HomeMy WebLinkAboutblower door:: Envelope Leakage Test Report (Blower Door Test) R U N B R OO K Residential Prescriptive, Performance or ERI Method Compliance GREEN BUILDING& ENERGY TESTING 2017 Florida Building Code, Energy Conservation, 6th Edition jurisdiction: Permit#:/Q—QQQ3 Job Information Builder: 7L 1110VA VIVlz/A/ Community: &e)4 y` Z, 9 7V�� Address: / 0en1,NI4 /j is C� Unit, Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method OPRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. P RfKRMANCE or ERI METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): CFM(50) Building Volume ACH(50) ❑FAIL ®When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume; ORetrieved from architectural plans �de software calculated OField measured and calculated Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3.lnterior doors, if installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: /�L�'/�'��� Phone: 00 —Cy09? I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature ofLter: e� %� Printed Name of Tester: 7 ML 4f: % le License/Certification #: i�07 07 ��Date of Test: � al 40 Issuing Authority: I.aRE[14 C3UILL) INU ti Er1EI1GY iFL2�TING Residential Prescriptive, Performance or ERI Method Compliance 2U I Florida Building Code, Energy Conservation, 6th Edition jurisdiction: Permit job Information Builder: IINAII wlCommunity Address; �-% Unit: City; ,Q� � State Ala/4- Zip: ,3�9�/ Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any dditional systems cfm25 Total of all systems cfm25 oPrescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. QPerformance / ERI Method cfm25 (out or Total) To qualify using this method, Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2017 or R40&2017. Qn I Leakage Type selected on Form Qn specified on Form R405-2014 T talfall Total Conditioned systems Square Footage R405-2097(Energy Colc)orR406-ZDi7 (EnergyCalc) or406-2097 PASS FAA L 1 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, Testing Company Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ate of Test: Z o7 07 Printed Name of Tester: