HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LEDYARD RESIDENCE Builder Name: Street: 775 VENTURE Permit Office: City, State, Zip: JENSEN BEACH, FL, Permit Number: owner: MEL--RY CONSTRUCTION Jurisdiction: Design Location: FL, West Palm Beach 1. New construction or existing New (From Plans) 9. Wall Types (1260.0 sgfL) a. Concrete Block - E)d insul, Exterior Insulation Area R=4.5 1101.30 ft' 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 158.67 ft' 3. Number of units, if multiple family 1 c. NIA R= fe 2 d. NIA R= I? 4. Number of Bedrooms 10. Ceiling Types (1134.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1134.00 ft' 6. Conditioned floor area above grade (ft) 1134 b. NIA R= ft2c. R= ft' NIA Conditioned floor area below grade (W) 0 11. Ducts R fe 7. W indam (145.0 sgft.) Description Area a Sup: Attic, Ret: Attic, AH: Garage 6 175 a. U-Factor: Sgl, U=1.07 145.00 ft' SHGC: SHGC=0.50 12. Cooling systems kBtuihr Efficiency b. U-Factor. NIA fN a Central Unit 29.6 SEER:16.00 SHGC: c. U-Factor. NIA ff SHGC: 13. Heating systems kBhuhr Efficiency d. U-Factor: N/A W a Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.000 ft. 14, Hot water systems Area Weighted Average SHGC: 0.500 a. Electric Cap: 40 gallons 8. Floor Types (1134.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1134.00 ft' b. Conservation features b. NIA R= ft' None c. NIA R= ft' 15, Credits Pstat Total Proposed Modified Loads: 29.24 PASSS Glass/Floor Area: 0.128 Total Standard Reference Loads: 37.26 1 hereby certify that the plans and specifications covered by Review of the plans and Q �vIAE Sr this calculation are in compliance with the Florida Energy specifications covered by this Cade. 'I calculation indicates compliance Energy Code. rwffs, m`„ 1 with the Florida K.. PREPAR D BY: Before construction is completed;` - DATE: this building will be inspected for compliance with Section 5,93.908 0# I hereby certify that this building, as designed, is in compliance Florida Statutes. �Db with the Florida Energy Code. OWNER/AG..... _ BUILDING OFFICIAL: ,j, ��, DATE: DATE: - 1129/201512:10 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Tide* LEDYARD RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1134 Lot # BlocIdSubDivision: Owner MEL-RY CONSTRUCTION Total Stories:I PlatBook: # or Units: i Worst Case. No street 775 VENTURE Builder Name: Rotate Angle: 0 Rotate yes County. MARTIN Permit Office: Ventilation: No City, State. Zip,. JENSEN BEACH', Jurisdiction: Whale House Fan: FL, FamliyType'. Single-family NewlEyisting: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design DallyTemp vDesign Location TMY Site Zone 97.5% 2.6% Winter Summer Degree Days Moisture Range — FL, West Palm Beach FL - WEST -PALM-BEAC 2 44 90 70 75 316 so Medium BLOCKS Number Name Area Volume 1 Blocki 1134 10206 SPACES Number Name — Area volume tfthen Occupants Bedrooms Infil ID Finished Cooled Heated Main 1134 10206 Yes 2 2 1 yes Yes yes FLOORS Flow Type Space Perimeter R-Value Area Tile Wood Carpet Tile Wood I Slab -On -Grade Edge Insulation Main 118ft 0 1134 ft2 0 0 11 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area color Abser. Tested — Tested Insul. (deg) 1 Hip metal 1228 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC # Type Ventilation Vent Ratio (11 in) Area RBS IRCC Full attic Vented 300 1134 ft2 N N CEILING Ceiling Type Space R-Value Area Framing Frac Truss Type Under Attic (Vented) main 30 1134ft2 0.11 Wood 112MOI 5 12:10 PM EnergyGaugeV USA - FlaReS201 0 Section 405A.1 Compliant Software Page 2 of 5 WALLS Adjacent Wail Space Cavity Width Height to Sheathing Framing Solar Below _ 1 N _ 2 E _ 3 S 4 W ^_ 5 N 6 W To Type Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Garage