaos • „ : �iC �'•:; i C.a I o' • cif fiRED E�= ..,� JAGOB,�EN HOhtEO ® P•O. BOx 356 SAFEPHONE(72>7 T16 ARBOR D I38 95� THI�rAAI0�I► ANAL, PR�I1[[AR14 AlA rk AEI T�AI$.HF Yore IIICG 9101 1fA1ENk5 4i P1 A1pD 7I1 >HF r`c01lHpE1l dlp Y nql D.I.T. DATE: 12-11-01 REV. LETRR DRA SIG T1TLE: 4()R�I. SPACING TABLES DR G AO—TO-0087 OV 0 ADDENDUM SHEARWALL TIE-DOWN/PIER REQUIREMENTS EA . SA LENCM - . . I". *V LFTx.'IU Too PFJt SHEARWALLS (AIL STiuNl ) E(T. Ulf teal ti% 3/9 LINGI cum "IK PA a( talc 7v fol srEI WA(LS (ILL ilydAWQ W-cows RikiJ m Quo da IR Mr O{ moO `41M NOTE I ut NOTE 1 ME mm T sm NOTE iv %a pOTES 2 AND 3. � SM KM 2 AND I A A ra REAb Mot REdD m " m Rmb THS LOCA71W INS WATTDN IHS L%At" TTaS 1DCw11trH FIGURE 8, 0 FIGURE 8.1 THE DETAIL ABOVE IS SHOWN WITH A TWO PIER SHEARWALL CONFIGURATION, HOWEVER, THIS DETAIL APPLIES TO All SHEARWALL CONFlGURATIONS, ALL ZONES. -AND ALL AF VALUES. �APIA N YM N r.OlrE-oQ 1s a T+tY ARiA>; Ti-W�f s1Tiw 1(Ai a LOCITm 1N �` PPROVED BY ow Or PC W." Dim Af3b1fE om ROYm AT IDTNl , , 094W A90W TD DE MTED rOlt AN MUM U Lf �i2S/ (11]o MS CN LOAD (NA AO-0-W tlD�'lXRAL NOTES] FW NM Of WM AMa70t ma"mK) � .; •"r•� .� �� �(G�� � �' F ••:� '- e� t EB 10 LUDO L NN" A M AT CAOf DO Cr M SfAi"I Man (rot T1Q A1101t uT � [mot Moo Al E&CH Do W "Sr3 RU M1[E=S cr �E-oq�e� sUuw ktaA17�a1rTsJ � e' �0• a 910934 � � INC, A, * 01 "MiNLL TS L=IW A KK A 501 KAM M KWT 0015,-tl1f3 M No � * ��� t ERAL MANUFACTURED HOME 1aW AQi RcaxtEO CALL 91W(A1Li m�rsunorcz ALL ores :c $TATF QF ; '4�i 2 NSTRUCTIONAND SAFETYSTANDAROS Akio >pa saj JACOBSEN HOMES K°TLca� ��:"`��R.R. �"'�oi-o1-oo R�sC 7'EfXIG�1VO PCa�aox.L. Pfa�'R6wY, Aw •. wm- P.O. Box 394 rAMMAS ar 4k== y a� S/W TW/PIER REO. 1iiC !rlGl " ms ARE I'k WETYNARGMFLom0A.1ae5 tm�orikt=rwomodwa.c DRAMo+G�+�etx:, PHONE (W) 7Ta-1138 1�r oo:rpGct4 •+o ofrxcl fitdf ceanc AD-TO-100 61 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE -SECTION TIE -DOWNS / CEIU40 WAY BE FIAT OR SLOPED SIDE VIEW 1 1/4' X .035' 71E-DOWN STRAP C0RNUOUS AROUPID JOISTS. END VIEW 350 PLF WAXNUW SFEARWALL DEMN VALUE (PER WALL) 1 1/4' X .035' TIC DCYM STRAP C0NTINUCJS ARCJ\D JOISTS. NOTES: z .,(o E iji �W�YiOvAL • ,� �/y •� DAPIA APPROVAL: 1. Gwm ANCKM TO BE RATED FOR AR ULTIMATE LOAD OF 47151 [3150 DE9011 LOAD] (SEE (SEE AD -ID -*:DI 17D-fFNi�AL ROTES] F011 NmZ ON E>Louw ANOIoa R:StAliJlnai) ::"? 1 'r APPROVED BY L INSTALL A PER AT EACH END OF TIE SNEARIWAIL JOISTS (PER lK AWVE DETAILS). ON 3. WWLW S1•EARwAU. IS LOCATED ABOVE A SOJD IEADER (RAL I-RNT CROSS-UDMp..) NO TE-M" STRAPS. OR PIERS ARE REOU M (ALL SWMWALL C0NFICLRATIOIIS, ALL ZONES • ; AND ALL EXPOSM). 4. TIE -DOWN S1RJ1P i �' • 4��++ •. •: :� : , i REQUIRED AT EACH END OF JOISTS, ALL D8= rvW CONFLOJRATIONS. �� . ' • • .. �.'. ,. N l• mi 1 V V. 5. CEILNC S`fOWN FLAT -OPT CATHEDRAL OR SLOPED CELINC LIAY BE USED.tiL�``�� 6. ! ! ' C•`� ROERAiwwLsµ s_; w .� C�GTA:TA�ArC SA'P•: FULL W1D1H SHEARWAt l5 11RE SH0W11 IN 11E DETAL ABOVF NOWE, ANY LENGTH , VEA �� 1 •� !!