HomeMy WebLinkAbout21-08-15-00 Pursuit New Tooling Facility Temp Power E1_JLL.pdfh roj ect: 0 0 I N 0 N U N 0 r H J_ U Q LL_ U z J 0 0 w z D w 0 0 I I Uj 0 I N U z U) w Q U 0 Q 0 z w w z 0 z w J Q z 0 Q U EXISTING FPUA PAD MOUNT TRANSFORMER ELECTRICAL NOTES THESE NOTES APPLY TO ENTIRE PROJECT: A. CODES. ALL ELECTRICAL WORK SHALL COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, THE NATIONAL ELECTRICAL CODE AND APPLICABLE LOCAL CODES, WHICHEVER IS MORE STRINGENT. B. POWER COMPANY. THE ELECTRICAL CONTRACTOR IS TO COORDINATE ALL SERVICE REQUIREMENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN ALL WORK NECESSARY TO MEET POWER COMPANY SPECIFICATIONS IS IN THE BID. ALL ELECTRICAL GEAR SHALL BE APPROVED BY THE POWER COMPANY. THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE POWER COMPANY PRIOR TO BIDDING TO DETERMINE ALL FEATURES, FUNCTIONS AND LOCATIONS OF SERVICE. FURTHERMORE, THE ELECTRICAL CONTRACTOR IS TO MAINTAIN CONTINUOUS CONTACT WITH THE POWER COMPANY DURING THE PROJECT, AND IS TO NOTIFY THE ENGINEER IMMEDIATELY OF ANY CHANGE PROPOSED. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SERVICE THOROUGHLY AND DOCUMENT THE COORDINATION. C. SCALES. DO NOT SCALE OR TAKE DIMENSIONS FROM ELECTRICAL DRAWINGS. D. GFCI. OUTLETS INSTALLED OUTDOORS, WITHIN 6' OF A SINK, AND OTHERWISE REQUIRED BY CODE ARE TO BE ON GFCI TYPE CIRCUIT BREAKERS. APPLICABLE lit'ILDING CODES FLORIDA BUILDING CODE, 6TH EDITION (2020) NFPA 70, NATIONAL ELECTRICAL CODE (2017) FLORIDA FIRE PREVENTION CODE, 6TH EDITION (2020) FLORIDA ENERGY CONSERVATION CODE, 6TH EDITION (2020) MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES IN THEIR LATEST REVISIONS. CONTRACTOR TO COORDINATE SPECIFIC REQUIREMENTS OF EQUIPMENT WITH MANUFACTURERS' SHOP DRAWINGS. ALL EQUIPMENT SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. PANELBOARI) SCHEDULE VOLTAMPS LOAD DESCRIPTION WIRES AWG POLES AMPS Y BUS A B Y AMPS POLES LOAD DESCRIPTION WIRES AWG VOLTAMPS A0 B0 A0 B0 7500 CONST TRAILER 1 2 125 1 2 60 2 TEMP PANEL 'N' 6 3000 7500 3 4 3000 1000 TEMP POWER RECEP 12 1 20 5 6 60 2 TEMP PANEL 'S' 3000 1000 TEMP POWER RECEP 12 1 20 7 8 3000 1000 TEMP POWER RECEP 12 1 20 9 10 1000 TEMP POWER RECEP 12 1 20 11 12 13 14 15 16 17 18 9500 9500 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPS 15500 115500 1 1 TOTAL DEMAND VA 6000 6000 TOTAL DEMAND AMPS SUB -TOTAL VA SUB -TOTAL 129 1 129 1 1 PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 10,3W 120/240 10,3W ❑ BUS AMPS ❑ 100A ❑ 400A N 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE ❑ MAIN LUGS ONLY M200A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH NSURFACE ENEMA 3R EHINGED DOOR EKEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL e PAINTED STEEL 0 NAMEPLATE BRANCH ❑ 12 M18 ❑ 24 POLES ❑ 36 ❑ 42 ❑ __ BRANCH DEVICES MCIRCUIT BREAKERS ❑ FUSES ❑ ____TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) ❑10,000A ❑30,000A ❑65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A 0 22,000A ❑ 50,000A ❑ __,000A ❑ SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED Ol O2 O