Frame -Wood Main Garage Frame -Wood Main 4.5 25 4.5 25 4.6 47 4.5 21 11 7 11 10 9 4 9 4 9 4 9 4 9 4 9 4 233.3 ft' 233.3 W 438.7 ft' 196.0 ftz 65.3 ft' 93.3ft' 0 0 0.75 0 0 0.76 0 0 0,75 0 0 0.75 0 0 0.75 0 0 0.75 0 0 0 0 0 0 DOORS # Omt Dow Type Space Storms U Value FtWid In Ft eighln Area 1 E insulated Main None A 3 6 8 20 W WINDOWS Orientation shown is the entered, Proposed orientation. V# watt Omt ID Frame Panes NFRC U-Factor SHGC Area Overhang Depth Separation Int Shade Screening 1 2 3 4 5 6 N 1 Metal Single (Clear) E 2 Metal Single (Clear) E 2 Metal Single (Clear) S 3 Metal Single (Clear) W 4 Metal Single (Clear) W 4 Metal Single (Clear) Yes Yes Yes Yes Yes Yes 1.07 0.5 1,07 0.5 1.07 0.5 1.07 0.5 1.07 015 1.07 0.5 16.0 ft' 15.0 ft' 4.0 ft' 90.0 ftz 16.0 ftz 4.0 ftz 6 ft 0 in 6 ft 0 in 6 It 0 in 6 ft 0 in 6 ft 0 in 6 it 0 in 6110 in None 6 ft 0 in None 6 ft 0 in None 6 ft 0 in None 6 ft 0 in Nate 6 It 0 in None None Note None None None Nate GARAGE # Flow Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation t 8oft' 9oftz 17ft 9ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1487.3 81.65 153,55 .345 8,7434 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat Nave COP. 1 27 kStuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 29.6 kBtuthr 688 cfm 0.75 1 sys4l -.--.NJ 1/29/2015 VAG PM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage FSEC Cert # Company Name System Model # Collector Model # Area Volume FEF ft' None None DUCTS , Supply _ / — Return — Air CFM 25 TOT CFM26 OUT ON RLF HVAC # Heat Cod v # Location R Value Area Location Area Leakage Type Handy 1 Attic 6 175 fN Attic 18 ft, Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programabie Thermostat: Y Ceiling Fans: Cooling ((jj Jan ((jj Feb Jan [X] Feb ((]] Mar [Xj Mar E Apr [ ] May (Xj Jun (X] Jul Apr ] May j I Jun E j Jul [X] Aug [ j Aug pA Sep I ] Sep [ j Oct Oct Oct [ j Nov Nov Nov (] Dec L1x11 Dec Dec Heating (X) Feb Mar [x� Apr I May [[ 1 Jun J Jul E [) Aug [ ] Sep (LX11 LLxxJJ Venting [[ 11 Jan [[ �� [[XX]] Thermostat Schedule: HERS 2006 Reference Hours 8 9 10 11 12 Schedule Type 1 2 3 4 5 6 7 Coding (WO) AM 80 80 78 78 78 78 78 78 78 78 8 78 78 78 Coding (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) PM 68 68 68 68 66 68 68 68 68 68 66 66 Heating (WEH) PM 68 68 68 68 68 68 68 68 68 68 68 66 66 1 /291201512:10 PM EnergyGaugeg USA - FiaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 775 VENTURE PERMIT #: JENSEN BEACH, FL, 1111AMnATMW RFQ1 111RIF-MIENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK 402A To be caulked, gasketed, weatherstripped or otherwise sealed. Air leakage Recessed lighting IC -rated as meeting ASTM E.283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 40214.2. 403.1 At least one thermostat shall be provided for each separate heating Thermostat Thermostat & and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. . ......... Ducts .. . ...... 403,2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. ............... . ....... —.- . . ..... Water heaters ....... . .. . .... 403.4 ... . ....... Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level_ ventilation Nomake-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = I HP shall have the capability of operating at two or more speeds. Spas & Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except. if 70%of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116113). Heat Pump Pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >1 OkW must be divided into two or more stages. ----------- Ceilings;;nee walls 05.2.1 R-19 space permitting. - 1129/2015 12:10 PM EnergyGauga USA- Flalkes201 0 Seddon 405A.1 Compliant Software Page 5 of 5