� l�JrIIIII111LTTA�t OR C0HFTLXIRAT04 SIEARWALL WAY BE USED. NOTICE DRA`AN BY: DALE REV. LETTER: JACOBSEN HOMES � S-ECIITCATIM AVD DRAwNGS ARE R.R 2-6-96 ORC. uL PROPRUARY. RA) CQMMAL DRAVANC TITLE: 5plqrF P.O. BOX 368 WAIERAS CF JACOGS�04 WANUFACTURICpgL. S W CONFIG. T1E—DOWN SAFETY HARBOR, FLORIDA 34695 p apoll roq � K ARE a g we vat TO r PHONE (813) 726-1138 IVI CD*v..Nna AND w-aET ntm onus. DRAW\, NuuFER: AD—TO-0110 62 DOUBLE SHEARWALL .CONFIGURATION TRIPLE & MULTI SECTIONS CERJNG MAY BE FLAT OR ) SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) �( (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) \- 1 1/4' X .035' TIE -DOWN STRAP MIN. CONTINUOUS AROUND JOISTS. TO 35, 1. CROU1D ANOiORS To BE RATED FOR AN IATWATE LOAD OF 47251 (3150 DESIGN LOAD) (SEE AD-ID-0001 (1D-GENERAL NOTES) FOR NOTES ON GROUND M04OL INSTALLATION.) 2. INSTALL A PER AT EACH ETD OF THE SHEARWALL JOISTS (PER THE ABOVE DEIALS). 3. NO SFEARWALL IS LOCATED ABOVE A SOUR HEADER (FULL HEIGHT CROSS-MEwn) NO C TIE-DOMN STRAPS OR PIERS ARE REQUIRED (ALL SHEARWALL CONFIGURATIONS, ALL ZONES AND ALL DPOAIRESJ 4. TIE-DOWNN STRAP REWIRED AT EACH END OF JOISTS. ALL DBL S/W CONFIGURATIONS 5. CEILING SHO'AN CATHEORAL OR SLOPED, FLAT CEILING MAY BE USED. 6. FULL WIDTH SHEARWALLS ARE SHOWN IN THE DETAIL ABOVE. HOWEVER. ANY LENGTH OR CONFIM.AT1ON SHEARWALL MAY BE USED. 7. THIS DETAIL UAY APPLY TO TRPLE AND/OR DOUBLE WIDE SECTIONS. 350 PLF MA)OOJUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. John G. Doeden, P.E. 15133 C. R. 22 Goshen,IN 46526 N IS A TRIPLE WIDE RAFTER, APPLICABLE TO STANDARD ILE WIDE TRUSSES. 4D VIEW X .OW TIE -DOWN STRAP UOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SUP SIDE' MARRIAGE WADS MHEN AT LEAST 2 STANDARD VERTICAL 71ES ARE INSTALLED. (1 EACH SIDE ADJACENT TO SHEARWALL LOCAMON) APPROVED BY 5 I 0 0** ;0$ 1 N . rrl I N \..�. ��in�11�a4Aw wm�iwr..rx JACOBSEN HOMES NOTICE THESE sPE4anaTIDNs AND DNGN4FNs AMR.R. ONGINAL. PROPRIETARY. AND COFOiDMpA MATERIALS OF JACOBSEN MANUFACV"G DRAWN BY: DALE 4-09-96 REV. LETTER: A DRAWING TIE P.O. BOX 368 ITG SIKH YAITRMLS ARE PROmco S/W CONFIG. -DOWN HARBOR. SAFEPHO TO THE WT OIT WSJ no DRAWING NUMBER: ETY (513)F726ID11384695 car SEagS� AD-TD-0111 63 PORCH ANCHORING DOUBLE HEADED 3,t NOTES: L SEE SET-UP MANUAL AND ADDENDUM FOR APPUCABLE BLOCVJNG X .035" TIE -DOWN STRAP JOUS AROUND STRAP BLOCKS. MNDZONE ID EXPOSLRE 1C (1140 hiPH) 20 PSF ROOF 10 PSF D.L REF.,CALCS." og,4 7 1 :0ADAPIA APPROVAL: _JAI PPROVEDBY' 1 4 19INC. PEDESA MANUFACTURED HOME L N NST STRUIVION AND SAFETY STANDARDS MC Ili t w NOCF. - : JACOBSEN HOMES 7KSE SPECMAVMTIAM DRANWDRAWIN BY. 5 AK M. TDATE . 12-13-03 REV. LETTR MONA4 PROPNnNY. AND CD*MT4 DRAPING 717LE: P.O. BOX 368 MATERIALSCF .IA UMWACRMC W_ 9" wniams me PwAm 10 DE PORCH ANCHORING SAFETY HARBOR. FLORIDA 34695 KOW RR SPEOM PAM NO NMI BE DRAWING NUMBER: PHONE (727) 726-1138 wi cwmoim me c-rwT nmu omm AD-TO-0112 64 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR DIAGONAL FRAME TIE )WN ANCHOR BRACKET ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. RAf1lU5 CLIP I� i I I_I I- I—) I I —III— RADIUS CUP MUST BE INSTALLED ON _ ALL T1E-DOWN ANCHOR BRACKETS ADIUS CUP