NOTES NEUTRAL BUS ❑ 50% ❑ 200% 100% ❑ ___% BUS MATERIAL MCOPPER [:]ALUMINUM NGROUND BUS REQUIRED ❑ _______PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED PANELBOARD SCHEDULE N VOLTAMPS LOAD DESCRIPTION WIRES AWG POLES AMPS Y BUS A B Y AMPS POLES LOAD DESCRIPTION WIRES AWG VOLTAMPS A0 60 A0 B0 1000 TEMP POWER RECEP 12 1 20 1 2 20 1 TEMP POWER RECEP 12 1000 1000 TEMP POWER RECEP 12 1 20 3 4 20 1 TEMP POWER RECEP 12 1000 1000 TEMP POWER RECEP 12 1 20 5 6 1000 TEMP POWER RECEP 12 1 20 7 8 9 10 11 12 13 14 15 16 17 18 20 00 2000 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPS 3000 3000 DEMAND VA 1000 11000 TOTAL DEMAND AMPS SUB -TOTAL VA SUB -TOTAL 25 25 "TOTAL PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 10,3W 120/240 10,3W ❑ BUS AMPS M100A ❑ 400A ❑ 200A ❑ 600A ❑ 225A ❑ ___A MAIN DEVICE ❑ MAIN LUGS ONLY M60A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH NSURFACE ENEMA 3R EHINGED DOOR NKEYED LATCH ❑ DOOR -IN -DOOR ❑STAINLESS STEEL E PAINTED STEEL N NAMEPLATE BRANCH ❑ 12 M18 ❑ 24 POLES ❑ 36 ❑ 42 ❑ __ BRANCH DEVICES MCIRCUIT BREAKERS ❑ FUSES N ALL TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) M10,000A ❑30,000A ❑65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A ❑ 22,000A ❑ 50,000A ❑ __,000A ❑ SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED Ol O2 O3 NOTES NEUTRAL BUS ❑ 50% ❑ 200% 100% ❑ ___% BUS MATERIAL ❑ COPPER E ALUMINUM NGROUND BUS REQUIRED ❑ _______PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED PAN ELIMARI) SCHEDULE. 'S' VOLTAMPS LOAD DESCRIPTION WIRES AWG POLES AMPS � Y BUS A B � Y C) AMPS POLES LOAD DESCRIPTION WIRES AWG VOLTAMPS A0 B0 A0 B0 1000 TEMP POWER RECEP 12 1 20 1 2 20 1 TEMP POWER RECEP 12 1000 1000 TEMP POWER RECEP 12 1 20 3 4 20 1 TEMP POWER RECEP 12 1000 1000 TEMP POWER RECEP 12 1 20 5 6 1000 TEMP POWER RECEP 12 1 20 7 8 9 10 11 12 13 14 15 16 17 18 2000 2000 TOTAL CONNECTED VA VA TOTAL CONNECTED AMPS 3000 3000 TOTAL DEMAND VA 1000 1000 TOTAL DEMAND AMPS SUB -TOTAL VA SUB -TOTAL 25 25 PANELBOARD RATINGS PANELBOARD FEATURES VOLTAGE ❑ 120/208 10,3W 120/240 10,3W ❑ BUS AMPS M100A ❑ 400A ❑ 200A ❑ 60OA ❑ 225A ❑ ___A MAIN DEVICE ❑ MAIN LUGS ONLY M60A CIRCUIT BREAKER ❑ ____A FUSED SWITCH ENCLOSURE ❑ FLUSH NSURFACE ENEMA 3R EHINGED DOOR EKEYED LATCH ❑ DOOR -IN -DOOR ❑ STAINLESS STEEL EPAINTED STEEL 0 NAMEPLATE BRANCH ❑ 12 M18 ❑ 24 POLES ❑ 36 ❑ 42 ❑ __ BRANCH DEVICES MCIRCUIT BREAKERS ❑ FUSES N ALL TO BE GFCI BREAKERS ❑ LOAD CENTER PERMITTED INTERRUPTING RATING (AIC SYM) N10,000A ❑30,000A ❑65,000A ❑ 14,000A ❑ 42,000A ❑ 100,000A ❑ 22,000A ❑ 50,000A ❑ __,000A ❑ SERIES RATING PERMITTED ❑SERVICE ENTRANCE RATED Ol O2 O3 NOTES NEUTRAL BUS ❑ 50% ❑ 200% 100% ❑ ___% BUS MATERIAL ❑ COPPER E ALUMINUM NGROUND BUS REQUIRED ❑ _______PANELS IN PARALLEL ❑ THROUGH FEED LUGS REQUIRED DRY TYPE TRANSFORMER 37.5kVA, 48OV, 1 � TO 120/240V, 1 �, 3W IN NEMA 3R CABINET SERVICE DISCONNECT PROVIDE MAIN BONDING JUMPER 1 1 /2"-3#1 /0 (AL) RUN THROUGH METERING CT's #6 CONNECT PANEL PROVIDED WITH CONSTRUCTION TRAILER 120/240V, 1 �, 3W, 125A T F I 1 1 /2"- 3#1+6G #6 L 1"-2#3+6G L 2"-3#3/0+6G L 1"-3#6+8G TEMPORARY POWER RISER DIAGRAM SOURCE = 480Y/277V, 3�, 4W 1 "-3#6+8G ----------------------- e k�l I a a a ____________ `, I ° d ° -a ----------- °� tl ° ° ° ° ------------ k \ tl a ° o d ° kI I i I I r tl a a ° ..d I I ------------ ° d °. o' 4. d. a 'a. A 4° c II k I I d' d° I I A °a d° ° .41 d.