HomeMy WebLinkAboutNOA- Metal Roofing SystemROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 7th Edition (2020)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer:
Notice of Acceptance Number: /(i - 083 0.03
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:— Zone 2e: — Zone 2n: Zone 2r: — Zone 3e:--' Zone 3r:
Deck Type:
Type Underlayment:
Roof lope:
12
Insulation:
Fire Barrier:
Ridge Ventilation?`!Fastener Type & Spacing: �1 �"P!%� u / s "/—/)x0�/* 90 s
/Q,6 a2 rows /l A ac .
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: %s r Roof Covering:
Type & Size Drip Y3
Edge:
476 FLORIDA BUILDING CODE — BUILDING, 7th EDITION (2020)
MIAM4®i4E�
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/eeonomv
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Image II Metal Roofing System
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0107.04 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0830.03
Expiration Date: 08/08/23
Approval Date: 09/20/18
Page 1 of 5
ti
ROOFING SYSTEM APPROVAL:
Category: Roofing
Sub -Category: Metal, Panels (Non -Structural)
Material: Steel
Deck Type: Wood
Maximum Design Pressure -127.5 psf
y TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions Specifications
Description
Image H Metal Roof L = varies' TAS 110
Corrosion resistant, galvanized, preformed,
W = 12" and 16"
coated, prefinished, metal panels.
H= 1"
Min. Thickness 0.019 inch
Min Yield Strength: 64 ksi.
Trim Pieces L = varies
W = varies
Min. Thickness 0.019 inch.
MANUFACTURING LOCATION:
1. Jacksonville, FL
EVIDENCE SUBMITTED:
TAS 110 Standard flashing and trim pieces.
Manufactured for each panel width.
Test Agency
Test Identifier
Test Name/Report
Date
Akzo Nobel Coatings
ASTM B 117
01/24/11
ASTM G23
01/24/12
PRI Construction Materials
VLS-005-02-01
ASTM B 117
02/22/13
VLS-004-02-01
ASTM G 26
02/22/11
PRI Construction Materials
MSMS-006-02-01
Sealant Weathering
09/12/07
MSMS-006-02-02
11/14/07
Architectural Testing
01-43798.01
TAS 100
03/6/03
PRI Construction Materials
MSMC-005-02-01
TAS 100
06/06/07
MSMC-014-02-02
TAS 125
12/03/13
Farabaugh Engineer & Testing,
T183-05
TAS 125
08/09/05
Inc.
T241-07
TAS 125
07/23/07
NOA No.: 18-0830.03
Expiration Date: 08/08/23
Approval Date: 09/20/18
Page 2 of 5
APPROVED ASSEMBLIES:
System A:
Deck Type:
Deck Description:
Maximum Uplift
Pressure:
IMAGE II Metal Roof Panel 12" or 16" wide panel
Wood, Non -insulated
New Construction 19/32" or greater plywood or wood plank.
See Table A below.
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
"/32") the above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1 %4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with Metal Sales Manufacturing Corporation's current published installation instructions.
Metal Panels and
Install the "IMAGE II Panels" and accessories in compliance with Metal Sales
Accessories:
Manufacturing Corporation's current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed in
compliance with the minimum requirements provided in Roofing Application Standards RAS
133.
Panels shall be fastened to substrate at the male end with one corrosion resistant #10 PHWS
fasteners sufficient length (but not less than 1") to penetrate through the sheathing a
minimum of 3/16", at a spacing not exceed 6" o.c. (See detail herein). Fasteners shall be
placed parallel to the roof slope.
TABLE A
Field
Perimeter and Corner'
Maximum Design Pressure
-102.7 psf
-127.5 psf
Enhanced Fastening
None
3/8" bead of Schnee -Morehead
SM7108 adhesive in the sidejoint.
See detail herein
1. Extrapolation shall not be allowed
NOA No.: 18-0830.03
Expiration Date: 08/08/23
Approval Date: 09/20/18
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and comers).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
CMLAAADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MIAMaDADE COUNTY
1APPROVED1
NOA No.: 18-0830.03
Expiration Date: 08/08/23
Approval Date: 09/20/18
Page 4 of 5
PROFILE DRAWING:
IMAGE II METAL ROOF PANEL
, 1
#10 PHWS fasteners
16" Wide Panel
Field Condition Details
12" or 16"
DETAIL A
END OF THIS ACCEPTANCE
3/8" Bead of Schnee-
--Vorehead SM7108
#10 PHWS fasteners
16" Wide Panel
Perimeter and Corner Condition Details
NOA No.: 18-0830.03
Expiration Date: 08/08/23
Approval Date: 09/20/18
Page 5 of 5