HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LEDYARD RESIDENCE
Builder Name:
Street: 775 VENTURE
Permit Office:
City, State, Zip: JENSEN BEACH, FL,
Permit Number:
owner: MEL--RY CONSTRUCTION
Jurisdiction:
Design Location: FL, West Palm Beach
1. New construction or existing New (From Plans)
9. Wall Types (1260.0 sgfL)
a. Concrete Block - E)d insul, Exterior
Insulation Area
R=4.5 1101.30 ft'
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=11.0 158.67 ft'
3. Number of units, if multiple family 1
c. NIA
R= fe
2
d. NIA
R= I?
4. Number of Bedrooms
10. Ceiling Types (1134.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1134.00 ft'
6. Conditioned floor area above grade (ft) 1134
b. NIA
R= ft2c.
R= ft'
NIA
Conditioned floor area below grade (W) 0
11. Ducts
R fe
7. W indam (145.0 sgft.) Description Area
a Sup: Attic, Ret: Attic, AH: Garage
6 175
a. U-Factor: Sgl, U=1.07 145.00 ft'
SHGC: SHGC=0.50
12. Cooling systems
kBtuihr Efficiency
b. U-Factor. NIA fN
a Central Unit
29.6 SEER:16.00
SHGC:
c. U-Factor. NIA ff
SHGC:
13. Heating systems
kBhuhr Efficiency
d. U-Factor: N/A W
a Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 6.000 ft.
14, Hot water systems
Area Weighted Average SHGC: 0.500
a. Electric
Cap: 40 gallons
8. Floor Types (1134.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1134.00 ft'
b. Conservation features
b. NIA R= ft'
None
c. NIA R= ft'
15, Credits
Pstat
Total Proposed Modified Loads: 29.24
PASSS
Glass/Floor Area: 0.128 Total Standard Reference Loads: 37.26
1 hereby certify that the plans and specifications covered by
Review of the plans and
Q �vIAE Sr
this calculation are in compliance with the Florida Energy
specifications covered by this
Cade.
'I
calculation indicates compliance
Energy Code.
rwffs, m`„
1
with the Florida
K..
PREPAR D BY:
Before construction is completed;`
-
DATE:
this building will be inspected for
compliance with Section 5,93.908
0#
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
�Db
with the Florida Energy Code.
OWNER/AG..... _
BUILDING OFFICIAL:
,j, ��,
DATE:
DATE: -
1129/201512:10 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Tide*
LEDYARD RESIDENCE
Bedrooms: 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 1134
Lot #
BlocIdSubDivision:
Owner
MEL-RY CONSTRUCTION Total Stories:I
PlatBook:
# or Units:
i
Worst Case. No
street 775 VENTURE
Builder Name:
Rotate Angle: 0
Rotate
yes
County. MARTIN
Permit Office:
Ventilation:
No
City, State. Zip,. JENSEN BEACH',
Jurisdiction:
Whale House Fan:
FL,
FamliyType'.
Single-family
NewlEyisting:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design DallyTemp
vDesign
Location
TMY Site Zone 97.5% 2.6%
Winter
Summer Degree Days Moisture Range —
FL, West Palm Beach FL - WEST -PALM-BEAC 2 44 90
70
75 316 so Medium
BLOCKS
Number
Name
Area Volume
1
Blocki
1134 10206
SPACES
Number
Name
—
Area volume tfthen Occupants
Bedrooms
Infil ID Finished Cooled Heated
Main
1134 10206 Yes 2
2
1 yes Yes yes
FLOORS
Flow Type
Space Perimeter R-Value
Area
Tile Wood Carpet
Tile Wood
I Slab -On -Grade Edge Insulation Main 118ft 0
1134 ft2
0 0 11
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
V#
Type
Materials Area Area color
Abser.
Tested — Tested Insul. (deg)
1
Hip
metal 1228 ft2 0 ft2 Medium 0.96
No 0.9 No 0 22.6
ATTIC
#
Type
Ventilation Vent Ratio (11 in)
Area
RBS IRCC
Full attic
Vented 300
1134 ft2
N N
CEILING
Ceiling Type
Space R-Value
Area
Framing Frac Truss Type
Under Attic (Vented)
main 30
1134ft2
0.11 Wood
112MOI 5 12:10 PM EnergyGaugeV USA - FlaReS201 0 Section 405A.1 Compliant Software Page 2 of 5
WALLS
Adjacent
Wail
Space
Cavity Width
Height
to
Sheathing Framing Solar
Below
_ 1 N
_ 2 E
_ 3 S
4 W
^_ 5 N
6 W
To Type
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
Exterior Concrete Block - Ext Insul Main
Garage Frame -Wood Main
Garage Frame -Wood Main
4.5 25
4.5 25
4.6 47
4.5 21
11 7
11 10
9 4
9 4
9 4
9 4
9 4
9 4
233.3 ft'
233.3 W
438.7 ft'
196.0 ftz
65.3 ft'
93.3ft'
0 0 0.75
0 0 0.76
0 0 0,75
0 0 0.75
0 0 0.75
0 0 0.75
0
0
0
0
0
0
DOORS
#
Omt Dow Type
Space
Storms
U Value FtWid
In Ft eighln
Area
1
E insulated
Main
None
A
3
6 8
20 W
WINDOWS
Orientation shown is the entered, Proposed orientation.
