HomeMy WebLinkAboutProduct Approval Metal RoofFlorida Building Code Online
1/23/21, 8:55 PM
BCIS Home I Log In i User Registration j Hot Topics i Submit Surcharge i Stats & facts i Publications t Contact Us i BCIS Site Map i Links ( Search
} Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL27499-R2
Application Type
Revision
Code Version
2020
Application Status
Approved
REVIEWED FOR
Comments
Archived
CODE COMPLIANCE
ST. LUCOE COUNTY
Product Manufacturer
Dynamic Metals
Address/Phone/Email
3201 SE Dominica Terace
BOW �
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetai.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Scott Wolters
the Evaluation Report
Florida License PE-62354 ContraCtair
U
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2026 Copy.
Validated By Lucas A. Turner, P.E., MBA
7, Validation Checklist - Hardcopy Received
Certificate of Independence FL27499 R2 COI Dyn COI.p t
Referenced Standard and Year (of Standard) Standard
Year
TAS 100
1995
TAS 110
2000
TAS 125
2003
https://www.flaridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHr09JhSJEVB8g2gEgg%3d%3d Page 1 of 5
Florida Building Code Online
1/23/21, 5:55 PM
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBCApproval
Date Approved
Date Revised
Method i Option D
10/24/2020
10/26/2020
11/01/2020
12/16/2020
12/17/2020
Summary of Products _
.Go to Page °' ° . Page 1
Modeli Number,or Name - .
Description,
27499.1
DM Class 1000 1" Nailstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R2 II NSSI6HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R2 AE DM Evall.pdf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nailstrip;
032"Aluminum1roof panel, 16" wide, with 1"snap fit seams.
Limits of Use
Installation Instructions
Approved for -use in'HVHZ Yes
17L27499 -112 II_NSAI6HZ.bdf
Approved for use. outside HVHZ: Yes
Verified By: Scott' Wolters 62354
Impact''Resistant: N/A
Created'by Independent Third Party: Yes
Design Pressure: N/A
Eva luatiot Reports
Other: Please see Eval report -for Limits of'Use.
FL27499 .R2 IAE DM Eval2.pdf
;Created by_ Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nailstrip
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R2 11 NSA19HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R2 AE DM Eval3.pdf
Created by Independent Third Party: Yes
27499.4 DM Class1050 1 1/2"; Nailstrip •
24 Ga:'Galvalume coated steel roof panel, 19" wide, with 1
lj21.6nap fit seams
Limits -of Use
Installation' i istructions
Approved fovuse in HVHZ Yes
FL27499 'R2 II` NS519HZ:odf
Approved for use outside HVHZ: Yes
Verified By: Scotk.Wolters; RE. FLPE# 62354.
Ympact:Resistant: N/A
Created by -Independent Third Party: Yes.
Design Pressure'e N/A
Evaluation. Reports
Other: Please see Eval report for Limits of Use.
FL27499.,R2 AE DM Eval4.p_df
'Created by Independent Third Party: Yes
27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 RZ 11 DM Dwg5;pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394
https://www.florfdabuilding.org/pr/pr_app_dtl.aspx7param=wGEV)(OwtDquHOE2Ywe%2bOsCepABg3%2bkMGlAUfHr09JhSJPVBgg2gEgg%3d%3d Page 2 of 5
Florida Building Cdde Online
1/23/21, 8:55 PM
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R2 II 2MSSISHZ.pd
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R2 AE DM Eva119.pdf
Created by Independent Third Party: Yes
27499.20'
DM Class 500 5V Crimp
26 Ga. galvalume coated steel roof panel; 24" wide, with 5V
crimp..
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R2 II DM Dwg20.pdf
Approved for'use outside HVHZ-; Yes.
'Verified By: Scott Wolters 62354
Impact Resistant. N/A
Created by Independent Third Party: Yes
Design Pressure: N/A , "`
Evaluation Reports '
Other: Please see Eval report for limits of Use.
FL27499 R2 AE DM Eval20.pdf
Created by Independent`Third Party: Yes
Go to Page 1 / 2
MIM
Contact Us :: 2601 Blair Stone Road Tallahassee R _ 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida low, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
EM - RNM N IM
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHr09JhSJEVB8g2gEgg%3d%3d Page 5 of 5
CLASS 500 5V CRIMP 24" WME
26 GA GALVALUMEROOF PANEL (HVHZ)
12'
Panel Profile
DWI CLASS 500 5V CR MIP 24" WIDE
26 GA GALVALUME ROOF PANEL (HVHZ)
If
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, 'Dynamic Metals FL #27499.20, DM Class 500".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions shown on Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SS02-2320920
Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24' Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need more information concerning this approval, please contact me.
.t„Stf3PP{l{
Thank you,
*,er,
"D 62354
ott +
FL PE# 62354 �,
CCT23 20211 r�'. ST"iTE or-
w, ti.s
rar Gas
wi;t Eli\a r1 ! n"{'i 7 ``l."1 t 3,V1 nisi t t
4 "',��1i :�IJC.i� ar. t-i '� �:�:rt" '?;\t;7 S, Wri3r9,`
�~ Feld
Installation
Perimeter & Comer
Installation
Max. Design Pressure:
--117.75 pst
-206 psf
I Fastener Spacing:
4" From Ends,161 Max. O.C.
` 4" From Ends, 8" Max, O.C.
Min Panel Fasteners:
#10x1 %2' HiLo HWH Screw
vrith Weather seal Washer
#10x1 %:" HiLo HWH Screw
with Weather -seal Washer
Fire Barrier, Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the lire barrier within the assembly. (See note #2 below)
Note: Outside of Vie HVHZ,1" round plastic caps meeting the requirements of
FBC Section 1507.1.1.1, may be used to prevent galvanic reactions,
Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section
1507.1.1.1(min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ,1" round plastic caps meeting the requirements of
FBC Section 1507,1.1.1 may be used to prevent galvanic reactions.
Minimum Substrate: % (15132" min) 4-ply CDX Plywood or Y4" solid wood planks S.G. = .42
min. nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The 3/4" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1607.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation,
t7lt,'At
WOLTERS EIS GINEEM-Ci
ENGINEERING. DRAFTING. CONSULTING
15211 971h Road It
'Nest Palm Beach. FL 33412
PhIPx: (561) 225-19E2,
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE
ROOF PANEL (FLPA# 27499,20)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 711, Edition (2020) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Inlertek with results shown in test reports G3443,38-450-44 and H2686.02-
45044, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing `5VS-HZ" dated 8115119, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculations to support "5VS-HZ' drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7'^ Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 24" (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min. Slope: HVHZ; 2"112"
Non-HVHZ: Y2"112" (with Lap Sealant)
3712" (no Lap Sealant)
s'vvi, ^c•r�
-- �:a GJ l; "`i7..e: •:iiAi ...1 !d'i,'Md:..�. _ 1F �'.f ., �.i rivr..