Loading...
HomeMy WebLinkAboutAPPRO VED, Green Engineering P-1GULFSTREAM H1150-R-A 136,000 BTU, 6.0 COP HEATER, 230VI60HZ, SINGLE PHASE, TITANIUM, 20-70 GPM DIGITAL, POOL/SPA HEAT PUMP CHECK VALVE AS NEEDED ,f-fir.--�--- 21' POOL WASTE PRESSURE GAUGE & RE7AIN ON SITE AIR RELIEF VALVE / JANDY VSFHP270AUT 2.7 THP FLOPRO VARIABLE SPEED PUMP 130 GPM @ 35 TDH SELF -PRIMING IWI APPROVED HAIR AND LINT STRAINER iP PUP0NHAIR& LINTSTRAINER I JANDY CS250250-SQUARE- (•-: �- - _ _ FOOT SINGLE ELEMENT 3-WAY AR7RIDGE FILTER N _ En T D v O D A m O m T N � � z r N T ' N SALTCHLORINATOR 3-WAY 3-WAY c D -- I ZZN G w v�Z e N n�Dn r Dz = z m z -;+ c> ooz x zmcrm z' r'I mnD> �;:f 3 6i N O T Z D a "� Z -:' z WATER BONDING FITTING m r W j O y+• A z m In m m :: ; PB•20081" UL LISTED 40YZ < D y m T • • PERMA CAST COMPANY cc rn . Yc z PIPING SCHEMATIC TDH CALLS' N.T.S. PIPIN(; P FITTINGS:10TDH FILTER: 10 TDH HEATER: 10 TDH CHLOR: 5 TDH TOTAL: 35 TDH APSPIANSrI-15 FLOW CALCULATIONS PER STANDARD: POOL WATER VOLUME 11,478 /360= 36GPM CALCULATED FLOW RATE. NOTE POOLS UNDER 13,000 GALLONS, THE CALCULATED FLOW RATE OR 36 GPM WHICHEVER IS GREATER =THE FILTRATION FLOW RATE IS THERE AND AUXILIARY LOAD ON THE FILTRATION PUMP? YES IF SO, WHAT IS THE CALCULATION AUXILIARY FLOW RATE: 72 GPM MINIMUM FLOW RATE 72 GPM (GREATER OF THE FILTRATION FLOW RATE OR THE AUX FLOW RATE IF THE AUX FLOW RATE IS POWERED BY THE FILTRATION PUMP) ALL LISTED BELOW PIPING IS FOR FILTRATION PUMP ONLY MINIMUM SUCTION PIPING SIZE @ 6 FPS 3 MINIMUM SUCTION BRANCH PIPE @ 8 FPS 3 MINIMUM RETURN PIPING SIZE @ 8 FPS 3 MINIMUM RETURN BRANCH PIPE @ 8 FPS 2 FILTER TYPE AND SIZE: CARTRIDGE 250 SF MINIMUM FILTER AREA PER FILTER FACTOR IN STANDARD 250 X.375 = 94 GPM (MAXIMUM FLOW THROUGH FILTER FACTOR: FILTER AREA X .375 (CART), X 2 (DE) OR X 1.5 (SAND) HEATER MAKE AND MODEL#: 136,000 GULFSTREAM H1150 GAS HEATER EFFICIENCY RATING: N/A (NO PILOT LIGHT) HEAT PUMP EFFICIENCY C.O.P.: 6.0 PUMP SELECTION AS LISTED ON CURVE A (A= <THAN 17,000 GAL OR C= > THAN 17,001 GAL) PUMP MAKE AND MODEL#: JANDYFLO PRO 2.7 HP VSFHP270 FLOW RATE 30 GPM 600 RPM (FLOW RATE MUST BE < OR = MAX FILTER FLOW RATE) PUMP CONTROLS= FILTRATION PUMP HAS NO AUX LOAD- STANDARD TIME CLOCK FILTRATION PUMP WITH AUXILIARY LOAD- CONTROL MODEL FOR LOW SPEED DEFAULT WITH 24HR BACKWASH VALVE: YES (IF YES, MUST BE 2" MINIMUM) APSP/ANSI-7 THIS DATA IS FOR THE: POOL SINGLE UNBLOCKABLE? YTWO OR MORE? N (IF SINGLE UNBLOCKABLE INDICATE MAKE AND MODEL NUMBER) DRAIN MAKE AND MODEL#: AQUASTAR 32" CHANNEL LISTED COVER FLOW RATE: 316 GPM SYSTEM FLOW RATE: 130 GPM METHOD DETERMINING FLOW RATE: MAX FLOW FROM PUMP CURVE PUMP MAKE AND MODEL#: JANDY FLO PRO 2.7 HP VSFHP270 SUCTION PIPING: BRANCH PIPING SIZE 3 INCH @ 6 FPS OR LOWER TRUNK PIPING SIZE 3 INCH @ 8 FPS OR LOWER �►'v �v�1 �u17ders YOU CAN DREAM IT WE CAN BUILD IT DRAFTED BY: G.S.M. Pool ❑esianed Especially For: GREEN, SERID & ALLISON 2373 DYER RD PORT ST LUCIE, FL 34952 DESIGNER MONIKA POLAK 32" AQUASTAR 32" CDFL CHANNEL DRAIN (316 GPM 3.9 FTISEC THRU GRATE- SINGLE UNBLOCKAFILE OR EQUAL J.iPLASTER — — FLOOR �_ -_ •MAIN DRAIN SUCTON LINE TIED TOGETHER AS SHOWN ABOVE - PIPE SIZE PER PLAN 1I2" ROCK BED CLOTH (RECOMMENDED) HYDROSTATIC RELIEF NOTE: 25.9 SQ IN OPEN AREA, 316 GPM = 3.9 FEET VALVE PERSECOND CHANNEL MAIN DRAIN DETAIL ALL POOL & SPA SUCTION INLETS SHALL BE PROVIDED WITH A COVER THAT HAS BEEN TESTED & ACCEPTED BY A RECOGNIZED TESTING FACILITY & COMPLY WITH ANSUASME A 112.19.8M. " SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS & WHIRLPOOL BATHTUB APPLIANCES ADJUSTABLE WEIR DECK �jl l SUCTION CLEANER LINE I ; • DETAIL BASKET :•• . _ �•i WATER LEVEL �:';~ _ �"•' VACUUM FITTING - •Y: NTH SELF -CLOSING SAFETY COVER SUCTION LINEWN (TO FILTER E"RrH' SKIMMER DETAIL N.T.S. PUMP FRAME FILTER TANK MOUNT 1 314" X 3116" TAP CON. -- - �I II PUMP rr�rd FILTER FIBERMESH MAY BE USED IN LIEU OF WWF ��- POOL PUMP, FILTER I�f ®IIII ANCHOR POINTS (TYP.) POOL EQUIPMENT A_NCHORI.NG & SLAB DETAIL SEE NOTES PAGE N.T.S. WAYNE MARKHAM SENNETT P.E. 957216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 1.0111 (954) B18-38251 waynWwmo-pe-gum IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED P-� SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES y�y11lIIII111 � RKHAM ���+� ,%PG r i�:• NO 57216 : -A 1 ' STATE OF ' UJ Z. ,pNA `1,�`t.