Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HVAC Loads
Snodgrass Residence HVAC Load Calculations for MX11 It gjVAAC,ft6"3'CwnAL FTL AC LoADs Prepared By: Residential Energy Calds Friday, August 07, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. 4 Calculations are erformed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual p I p ILE a'•. f, Q A AMPF is, lost, - ResidentialA Light Commercial HVAC Loads _ Elite Software Development, Inc:' [Rhvac Residential Energy Calc's Snodgrass Residence � = Ppittaiintl ie-, FL -- 4983' "- - Page 2 Pro ect Report, Project Title: Snodgrass Residence Designed By: Stiles Engineering Group Project Date: Friday, April 17, 2015 Company Name: Residential Energy Calc's -`if vbk; Vtt tya a� Desi •�' rt. k kkk l K.F +7 i` - A:. J1 A T 'F''k , ti *Y,S, 'V 3"l 'y 1^� �0`� Y' '� (yd'Y,4Y �• �,1 2 4 f p A"n 3� d .. Reference City: Fort Pierce, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 m a� < � ..•.�:,.t Total Building Supply CFM: 1,279 CFM Per Square ft.: 0.716 Square ft. of Room Area: I 1,786 Square ft. Per Ton: 581 Volume (ft3) of Cond. Space: 14,284 Bu-ild�nLoadst .. - ..,,".. .. .. ].. , Mra Ku' . i`I o....,.R z-.1•E .T !" I•,X`X�-��'tJ: t .ri'C.i•,. . F. A� J k.::'-... .. .wrr..:. � 3Vl:i b, Yv,.. /°. . Total Heating Required Including Ventilation Air: 27,918 Btuh 27.918 MBH Total Sensible Gain: 28,525 Btuh 77 % Total Latent Gain: I 8,352 Btuh 23 % Total Cooling Required Including Ventilation Air: 36,877 Btuh 3.07 Tons (Based On Sensible + Latent) Notes 3�, �. A .. .. +.r r� i . ... - . � a �:4.: `#—a ..:v. a.. r,`i-.. e . a M-_ ..•r.+�. A x7 ,-:...,, a , .1-i:2; . ..0 . ,5' *_ ssr,.?'.`, s ..... -3 :nv_ . s .a..,., Fri Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2,. and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. mILE COPY C:\ ...\Snodgrass Residence. rh9 Friday, August 07, 2015, 12:57 PM it %pommermai n V^%o Loaas �mr ��nwar Miscel - System 1 In ut Dat Winter: Summer: Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: 'Maximum Velocity: Minimum Height: Maximum Height: 90 78 59% 50% 75 61.09 if Main Trunk Runouts Yes Yes Yes Yes 0.00300 0.01000 0.1000 in.wg./l00 ft. 0.1000 in.wg./l00 ft. 650 ft./min 450 ft./min 900 ft./min 750 ft./min 0 in. 0 in. 0 in. 0 in. Outside Air Data; Winter Summer Infiltration Specified: 0.380 AC/hr 0.200 AC/hr 90 CFM 48 CFM Infiltration Actual: 0.365 AC/hr 0.170 AC/hr Above Grade Volume: X 14,284 Cu.ft. X 14,284 Cu.ft. 5,217 Cu.ft./hr 2,431 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 8.7 CFM 41 CFM Total Building Ventilation-, 25 CFM 25 CFM ---System 1--- 1 Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.380 AC/hr (90 CFM), Construction: Average Summer Infiltration Specified: 0.200 AC/hr (48 CFM), Construction: Average fle 1 Return I Attic 16B 0.12 6 193 No FILE COP, C:\ ...