ANCHORING EQUIPMENT —III I I I -I I I -I I BY (INSPLAY NG AOSTRAIGH 3 FABRICATE*LENGTH OF CAPABLE OF RESISTING -III-I I I —III— 1 1/4' X 0.03T TIE -DOWN STRAP THE WORKING LOAD REQUIRM ON THE MATERIAL IN ANCHOR SLOT AND BENDING TIE -DOWN SPACING I —III —III-I I TO FORM THE CONFIGURATION SHOWN.) TABLES (SET_ OTHER I— III —III— RADIUS CUP MUST BE INSTALLED TO PROTECT DETAILS FOR TABLES) THE TIE -DOWN STRAP FROM THE BRACKET EDGES. SEE OTHER DETAILS I INSTALL THE TIE -DOWN STRAP THROUGH THE SLOT FOR ANCHOR ANGLE. I I —I I I - III -I I IN THE BRACKET 'OH TO OF' THE RADIUS CUP. ``1111WIWIIIIIIIff/f��' N C. Doe'% NOTES: OVANO. O'•. 'y DAPIA APPROVAL 1. ALL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME - ENEfl70357 PROVED BY TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPL U�M BY AND INSTALLED BY OTHERS- ON SITE. r T.^. F/ r .)UN 1 5 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING O�; .• /STAY SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- �. 19 'J Ua .` . mmm 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS �i�fff1AL IL fT rAcri ++o q WHERE THE ANCHORING SYSTEM REQUIRES THE USE MICH BR HAND TIE - OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES N077C� DRAWN BY: DATE REV LETTER TI[SE SPEDIIGITIONS ANp oRArHcs ARE C.L.Y. 5-31-95 MONAL. PRMKTMY• AID 0711110ENTWAI DRAWING Dill: /� P.O. BOX 368 MATMMS OF 0+ YANAACARWC ALT. TIE -DOWN APPL. NC /- „ 9" MAYERKS ARE PRONGED TO THE SAFETY HARBOR, FLORIDA 34695 R104M MR VEOIX PWIWM AND W9 EE DRAWING NUMBER: PHONE (813) 726-1138 KO Cdf0EE M 00 saRt n= OWHIT& AD-TO-0200 APPROVED VERTICAL TIE —DI (FACTORY INSTALLED) CRIMP SEAL (3150/ WORKING LOAD) • C3 x iC i VERTICAL ME -DOWN 0 TYPE 1, FINISH B. w GRADE 1 STEEL STRAPPING 1 1/4' WIDE h 0.035' O IN THICKNESS, CERTIFIED BY ui A REGISTERED PROFESSIONAL ts 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR F FACTORY INSTALLED STRAP IS NOT LONG ENOUGH, IT MAY BE LENGIHENE•D BY USING A CRIMP SEAL WITH A WORKING LOAD OF 3150 POUNDS t� 0 t �J f DIACONAL FRAME TIE I —II ANCHORING EQUIPMENT _ CAPABLE OF RESISTINGI— THE WORKING LOAD REQUIRED ON THE TIE -DOWN SPACING TABLES (SEE OTHER DETAILS FOR TABLES) ' SEE OTHER DETAILS FOR ANCHOR ANGLE NOTES: 1. ANY ADDITIONAL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) IF NEEDED, USE VERTICAL TIE —DOWN TYPE 1, FINISH B, GRADE 1 STEEL STRAPPING 1 1/4' WIDE do 0.035' IN THICKNESS, CERTIFIED BY A REGSTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. r 910334 -a STATE ` F ci`r THESE SPEaT1 noN57 AND ��E UNAnN t JACOBSEN HOMES ORIONAL PRDI'METARY. AND COIITIDDITIAL DRAWING P.O. BOX 36B UATDDALS OF JAu CDBSEN MIUTACTI"C ®� INC. S1CN YATERIAS ARE PROVIDG TO INE SAFETY HARBOR. FLORIDA 34695 RIOPCNT Fat SPEIFIC PtBPOM AID UZI III ORAWIIIG PHONE (813) 726-1138 PUT CONI1DENTAL MO SEOST rROU ones R.R. DAPIA APPROVAL APPROVED BY ON00or REVISED INC. rtIw Ww s.eruaEo �a.e c:o asmuem+.No s�s¢n 9[mam E DATEREV. LETTER: ]0-05-96 ALT. TIE —DOWN APPI AD—JD-0210 66 ADDENDUM COLUMN TIE -DOWN APPLICATION I�COLUMN 'A' — — COLUMN 'B'�I SEE TABLE FOR MAMU SPAN FOR COLUMNS 'A' OR 'B' 1 COLUMN 'C' COLUMN b' SEE TABLE FOR MAXIMUM SPAN FOR COLUMNS 'C' OR b' SEE TABLE FOR SPAN COL 'E' SEE TABLE FOR MAX. SPAN FOR COL 'C' COLUMN 'E' j COLUMN *r COLliul SEE TABLE FOR MAMMUM SPAN FOR COLUMN r MAXIMUM ALLOWABLE SPAN TYPE OF ANCHORPIO REO'D COLUMNS 'A', 'C', b' OR 'E' COLUMNS V OR 'G' COLUMN i (SEE AD-M-0251. AD-TD-0252 AND ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD-ID-0253) SEE NOTE 1 EXP. 