Loading...
HomeMy WebLinkAboutRevisionCeramic Tile STRUCTURAL NOTES: GENERAL ROOFING NOTES Shall be installed in accordance with ANSI All 08.1, A108.4, A108.5 A108.6, A108.11, A118.1, A118.3, A136.1, & A137.1. Fiber mat All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous Roofing to be composed of and attached to pre manufactured reinforced reinforcing 48 bar diameters or 30" in beams and in slabs. Lap wood trusses as follows: backer shall be used behind wall applied ceramic tiles in the tub bottom steel over supports and top steel at midspan. Hook 5/8- c.d.x, sheathing or equal installed with staggered joints and shower areas and conform to ASTM C1325. Per Durock, discontinuous ends of all top bars. Reinforcing steel shall have " nailed to trusses with 8d corrosion resistant annular ring shank nails cement board exceeds ASTM C 1325. a minimum of 1 concrete cover, or as follows: spaced max. 6"o.c. throughout, except max. 4" o.c. at gable ends. BOTTOM TOP SIDES All roof trusses are to be pre -manufactured assemblies provided by GG Note ypsum oe Beams: 1 1/2" 1 1/2- 1 1/2- a licensed wood truss fabricator with separate drawings and data prepared for actual project conditions by a Florida registered Gypsum board shall conform to ASTM C22, 0475, C514, C1002, C1047 Slab on Grade: 1 1/2 "" 1" _ professional engineer certified for truss design. Any deviation from the proposed plans as shown regarding placement or bearing shall C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential Structural Poured: 3/4" 3/4" _ be brought to the attention of the truss engineer prior to fabrication code. Per USG, Wallboard conforms to C1396. Poured Walls: _ - 3/4"" Slabs exposed of the trusses. The truss manufacturer's certified layout shall govern after fabrication. Gypsum Board &Gypsum Panel Products to the weather 3/4" 1- The handling, erection, and fixing of wood trusses shall be in Reinforcing steel shall be detailed and fabricated in accordance "Manual accordance with the specifications contained on the certified mfgr's. drawings and data. Gypsum board and gypsum panel products shall be applied with the of Standard Practice of Detailing Reinforcing at right angles or parallel to framing members. All edges and Concrete Structures" and the current " ACI Building Code 318- All engineered headers and truss hangers to be provided by the ends of gypsum board and gypsum panel products shall truss manufacturer. occur on framing members, except those edges and ends that All structural steel shall conform to current ASTM Specification A-36 Splitting or cracking of structural components due to installation of are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to All wood in contact with masonry shall be pressure treated or approved hardware is not permitted. weather or to water. separating material. g Unless otherwise noted, the installation of specified hardware shall Wall and ceiling gypsum board shall be fastened with screws All dimensions shall be verified in field by the contractor. If there are conform to the truss manufacturers installation instructions and standard practice. spaced at 12"o,c. Screws for attaching gypsum board and gypsum any discrepancies the Architect or Engineer shall be notified before proceeding. panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 andshall penetrate thewood not less than 5/8"" inch (15.9mm) Gypsum board and Gypsum panel No slump over 5'" shall be permitted for any structural concrete without Wire Lath Attachment products shall be attached to cold formed steel framing less the Architect or En approval. Engineer g than 0.033- 0mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 All Design and Construction shall be inaccordance with the current Over wood framing the paper backed wire lath shall be installed and shall penetrate the steel not less than 3/8" to 0.112- American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable over one layer of approved plastic (Imm to 3mm) thick shall be in accordance with ASTM C954 or local codes, house wrap. Lath shall be attached bugle head style in accordance with ASTM 1513. Screws for horizontal framing members with 1.5" attaching gypsum board or gypsum panel products to structural Structural Concrete shall attain a minimum ultimate compressive strength roofing nails and to vertical wood insulated panles shall penetrate the wood structural panle facing (Fc') in 28 days as follows: framing members with 6d common not less than 7/16-o.c. 01.1 mm). nails or I" roofing nails driven to Column Footing and Wall Footing: 3000 p.s.i. penetration of not less then 3/4- Gypsum board used as the base orbacker