\Snodgrass Reside nce.rh9 Friday, August 07, 2015, 12:57 PM Rhvac Rend®nt�al&tight Commercial HVAC Loads', Ehte Software,Development lnc Residentiai'EnerResidence" Rort;Saint Lucie;Pa e 4:` Load Preview Report Net ft.2 Sen Lat Net Sen SFlytg C9 Acs Duct Scope I Ton /Ton Area Gain Gain Gain Loss CFM CFM CFM Size Building i 3.07 581 1,786' 28.525 8,352: 36,877, 27,918 353 1279: 1279; System 1 3.07 581 1,786 28,525 8,352t 36 877 27,9181 353 1,279 1208 Ventilation 412, 1,038 -1,450 769 ! Duct Latent ------- - -... .. _....... - . __ .. 1,833 ---- 1,833 --..._ - - - - ......... _........ _ ...__ .- --- 'Zone 1 1,786 ; 28,113 i 5,482 ; 33,595 ; 27,149 , 3531279 1208 1-Bedroom 2 3,611 . 217 ' 3,828 ;_43, 164 ®-- 2-5 _ 2 Bath 2 - -195 - - 75 496 -- 39 --3,273 - 535 571 7 - 23 -_. - ----- 1 .._ -._- 3 Hall 1401 1,630, 155 1785 2,111 27 74 5 1-5 --- -- - 4-Dining - - 120: _ 170 - __ y -- - 191 2-5 5-tGtchen 2 2 002 725 1,83 91 1 833 24' 1-6 - _.._ ..._ ... 6-Uving 414 , . __..- _.. 6A87 _ .. 4_39 _...2,727.-- - - 7,326 6,652 ; W 313 3-6 7-Master Bedroom 225 4983, 1,349 6332. 5,206; 68M 227 3-5 8-Walk In Closet 128 1,0081 124 1 132 1,3641 18 46 1-4 9-Master Bath 96 1,1681 724 1 892 1,412 18 53 1-4 10-Laundry I 96 3,047.1,155, 4,202, 1,776 231139 2-5 11-Pantry T 55 520 385 905 , 803 . 10 i� -- 24 1-4 A I II I FIL�v C:\ ...\Snodgrass Residei ce.rh9 Friday, August 07, 2015, 12:57 PM Duct Size .Preview Room or I Source Minimum l Maximum l Rough. 1 Design j SPI Duct Duct Htg I CIg I Act. I Duct Duct Name Velocity I Velocity l Factor l L11001 Loss l Velocity Length Flow Flow Flow Size System I Supply Runouts Zone 1 1 -Bedroom 2 'Built -In 450 750' 0D1 0.1, 602.4; 43 164, 2-5 2-Bath 2 Built-In_ 450 0.1 258.8' 7i 23, 1-4 3-Hall Built-in 450, 7501 0,01 0.1 543.9 27 741 1_5 4-Dining Built In 450' 750' 0.01" 0.1, 460.6: 28: 126! 2-5 - ------------ 5-Kitchen Built In 450 750: 0.01 0.1 1 463.8: 24i 91! 1-6 6-Living Built In 450 750. 0.01 ---- - ----- --- 0.1, 531.9 W = 313 3-6 7-Master Bedroom Built In 450 ...... 750, 0.01 0.1 554.2, ..... ......... _1 .. 68 .... 227 3-5 8-Walk In Closet Built In 450 750 0.01: 0.1 525.3: 46. 1-4 9-Master Bath uIlt-In 450: 750, 0.01 - - --- - ------- 0.1 609 53, 1-4 IG-Laundry Built-in 450 750: 0.01 0.1, 508.3 23�= 139 2-5 II -Pantry 0.0 1 24 1-4 .... ........ ... . Other Ducts In System I . ...... .......... ........ . ... ........ . .......... — -- ---- Supply Main - Trunk I Built -In 660 900 0.003 0.1 852.7 353 1,279 12x18 Summary System 1 Heating Flow: Coolinq Flow 1279 CA ... \Snodgrass Residence.rW Frid&y-TAugust 07, 2015, 12:57 PM Rhvac - Residential_& Light. Commercial HVAC Loads Elite Software Development, Inc. ;Residential Energy'Calc's ' Snodgrass Residence g Port Saint Lucie, FL 34983 Pa e 6 Total Building Summary Loads Component "1 ISArea Sem Lat Sen ` Total' n©escri ENQuan Loss Gain Gain . Gain 1 D-cb-o: Glazing -Double pane, operable window, clear, 120.5 2,193 0 4,709 4,709 metal frame with break, y-value 0.65, SHGC 0.67 11D-cm-o: Glazing -Double pane, operable window, clear, 168 4,092 0 4,562 4,562 metal frame no break, u-value 0.87, SHGC 0.67 11 D: Door -Wood - Solid Core 42 458 0 426 426 13A-5fcs: Wall -Block, board insulation only, R-5 board 1406.3 4,136 0 2,260 2,260 insulation, filled core, siding finish 16A-20: Roof/Ceiling-Under Attic with Insulation on Attic 1785.5 2,451 0 6,124 6,124 Floor (also use for Kneel Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-19 insulation 20P1-19op: Floor -Over open crawl space or garage, 1785.5 2,549 0 909 909 Passive, spray foam insulation, R-19 open cell 1/2 lb. spray foam insulation, 5 inches in 2 x 10 joist cavity, any cover Subtotals for structure: i 15,879 0 18,990 18,990 People: 4 800 920 1,720 Equipment: 3,000 600 3,600 Lighting: 0 0 0 Ductwork: 8,595 1,833 6,935 8,768 Infiltration: Winter CFM: 87, Summer CFM: 41 2,675 1,682 668 2,350 Ventilation: Winter CFM: 25, Summer CFM: 25 769 1,038 412 1,450 Total Building Load Total': 27,918 8,352 28,525 36,877 ChecKer'.`...&ua'i..`tw" ,fir. f$$fi`.7'. '.,.• Total Building Supply CFM: 1,279 CFM Per Square ft.: 0.716 Square ft. of Room Area:l 1,786 Square ft. Per Ton: 581 Volume (ft3) of Cond. Space: 14,284 ,BuildingLoads:.,, Total Heating Required Including Ventilation Air: 27,918 Btuh 27.918 MBH Total Sensible Gain. 28,525 Btuh 77 % Total Latent Gain: I 8,352 Btuh 23 % Total Cooling Required Including Ventilation Air: 36,877 Btuh 3.07 Tons (Based On Sensible + Latent) °fix WAN ANAIN Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i i I i I I C:\ ...\Snodgrass Resdence.rh9 Friday, August 07, 2015, 12:57 PM :Rhvac - Residential & Light Commercial HVAC Loads Elite, Software Development, Inc.. Residential Energy Calds... Snodgrass Residence Port Saint Lucie, FL 34983 Page 8. Detailed Room Loads - Room 1 - Bedroom 2 (Average Load Procedure) Gereral'_,'' Calculation Mode: i Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 195.0 sq.ft. Supply Air: 164 CFM Ceiling Height: I 8.0 ft. Supply Air Changes: 6.3 AC/hr Volume: I 1,560.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 3 CFM Runout Air: 82 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 602 ft./min. Percent of Supply: 2 % Runout Air Velocity: 602 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.298 in.wgJ100 ft. Actual Summer Infil.: 5 CFM Item Area -U- . Htg Sen Clg Lat Sen: Description Quanti_ .. ., Value . _s H fM Loss HTM Gain, S -Wall-13A-5fcs 15 X 8 J 90 0.105 2.9 265 1.6 0 145 E -Wall-13A-5fcs 13 X 8 I 89 0.105 2.9 262 1.6 0 143 S -GIs-1 D-cb-o shgc-0.67 100%S 30 0.650 18.2 546 23.9 0 716 (2) 1 E -GIs-1 D-cb-o shgc-0.67 33%S 15 0.650 18.2 273 57.5 0 862 UP-Ceil-16A-20 15 X 13 195 0.049 1.4 268 3.4 0 669 Floor-20131-19op 13 X 15 195 0.051 1.4 278 0.5 0 99 Subtotals for Structure: 1,892 0 2,634 Infil.: Win.: 11.2, Sum.: 5.2 224 1.540 345 0.384 217 86 Ductwork: ; 1,036 891 Room Totals: I I _ _ 3,273 217 3,611 I I I I ILE '1' Y vOp, C:\ ...\Snodgrass Residence.rh9 Friday, August 07, 2015, 12:57 P.M Rhvac - Residential; Light Commercial HVAC Loads Residential Energy Cal. Elite_ Software.Pevelopment, Inc. Snodgrass Residence Port Saint Lucie, FL 34983 Page 9 Detailed Room Loads - Room. 2 - Bath 2 (Average Load Procedure) General: Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 5.0 ft. System Number: 1 Room Width: I 15.0 ft. Zone Number: 1 Area: 75.0 sq.ft. Supply Air: 23 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.3 AC/hr Volume: 600.