°d d 00 1 ° .. tl : . °" c d �� . tl .. d I I/ I 2 1 d-°. - °° .: 4 ----- ------ I '4' ° a . .'d. ° * . . 4 I I _ 1---------- I LL - d °__ _ d :.° d M ____ _______ 1 a.4 d II +----------- ---------- I -4 ° R ° ° d. A. ° 4 d IIj----------- --- -------- d II --------- 4. 1 d II 1 a ° a a 4 ° III 1----------- ----------- I -I _ A ° d .d 11 r-----------CIO b„8 I. 14 d d a n +----------- _---------- I I tl d. ° d I 1 4.- - ° d ° I I r----------- ° I tl ° . 40 I 1 -- SERVICE TO d n I TEMPORARY FPUA a TRANSFORMER �� ,./ d ° 4. ° ° 13 1. a d . -------------------- - _ ° _ q�o� e/ \ d' , <° .e 4 . ° .d 4a° u I ° II------------ 14-----� d ° 4 d ------------------------ II ------------ ------------ I d - ° --° - _ ° _ -a d °a ° ° °-_° °Q ------------ ° ° - - - e - - - _ - _ ° - - d 9. x a ------------ 1 g I° a d° d d d< d °. ° ° d 1 J ° d ° .... d . II ------------ I d I a a °_° °_ d q ° ° d d d a ° ----------- - °d II • II o- II I ° 4 ° II .a II _d3ar-, 1 d err' �-� 1 7 i II II ° II II � II 1 ° d .d ° I I I I I d II I 1 d'. II I 1 II -----------I I I do II ° d II-----------tI I° II 1 a II I I d I 4 II ___________a 1 J -,4 I ° II-----------i 1� I II I 1° d d q d--------------------------------- U- li a II -x- - - - x -.ad: I .. ° Jl d I d ° . F ° I 1 P d a .d. °I .. 1 r----------/--- x---------- (PANEL 'TI' � tl I I I �- CONSTRUCTION TRAILER tl EI tl tl I tl NEW MAIN FPUA tl TEMPORARY PAD MOUNT TRANSFORMER a 4 a d ° d° d d . °ED M d ° E l I El d �F-, o ELECTRICAL SITE PLAN SCALE 1" = 40'-0" PANEL 'S' ;. d a ° G d. 4. .° d. ° ° ° d d a' - a d. a a .. 4 d 4. a: 4 .Q 4° d° . d 4 n' 4 d ° 4, d .d °. . °.. .a d44 ° ° d ' ° .° d C ° .. .d° °*° A. d . .d ° d ' . d ° ° d. d.. .a. d ° ° ° d °d c 4 ° d°d .° . _ d .°. .Q.° d ° d. ° ° V 4° G ° 4'. C d d a a u Know. what's below. Call before you dig. TEMFOKAKY CON5TKUCTION FOWE K FOK FUK5UIT DOATS New Marufacturing Facility 3901 5t Lucie [3Ivd. Ft Fierce FL 34946 Key Plan: 155ue5: No.: Date: Description: Architect: DONADIO & Associates, Architects P.A. 2001 9th Avenue, 5ulte 308 Vero Beach, FL 32960 Te1.772.794.2929 Fax.772.562.8600 License No. AA0002238 www. d o n a d i o -a rch.00 m Consultant: CARDtnRL EI cunEERIIIG FISSOCIFITES inc, ST. LUCIE OFFICE 575 NW MERCANTILE PLACE #206 PORT ST. LUCIE , FL 34986 OFFICE: (561) 746-6343 CORAL SPRINGS OFFICE 10211 W. SAMPLE RD. #201 CORAL SPRINGS, FL 33065 OFFICE: (561) 746-3602 info@CEAengineers.com PE# 78477 CA LIC. 31555 Joseph LDigitally signed by Joseph L Lammer Lammers Date: 2022.03.11 s 18:00:12-05'00' Drawing Title: ELECTKICAL - f AKTIAL 51TE FLAN Drn: Dwg. File: NL Chd: XREF File: DJL/JLL Project No.: Not File: 2021-26 Sheet No.: Cert. No.: 12,456 Date Signed: El .0 Copyright ©2021, uonadio & Associates, Architects, P.A.