for adhesive application Column and walls from foundation to roof: see column schedule. of an inch, or 1- wire staples of ceramic tile or other required nonabsorbent finish material shall All other concrete: 3000 p.s.i. driven flush with the plaster base. conform to ASTM C1396, C1178, C1278. Use of water resistant gypsum backingboard shall be permitted on ceilings. Water p g Footing sizes and reinforcing are based on allowable soil bearing Staples shall have crowns not less than 3/4"" and shall engage not less resistant gypsum board shall not be installed over a Class 1 or Class 2 vapor retarder in a shower or tub compartment. Cut or capacity it of 2000 s All footings shall bear in virgin soil. If this y p.s.i. g g is not the case, the Architect or Engineer shall be notified before than three strands of lath and exposed edges, including those at wall intersections, shall be proceeding with the work. penetrate the wood framing members not less than 3/4-. The fasteners must sealed as recommended by the manufactuer. Water resistant gypsum backing board shall not used where there will be Timber (Heavy Timber Construction) penetrate the wood framing members not less than 3/4"". Fasteners be direct exposure to water, or areas subject to continuous high (a) Truss manufacturer shall submit a signed and sealed shop shall 7- o.c. max. humidity. drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other Cold Formed Steel Note structural components with hurricane anchors for wind uplift. Cold formed steel framing supporting gypsum board and gypsum All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1/360 max. deflection. panel products shall be not less than 1 1/4" (32mm) wide in the least dimension. Non Load bearing cold formed steel framing All bolted connections shall be 1/2" Cadmium plated or better. shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 Lag bolts to be used only in shear connections with minimum and ASTM C955, Section 8. 4- threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the Wood Framing Note internal thread diameter and shall not be hammer driven. Wood framing supporting gypsum board and gypsum panel Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations products shall be not less than 2- (51mm) nominal thickness in th least dimension except that wood furring strips not less than 1"" by 2"" (25mm x 51mm) nominal dimension shall be GENERAL REQUIREMENTS permitted to be used over solid backing or framing spaced not more than 24"o.c. (610mm) All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. EXTERIOR CEILING & SOFFIT NOTE General contractor is responsible for all labor, materials, utilities, testing, waste removal stora a securin of sit d t t /fr ' h Step Flashing alor Roof & Wall Inters Undedayme 7 Metal Roof Panels Roof Sheathir Roof F Grout filled cell with #5 g g e, accomo a ion, ransport elg t, 7/8- Stucco finish over 3/8- high ribbed galv. wire lath fastened to and all other cost related to the completion of this project., unless explicitly 8"" z 16" C.M.U. WITH CELLS FILLED framing members with No. 11 guage nails with 1 3/4" embed. with 3/8"" identified here. WITH GROUT & (1} #5 VERT. dia. head 6""o.c, max. edges to be tied and nailed at 9""o.c. DOWEL J Install one layer of 15# felt to framing prior to installing ribbed lath Owner is responsible for all municipal related charges such as impact a fees, and water connection, except building permit fees, which are to be 3 INTERIOR WALL FRAMING NOTE included in the construction bid. x non bearing walls to be 2 x 4 studs 24""o.c. General contractor to check all drawings for errors and ommissions and W& -�Interior P.T. 2 x 6 AT (3) SIDES OF Spruce, Pine, Fir (SPF) #3 Grade lumber or better bring them to the attention of the architect prior to starting any work, or OPENING, FASTEN TO BLOCK or metal studs (25 Ga.) Crimper may be used in ordering any materials of the respective division of work. If such errors AS NOTED. lieu of screws, and ommissions are not reported in writingto the architect, any resulting DOOR SIDES damages or costs shall be born entirely by the general contractor. BUCK ATTACHMENT NOTES c7 1/2" x 6" REDHEADS WITH MIN. Z Architect is not responsible for the contractors method or means of a 2" x 1/8"WASHER 12" FROM ENDS AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH construction. o AND 16"o.c. MAX.M TO BLOCK WITH 1/4" DIA. TAPCONS INTO C.B.S. O DOOR HEAD SET AT 6"" FROM CORNERS AND AT 12"o.c. MAX. General contractor is to keep the site in a clean and safe state through o out the course of construction. On building turnover, general contractor to 1/4- x 2 3/4'" TAPCONS