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: i 1 Actual Winter Vent.: 1 CFM Runout Air: I 23 CFM Percent of Supply.: 2 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 259 ft./min. Percent of Supply: 2 % Runout Air Velocity: 259 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: i 0.078 in.wg./100 ft. Actual Summer Infil.: 1 CFM m Area � -U- Htg SenWF1ron Quanti Value HUTM Loss Gain" Gain E -Wall-13A-5fcs 5 X 8 40 0.105 2.9 118 1.6 0 64 U P-Ceil-1 6A-20 5 X 15 I 75 0.049 1.4 103 3.4 0 257 Floor-20P1 -1 9op 15 X 5 75 0.051 1.4 107 0.5 0 38 Subtotals for Structure: 328 0 359 Infil.: Win.: 2.0, Sum.: 0.9 40 1.550 62 0.375 39 15 Ductwork: 181 122 Room Totals: I I I I 571 39 496 I I I I Iow IOPIi ';M C:\ ...\Snodgrass Re i idence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac - Residential & Light Commercial HVAC Loads: 4. Elite: Software Development, Inc. Residential Energy Calc's Snodgrass Residence Port Saint Lucie, FL 34983 Pa a 10 Detailed Room Loads - Room 3 - Hall (Average Load Procedure) ,General r 50� Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 20.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 140.0 sq.ft. Supply Air: 74 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.0 AC/hr Volume: 1,120.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: I 1 Actual Winter Vent.: 2 CFM Runout Air: I 74 CFM Percent of Supply.: 3 % Runout Duct Size: 5 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 544 ft./min. Percent of Supply: 2 % Runout Air Velocity: 544 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.244 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area -U- Htg Sen Clg -Let Sen" AQescripton. ENto_ a Quanti Value HTM Loss HT M Gain Gain S -Wall-1 3A-5fcs 7 X 8 35 0.105 2.9 103 1.6 0 56 W -Wall-13A-5fcs 13 X 8 I 83 0.105 2.9 244 1.6 0 133 S-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 W-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 UP-Ceil-16A-20 20 X 7 140 0.049 1.4 192 3.4 0 480 Floor-20P1 -1 9op 7 X 20 i_ 140_ 0.051 _ 1.4 200 0.5 0 71 Subtotals for Structure: 1.,197 0 1,166 Infil.: Win.: 8.0, Sum.: 3.7 160 1.538 246 0.388 155 62 Ductwork: 668 402 Room Totals: I I I I 2,111 155 1,630 I FILE COP C:\ ...\Snodgrass Res idence.rh9 Friday, August 07, 2015, 12:57 PM I - Residential & Light Commercial HVAC Loads '06rt.Saint Elite Software Development, Inc. �Rhvac Residential Energy'Calds _ . : Snodgrass Residence' Lucie FL 34983 Rage 11 Detailed Room Loads - Room 4 - Dining (Average Load Procedure) G 101 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: j • 12.0 ft. System Number: 1 Room Width: 10.0 ft. Zone Number: 1 Area: 120.0 sq.ft. Supply Air: 126 CFM Ceiling Height: I 8.0 ft. Supply Air Changes: 7.9 AC/hr Volume: 960.