HomeMy WebLinkAboutProduct Approval - Metal RoofingFlorida Building Code Online
1/23/21, 8:55 PM
Flai"tiia
BCIS Home ! Log In j User Registration i Hot Topics f Submit Surcharge i Stats & Facts 1 Publications . f Contact Us 1 BCIS Site Map j Links j Search ,
Product Approval
USER: Public User,
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL27499-R2
Revision
2020
Approved
Dynamic Metals
3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Lara Jesus
juan@dynamicmetal.net
Roofing
Metal Roofing
I' •
Rr... rti E
L" ME COUNTY
nocc
�� i t �
.,
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Scott Wolters
PE-62354
Keystone Certifications, Inc.
12/31/2026
Lucas A. Turner, P.E., MBA C®PY
Validation Checklist - Hardcopy ReceifdILE
FL27499 R2 COI D," COLpdf
Standard
Year
TAS 100
1995
TAS 110
2000
TAS 125
2003
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=vvGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHr09JhSJEVB8g2grgg%3d%3d Page 1 of 5
Florida Building Code Online
1123/21, 8:55 PM
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Method 1 Option D
10/24/2020
10/26/2020
11/01/2020
12/16/2020
12/17/2020
-- 7 — 7
d—
Summary of Proucts
Go to Page Page
FL # Model,"'Number or Name 4 Description
27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R2 II NSSI6HZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R2�AE DM Evall.pdf
Created by Independent Third Party: Yes
27.499.2 DMClass 1000 1" Nailstrip; .032'"Aluminum-roof panel, 16" wide, with 1" snap fit seams.
Limits of Use Installation`Instructions
Approved for use in HVHZ: Yes FL27499 R2'II'' NSAI6HZ.2
Approved foruse outside HVHZ: Yes Verified By] Scott•Wolters 62354
Impact Resistant; N/A Created 'by Independent Third:Party--Yes
Design Pressure: N/A Evaluation Reports.
Other: Please -see Eval report,for Limits of Use. FL27499 .R2 AE,.DM Eval2.)dU "
Create&by Independent Third Party:'Yes
27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 g2 U_NSAI9HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R2 AE DM Eval3.pdf
Created by Independent Third Party: Yes
21499.4
DM Class 1050 1-1/2_'•Nailstrip'
24 Ga. Galvalume'coated steel roof panel;,19" wide, with 1
i/2°'snap fit'seams
Limits'of•Use
Installation Instructions,
Approved for. use -in:HVHZ; Yes
FL27499' R2 II NSSI9HZ.odf
Approved for-use,ok6ide HVIiZ: Yes :.
Verified By: ScottVolters; P.E.'FLPE# 62354
Impact Resistant.- N/A
Created -by Independent Third Party:. Yes
Desigp Pressure; ,N%A' ,,
Evaluation. Reports.
Other:.Please see. Eyal report for limits of Use.-
FL27499 R2 AE DM Eval4.�df
Created by.Independent Third Party: Yes
27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R2 II DM Dwg5.Ddf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepAgg3%2bkMGlAUfHr09JhSJEVBBg2gEgg%3d%3d Page 2 of 5
Florida Building Code Online
1/23/21, 8:55 PM
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R2 II 2MSS18HZ,pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R2 AE DM Evall9.odf
Created by Independent Third Party: Yes
27499.20 . DM Class 500 5V Crimp 26 Ga. galvalume coated steel roof panel, 24" wide, with 5V
crimp.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 42 II DM bwa20.pdf
Approved for tlise outside HVA& Yes Verified •By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
'Other: Please see Eval report for Limits of Use. FL27499 R2 AE DM Eva120:pdf
1
Created by, Independent Third Party: Yes
;Go t6 Page 9 /
1^L•J.R a
Contact Us :: 2601 Blair Stone Road. Tallahassee F1_ 32399 phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, s ad contact the
h office b phone or b traditional '
Y y ph n y to atonal mail. If you have any questions, please contact 850.487.1395. Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please dick here_
Product Approval Accepts:
r® eCtxk
CreLditt Card
Safe
securityrm Lei; tucp,
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM61AUfHrO9JhSJEV88g2gEgg%3d%3d Page 5 of 5
DM CLASS 500 5V CRIMP disc WIDE
26 GA GALVALUME ROOF PANEL
12
?-
See I
f'of
S
23' hi-901:nit Nei Coverage
j I
518.
Panel Pcoble
v:
�q✓
9
c ry c
a
d
C`n C
b
u
f
G�
40
fi C
Ma
Q
G
0
�ua
i
.J
n
o w
m 3 c
_-..-- 1h,
DM CLASS 500 5V CRMIP 24" WIDE
26 GA GALVALUME ROOF PANEL (HVHZ)
p—% p'.1d.
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61G20,3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, 'Dynamic Metals FL 927499.20, DM Class 500'.
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party CIA provider, to the dimensions shown on Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SS02-2320920
Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need more information concerning this approval, please contact me.
Thank you,
No fi235a
40,0ttl
*,erz_
FL PE#62354
OCT23 7010 S'riE orONAI
-
l7l P 'i pxx lr t"L`� i0 i� 1' 7 r`73J' f �•^ i ( �5'C
Field
Installation
_ Perimeter & Comer
Installation
Max. Design Pressure:
_
T-117.75 psf
_
-206 psf
Fastener Spacing.
4" From. Ends;16" Max. O.C.
_
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
#10x1 %' HiLo HWH Screw
with Weather -seal Washer
#10x1 %z" HiLo HWH Screw
with Weather -seal Washer
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ,1" round plastic caps meeting the requirements of
FBC Section 1507.1.1.1, may be used to prevent galvanic reactions.
Underlayment: Minimum ASTM D 226 Type 11, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ,1"round plastic caps meeting the requirements of
FBC Section 1507.1.1.1 may be used to prevent galvanic reactions.
Minimum Substrate: Yz (15I32' min) 4-ply COX Plywood or'/4" solid wood planks S.G. = .42
min. nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The '/" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed ArchitecUEngineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation,
C:. i4r'✓ 3� .i � �ii';ti; f_Jci;', �4. .'i �f„�'Ft?.1� 5, E rt'i:A:v" : .
WOLTERS ENGINEERING
ENGINEERING. URAFFFNG, CONSULTING
15211 97m Road N
"Nest Palm Beach, FL 33412
PhIFx:(561)225-1932
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24" WIDE
ROOF PANEL (FLPA# 27499.20)
MANUFACTURER- DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "5VS-HZ" dated W15/19, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculations to support "5VS-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7u, Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 24" (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min. Slope: HVHZ: 2112"
Non-HVHZ: V2"!12" (with Lap Sealant)
3712" (no Lap Sealant)