Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 A FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method J Project Name: Treasure Coast Air Park Street: Fort Pierce City, State, Zip: Fort Pierce , FL , Owner: Design Location: FL, ST_LUCIE_CO_INTL Builder Name: Permit Office: Fort Pierce Permit Number: Jurisdiction: 661100 County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeP260.0 sqft.) a. Concrete Block - Int Insul, Exterior Insulation Area R=7.0 3260.00 ft2 2. Single family or multiple family Detached b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 d. N/A R= ft2 4. Number of Bedrooms 3 11. Ceiling Types (1270.0 sqft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Vented) R=38.0 1270.00 ft2 6. Conditioned floor area above grade (ft2) 2540 b. N/A R= ft2 R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R ft2 7. Windows(240.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: ahul 6 280 a. U-Factor: Sgl, U=0.65 240.00 ft2 SHGC: SHGC=0.45 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr E fficiency SHGC: a. Central Unit 78.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 5.100 ft. a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average SHGCa 0.450 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap: 1 gallons 9. Floor Types (1270.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1270.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, CV, Pstat Total Proposed Modified Loads: 70.96 PASS Glass/Floor Area: 0.094 Total Baseline Loads: 78.66 I hereby certify that the lans and specifications covered by Review of the plans and this calculation are in c r�lp hbblth wyllorida Energy specifications covered by this Code. �,®� ® �'• °� ��,�� calculation indicates compliance co '' �� with the Florida Energy Code. PREPARE Y'� Before construction is completed DATE: d this building will be inspected for compliance with Section 553.908 I hereby certify thaaii u' d' g, a*s designed, is in Compliance Florida Statutes. with the Florida Ea) Q1A1NE"/AGE �` ?qA� o �y pit®A BUILDING OFFICIAL: All DATE: DATE:' zYD we -i/-,ill_ r-%%n' \.- - Compliance requires cWr(i#tgat1ggjh�he air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project envelope leakage test report with envelope leakage no greater than 5.90 ACH50 (R402.4.1.2). 8/23/2021 3:25 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software O� F=nRnn Ran-_gngn INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Treasure Coast Air Park Bedrooms:. 3 User Conditioned Area: 2540 Total Stories: 2 1 Worst Case: No Rotate Angle: 0 Fort Pierce Cross Ventilation: Yes 661100 Whole House Fan: No Detached New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: Fort Pierce County: St. Lucie City, State, Zip: Fort Pierce , FL, CLIMATE / v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium' BLOCKS Number Name Area Volume 1 Block1 2540 20320 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 2 ahui ahu2 1270 10160 Yes 6 1270 10160 No 6 1 2 1 Yes Yes Yes 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ahu1 200 ft 0 1270 ft2 ____ 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (d09) 1 Gable or shed Barrel tile 1376 ft2 138 ft2 Medium N 0.96 No 0.9 No 0 22.02 .::. ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full cathedral ceilin Vented 300 1270 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Vented) ahu2 38 Blown 1270 ft2 0.11 Wood 8/23/2021 3:25 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 c FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo 0 Ornt Space 10 Wall lype R-Vall le Ft In Ft In Area 13-Vaille Fraction Ahsor r-qde% _ 1 N Exterior Concrete Block - Int Insul ahul 7 55 0 10 550.0 ftZ 0 0.75 0 2 E Exterior Concrete Block - Int Insul ahul 7 52 10 520.0 ftz 0 0.75 0 3 W Exterior Concrete Block - Int Insul ahul 7 52 10 520.0 ftz 0 0.75 0 4 S Exterior Concrete Block - Int Insul ahul 7 55 0 10 550.0 ftz 0 0.75 0 5 N Exterior Concrete Block - Int Insul ahu2 7 68 0 10 680.0 ftZ 0 0.75 0 _ 6 E Exterior Concrete Block - Int Insul ahu2 7 22 0 10 220.0 ft' 0 0.75 0 7 W Exterior Concrete Block - Int Insul ahu2 7 22 0, 10 220.0 ftz 0 0.75 0 • DOORS # Ornt Door Type Space Storms Width U-Value WidthArea Ft In Ft 1 E Insulated ahul Metal .46 6 7 42 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Clear) Yes 0.65 0.45 Y 21.0 ftZ 2 ft 0 in 0 ft 0 in Drapes/blinds None ' 2 E 2 Metal Single (Clear) Yes 0.65 0.45 Y 84.0 ftZ 10 ft 0 in 0 ft 0 in Drapes/blinds None ; 3 W 3 Metal Single (Clear) Yes 0.65 0.45 Y 36.0 ft2 4 ft 0 in 0 ft 0 in Drapes/blinds None 4 N 1 Metal Single (Clear) Yes 0.65 0.45 Y 36.0 ftZ 2 ft 0 in 0 ft 0 in Drapes/blinds None 5 N 5 Metal Single (Clear) Yes 0.65 0.45 Y 21.0 ftz 2 ft 0 in 0 ft 0 in Drapes/blinds None' 6 E 6 Metal Single (Clear) Yes 0.65 0.45 Y 21.0 ftZ 2 ft 0 in 0 ft 0 in Drapes/blinds None 7 W 7 Metal Single (Clear) Yes 0.65 0.45 Y 21.0 ft' 2 ft 0 in 0 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed SLA .0003 1996.6 109.73 205.65 .1406 5.8955 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts.; 1 A Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 ;: 1 B Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 A Central Unit/ Split Singl SEER: 16 42 kBtu/hr 1260 cfm 0.75 1 sys#1 1 B Central Unit/ Split Singl SEER: 16 36 kBtu/hr 1080 cfm 0.75 1 sys#1 8/23/2021 3:25 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 s FnRMQ4f15-9n90 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless ahul 0.97 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply --- ---- Return ---- Air CFM 25 CFM25 HVAC #, # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Ggol 1 Attic 6 280 ft2 Attic 89 ft2 Default Leakage ahul (Default) (Default) 1 1W TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan Feb [ Mar XMar Apr Apr May May X Jun Jul f j Jun jXjJul Au rj Au Se SeP ri [ ] [ ] Oct Oct Nov Nov HX Dec'. Dec' H Ventin Jan Feb [X Mar [X] A r [ Ma [ Jun Jul Aug Se [Xl Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12. •.. Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80, ' PM 80 80 78 78 78 78 78 78 78 78 78 7§' Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78- PM 78 78 78 78 78 78 78 78 78 78 78 78" Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 65 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 168 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 ahul Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 ahu2 3 8/23/2021 3:25 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. Fort Pierce, Fort Pierce, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=7.0 3260.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Vented) R=38.0 1270.00 ft2 6. Conditioned floor area (ft2) 2540 b. N/A R= ft2 c. N/A R= ft 7. Windows— Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=0.65 240.00 ft2 a. Sup: Attic, Ret: Attic, AH: ahu1 6 280 SHGC: SHGC=0.45 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 78.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 5.100 ft. Area Weighted Average SHGC: 0.450 8. Skylights Description Area 15. Hot water systems Cap: 1 gallons a. U-Factor AVG : N/A ( ) ft2 a. Electric EF: 0.97 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1270.00 ft2 Credits (Performance method) CF, CV, Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection erwise, a new EPL Display Card will be completed based on installed Code corn ' nt f ures. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/23/2021 3:25 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1