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 2 CFM Runout Air: 63 CFM Percent of Supply.: 2 % Runout Duct Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: I 461 ft./min. Percent of Supply: 2 % Runout Air Velocity: 461 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: I 0.176 in.wg./100 ft. Actual Summer Infil.: 4 CFM item Area -U- Htg Sen Clg Lat Sen ®escrzi U. n Quanti Value HTM Loss HTM Ga_ in . Gain E -Wall-13A-5fes 10 X 8 57.5 0.105 2.9 169 1.6 0 92 N -Wall-13A-5fcs 12 X 8 96 0.105 2.9 282 1.6 0 154 E -GIs-1 D-cb-o shgc-0.67 33%S 22.5 0.650 18.2 409 57.5 0 1,293 UP-Ceil-16A-20 12 X 10 I 120 0.049 1.4 165 3.4 0 412 Floor-20P1 -1 9op 10 X 12 _ 120 _ 0.051 1.4 171 0.5 0 _ _ 61 Subtotals for Structure: 1,196 0 2,012 Infil.: Win.: 8.8, Sum.: 4.1 176 1.540 271 0.386 170 68 Ductwork: 680 681 Room Totals: I I 2,147 170 2,761 I I I I I I I VILE COr"Y C:\ ...\Snodgrass Res idence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac -Reside & Light Commercial HVAC Loadsa Residential Energy Calc's Port Saint Lucie, FL 34983 Elite_Softwarwl)evelopment; Inc., Snodgrass Residence: Pa a 12 Detailed Room Loads - Room 5 = Kitchen (Average Load Procedure) ;.General _ � Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 16.1 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: I 241.5 sq.ft. Supply Air: 91 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.8 AC/hr Volume: I 1,932.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: I 91 CFM Percent of Supply.: 2 % Runout Duct Size: 6 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 464 ft./min. Percent of Supply: 2 % Runout Air Velocity: 464 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: I 0.138 in.wg./100 ft. Actual Summer Infil.: 3 CFM item Area -U- Htg Sen egg Lat Sens Description Quantit Value HTM Loss HTM . Gain Gain E -Wall-13A-5fcs 16.1 X 8 128.8 0.105 2.9 379 1.6 0 207 UP-Ceil-16A-20 16.1 X 15 I 241.5 0.049 1.4 331 3.4 0 828 Floor-20P1 -1 9op 15 X 16.11 241.5 0.051 1.4 345 0.5 0 123 Subtotals for Structure: 1,055 0 1,158 Infil.: Win.: 6.4, Sum.: 3.0 129 1.537 198 0.388 125 50 Ductwork: 580 494 Equipment: 600 300 Room Totals: I i I I I 1,833 725 2,002 I I I ' I Q\ ...\Snodgrass Res idence.rh9 Friday, August 07, 2015, 12:57 PM ,Rhvac - Residential & Light Commercial HVAC.Loatls 'Elite; Software Development, Inc., ' Re'sidential Energy CaIds Snodgrass Residence Porr'SainflLucie; FL 34983 Page 13 Detailed Room Loads - Room 6 - Living (Average Load Procedure) 'General Calculation Mode: I Htg. & clg. Occurrences: 1 Room Length: 23.0 ft. System Number: 1 Room Width: I 18.0 ft. Zone Number: 1 Area: I 414.0 sq.ft. Supply Air: 313 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.7 AC/hr Volume: I 3,312.0 cu.ft. Req. Vent. Gig: 0 CFM -Number of Registers: 3 Actual Winter Vent.: 6 CFM Runout Air: I 104 CFM Percent of Supply.: 2 % Runout Duct Size: I 6 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 532 ft./min. Percent of Supply: 2 % Runout Air Velocity: I 532 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: I 0.181 in.wg./100 ft. Actual Summer Infil.: 3 CFM .Item Area -U- Htg Sem Clg Lat Sen bescri tion . Qu_antit _ Value HTM Loss HTM Gain Gain_ N -Wall-13A-5fcs 18 X 8 i 16 0.105 2.9 47 1.6 0 26 N -GIs-1 D-cm-o shgc-0.67 100%S 128 0.870 24.4 3,118 27.2 0 3,476 (2) UP-Ceil-16A-20 23 X 18 414 0.049 1.4 568 3.4 0 1,420 Floor-20P1-19op 18 X 23 414 0.051 1.4 591 0.5 0 211 Subtotals for Structure: 4,324 0 5,133 Infil.: Win.: 7.2, Sum.: 3.4I 144 1.542 222 0.382 139 55 Ductwork: 2,106 1,699 Equipment: 300 0 Room Totals: I I 6,652 439 6,887 I I I I FILE � Y;� Q\ ...