Loading...
HomeMy WebLinkAboutProduct Approval - Modified Bitumen Roof SystemQuality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) 215/2021 lr Maw E }� ,a T�xai t �x Oil,�jEp§����«`dTTa� eels Home Loa in user Registration Hot'ropics ; Product Approval USER: Public User Florida Building Code Online TIC 4 ttfM NIA .Submit Surcharge. Slats & Facts Publications 1 Contact Us Bcts SR'e map l Links ` Search ' FILE COPY r�tic(�{rprnygl M„,y > ! n.rtp;;;t 1t,I,1;£attytl,+�urca > > Application Detail FL It Application Type Code Version Application Status Comments Archived Product. ManUfaCtUrer Address/Phones/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL1654-R27 Revision 2020 Approved REVIEWED FOR CODE COMPUANCE ST. WCIE COUNTY BOCC P� POLYGLASS USA 1111 W, Newport Center Drive Deerfield Beach; FL 33442 (454) 233-1330 Ext 242 malpert@polygtass.com Maury Alpert malpert@polyglass.com TECH REP 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866) 802-8017 uspolyglasstechnical@polyglass.com QA REP 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglzissteclinical@polyglass.com Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation( Report Florida License PE-59166 UL LLC 11/07/2022 ]ohm W, Knezevich, PE Validation Checklist - Hardcopy Received FLT6!i4 R27 C..O�, 202.0 O1 C:OT f1TEMTNEN,pt1f. Standard Yam ASTM D4601 2012 ASTM D4897 2009 ASTM D6162 2015 ASTM 06163 201.5 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 https:llwww.goridabuilding.org/prlpr app_dtl.aspx?param=wGEV.XQwtDgvgqu2w%2bnFgUPv2pw6pKxAhNlxQbXaKmD3x9HjyQAYxuQ%3de/d3d 1/2 Florida Building Code Online 216/2021 1 ASTM G155 2013 FM 4470 2016 FM 4474 2611 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/02/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/12/2020 Date Approved 12/15/2020 Summary of Products FL # Model, Number or Name Description 1654.1 Polygiass Modified Bitumen Roof SBS and APP modified bitumen roof systems Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1,654 R27 II 2020 09 30 FINAL Al ER PG MODBIT FL3654- Bz.Luf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nleminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application relates Evaluation Reports to one particular assembly over concrete deck. Refer to the FI 1654 R27 AE 2020.09 30 FINAL ER PG MODBIT F1,3654- S2Z.Rdf ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits of Use. 3.) Refer to FL16717 Created by Independent Third Party: Yes for HVHZ jurisdictions. 0acl: nowt Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850.487-1824 The State of Florida is an AA/EEO employer. Cilaydoht 2007-2013 State of Florida.:: Privacy Statement :: Accesslbllity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.467.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an small address If they have one. The emails provided may be used for official commpnlcation with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts; Cred1 CaW:, Safe:, hops://www.floridabuilding.orgtprlpr app_dil.aspx?param=wGEVXQwtDgvgqu2w%2bnFbUPv2pw6pKxAhNlxQbXaKmD3x9HjyOAYxuQ%3d%3d 2/2 216/2021 Florida Building Code Online s ;; a vca aap Y { a r k r u i z st x zt t` TW ' 3 � al F tit �1�R�1 ��,�tl'9#" &L.,-:.'t,« ..;^ .,. -- >i�=• .wlZtit. ;t (gr «"•`r"il�.:: a a i 3u..�.a=saa e, i'is;.w..nav:si firrau+. [t...n;al.,ifti�.r. m:tx....aea7x2 d�b OCIS Home # Log In User Registration ? Hot Topics I Submit surcltaroe Stats 8 Facts Publications .i Contact Us I r1C(s site Ptap I Unks j Search 1 :Product,Approval '�',` �f All USER: Public User Po•nn{[£L ;(1i;{gny:�l hjenit > Qlodact <sr AR61lit Almon yry'ct[1+.> Application List Search Criteria R,nne _-strcii Code Version 2020 FL# ALL Application Type ALL Product Manufacturer POLYGLASS USA Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Prod uct'Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications IF r . rypP ..... -._. _._........... .... ...... ............ _.............. Mir I rt to _....... ........ _.... M_... Vy(�?teti [iYS _ a 1 Ft 1.651 R27 Revision 1 POLYGLASS,USA John W. Knezevich, PE Approved `i history Category Raofing (954) 772-6224 I Subcategory Modified Bitumen Roof System i F59-1131 Revision I POLYGLASS USA John W. Knezevich, PE Approved Hisrciry- Category. Roofing (954) 772-6224 Subcategory Underlayments ............. _ PL5259-R32 Revision _.... POLYGI.ASS:USA John W. Knezevich, PE. Pending FBC Approval Category: Roofing (954) 772-6224 LWI Subcategory: Underlayments ... ......... ... _ 10291-R16 Revision :POLYGLASS USA John W. Knezevich,.PE Approved History Category: Roofing (954) 772-6224 Subcategory: Cements -Adhesives -Coatings i FL]6.187-114 _ History. L�_15, 29-Rll Revision Revision POLYGLASS.USA Category: Roofing Subcategory:'Liquid Applied Roof'Systems POLYGLASS,USA Category: Roofing History Subcategory; Modified Bitumen Roof System .......... ...._ ..._.,.. FL167'17-R10 Revision 'POLYGLASS.USA dlCY Category: Roofing _..____ t Subcategory Modified Bitumen Roof System ........ ....._......... . _ . _... FL16718-R8 Revision POLYGLASS USA Category: Roofing iSubcategory: System i tort' Modified Bitumen Roof Fy1:Q73 R5 Revision POLYGLASS USA i5ir ry j Category: Roofing Subcategory: Cements -Adhesives -Coatings John W. Knezevich, PE Approved (954.)772-6224 John W. Knezevich, PE (954) 772-6224 John W. Knezevich, PE i Approved (954) 772-6224 1. Jahn W. Knezevich PE Approved (954) 772-6224 John W. Knezevich, PE Approved' (954) 772-6224 FL-169ZA:R41 Revision POLYGLASS,USA i John W. Knezevich, PE Approved History I Category: Roofing (954) 772-6224 i Subcategory Liquid Applied Roof Systems F129260 R1 Revision POLYGLASS USA Jahn W. Knezevich, PE Approved Jlistop Category: Roofing (954) 772-6224 Subcategory: Spray Applied Polyurethane Roof System.! Contact Us ;:- 2601 Blair Stone Rnad, Tallahassee Ft. 32.392Phone: 050.407-1024 The State of Florida Is an WEE empinyen Copyright 2007.2013State of Florida: is Privacy Statement.::. AccessiAilitti Statement :: Ij�fu17d 5 a m Under I7orida'law, omail addresses ato publir..recorrls, It you do not Want your a -mall :address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone qr by traditional mail. It you. have any questions, please contact BS6.407,1395. •-Pursuagt to Section 455.2I5(l), Florida Statutes, effective October 1, 2072, licensecs•licdnsed under.Chapter 455, F.S.-must provide the Department with an email address:if they have one. The &mails provided may be used (or.official coinmiinication with the licensee, However email addresses are publi6 record, It you do not rash to supply a personal address, please provide the:Depar rm"It.with an email address yrhich can be made available to the public. Tit determine If you are a licensee under Chapter 456 FS., please click here Mips://www.foridabuilding.orrg/pr/per app_Ist.aspx 112 (NNEMOjet-c. m. TABLE. 'DECK APPLICATION" ":TYPE DESCRIPTION" PAGE'. .2A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-12 1C Wood New, Reroof (Tear -Off) or A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12-14 1D Wood New. Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded TopInsulation, Bonded Roof Cover 14-IS 1E Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 15-19 1F Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19-23 1G Wood New or Reroof (Tear -Off) 2 Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 23-29 1H Wood New, Aeroof (Tear -Off) or Recover E=2 Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 29-3E ^ 11...... _..Woad _'.... _..._.... New orReroof (Tear -Off) . ... _ ,.... ..F - Non -Insulated, Bonded Roof Cover. - ?A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-i Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 38-43 2B ` ` "Steel or.Structural concrete New, Reroof (Tear -Off) or'Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 44-50 2C SteelorStructural concrete New,:Reroof,(Tear-Off) or Recover D-2 Insulated, Mech. Attached