'C' EXP. b' EXP. 'C' EXP. b' EXP. 'C' EXP. b' W. 'C' EXP. b' EXP. 'C EXP. 'D' EXP. 'C I EXP. 'D' 2 - 31501 ANCHORS 43'-0' 29'-6' 33'-9' 2T-7' 4S-O' 29'-6' V-9' 23'-Y 4S-V 29'-6- 33'-9' 23'-7' 1 - 31501 ANCHOR 21'-6' 14'-9' 16'-10' 11'-10' 21'-6- 14'-9- 16'-10' 11'-1O' 21'-6- 14'-9' 16'-10' 11'-10' 1 - +000/ ANCHOR 27'-3' 16'-9' 21'-5' 15'-0' 27-3' I5'-9' 21'-5. 15'-O' 27-3- IV-9- 21'-5' 15,-0' NOTES' ENaNEER APPROVAL DAPIA APPROVAL' APPROVED 81(, 1. SEE AD-TD-0251, AD-TD-0252 AND AD-TO-0253 FOR SPECIFIC INFO. ON ANCHORS. 5 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR INSTALLATION. John C. Doeden, P.1, INC, 15133 C. R. 22 cnwwlm" wmrvQm Goshen, IN 46526 JACOBSEN HOMES P.O. BOX 368 NOTICE: THESE SPEaluna+S AND DRAVOICS ARE MGMAL PROPRR TARY, AND caaWU& MAT MATERIALS OF JACOM MANJfACTURDIG DRAW BY: C.L.Y. DATE: 5-31-95 REV. LEM n Domo DRAIHNG TITLE: CAL- — A ,I SAFETY HARBOR. R FLORIDAFLORIOA 34695 we sua YATERULS ARE FRONDED THE r RCl'>P[NI a sifllt PU8n4S Aro MUST aE /H` DRANNG NUMBER PHONE (013) 726-1138 IVT ra fMRk NO Start M OMM AD-TD-0250 67 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. 0 ANGLE SHOWN. ANCiORS INSTALLED 24- APART COLUMN STRAPS SEPERATE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI -WIDE ATTACHED ANCHORS _..,,111111111,... VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4" WIDE k 0.035" IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL, AND SEALS. 35' ANGLE TO TWO (3t5O# EA.) .Q STc No. Fo'?' EN"c8703571 s��NAt Ey�: AFF =... `,i`ED BY .1.IN 1 5 INC riDENIIYMfK7tA�N,E W67NA:71tf1A!OSN[11 WrOMn JACOBSEN HOMES AM '­RAWN BY: 'D. C.L.Y. °A'E' 5-31-95 REV. LETTER. THESE sKanCATMS OW DUUNM ■ P.O. BOX OIECINAL. PRdP1bETARY. AM LAW YDf1111AL MATERIALS OF JACOBSEM MAIANACTLREMC DRAWING TITLE: COL. TIE -DOWN APPL. n SAFETY HARBOR. FLORIDAI 34695 WCMAnIMS ARE PR Nc H OM= 10 THE REQE11r raR SP[= Puwom me mm K '1-�` DRAWING NUMBER: PHONE (813) 726-1138 IVT Col WIM AO SECRET TROY 0M AD- TD-0251 69 ADDENDUM COLUMN TIE -DOWN APPLICATION ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. MARRIAGE LINE OF WAII-'M.DE FLOOR II FLOOR 101 VERTICAL TIE -DOWN TYPE 1, FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' MADE k 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. COLUMN STRAPS ATTACHED TO A SINGLE GROUND ANC,HIO,R„A (315 0 #) NOTES' ENQ •• CC`O �i� DARA APPROVAL 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. �.�`� Q t,.S TFq q1 No. FO '? % PROVED BYE NE8� 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING _ SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— = JUN 1 5 10 ATION. 3. PROTECTION SHALL BE PROVIDED = INC AT SHARP CORNERS ��p' 6 4 �,4' WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL '�� ��'• NO) .•'•�� �.•` �i S `••••••'' ArrrasAwsA>tniwOvp STRAPS OR CABLES. E��.•�`�� NA JACOBSEN HOMES N0710E mm sPEOf1CATIW AND muRlltls AM ItRAW BY: C.LY. DAIS: 5-25-95. REV. LETIER DRANING 7I E: COL TIE -DOWN APPL. oB P.O. 80X 368 CMMAL. TRUAKT AND CM"MXTVL MATERIALS OF JACOM UWAnMC „ SAFETY HARBOR, FLORIDA 34695 PHONE (E13) 726-1138 NG 91W MATERIALS ARE PRONGED TO rE RECPENf FOR vEEi1C R1an4S NO MAI BE IQPT COKWRQ AM IOU r%N 0110M DRAIRNG NUMBER AD-TD-0252 69 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 4000 i MIN. COLUMN STRAPS SINGLE GROUND 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. 0 MARRIAGE LINE OF MULTI -WIDE FLOOR VERTICAL TIE -DOWN TYPE 1, FINISH B, 'GRADE 1 STEEL STRAPPING 1 1/4' WADE & 0.035' IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 03953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (4000#) . _..111111IIIIu,. No. ;yFo F N287 a OVED BYE, jM 1 51 T 1VIM INC cwal�ucla� eo sArt1'r swalR TTE JACOBSEN HOMES TIESE �OFICNOM"IfA AM DRAW= AM �Dw�w+er.. C.L.Y. uATE. 5-25-95 ��' � Pt aaarw.. PoPaIErARr, AID OOMIODITUI DRANWG nni P.O. BOX 368 1A1;;M% eDF '1AC0 " uANUTACTURwD COL. TIE —DOWN APPL. „ SAFETY HARBOR, FLORIDA 34695 � FCR SK� FU AM yAM PRDWO m K DRA/IWG NUMBER: PHONE (813) 726-1138 IVT CasoE IM NO YCRET Taa DT#M AD—TO-0253 70 ADDENDUM 184" WIDE COLUMN TIE -DOWN APPLICATION COLUMN 'A, COLUMN' -- - - - - - ISEE TABLE FOR MAMN SPAN FOR COLUMNS W OR r 'C' COLUMN b' /COLUMN APPROVED EY I I SFE TABLE FOR MA)mAlll SPAN FOR COLUMNS 'C' OR b' r SEE TABLE FOR SPAN COL •E' SEE TABLE FOR MAX SPAN FOR COI..I INC. FE0 L MANUFACTURED HOF1c RUCTIONAND SaTY STi.7DAROS MAR 0 3 1999 COLUMN 'E' COLUMN i COLUMN f ISEE TAEEE FOR MA)mw SPAN FOR COLUMN'r _ I MAXIMUM ALLOWABLE SPAN TYPE OF ANCHOIW REC D (SEE AD-71)-0251, COLUMNS W. V. b' OR 'E' COLUMNS b' OR 'C axLAm r ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD'7D-MI) SEE NOTE 1 DP. 'C DIP. V EXP. 'C' EXP. V EXP. 'C' DP. V DP. V EXP. V DP. 'C' EXP V EV. 'C' DP. V 2 - 31501 ANCHORS 31-4• 25-6' 29'-4' 2O'-4' 37'-4' 25-6' 29'-4' 20'-4' 37'-4' 25-6' 29'-4' 20'-4' 1 - 31501 ANCHOR 11t-6' 12'-10' 14•-7' 10'-3' 18'-6' 12'-10' 14'-7' 10'-3• 18'-6' 12'-10' 14'-7' 10'-3' 1 - 40001 MCHOR 2S-8' 16'-4' 18'-7' 13'-O' 2S-8' 16'-4' 18'-7' 13'-0' 23'-B' 16'-4' 18'-7' 13'-0• REF. CALCS c ✓ /� 93. Dla ... �c '•,� DAPUI APPROVAjAAQ OS INU 1. SEE AD-TD-0251, AD-TD-0252 AND AD-TD-0253 ;'Q� NO, FO'•.• AppRp�D BY FOR SPECIFIC INFO, ON ANCHORS. 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR 910334 - .: INSTALLATION. 1k OF : STATE ��,` �:,��'�F'�. 1� `� INC, DMA,.•• ' �n��M'°''°rrn'°"'n JACOBSEN HOMES wx sPcar>GNilaDAm ft o WAWNM A M•T DAB 2-9-99 REV. LETTM* ORAWNO MAE: OROW. PRPRIEURY, AND CONFWUr. MATERIALS OF 1ACOM MANUFACUJRNG 18eWIDE COL. TIE -DOWN APPL SAFETY HARBOR, FLORIDA 34695 YIC SUCH MAIERULS ARE FRONDED 10 UE REmm rOR spEam P ras me um GE ORAINNO EAAMBER: AD—TD-0254 PHONE (727) 726-I IM I"T ODNnoENUAL ARo mm nm DDm 71 ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE NOTE 2 A B C 24' URGE OPENING 24' SEE NOTE 1 .n_. ,ul ll r n6—wml jl wj ", m". BRACKETS (SEE TE-DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIM M SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MIUIMMUM OF 2'-0' (241 FROM EACH END OF THE UNIT. NOTES: ENCTPRoft. lo •, DAPIA APPROVAL: 1. URGE OPENING = ANY OPENING WIDER THAN MAX TE-DOWN SPACING ALLOWED.