\Snodgrass Relsidence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac - Residential Light Commercial HVAC Loads Elite Software. Development, Inc., Residential;Energy.Uds Snodgrass Residence, Port"Saint Lucie, FL 34983 Page 14 Detailed Room Loads - Room 7 - Master Bedroom (Average Load Procedure) �General -�`} Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: I 15.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 225.0 sq.ft. Supply Air: 227 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 7.6 AC/hr Volume: 1,800.0 cu.ft. Req. Vent. Clg: 0 CFM -Number of Registers: 3 Actual Winter Vent.: 5 CFM Runout Air: I 76 CFM Percent of Supply.: 2 % Runout Duct Size: I 5 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 554 ft./min. Percent of Supply: 2 % Runout Air Velocity: I I 554 ft./min. Actual Winter Infil.: 18 CFM Actual Loss: 0.253 in.wg./l00 ft. Actual Summer Infil.: 8 CFM Item Area -U- Htg Sen Clg Sen' LatW Descri tion Qua. nt Value . HUTM Loss HTM Gainain:. N -Wall-13A-5fcs 15 X 8 90 0.105 2.9 265 1.6 0 145 E -Wall-13A-5fcs 15 X 8 80 0.105 2.9 235 1.6 0 129 W -Wall-13A-5fcs 15 X 8 120 0.105 2.9 353 1.6 0 193 N -GIs-1 D-cb-o shgc-0.67 100%S 30 0.650 18.2 546 23.9 0 716 (2) E -GIs-1 D-cm-o shgc-0.67 100%S 40 0.870 24.4 974 27.2 0 1,086 UP-Ceil-16A-20 15 X 15 225 0.049 1.4 309 3.4 0 772 Floor-20P1 -1 9op 15 X 15 225 0.051 1.4 321 0.5 0 115 Subtotals for Structure: 1 3,003 0 3,156 Infil.: Win.: 18.0, Sum.: 8.4 360 1.542 555 0.383 349 138 Ductwork: I 1,648 1,229 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 0 Room Totals: I 5,206 1,349 4,983 I I I 1LE COPY C:\ ...\Snodgrass Rei idence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac - Residential & Light Commercial HVAC Loads , Elite Software Development, Inc. Residential Energy Calds Snodgrass Residence, Port Saint Lucie, FL 34983 Pa a 15 Detailed Room Loads - Room 8 - Walk In Closet (Average Load Procedure) '�Geme�al y Calculation Mode: I Htg. & clg. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: I 128.0 sq.ft. Supply Air: 46 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 1,024.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: I 1 Actual Winter Vent.: 1 CFM Runout Air: I 46 CFM Percent of Supply.: 3 % Runout Duct Size: I 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 525 ft./min. Percent of Supply: 2 % Runout Air Velocity: I 525 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.311 in.wg./l00 ft. Actual Summer Infil.: 3 CFM Item Area -U"d Htg Sen Clg Lat 'Sen<' ®escription Quantit Vdalue HTM Loss HTM Gain Gain' W -Wall-13A-5fcs 16 X 8 128 0.105 2.9 376 1.6 0 206 UP-Ceil-16A-20 16 X 8 I 128 0.049 1.4 176 3.4 0 439 Floor-20P 1 -1 9op 8 X 16 I 128 0.051 1.4 183 0.5 0 65 Subtotals for Structure: 735 0 710 Infil.: Win.: 6.4, Sum.: 3.0 I 128 1.539 197 0.383 124 49 Ductwork: i 432 249 Room Totals: I I I I I 1,364 124 1,008 I I I I FILE COPY C:\ ...\Snodgrass Residence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac Residential & Light Commercial HVACLoads ResidentiaCEnergy Calc's ., `. Elite Software Development, Inc. Snodgrass Residence_ ..Port Saint Lucie, FL 34983 Page 16 Detailed Room Loads - Room 9 -Waster Bath (Average Load Procedure) sGeneral A �'= Calculation Mode: I Htg. & clg. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 6.0 ft. Zone Number: 1 Area: 96.0 sq.ft. Supply Air: 53 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.2 AC/hr Volume: j 768.0 cu.ft. Req. Vent. Clg: 0 CFM 'Number of Registers: I 1 Actual Winter Vent.: 1 CFM Runout Air: 53 CFM Percent of Supply.: 2 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 609 ft./min. Percent of Supply: 2 % Runout Air Velocity: 609 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: I 0.417 in.wg./100 ft. Actual Summer Infil.: 3 CFM gltem Area. -U= Htg Sen ' Clg ` Sens LatW,.'_ ®;e5cription Quanti Value .:. ,. HTM Loss Hl M Gain, Gain', W -Wall-13A-5fcs 16 X 8 120 0.105 2.9 353 1.6 0 193 W -GIs-1 D-cb-o shgc-0.67I82%S (2) 8 0.650 18.2 146 32.5 0 260 UP-Ceil-16A-20 16 X 6 96 0.049 1.4 132 3.4 0 329 Floor-20P1-19op 6 X 16 96 0.051 1.4 137 0.5 0 49 Subtotals for Structure: j 768 0 831 Infil.: Win.: 6.4, Sum.: 3.0 128 1.539 197 0.383 124 49 Ductwork: I 447 288 Equipment: 600 0 Room Totals: 1 1,412 724 1,168 I i IUN I FIL E J U COP Q\ ...\Snodgrass Risidencexh9 Friday, August 07, 2015, 12:57 PM Rhvac - Residential s& Light Commercial HVAC Loads, Residential Energy Cal, Is EliteSoftware Development, Inc.` Snodgrass Residence' Port .Saint Lucie, FL 34983 Page 17 Detailed Room Loads - Room 10 - Laundry (Average Load Procedure) 'General �`• Calculation Mode: i Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: I 12.0 ft. Zone Number: 1 Area: I 96.0 sq.ft. Supply Air: 139 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 10.8 AC/hr Volume: I 768.0 cu.ft. Req. Vent. Clg: 0 CFM 'Number of Registers: 2 Actual Winter Vent.: 2 CFM Runout Air: I 69 CFM Percent of Supply.: 1 % Runout Duct Size: 5 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 508 ft./min. Percent of Supply: 2 % Runout Air Velocity: 508 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.213 in.wg./100 ft. Actual Summer Infil.: 4 CFM ttem Area -U- Fitg Sen Clg Lat Sen yDescription Quanti Value _.__ HTM Loss Hl M Gain. 0 G_ ain W-Wall-13A-5fcs 8 X 8 49 0.105 2.9 144 1.6 0 79 S -Wall-13A-5fcs 12 X 8 96 0.105 2.9 282 1.6 0 154 W -GIs-1 D-cb-o shgc-0.67 33%S 15 0.650 18.2 273 57.5 0 862 UP-Ceil-16A-20 8 X 12 96 0.049 1.4 132 3.4 0 329 Floor-20P1 -1 9op 12 X 8_ 96 0.051 1.4 137 0.5 0 49 Subtotals for Structure: 968 0 1,473 Infil.: Win.: 8.0, Sum.: 3.7 160 1.538 246 0.388 155 62 Ductwork: 1 562 752 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 600 300 _ Room Totals: I I I I I i I I I I i I I I 1,776 1,155 3,047 C:\ ...