V#
watt
Omt ID Frame Panes
NFRC
U-Factor SHGC
Area
Overhang
Depth Separation Int Shade
Screening
1
2
3
4
5
6
N 1 Metal Single (Clear)
E 2 Metal Single (Clear)
E 2 Metal Single (Clear)
S 3 Metal Single (Clear)
W 4 Metal Single (Clear)
W 4 Metal Single (Clear)
Yes
Yes
Yes
Yes
Yes
Yes
1.07 0.5
1,07 0.5
1.07 0.5
1.07 0.5
1.07 015
1.07 0.5
16.0 ft'
15.0 ft'
4.0 ft'
90.0 ftz
16.0 ftz
4.0 ftz
6 ft 0 in
6 ft 0 in
6 It 0 in
6 ft 0 in
6 ft 0 in
6 it 0 in
6110 in None
6 ft 0 in None
6 ft 0 in None
6 ft 0 in None
6 ft 0 in Nate
6 It 0 in None
None
Note
None
None
None
Nate
GARAGE
#
Flow Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
t
8oft'
9oftz
17ft
9ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Best Guess
.0005
1487.3 81.65
153,55
.345
8,7434
HEATING SYSTEM
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
Nave
COP. 1
27 kStuthr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow SHR Block
Ducts
1
Central Unit
None
SEER: 16 29.6 kBtuthr 688 cfm 0.75 1
sys4l
-.--.NJ
1/29/2015 VAG PM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage 0.92 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
FSEC
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
ft'
None None
DUCTS
, Supply _
/
— Return —
Air
CFM 25
TOT
CFM26
OUT
ON
RLF
HVAC #
Heat Cod
v # Location R Value Area
Location Area Leakage Type
Handy
1 Attic
6 175 fN
Attic 18 ft, Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programabie Thermostat: Y
Ceiling Fans:
Cooling ((jj Jan ((jj Feb
Jan [X] Feb
((]] Mar
[Xj Mar
E
Apr [ ] May (Xj Jun (X] Jul
Apr ] May j I Jun E j Jul
[X] Aug
[ j Aug
pA Sep
I ] Sep
[ j
Oct
Oct
Oct
[ j Nov
Nov
Nov
(] Dec
L1x11 Dec
Dec
Heating (X)
Feb
Mar
[x�
Apr I May [[ 1 Jun J Jul
E
[) Aug
[ ] Sep
(LX11
LLxxJJ
Venting [[ 11 Jan [[ ��
[[XX]]
Thermostat Schedule: HERS 2006 Reference
Hours
8
9
10
11
12
Schedule Type
1
2
3 4 5 6
7
Coding (WO) AM
80
80
78 78 78 78
78
78
78
78 8
78
78
78
Coding (WEH) PM
78
78
78 78 78 78
78
78
78
78
78
78
Heating (WD) PM
68
68
68 68 66 68
68
68
68
68
66
66
Heating (WEH) PM
68
68
68 68 68 68
68
68
68
68
68
66
66
1 /291201512:10 PM EnergyGaugeg USA - FiaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10 Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 775 VENTURE PERMIT #:
JENSEN BEACH, FL,
1111AMnATMW RFQ1 111RIF-MIENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
402A
To be caulked, gasketed, weatherstripped or otherwise sealed.
Air leakage
Recessed lighting IC -rated as meeting ASTM E.283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 40214.2.
403.1
At least one thermostat shall be provided for each separate heating
Thermostat
Thermostat &
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
. .........
Ducts
.. . ......
403,2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
............... . ....... —.- . . .....
Water heaters
....... . .. . ....
403.4
... . .......
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation systems shall not exceed the minimum ASHRAE 62 level_
ventilation
Nomake-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = I
HP shall have the capability of operating at two or more speeds. Spas
& Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except. if 70%of heat from
site -recovered energy. Off/timer switch required. Gas heaters
minimum thermal efficiency=78% (82% after 4116113). Heat Pump Pool
heaters minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >1 OkW must be divided into
two or more stages.
-----------
Ceilings;;nee walls
05.2.1
R-19 space permitting.
-
1129/2015 12:10 PM EnergyGauga USA- Flalkes201 0 Seddon 405A.1 Compliant Software Page 5 of 5