Base'Sheet, Bonded Roof Cover Si-53 2D Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Velociflex, Bonded Rodf Cover 53-55 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded'insulation, Bonded Roof Cover So-6S 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 68 4A Lightweight concrete Now. or Reroof (Tear -Off) A4 Bonded Insulation, Bonded Roof Cover 69-73 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 7347 4C Lightweight concrete New or Reroof (Tear -Off) E-2 Non-Insulated,.Nlech. Attached Base Sheet, Bonded Roof Cover 74-78 5A Cementitious wood fiber Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 79-80 56 Cementitious wood fiber Reroof (Tear -Oft) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof'Cover 80-82 5C Cementitious wood fiber Reroof_( Tear -Off) or Recover B-1 Mech, Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 82 SO Cementitious wood fiber Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded'Roof'Cover 83 5E Cementitious wood'fiiber Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech.,Attached Base Sheet, Bonded, Roof Cover 83 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 84;88 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Miiech. Attached Anchor'Sheet, Bonded Insulation, Bonded Roof Cover 88 6C Existing gypsum Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 88 6D Existing gypsum Reroof (Tear -Off) or Recover E-2 Non4risulated, Mech. Attached Base Sheet, Bonded. Roof Cover 88 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 89;94. 7B Various Recover F Non -insulated, Bonded Roof Cover 94 NEMO ETC, LLC 'Evaluation Report P9290.02.08-R25 for FLln"54-1127 Certificate of Authorization "32455 7"1 EDITION (2020) PBC NON-HVHZ EVALUATION Revision 25: 09130/2020 02018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 94 O.MEM01 etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation hereimperrains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Fasteners shall be of sufficient length for the following engagements: 'r Wood Deck: Minimum 1-inch plywood penetration or wood plank embedment. Steel Deck: Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. y Structural Concrete Minimum 1-inch embedment into pilot hole in accordance with published installation instructions. Unless otherwise nwed,.insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimurn 2-inch thick FBC Approved lightweight insulating concrete may, be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-I or D-2, wherebv fasteners are installed throughthe ligh�weight insulating concrete to engage,the structural deck. The structural deck .hall be of equal orgreater type, thickness and strength to the steel and structural concrete -deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address - non -wind -uplift -related issues, such as deck venting or moisture levels within the. LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10:1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). Unless otherwise noted, insulation adhesive application rates areas follows. Ribbon or bead width isatthe time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions. -i Hot asphalt (HA): Full coverage at 25-30lbs/square. DuPont.INSTA STIK_Quik Set Insulation Adhesive (D45): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. i H:B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,.12-inch o.c., H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): n Cotinuous 0.25 to O.S-inch wide ribbons, 12-inch O.C. OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. Note: OlyBond Green may be used where OlyBond 500 is referenced. - OlyBond Classic (OB Classic): Full coverage at 1 gal/square. - ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. Y Note: When multiple loyers(s) of insulariomond/or coverboord are installed in ribbon -applied adhesive, board joints shall be staggered. y Note: Tire maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-holf the specified ribbons spacing. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum'thickness noted. Tapered polyisocyanurate at the.following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall -these values be used to'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. > H,B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): MDP = -1575 psf (Min.D.5-inch thick) H.B. Fuller:Millennium PG-1 Pump Grade Adhesive.(M-PGI): MDP = -157.5 psf (Min. 0.5-inch thick) i OMG OlyBond SOD (OBSDD): MOP = -45.0 psf (Min. 0.5-inch thick IAulti-Max FA-3) > OMG OlyBond 500 (0B500): MDP = -187.5 psf (Min. D.5-inch thick ISO 95+ GQ OMG OlyBond 500.(OB500): MDP = -315.0 psf (Min. 0.5-inch thick ENRGY 3) i OMG OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick ACFoam 11) ICP Adhesives & Sealants Polyset CR-20: MOP = -117.5 psf (Min. 1.0-inch thick) B For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data.Sheet 1-29 (February 2020). 9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assemb(yshall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall :employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are NEMO ETC, LLC Evaluation Report P9290.02.08-R25 forF1,1654-R27 Certificate of Authorization 432455 7'a EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 CO2018 MEMO FTC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 94 ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1.29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an astersk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for.Zone 2/3 enhancements. 10 For.assemblies with all components fully bonded, the maximum.design pressure for the selectedassembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparisun to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSi%SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates.in a re -roof (tear off) cr recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. if any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-apsof the proposed new roo; assembly- For bonded insulation or membrane over existing substrates in a recover installation, the existing roof.system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention D-ta Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511: for requirements and limitations regarding recover installations. For Structural Concrete Deck or RecoverApplicatiotis,using Sys, zm Type C-1, G2, D-1 or D-2,,'•the insulation is optional. Alternatively, an FBC Approved "insulation board or coverttoard may be used as a separation layer. Board.products.shall be preliminarily attached prior to roof cove r.installation (Note 5 herein). The separator component, shall be documented as meeting FBC.1505 and, for foam :plastic; FBC Chapter 26, when installed with the roof ever in Recover appiicadoiis. 14. Lightweight insulating concrete. (LWIC) shall be cast in accordance With 'FBC Section 1917°to the;satisfaction of.the Authority Having -Jurisdiction. For systems where specific•LWIC is referenced, refer. to current LWIC Product Approval for specific deck construction andaimitatioris. Unless otherwise: noted, forsystems where specific LVy1C is not referenced, the minimum design mix shall be 300 Psi. in all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to'FBC Section 1917.4.1 Point 1. For "pre-existent" I.WfC references; listings were established thrndgh testhlp over lightweight concrete cast using onlyfoaming agent (ASTM C696), water and Portiand:cement(ASTM C150), with no proprietary additives, in accordance with 'procedures adopted by Miami -Dade BCCO (FBC CER1592). Use.of these listings in new construction or re -roof (tear -off) applications is at the discretion of the De"sigrier or Record -and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the followine „MEniIBRANE�7ADHESIVEGOIVIBINATIONs,- : . REFERENCE ,l LAYER , .(. ..... ..