\Snodgrass Ri sidence.rh9 Friday, August 07, 2015, 12:57 PM Rhvac - Residential;$ Light Commercial HV4C Loads. Elite Software Development, -Inc.' Residential Energy Ealc's. �"ObrtSain4t :Snodgrass Residence , Lucie, FL 34983 ' - Page 18` Detailed Room Loads - Room 11 - Pant (Average Load Procedure) Geheral� Calculation Mode: I Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: i 5.0 ft. Zone Number: 1 'Area: 55.0 sq.ft. Supply Air: 24 CFM Ceiling Height: I 8.0 ft. Supply Air Changes: 3.2 AC/hr Volume: 440.0 cu.ft. Req. Vent. Clg: 0 CFM *Number of Registers: I 1 Actual Winter Vent.: 1 CFM Runout Air: 24 CFM Percent of Supply.: 3 % Runout Duct Size: I 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: I 271 ft./min. Percent of Supply: 2 % Runout Air Velocity: 271 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.085 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area -U- Htg Sen Clg Lat Sen . ®escription Qua,'; Value HTM Loss HTM Gain Gain S -Wall-13A-5fcs 11 X 8 88 0.105 2.9 259 1.6 0 141 UP-Ceil-16A-20 11 X 5 55 0.049 1.4 75 3.4 0 189 Floor-20P1 -1 9op 5 X 11 55 0.051 1.4 79 0.5 0 28 Subtotals for Structure: i 413 0 358 Infil.: Win.: 4.4, Sum.: 2.1 88 1.545 136 0.386 85 34 Ductwork: I 254 128 Equipment: 300 0 Room Totals: 803 385 520 I I i I I I I i FILE II COPY C:\ ...\Snodgrass Ri sidence.rh9 Friday,. August 07, 2015, 12:57 PM i Rhvac -'Residential & Light Commercial HVAC'Loads , Elite'' Software Development, Inc. Residential Energy'Calds . Snodgrass Residence Port Saint Lucie FL 34983 Page 19 S stem 1 Room Load Summary g . Min, Run Run Clg ` Clg .. _ . •Mina :Act Room Area Sens Htg Duct Duct Sens Lat Clg � S.y'�s F,No,:: ---Zone 1- 1 Bedroom 2 I 195 3,273 43 2-5 602 3,611 217 164 164 2 Bath 2 75 571 7 1-4 259 496 39 23 23 3 Hall I 140 2,111 27 1-5 544 1,630 155 74 74 ^ 4 Dining 120 2,147 28 2-5 461 2,761 170 126 126 5 Kitchen I 242 1,633 24 1-6 464 2,002 725 91 91 6 Living 414 6,652 86 3-6 532 6,887 439 313 313 7 Master Bedroom 225 5,206 68 3-5 554 4,983 1,349 227 227 8 Walk In Closet i 128 1,364 18 1-4 525 1,008 124 46 46 9 Master Bath 96 1,412 18 1-4 609 1,168 724 53 53 10 Laundry 96 1,776 23 2-5 508 3,047 1,155 139 139 11 Pantry 55 803 10 1-4 271 520 385 24 24 Ventilation I 769 412 1,038 Duct Latent 1,833 System 1 total j _ 1,786 27,918 353 28,525 8,352 1,279 1,279 System 1 Main Trunk Size: 12x18 in. Velocity: I 853 ft./min Loss per 100 ft.: 0.102 in.wg Coohn �S ,stem�Sumnia" . • #^ ,. ....tea. .Y "s *c�' �`K.h„'1:WI , C6.oling Sensible%Latent , ` Sensible Latent . Total�n ;x,; Tons Slit . Btuh Btah. Btuhd Net Required: 3.07 77% / 23% 28,525 8,352 36,877 Actual: 3.33 79% / 21% 31,500 8,500 40,000 E ui" ment.Data... n .fit.. s%ix ,zr ,arc,.;^ ;n . r4 , Heating System Cooling System Type: I Two Speed Heat Pump Standard Air Conditioner Model: RXBH24A10J RPQL042JEZ Indoor Model: RHLLHM4821JEZ Brand: PRESTIGE PRESTIGE Description: HEAT PUMP HSPF 9.5 16 SEER Efficiency: Hi: 9.5 / Lo: 0 HSPF 16 SEER Sound: 0 0 Capacity: 40,000 Btuh 40,000 Btuh . Sensible Capacity: n/a 31,500 Btuh Latent Capacity: i I I I n/a 8,500 Btuh I I� J FILE COPY I C:\ ...\Snodgrass Re i idence.rh9 Friday, August 07, 2015, 12:57 PM