- 2 VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTIC4 TIE -DOWN SPAa r EN�8703571 ~�r — ROVED BY SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM TIE -DOWN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME ,�'•. //1 f ,�. �: ''�� .1U+1 1 5 1995 TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). F ��� ���• INC 3. INSTALL FRAME TIES AT ALL VERTICAL TE-DOWN LOCATIONS. DAlALT►��Nv���� 4. SEE AD-TD-0001 FOR ADDIIONAL REOUDHEMENTS ANaIOR BRACKET AND TIE -DOWN DEVICES ARE CERTFID BY 01HERS JACOBSEN HOMES TT�SE SPECInaNTI NSS � MAU= ARE DRAWN BY: C.L.Y. DATE 5-31-95 REV. LETTER: P.O. Box 36e „ CRIaNAI, PROPFEM. AND CONMENTIAL MATERIALS CF JACOBSEN MATATPACI"G NG SUCN YA1T70N5 ARE PROWOED TO THE DRAWING TITLE: TYP. SINGLE WIDE T/D SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REWINT rOR 9OIC p rm me am K IQP T CONIwTa AM =Fu TROT ores DRAWING NUMBER: AD-TD-0300 72 ADDENDUM TYPICAL MULTI- WIDE TIE -DOWN PLACEMENT SEE NOTE 2. A B C Fi 24' n n n .. ., n Ir COLUMN SUPPORT TIE -DOWN STRAPS REQUIRED AT COLUMN LOCATIONS ON EACH SIDE OF OPENiN S GREATER THAN 41T' IN WIDTH. MULTI -WIDE FLOOR SHOWN SEIW7ED FOR CLARITY [2j4' STANDARD VERTICAL BE -DOWN STRAPS OR ANCHOR BRACKETS (SEE BE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAWN SPACING ALLOWED). ALSO SEE NOTE 3. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS, INSTALL ALL TIE -DOWN STRAPS AS SHOWN IN THIS DETAIL. NOTES: I. LARGE OPENING = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED. 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPACING SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAIOMUM TIE -DOWN SPACING REOUItED ON THE APPROPRIATE VERTICAL/FRAME TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL WRTTCAL TIE -DOWN LOCATIONS. 4. SEE AD-TD-0001 FOR ADDITIONAL REQIAREMENTS. JACOBSEN HOMES „ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 STANDARD VERTICAL TIE -DOWN STRAPS OR ANOiOR BRACKETS TO BE INSTALLED A MAAMUY OF 2'-0' (24') FROM EACH END OF THE UNIT. ,�gRNnw R1A��� IT AOTRdCAM� NFQ �Z 'i� DAPIA �ENES70357J 5TAT�F, OF %s�ONA l �� ��•�`. DEVICES ARE CERTIFIED BY OTHERS THESE SPEOIRUITIOMS AND DRAUHM ARE 0 PCPRORAYYAUC0TiUO WG 9XH MATUMS ARE PROM D TO THE RTOVIT FOR 9[R7= PJPM APO YJST of OUT I:ONFt90 nk AIO Kau no Om 24' C.L.Y. 1 6-1-95 - - - TYP. MULTI -WIDE T/D A R. AD-TD-0310 73 SINGLE WIDE TIE —DOWN ZONE I TIE -DOWNS MARRIAGE WALL I OPENING TIE -DOWN I (REQUIRED AT OPENINGS ONLY. OPTIONAL AT SEE DETAIL - 'A' OTHER LOCATIONS) FRAME TIE -DOWN SEE DETAIL - 'B' Z DOUBLE WIDE TIE —DOWN NOTE` C SECTION I I MARRIAGE WALL NOTE: SIMILAR To I OPENING TIE -DOWN I A do B SECTIONS SINGLE WIDE SIMILAR TO DOUBLE (REQUIRED AT OPENINGS WIDE TIE —DOWN FRAME TIE -DOWN ONLY. OPTINAL OAT I OTHER LOCAnoNs.) IPULL DOWN TIGHT TO —/ GROUND ANCHOR DETAIL 'A' TRIPLE WIDE TIE —DOWN SEE DETAIL - 'A' SEE DETAIL - V TIE -DOWN STRAP SINGLE HEADED GROUND.ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TES ARE LOCATED AND SECURED TO THE SAME GROUND' BUCKLE WITH 2O251 ANaiOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) IY MINIMUM ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE TIE -DOWN STRAPPING (31So LBS. MAAMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TIE -DOWN STRAP (1 1/4' X .035' MINIMUM aNK COATED STEEL STRAP, OR EQUAL WITH SISo* CAPACITY MINIMUM) K I•S= 477,S M ULTi,,,,,F Loan o4rpCITy NOTES: ENfi, �` �� DAPIA APPROVAL: 1. SEE DETAIL PAGE q AOR MARRIAGE WALL q�, • + OPENINGS GREATER THAN 49 INCHES. d: VP To ICI 6" 'i�IgVTq : • 04' ���� : APPROVED BY %2. SEE TIE -DOWN SPACING CHART ON PAGE Z EDR 9� 2 ANCHOR AND TIE -DOWN PLACEMENT. 3. SEE DETAIL 'A' PAGE ROR TYPICAL I -BEAN INC PIER CONSTRUCTION. STATE OIF 11b 9CS •.s�RED EN � . pp�$p{�Tp1A105AIiTTSSMON'Cb REV JACOBSEN HOMES mm�� AMDRAM=ARE BY' RR °"� 10-31-95 'LETTER ■ OMOINAL. PROMETARY. AND OONFMTIAL DRAWING 717LE: YATERIAIS OF JACOM IUNLAACTANC �� P.O. BOX 368 WC 9XH YATERWS ARE PROI= TO THE ZONE I TIE -DOWNS SAFETY HARBOR, FLORIDA 34695 IMMUT FOR 9UM PllRO AM YAT K DRAWING NUMBER - HE (813) 726-1138 WT COIFOf1 Rk AO SECRET mm onm AD-Zl -0001 74 75 ZONE I TIE -DOWN PLACEMENT TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM `SFE NOTE #I�— MAIN FRAME I -BEAM END SPAONGI CENTER SPACING CENTER I SPACING CENTER I SPACING CENTER I SPACING CENTER SPACING END ISPACWCI DOUBLE WIDE TIE —DOWN PLACEMENT END CENTER CENTER CENTER CENTER CENTER END • WAUNU WAUMU TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM SEE NOTE 111 `SEE NOTE #1— MAIN FRAME I -BEAM MAIN FRAME I -BEAM I ICI SPACINGj S ACING END 1. TRIPLE WIDE TIE —DOWN PLACEMENT 10 IN DAPIA APPROVAL SEE DETAIL 'B' PAGE 4 FOR BLOCKING AND ANCHORING OF �� r��IFICgj:•`�ji APPROVED BY MARRIAGE WALL OPENINGS WADER THAN 49 INCHES. V F N0.0045484 .,ON p • *. , STATE OF * I e�?,�� FURAMws.auaowa NOMCF. '' '* DATE: REV. LETTER: JACOBSEN HOMES AN iHEsE sPEancA=m D oRAwNGs ARE ' RR 10-31-95 OMONAL PROPRIETARY. AND CdNn10 TA1 DRAWNG MU P.O. BOX 368 MATERIAs of JACOBSU MOXACIUINC TIE —DOWN PLACEMENT „ SAFETY HARBOR, FLORIDA 34695 �fpp q�pWERIALS AM M No WST � PHONE (813) 726-1138 IVT a71fMA& No Man n= omm DRAWWG NUMBER AD-Zi-0020 76 ZONE 1 INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET—UP MANUAL AND/OR THIS ADDENDUM. eY FEB 0 1 M INC. )HOME JACOBSEN TOMES NBC �`: M ORAL A �MM or UAIL M.T. 2-1-00 RV LLIILF CRIMP1. IROPOCTARY ua CQ WNlAt 1AVUALS Or ACOS "' """""""""` DRAWM nnE: ZONE 1 INST. „ P.O. BOX J68 SAFETY HAR80R, FLORIOA 3�695 RR VUV P n M NAU AK o mist R DRAWWG NUMBER: PHONE (727) 726-1138 W1 CCKM0 a M Matt MOM antes - AD-Zl-0100 77 ADDENDUM FOR INTERSECTING UNITS m Lei MAW UNIT /DORITER I \ MAXIMUM PIER HEIGHT FOR VAPoOUS ZONES (REFER ALSO TO SIDEWALL TIE-DOWS MAXIMUM HEIGHT. Z4bE2 ZONE EXPOSURE 'C' 90' 56" EXPOSURE V 39" 46' LONGITUDINAL TIES ONLY REOUIRED 0 EA. HALF OUTSIDE BEAM IRIS END, EXCEPT FOR ZONE 3 EXP.'D' THEN 2 REQUIRED EA HALF (IE. 014E EA. BEAM, ETC_.) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SIDEWALLS SAME AS THE MARL UNIT. VERTICAL TIES AT CENTER LINE REQUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE BIDE CONNECTION REOUIREMENTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END. OF THE UNIT (SAME AS TYP. DOUBLE MDE TIE -DOWN REOUIREMENTS). 2 LONGITUDINAL TIES REOUIRED AT EACH HALF INS END ONLY. CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTIONS) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED W THE SET-UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION, NO STRAPS ARE REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA) _.,U11111111 r... OT S: u+Lksxele,Uw ,KUv • ., IV -If, UANIA ANrKUYAU 1. FOR QUAD SECTIONS, EACH 'DOUBLE SECTION' OF THE UNIT SHALL BE DESIGNED • Q' N0. OAPPROVED BY/O ,.: INDEPENDENT OF THE OTHER STRUCTURE (IL SHEARWALLS, TIE -DOWNS, RIDGE- EN 0357 BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI -SECTION.) _ JUN 1 5 iM MIA INC �,� �s,' • • ........ • NV `� �,�,� „o SKEif swarss ONALr�E NOTICE DRAWN BY: DAIS REV• LETTER: JACOBSEN HOMES IHESE SPECNICATIONS AND DRAWNGS ARE C.E.Y. 5-16-95 WONAL PROPfMETARY. AND tWNFMWIA1 DRAWING TITLE: Et5i11 P.O. BOX 368 MATMALS OF JACOMM"ACIURING ADDENDUM -INT. UNITS SAFETY HARBOR. FLORIDA 34695 REMW FCR TECFE PJKM ND WS1THEBE PHONE (B13) 726-1138 IRPT CDNFMnk AND SECRET FROM ODM DRAWING NUMBER QUADADDI 78 ALT. ROOF ASSEMBLY FOR MULTI-WIDES CENTERI NE CONNECTION FOR QUAD UNITS IS THE SANE AS FOR THE MAIN UNIT (REFER TO SET-UP DETALS). 30 GA. GALV. STEEL STRIP INSTALLED OVER MUTING LINE JOINT (SEE PLAN NEW BELOW) ROOF PERD41M RAIL-� OR RIDGE BEAU CROSS-SECTION 30 GA. CAM STEEL STW e' x LENGTH OF ROOF ISECTIONS MAY BE OVERLAPPED 2 MIN.) W/STAPlES AS 9i0MN. INSTALL ROOF CAP PER SET- UP MAN. OVER GALV. STRIP. (SEE NOTE 1) 3/8' X S' LAG SCREWS 18' O.C. (ZONES 2 & 3) STAGGERED . �- 30 CA. GALV. STEEL STRIP SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION NTO DECKNG 2 " O.C. MAX SPACING (TIP.) tN11 U 111N NOTES ENaNt o pp� I.,,OALPIA APPROVAL 1. 30 GA. GALV. STRIPS USED MAY BE WAND DEFLECTORS ) . �, RF' • �i 'f+ L- :: _. c D L3Y REMOVED FROM ROOF INRIGN OAL CONDITION Q No. O y (EXCEPT FOR STAPLE HOLES] _ ENE8703571 JUN 1 5 IM STEEL STRIP MAY BE CDNTINNOUS OR PIECED. 2 SHINGLES IN THE DORMER AREA OF THE MAIN UNIT MAY INC,BE SHIPPED LOOSE AND INSTALLED ON SITE AFTER 1 '• / 1 THE UNITS HAYS BEEN ATTAM TO PREVENT ANY •��.` TRANSIT DAMAGE AND TO ENSURE THE 99NGLES UNE-UP FROM ONE SECTION TO THE NEXT.Nit • . �N�����` N077CE flit tomes . DATE REV. LETTER: 17=JACOBSEN HOMES TI[St SPECW.AMS AND IIAAttINGS AM C.L.Y. 5-16-95 MATO I. PLIOPrOETARW; faro 0OFACTL NG DRAWING TITLE'ALT. ROOF ASSEMBLY P.O. BOX 368 YAfE&0 a A ARE 4ANAFACTUROlO NG 9A7N YA1E7aAL5 ARE PRONGED TO 71K SAFETY HARBOR FLORIDA 34695 en>Port Fd1 V= NYNO NO Mal IIE DRAWLING NIMBEk PHONE (813) 726-1136 WT Oa MUAL AM SEOV rWa 000M QUADAD02 79 FTIFIF� E]EIEF EIVWFI LIEI JACOBSEN HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-113 8