` .. MATERIAL APPLICATION BP -AA j Base Ply One or more plies Polyglass G2 Base; FBCApproved ASTM D4601, Type -II Base and Ply sheets; i PI ( Y Y One or more plies-Pol lass Ply 1V, Pnl lass P.lyVI, FBCA roved ASTM D2178, Type IV or VI yg y' Yg PP Hot Asphalt at 20 40 Asphalt -Applied) I Note. ( Asphalt -applied sheets or insulation shall notbe vpplied to poly -film surfaced membranes. Ibs/square i Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT SBS-CAI l Ca P1 p y Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex:56 HP, Elastoflex 56 G, Elastoflex FG350 =r.1.5-2.0 i 56 G FR, Elastoshield TS G, Elastoshield TS G FR, PolyfreskoG SBS (sand-backed),..Polyfresko G SBS FR (sand -backed) gal/square Base Ply ! One ply Elastobase.(sand/sand), Elastoflex V, Elastoflex Sfi Elastoflex S6 HP _ P°`ypius 35 at 1.5-2..0 SBS-CA2 Cap Ply Eiastoshield.HT'G, Elastoshield HTG FR, Elastoflex V G, Elastoflex V G FR, ElastoflexS6, Elastof1ex56 HP, Elastoflex 56G, Eiastof— l� l 56 G FR, Elastoshield TS G, Eiastashieid TS G FR, Polyfresko.G SBS (sand -backed), Polyfresko,G SBS FR (sand-baclie') gal/square Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand),.Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S5, Elastoflex SBS-AA S6 HP; Elastoshield HT (SBS,.Asphalt-Applied) Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V,'Elastdflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, -rot.Asphalt at 20-40 Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko'G SBS..(sand-backed), Polyfresko G 555 FR (sand -backed) lbs/square Note., Asphalt-applied'sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply or Ply One or more plies Elastobase (land/poly),"Elastobase (poly/poly), Elastoflex V, Elastoflex 55, Elastoflez:S6 HP; Elastoshield HT SBS-TA Elastoshield HT G, Elastoshield HT G FR, Elastoflex, V, Elastoflex V G, Elastoflex V G rR, Elastoflex SG, Elastoflex S5 HP, Elastcflex 56 (SBS, Torch -Applied) Cap Ply G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film Torch -Applied backed) NEMO ETC, LLC Evaluation ReportP9290,02.08-1125 for FL1654-R27 Certificate of Authorization 432455 7r" EDITION (2020) FBC NON-HV HZ EVALUATION Revision 25: 09/30/2020 0- 2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 94 '" -' •- .,, ,-� •; MEMePARE'/-AOHESIVEC,ONr_BIN,aTIONS- REFERENCE SBS-SA-H LAYER I Rase T— MATERIAL- - _APPUCA— TION Self -adhering (follov�ed (ses, 5Elr•Adhcsi.& HybrW Syste:::sJ ` Ply Elastobase 54 by torch -applied sheet) Base Ply ( One or more olies Elastoflex SA V, Elastoflex 5A V FR, Elastbflex SA V Pius F-1=_stoflek 5A V Pius FR, EiastoflE.z SA BasQ r91) SBS-SA • Cap Ply Elastoflex SA P, Eiastoflex SA.P FR, Polyreflect . _ (SBS, Self -Adhering) Note: -Ieirl, L'nlessothenvisePotes, perrissib/e membrane substrates for'a85 SA ore ffmited to [he SBS-SA E3ase Ply options hereii Self -Adhering — Efastebase (poly/sand) or Elostabase (poly/poly). APP-CAl Cap Pty Po?yflex,G FR - — ~� _— _� PC350 at APP-TA Bas_ Ply or Piy pne or more plics.Polyglass Base, Polyflex, Polybond �i-ga_i/square j .(APP, Torch -Applied) Cap Ply Polyflex, Polyflex G, Polytlex G'FR, Polybond, Polybond G, Palyfresko G, Palyfresko G FR —N -- —---� 1 orch-App??ed APP-SA-H —82se:Ply" Polyflex SA Base_ 1 Self -adhering (fDllOwed ! '�.fAPP, Se1i-Atlherin;, Hybrid Sys:eas) _ . - by torch -applied sheet) APP-SA —,- Cap Fly Note. Polyflex SAP Po41lex SAP Fri, Polyfreskd G SA, Poiyfresko G,SA FS2, Poly' ooi Unless otherwise substiates APP-SA limitedto (APP; Self -Adhering) noted, ,permissible membrane for aretheSSS-SA.Base Ply qptions herein, , ! Seff-P.dF.aring Dostobase(poly/sand). or Elostabose(poly/pofy)_ 16 •Vaoor barrier options for usp- nvpr Str1Yf—A rnnrrofn Bork f5n11n„ o i by i•.n 4-4 k- i .11 ...a .. :. - ... �" -_ ' °`_ • - `" JRP'1A'B;4R2IER'OPTIONS, °TiZUC7i/RAL�GONCRFiE DECx, FQLLQNiE73Y'ADFtE53VE APPLIED INSULtiTIQN P.cR TAB! c,3A.. OPTION PRIMER I VAPOR BARRIER �..lNSUL'ATfONADHESIVE MDP (PSF) TYPE (NOTE 15) APPOCATION C-VB-1. _� PG1.00 � Elastoflex SA V