STAGGERED I II f 24"o.c. 8x1 CBS Wall AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH c can a suraces so as to be free of dust, grease, stains, scuffs, etc. BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR "T- NAILS- 4" FROM ENDS AND 12" o.c. Unless otherwise noted, the installation of specified hardware shall USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION conform to the manufacturers instructions and standard practice. Garage Door Buck Data il All plans and drawings are not considered complete until they have been THRESHOLD NOTE reviewed and approved by the Building Department Alum. window and the buildingcorrosive resistant permit has been issued, frame At Entry door the max. hgth. of the threshold shall be 1/2" Bottom Cord of Truss SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at 6"o.c. field & 4"o.c. edges Zone 2R, 2E, 2N: 8d at 4-o.c. edges & field Zone 3R, 3E: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter:.131 Min. Length: 2.5" Min. Head Diameter:.280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Varies — Nailing Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6-o.c at supported panel edges and #8 gun nails at Co.c. at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4-o.c. EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges and #8 gun nails at 4"o.c. at panel top and bottom and 6"o.c. in field top plate 2"" gyp. d.w. studs 24-o.c Stud Grade :4 p.t. sill plate )od base ased Hard Coil Ws 12"o.c. max. 0.00' �—F.F.E. IIjI} Yam" Concrete Foundation Interior Wall Section Non Load Brng 2" dia. Galv Pipe Set ballard 12" from appliance Galv. Collar Galv. Cap W I ih (4) 1/4" x 2 1/4 Typical Conc. Tapeons Foundation Bollard Detail ....... rXUUI LU vvail ria5rung vetail CONCRETE BLOCK WALL Tapcon concrete 3/8"" continuous bead of srews installed as caulk (back bedding) behind specified in window shim to prevent liquid passage manufacturers product approval 1/4- struct. shi window sill set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish-, a Protecto LWM200 precast Coating on Outside face cone. sill and Janbs of Openings all Sides min. 8 Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction Typical Precast Conc. Sill Detail Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked 1 x 2 p.t. 24""o.c. wall section insulation type d.w. ypical 2 x 4 tud bearing Vail 2 x 4 p.t. stud fastened to filled cell with 1/2- dia. 6" long wedge bolt with 1 /8" x 2- washer 6- from ends and 24-o.c. sn 51 Attachment Detail 3/8" continuous bead of caulk (back bedding) behind - buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck CBS Exterior Wall Stucco Stop Set 2""min. from Finished Roof Step Flashing along , Roof & Wall Intersection Underlayment — Metal Roof Panels Roof Sheathing (3) Coat Stucco_ Finish Paper Backed Wire Lath on (1) Layer of House Wrap over 5/8" c.d.x. plywood fasten - as per Nailing Notes bD T c � L U­ J Two Ply Wall Girder Truss Stucco Stop Set 2"min. from Finished Roof 1 x 2 furring 16-o.c. on Girder provide RI I Batt insulation along wall girder 1/2-d.w. Roof Framing Roof to Wall Flashing Detail WOOD FRAME WALL CBS:: (2)2x4 Min. 1 1/4 embedment TOP a at windows and min. 1 1/2" embedment at a ° a sl. gl. doors SP4 16-c.c. a (6) 10d NAILS ° 1/2- drywall - (2) 2 x 12 HEADER stucco finish BOND TOGETHER perimeter caulk i WITH 16d AT 6"o.c 1/4"" max. struct. shim Attach p.t. bucks with 8d coil nails at caulk 1 2-o.c. attach as per Typ. Alum. window manufacturers jamb or slidingl glass product approvals doorjamb SPH4 AT EV NOTE: Method of attachment and Gunable sealants shall comply WITH (12) 10 p y with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked 4'-6- 4'-4- h of f �anaoeoJ Framing Detail at DGRF Truss See Connector Schedule pre engineered trusses 24""o.c. SP4 AT EVERY STUD (2) 2 x 4 plate WITH (6) 10d NAILS with SP4 with (6) 10d x 1 1/2" at each stud 4STA18 10d NAILS /2" gyp. d.w. 2 x 4 studs 16"o.c. 4 STUDS f 2 x 4 p.t. plate with SP4 with (6) 10d x 1 1/2" at each stud wood base K 4 P.T. 'LATE Window &Door Flashing Detail at CBS Wall a" " E ,r"kl, y" „ai Includes Buck Attachment Method see footing details 1/2" dia. wed6e bolt with 3" x 1/8 washer 7" embedment 24"o.c. Int. Brng. Wall Detail Q N C14 o M L t� W z d' M " J LL to co X _0 U) U CD WLO 000 33 '4 a,p,,,,v -J + LL Q � i; Z 11 � C)W D p > fn to O X .J 1 Yi > 4 W i .,,...ifs UJ co t N LL co 00 I �OZ cli 7 Q to t` ao a r*.sz M T revision 2/24/22 Roof to Wall Flashing Detail 3/15/22 Frame Roof to Wall Flashing & Plywd. Support Framing @ DGRF drawn s.l. checked sJ. date 11/29/21 scale as noted job number 21013 sheet A a c: iiz r I'. a