Plus Self -Adhering D-IST1rCR-ZO 2 inch o.c. C-VB-2, PG100 Polyglass Base Torch -applied . D-IS or CR-LQ, 12- inch o.c. j 75-0 C-VB•3. PG100 Elastoflex SA P I Self -Adhering D-IS; 121inch a.c. -75.0 GIB-4, PG100 riastoflex.SA P Self -Adhering M-OSFA,12-inch o.c. I -157.5 C-VB-S. PG160 Elastoflex.SA P Self -Adhering CR-20, 12-Inch o.c. I 270.0 C-VB-G. PG100 Elastoflex SA V, Elastoflex SA V FR, Elastoflex. SA V Plus, Elastoflex SA V Plus FR Self -Adhering M-OSFA. M-PC-1, OB500 or CR-20, 12-inch o.c. -290.6 C-VB-7. PG100' I SB5=FA (with sanded -top -surface) _ _ Torch -applied M-OSFA; M-PG-2, OB500 or CR-20, 12-inch 17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product. Approval for approved Polyglass and KIA. Coatings roof coaflrgs for application limitations and a Roofing Materials Direawy for fire ratings associated with coating usage. ,w . <::S(iRFAf7NG'OP.TIONS"FOR POLYGLAS5.MODlFiED;BITUiNEiV RODE SYSTEMS„ ` OPTION # SURFACING FLDRIDA PRODUCT APPROVAL SURF-i• PG 300 FL10291 SURF-2• PG 600 FL10291 SURF-3. PG 650 ( FL10291 SURF-4, PG 700 F1.10291 SLJRF-5. PG 700 QS ; FL10291 SURF-6. PG 800 FL10291 SURF-7. Polyplus 60 F.LID291 NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for F.LIG54-R27 Certificate of Authorization 932455 7"' ELUTION (2020) FSC NON-HVHZ EVALUATION Revision 25: 09/30/2020 V7.018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 o, B4 V- � Q 6 C t4 �C 66 O System Deck (Note 1} Roof Cover (Note 15) ;.. = Pnmer No.,. M DP`(PO)- lointtreatment . Sase-Ply Ply Cap Piy - i SELFA,DHERtNGBRSE PLY '' ° r APA I N-208 7/ 6 CA a None OSB joints are covered with 4-inch wide strips of Elastoflex.SA V, rolled into Plus (Optional) SBS-SA, SBS- SBS-SA, APP SA, 0.418 in., place to create.conanuous bond. oraElastoflex A TA, APP-TA SBS-TA, APP-TA 52.5 I Exposure i OSB Plus FIR VJ-2D9 Min. 15/32- I None [done SBS-SA (Optional)SBS-SA,535- SBS-SA,.APF-SA, inch plywood L TA, APP-TA SBS-TA,.APP-TA -900 W-210 _ M n.25/32- _.._ PG100 _...... .. None SBS-SA {Optional}.S655A,rSBS- 5II5-SA; APP-SA, t ) inch:plywood TA, APP-TA SBS-TA, APP-TA g7 S I W-211 (pptionai).PG1D0 "Plywood joints ai•e covered vrith 4=inch witle sups of'Elastofiex SA V Plus, rolled Elastofiex,SA V or (Optional).SBS-SA :SBS- -SBS-SA, APP-SA; I mch'.piywood into.place to create continuous bond. Elastoflex SA V FR I TA, APP-TA SBSTA, APP-TA. ( 97.5 VV-212 Min. 15/32- POLYBRITE745 I None SBS-SA I (Optional} SBS-SA, SBS- SBS-SA, APP SA , inch plywood or:W63000 � TA,APP-TA SBS TA, APP-TA - 05:0, V11-213 Min. 15/32- (Optional):PG1D0 —� Plywood joints.are-covered with 4-inch wide strips of:Elastoflex SA V Plus, rolled Elastoflex 5A V'Ptus (Optional) SBS-SA, SBS- SBS-SA, APP-SA, inch:piywood into place to create continuous' bond. or Elastoflex SA V TA, APP-TA I 585-TA,.APP-TA -135.0 Plus FR HYBRID.$YSTEfN Wm{S SELF=ADHERING`APP B7lSE'.PL'Y - .;rz "` -`'" g": 15/3- kW 214 (plyw (Optional) PG100 None APP SA-H (Optional) APP-TA I -90.0 W=215 Min, 15/32- (Optional) PG100 Plywood joints are -covered with 4-inch.wide strips of Elastoflex SA V Plus, rolled I .inch plywood into. place -�tocreatQ.continuousbond. � APP-SA-H O tional ( P ) APP TA APP-TA-135.0. HYBRIDSYSTENiSWfTHSELFADHERiNGSB581i5EPLY .2 k fI Min,15/32- SBS-TA, W-21% I inch plywood Norte None S95-SA-H (Optional) SBS-TA -90.0 Min. 15/32- W-217 inch.plywood PG100 None SBS=SA-H i (Optional),SBS-TA SBS-TA -975 W-218 Min. 15/32 (Optional) PG10D Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled ( j1 inch plywood into place to create continuous bond, SBS-SA-H i (Optional} SBS-TA SBS-TA 97.5 Min..1SJ32- POLYBRITE 745 W=219 inch plywood or WB3000 None SBS-SA-H (Optional) SBS-TA I SB5=TA I -105.0 NEMO ETC, LLC Certificate of Authorization $132455 ID2019 NEMO ETC, LLC 7" I EDITION (2020) FBC NON-HVHZ EVALUATION Polygiass Modified Bitumen Roof Systems; (954) 233-133D Evaluation Report P9290.02.08-1125 for F1.1654-1127 Revision 25: 09130/2021) Appendix 1, Page 37 of 94